Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender

Healthcare and Medicine
Eprocure
Opening Date22 Mar 2025
Closing Date21 Apr 2025
Tender Amount₹ 11,40,00,000

AI Insights

Technical
Technical
Technical Capacity
... View More
The required prior work experience for the bidder is not explicitly stated in terms of a specific number of years. However, the bidder should have completed works that allow them to be considered for up-gradation to the stipulated eligible class based on past experience of completed works and financial soundness. The bidder should have completed at least one work of similar nature. No specific amount or percentage of similar works completed is mentioned. The value of works completed is also not specified.
Costs
EMD
₹ 8,95,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_702295_1Tender No
CEBZ/PGH/T-40 of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/

GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
SCHEDULE A PART II-B (Internal Water Supply)
-
-
-
... More
S&F health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and directed.
13
-
-
... More
S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all specified and directed.
26
-
-
... More
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
34
-
-
... More
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
1
1394041
-
... More
SCHEDULE A PART III-B (Internal Electrification)
-
-
-
... More
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -
-
-
-
... More
Note: (i) Also includes inverter wiring with one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate.
-
-
-
... More
(a) One light point point /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch. ( 9 points for Lift Schedule)
398
-
-
... More
(b) One three pin 5 Amp socket on same board with other switches.
72
-
-
... More
(c) One three pin 5 Amp socket on independent board
68
-
-
... More
(d) All as per item No 5.01 above but for two way wiring
4
-
-
... More
(e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm. ( 9 points for Lift Schedule)
138
-
-
... More
Supply and fix High quility LED T5 integrated batten tube light 20 Watt with aluminium extrusion with frosted PMMA/PC diffuser, internaly pre wired of 1.5 sqmm twin twisted flexible cable incl connection with ceiling rose all as specified & directed.
136
-
-
... More
Supply and fixing LED batten light fitting 20W, 220V,with microwave motion sensor based technology with aluminium housing & integrated electronic driver of make Havells with Cat part no LUMILINESMART20WLED865PCWH or equivalent make of Bajaj/Philips/Crompton complete all as specified & directed.
27
-
-
... More
Supply and fix LED Bulb 9 Watt complete all as specified and directed.
38
-
-
... More
S & F MCCB 4 pole 200 A, 415 V, 25 KA, 4 Pole with Icu=100% Ics complete all as specified and directed.
2
-
-
... More
S& F socket outlet for TV/Video/audio device modular type with inner and outer modular plate type, specially built for wall/high mounted TV and incl pressed steel/metal flush box concealed complete
10
-
-
... More
S& F socket outlet for Telephone (RJ11) modular type with inner and outer modular plate type for communication (telephone) incl pressed steel/metal flush box concealed complete
10
-
-
... More
S & F Recess/surface mounting motion sensor based LED luminaire 600mm x 600 mm ,36 W, 220V, with inbuilt PIR sensor and can detect motion from upto 5 mtr height, high efficiency PMMA diffuser soft glare free light suitable for recessed/ surface mounting ,with powder coated CRCA housing with LEDs, seamless front frame complete with driver and all accessories internally pre-wired and including necessary cutting as required in panel and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
71
-
-
... More
S&F sheet metal enclosure for VTPN MCCB DBs(double door type) ,12 way (F1+36 module ) with IP 54 protection , isolated neutral bar, mechanical impact strength IK 09, suitable for MCCB upto 200 A, with cement spill protector including blanking plate as required with rated bus bar, 415 volts fixed complete all as specified and directed.
2
-
-
... More
M&L for earthing with copper earth plate electrode of size 60x60x3.15 mm thick buried directly in ground to a depth not less than 3.25 Mtr deep below normal ground level with top edge of the earth plate not less than 2.50 Mtr deep below normal ground level connected to copper strip of size 20x3 mm as earthing lead by means of nuts, bolts and washers of copper / brass after welding/brazing of copper strip to earth electrode to the full length of earth plate, 25 mm dia GI tubing light grade protection pipe up to test point, 20 mm dia GI watering pipe medium grade with funnel and wire mesh , PCC pit 1:3:6 with pit cover of size 30x30 cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4 mm, adequate qty of charcoal dust and salt layers all around the earth plate ,removal of surplus soil and returning and filling in all as required at site including test point made out of steel plate of size 75x75x6 mm fixed to wall as specified in plate No. 3 of SSR Part-I and directed by Engineer-In-charge. ( 06 for lift schedule)
10
-
-
... More
pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
-
-
-
... More
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
1
2550714
-
... More
SCHEDULE A PART V A (Road, Path and Hardatanding) for details refer pdf folder
1
907577
-
... More
SCHEDULE A PART V B (Road, Path and Hardatanding)
-
-
-
... More
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved coloue, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method over and including 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified complete all as specified and directed.
300
-
-
... More
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
1
1042044
-
... More
SCHEDULE A PART VI B (Sewage Disposal)
-
-
-
... More
RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 Users
2
-
-
... More
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia X 4.50 M effective depth all as specified and shown in drawing TD-309, sheet No 1/4 to 4/4
4
-
-
... More
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
1
1025577
-
... More
SCHEDULE A PART VIII (Protective Work / Retaining Wall) for details refer pdf folder
1
4116097
-
... More
SCHEDULE A PART IX A (Hot Water Supply) for details refer pdf folder
1
62805
-
... More
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder
1
36383
-
... More
SCHEDULE A PART X B (External Water Supply)
-
-
-
... More
M&L for brick masonery chamber (Valve Pit) for opening and closing valve of internal diamensions (600mmx600mmx600mm) build in CM 1:6 including fixing MS sheet cover 5mm thick over angle iron frame of size 40x40x4 mm with laying and locking arrangement and 15 mm thick cement plaster in CM 1:4 internally with two coat of synthetic enamel paint over one coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed
1
-
-
... More
Cutting existing steeltubing of size 50 mm/ 80 mm for alternation or addition(each cut measured)
1
-
-
... More
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
1
771369
-
... More
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)
-
-
-
... More
Supply, fixing, connecting and comissioning of out door type LT Cubical panel feeder pillar box powder coated with structural siemens gry RAZ 7032shall be factory fabricated as per IS-8623 rated for short circuit rating of 35 KA, front and rear operated twin leaf doors and lockable by keys for both sides having louvers and air vent, gasket and totally vermin proof made out of 3 mm thick CRCA sheet duly compartmentalized for incoming and outgoing shall have extension links of capcity 1.5 times the rating of individual fedder i e not less than 300 mm long, all link shall be insulated with colour coded heat shrinkable sleeve and suported on DMC/Epoxy insulateors having
1
-
-
... More
provision for termination of incomer and out going cables. All control wires shall be not less than 2.5 Sqmm multi strand copper conductor and properly bunches/tide, ferruled for proper identification and crimped with adequate size of lug. The pannel will have a bottom support of channel of suitable size, duly coated with zinc metal coating . A detachble pre-drilled gland plate of thickness 3.15 mm thick shall be provided with at the bottom for entry of cable with gland. Manufacturers name plate with feeder details and danger plate.
-
-
-
... More
(a) Copper busbar duly insulated with colour coded heat shrinkable sleeve and mounted on DMC/Epoxy insulators of capacity 600 amps for three phase and 450 Amp for neutral-01 set and phase indicating lamps and Ampere meter,Voltmeter, complete with CT and selector switches for three phase current and voltage display.
(b) MCCB FP 415 volts of capacity 400 amps adustable type with ruptuing capacity 36 KA (incoming) -01
(c) Change over switch 400 Amp-01
(d) MCCB FP 415 volts of capacity 315 Amps adustable type with ruptuing capacity 36 KA- 01 Nos (Outgoing)
(e) -do- but 200 Amps -02 Nos with rupturing capacity 36 KA (outgoing)
(f) MCB SPN 63-100 Amp = 02 nos with rupturing capacity 25 KA (outgoing)
-
-
-
... More
Supply, installation, testing & commissioning of diesel engine silent generator set with acoustic enclosure confirming to latest CPCB norms, water cooled capacity 250 KVA ( generator out put should be250 KVA/200 KW) 50 Hz AC supply, engine as per IS : 10001/ 10002 and alternator as IS : 13364 complete including engine alternator mounted on common base frame and canopy fabricated from steel channel of suitable size, engine and alternator shall be anti vibration mounting pads,sound proof canopy as per latest CPCB norms and foundation as per manufactures instruction / design complete all as specified directed with and including the following provision :-
1
-
-
... More
(a) ALTERNATOR :- Alternator of capacity 250 KVA/ 200 KW at 0.80 power factor after considering derating factor AC 3 phase , 415 volts, 50 Hz, 1500 RPM brushless type self excited, self regulated screen protected type and AVR system.
-
-
-
... More
(b) DIESEL ENGINE:- Diesel engine water cooled suitable for alternator of250 KVA capacity considering all points for derating factor taking into account the altitude, humidity of maximum temperature of Ranikhet with the following provision :- (i) Radiator and sound proof canopy as per latest CPCB norms and foundation etc. of capacity 250 KVA
(ii) Fly wheel (iii) Air cleaner (iv) water pump with thermostat (v) Electric starting system with the help of batteries as per manufacture's specification with key ignition and push button (vi) Temperature meter and oil pressure gauge
-
-
-
... More
(vii) Fuel tank of made of mild steel sheet of required capacity as per standard with inlet and out let connection, filling cap, drain valve air vent with calibrated scale on outdoor surface floor mounted with suitable angle iron support (viii) Fuel/ oil filter (ix) Battery charger as per manufacturer's recommendation (x) Battery maintenance free with connecting lead. Make Exide / Amaron /Luminous (xi) Foundation as per manufacturer's instruction / drawing (xii) Heating system to start engine during winter season
-
-
-
... More
(xiii) Engine protection device against short circuit overload low lubricanting oil high pressure water temperature and over speeding of engine (xiv) Anti vibration mounting pad - set of 6 Nos (xv) Exhaust system up to required height and length (xvi) Engine warranty and test certificate (xvii) RPM meter and hour meter (xviii) Including Gen set control unit complete
-
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and includingGI Strip of size 32x6mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM,
20
-
-
... More
excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed.
(GI strip upto 7.5m including testing consider in this item).
( 06 for this schedule, 06 for Fire Fighting schedule, 02 for Fire Detection schedule & 06 for Lightening Protection Schedule )
-
-
-
... More
SCHEDULE A PART XII A (LIGHTENING PROTECTION) for details refer pdf folder
1
100274
-
... More
SCHEDULE A PART XII B (LIGHTENING PROTECTION)
-
-
-
... More
Supply & Fix test point terminal block of gun metal or phosporus bronze of size (75 x 75 x 25) mm , drilled and screwed including 3 Nos, 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
6
-
-
... More
SCHEDULE A PART XIII [AIR CONDITIONING]
-
-
-
... More
Supply, Design, Installation, testing and commissioning of Variable Refrigerant Flow VRF/VRV Central AC Plant at Ranikhet area comprising the followings:- (a) Outdoor units comprising of Energy efficient Inverter scroll compressor (100% inverter compressor), Heat Pump Type suitable for (Heating+Cooling) Top Discharge of minimum 03X22 HP two running and one standby including first charge of Eco Friendly R-410 refrigerant gas, Air Cooled Condenser with Variable Speed Condenser fan motor etc.
1
-
-
... More
(b) Double skin sandwich type air handling units (AHU).(FM/CS HORIZONTAL TYPE) of capacity minimum 4X8.5 TR fot OT, Minor OT and ICU with 25 Air Changes per hour for 2 nos OT , 12 Air changes per hour for ICU and Minor OT , comprising of 25mm thick housing with thermal break profile constructed with of 0.6 mm thick galvanized powder coated sheet on outside and 0.6 mm thick plain GI sheet inside with PUF of 43kg/m3 density insulation in between both sheets to make 25 mm thick finished panels including AHU have DIDW forward / backward curved type centrifugal fan complete with suitable size induction motor 415volts, 3 phase 50 Hz AC supply capable to provide 3500 CFM Air, Belt driven system and with vibration pads, insulated jointless stainless steel condensate drain pan, including DX cooling coils made up of 4/6 rows deep with expansion valve with AHU kit assembly including aluminium damper and Prefilter complete all as specified and directed.
-
-
-
... More
(c) Double skin sandwich type air handling units (AHU).(FM/CS HORIZONTAL TYPE) of capacity minimum 2X7 TR with 6 Air changes per hour for 2XAnaesthetics room, preoperative room, recovery room with Hot and Cool comprising of 25mm thick housing with thermal break profile constructed with of 0.6 mm thick galvanized powder coated sheet on outside and 0.6 mm thick plain GI sheet inside with PUF of 43kg/m3 density insulation in between both sheets to make 25 mm thick finished panels including AHU have DIDW forward / backward curved type centrifugal fan complete with suitable size induction motor 415volts, 3 phase 50 Hz AC supply capable to provide 3500 CFM Air, Belt driven system and with vibration pads, insulated jointless stainless steel condensate drain pan, including DX cooling coils made up of 4/6 rows deep with expansion valve with AHU kit assembly including aluminium damper and Prefilter complete all as specified and directed.
-
-
-
... More
(d) Refrigerant Pipe work for VRF System of one end expand refrigerant copper piping wit Y-joint and headers insulated with closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications, all piping inside the room shall be properly supported/fixed with suitable size of clamp or on GI hangers and PVC sleeves shall be provided wherever pipe is crossing the wall including ultra high pure Nitrogen is to be used while making breezing joints complete all as specified and directed. Dia meter and quantity for pipe shall provide by the contractor as per the approved design with out any extra cost.
-
-
-
... More
(e) GI cable tray of required size, laying horizontal and vertical with bends, reducer, tees, cross member and other accessories as required and duly suspended from the ceiling with MS threaded suspenders or fix with wall including covered the exposed area near outdoor unit with 24G thick GSS sheet metal perfect for laying the cables, drain pipe and copper piping etc complete all as specified and directed. Quantity for cable tray shall provide by the contractor as per the approved design with out any extra cost.
-
-
-
... More
(f) Aluminium sheet metal ducting of following sizes complete with hangers, Spliter Damper, vanes and all other accessories etc as required with sealing gasket for supply and return air duct from AHU to OT's & corridor area including providing flexible canvas cloth connection complete with opening of wall for supply & return air grill all as specified and directed. Size of duct and quantity shall provide by the contractor as per the approved design with out any extra cost.
(NOTE) : Cutting chases/hole in wall for inserting duct shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost.
-
-
-
... More
(g) Return air ducts with Closed Cell Elastomeric Nitrile Rubber Foam (Class - O), duly laminated aluminum foil of mat finish included acoustic lining of duct with 15mm thick open cell elastomeric material of high density duly fixed with suitable Pidilite adhesive, and also tighten with suitable size of nuts,bolts and washer conforming to standard specification complete all as specified and directed. Size of duct and quantity shall provide by the contractor as per the approved design with out any extra cost.
-
-
-
... More
(h) Refrigerant Gas R-410a after proper checking of leakage with soap solution and charging of nitrogen gas for 36 Hrs to hold the same pressure and after proper vaccumising refrigerant gas to be charge in system as required complete all as specified and directed.
-
-
-
... More
(j) Rigid PVC piping 25mm/32mm suitable for 10Kg/cm pressure of following size complete with fittings, proper U-Trap and supports and duly insulated with 6 mm thick closed cell nitrile rubber insulation, clamps for drain system complete all as specified and directed. The Quantity shall provide by the contractor as per the approved design with out any extra cost.
-
-
-
... More
(k) Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 Sqmm LT,1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20mm / appropriate dia on ceiling/surface/concealed in wall as required complete with accessories and fittings and one run of 6.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor complete all as specified and directed. The Quantity shall provide by the contractor as per the approved design with out any extra cost.
Note:- 1. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe complete all as specified and directed.
-
-
-
... More
(l) 1100 volts grade heavy duty PVC insulated, PVC sheathed multistranded coper conductor cable,16 sqmm 3 core including connecting on LT panel / out door unit VRF with suitable lugs, glands complete all as specified and directed. The Quantity shall provide by the contractor as per the approved design with out any extra cost.
-
-
-
... More
(m) Fabrication, supply, installation, testing and commissioning electrical cubical control panel board ( KIOSK TYPE ) Double door, CPRI approved an ISO 9001 factory assembled made out door pedestal type feeder pillar box whether and vermin proof fabricated of 3.0mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT's -03 Set, Phase indicator lamps with holder , toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm complete all as specified and directed. ( Feeder piller box shall be consisting the following), Qty-01 No
-
-
-
... More
(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support (b) MCCB FP 250 amps, 35/36 KA, 415 volts, 50Hz (Adjustable type) = 01 No (Incoming)
(c) MCCB TP 63 amps, 25/30 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 03 Nos (Outgoings for VRF out door unit)) (d) MCCB TPN 63 amps, 18/25 KA , 415 volts, 50Hz - 06 Nos (Outgoings for AHU's) (e) MCB SPN 63 amps, 10 KA , 230 volts, 50Hz - 02 Nos (Outgoings for HI-wall unit) (f) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set
(g) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos (h) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.
(i) RYB indicating lamp, LED type - 01 sets.
(j) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.
(k) Drawing shall be approved by GE before placing the order.
-
-
-
... More
(p) Maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter tested as per IEC 62561-7.The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity size 270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including suitable dia of medium grade GI pipe upto 7 mtr incl cutting and chases on wall and floor complete all as specified and directed. Qty-08 Nos
Note: The rate quoted above shall be deemed to be included for excavation and earth work, refilling, removal of surplus earth and making good the surface around chemical earthing. Note :- (a) The Contractor shall get complete design of AC Plant including platform duly vetted from IIT/NIT without any extra cost and to be approved by the accepting officer before execution of work.
(b) Suitable heating and humidification arrangement shall be provided by the Contractor for precise control of temperature and humidity in OT, without any extra cost.
-
-
-
... More
SCHEDULE A PART XIV ( MEDICAL GAS SYSTEM)
-
-
-
... More
Supply and fixing Oxygen Manifold 8 + 8 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes. (CE Marked) ( Indigenous)
1
-
-
... More
Supply and fixing fully Automatic Gas Control Panel for Oxygen with inlet .(CE Marked) ( Indigenous)
1
-
-
... More
Supply and fixing 1+1 Cylinders Emergency Oxygen Manifold with two stage High flow rate regulator with NRV for every cylinder and copper tail pipes .(CE Marked) ( Indigenous)
1
-
-
... More
Supply and fixing Surface Type Front Loading Gas Outlets with probes/Adaptors for Oxygen. (CE Marked) ( Indigenous)
16
-
-
... More
Supply and fixing Oxygen Flowmeter with Humidifier Bottle .(CE Marked) ( Indigenous)
16
-
-
... More
Supply and fixing H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded .Indigenous
32
-
-
... More
Supply and fixing Vacuum system V X 235 Vacuum Pumps of Ingersoll with Motor each with receiver vessel, with bacteria filter capacity Indigenous
1
-
-
... More
Supply and fixing Surface Type Front Loading Gas Outlets for Vacuum with probes/Adaptors (CE Marked) (Indigenous)
16
-
-
... More
Supply and fixing Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with bracket .(CE Marked) ( Indigenous)
16
-
-
... More
Supply and fixing Combined Electrical Control Panel for Vaccum System (Indigenous)
1
-
-
... More
Supply and fixing Nitrous Oxide 1 + 1 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes .Indigenous
1
-
-
... More
Supply and fixing 1+1 Cylinders Emergency nitrogen Manifold with two stage High flow rate regulator with NRV for every cylinder and copper tail pipes.(CE Marked) (Indigenous)
1
-
-
... More
Supply and fixingfully Automatic analog Gas Control Panel for Nitrous Oxide with inlet .Indigenous
1
-
-
... More
Supply and fixing Surface Type Front Loading Gas Outlets for Nitrous Oxide with probes/Adaptors Indigenous
1
-
-
... More
Supply and fixing Copper Pipes used will be solid drawn, 28mm OD X 1 mm thk seamless, deoxidized, non arsenical, half hard, tempered and degreased, manufactured as per EN 1057 part I, Table-X of 1971 and chemical composition as per BS-6017 of 1981, Table 2, Cu-DHP.
250
-
-
... More
Ditto as per itme 21.15 but 22 mm OD X 1 mm thick
200
-
-
... More
Ditto as per itme 21.15 but 15mm OD X 1 mm thick
100
-
-
... More
Supply and fixing Valves Boxes with Pressure Gauges as per Technical Specifications.3 Gas Services ( O2, Vac, Air 4) (CE Marked) (Indigenous)
4
-
-
... More
Supply and fixing Area Alarm as per Technical Specifications enclosed3 Gas Services ( O2, Vac, Air 4) (CE Marked) (Indigenous)
2
-
-
... More
Supply and fixing 28 mm OD Isolation Valve, as per Technical Specifications enclosed(CE Marked) (Indigenous)
4
-
-
... More
Ditto as per item No. 21.20 but 22mm OD
6
-
-
... More
Ditto as per item No. 21.20 but 15 mm OD
16
-
-
... More
Supply and fixing Horizontal Bed Head Panel (Al Extruded) 5 ft. Long Provision for Gas Outlet, Electrical Switch & Socket, Nurse Call, etc (CE Marked) (Indigenous)
16
-
-
... More
SCHEDULE A PART XV A (FIRE FIGHTING) for details refer pdf folder
1
1525044
-
... More
SCHEDULE A PART XV B (FIRE FIGHTING)
-
-
-
... More
Supply, installation, testing and commissioning fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 30m Head, 2900 RPM, 1620 LPM discharge of capacity not less than 20 HP mounted on common base plate / MS channel and PCC foundation of suitable size as per manufacturer recommondation and 400mm all around including jointing with delevery & suction with required Jointing material all as speedfied and directed.
Note: All the PCC foundation work incl base plate and MS channel work shall deemed to be included in the quoted rates.
1
-
-
... More
Supply, installation, testing and commissioning fire pump Diesel driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 30m Head,1800 RPM, 1620 LPM discharge of capacity not less than 20 HP mounted on common base plate / MS channel and PCC foundation of suitable size as per manufacturer recommondation and 400mm all around including jointing with delevery & suction with required Jointing material including the fuel tank mounted either over or adjacent to engine with capacity sufficient ot make the engine to run on full load for at least 8 Hrs all as speedfied and directed.
Note: All the PCC foundation work incl base plate and MS channel work shall deemed to be included in the quoted rates.
1
-
-
... More
Supply and Install Electric Driven Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 70 m head 180 LPM discharge of capacity not less than 10 HP all as specified and directed.
Note: All the PCC foundation work incl base plate and MS channel work shall deemed to be included in the quoted rates.
1
-
-
... More
Supply and fixing of hose box (cabinet) of size 900x900x600mm indoor type made out of 2mm thick MS Sheet with ceter opening glazed doors (4mm thick clear glass) and locking arrangement including painted with to coats of synthetic enamlled paint over a coat of red oxide primer and the word " FIRE" to painted on box, suitable for housing 2 Nos hose pipe of length 15 mtrs each with branch pipe,nozzle,coupling etc all as specified and directed.
12
-
-
... More
S&F Cast iron dual plate check valve 100mm bore, flanged type, PN-1.6, inserted to pressure 15 Kg/Sqmtr complete set all as specified and directed
6
-
-
... More
Supply and fix portable fire extinguisher 6Kg Dry chemical powder (ABC) type confirming to IS 15683
22
-
-
... More
Supply and fix PVC tank rotational moulded water storage tank of capacity 5000 ltrs including float valve(cylindrical vertiacal with closed top) hoisted and fixed in position all as specified in SSR part-I.
2
-
-
... More
Design, supply, installation, testing and commissionioning of LT Panel for fire fighting system complete with weather protected top canopy front and rear operated twin leaf doors and conforming to and tested for IEC 61439 standards and cable allay ,with locking arrangement made out of 3 mm thick sheet steel duly treated with powder coated finish, copper bus bars in enclosed chamber complete with MC100 pedastal for grounting, PCC pedastal, rubber linings for doors with including foundation complete with the following :-
1
-
-
... More
(i) Copper bus bars of capacity 400 Amps for three phases and one neutral. (ii) MCCB 4 P 350 A with adjustable thermal & magnetic release release range. Braking capacity 36 KA (for incoming) - 1 No. (iii) Ammeter digital (0-400 Amps Range) -01 Nos, Voltmeter digital (0-500 V Range) -01Nos, with control fuses ,CTs, selector switches and Phase indicators
Outgoing (iv) MCCB 4 Pole 250 A, with adjustable thermal & magnetic release release range. Braking capacity 36 KA - 01 Nos Inbuilt starter ,ML 4 type contactor for Star Delta starting for 20 HP (15 KW) - 02 set, with start and stop push button ,Digital Ammeter with CTs, selector switches, phase indicator lights, relays,phase preventer, Auxillary contacts for interlocking/ sequence of operation, control terminals, complete in all respect with interconnections for hydrant pump and sprinkler pump.
-
-
-
... More
(v) MCCB 4 Pole 63 A, with adjustable thermal & magnetic release release range. Braking capacity 25KA - 02 Nos
Inbuilt starter ,ML 1.5 type contactor for DOL starting for 10 HP (7.5 KW) - 01 set, with overload relay , start and stop push button, digital Ammeter with CTs, selector switches, phase indicator lights, Auxillary contacts for interlocking/ sequence of operation, control terminals, complete in all respect with interconnections for jockey pump & booster pump (vi) Control wiring from pressure switches of different settings in Hydrant and Jockey pump , for sequence of operation shall deemed to be included to complete the system (vii) Automatic on load Changeover 200 Amp - 01 set
Note: The panel shall be designed to facilitate the automatic operation of all the three pumps ( main pumps and jockey pump) with necessary interconnection and control wiring. The design must follow all the fire safety standards as per NBC India and any additional item/accessories required in the LT panel for smooth operation and control of the Fire fighting system, shall be incorporated by the contractor without any extra cost to the department. Nothing extra shall be paid to the contractor on this account
-
-
-
... More
M & L for connecting and testing of CI air release valve 20 mm size with ISI marked flanged type incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed.
4
-
-
... More
Supply a glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" X 6" X 8 mm decorative transparent acralic, including fixing arrangment all as specified and directed complete, all as specified and directed.
8
-
-
... More
S & F flexible connector flanged class 150, PN1.6 of size 100 mm complete with stainless steel nuts,bolts, washers & fibre/rubber gasket steel spindle complete all as specified and directed.all as specified and directed
4
-
-
... More
M&L for cutting of existing pipe line of 150 to 80 mm dia for taking branch connection alongwith insertion of GI Tee of suitable size and connection matarial
1
-
-
... More
SCHEDULE A PART XVI A (FIRE DETECTION) for details refer pdf folder
1
664194
-
... More
SCHEDULE A PART XVI B (FIRE DETECTION)
-
-
-
... More
Supply and drawing of PVC insulated FRLS as per PS conductor copper wire into the existing conduit conforming to ISI664 and duly ISI marked copper cables two core of 1.5 Sqmm size,1100 Volts
940
-
-
... More
Supply,laying and testing PVC insulated, PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 Sqmm 3 Core 1100 Volts all as specified and directed.
200
-
-
... More
SCHEDULE A PART XVII ( SHADOW LESS LIGHT)
-
-
-
... More
Supply, installation, commissioning and testing of LED based ceiling suspended double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring from and hanging arrangements as per manufacturers guidelines with following specifications :-
3
-
-
... More
TECHNICAL SPECIFICATION MAIN DOME SATELLITE DOME
Intensity @ 1 Meter (Lux) 1,60,000 + 10% 1,60,000 +10%
Adjustable Field diameter (cm) 14-38 14-38
Depth of illumination L1+L2 (cm) 100 100 Color Rendering Index (CRI) (Ra) 95 + 3% 95 + 3% Color temperature (K) 4,500 + 10 % 4,500 + 10 % Intensity control (%) 25-100 25-100
Type of field focusing control By sterllizable handle By sterllizable handle
Type of Intensity control By control panel on lamp head By control panel on lamp head
-
-
-
... More
ELECTRICAL & MECHANICAL SPECIFICATIONS
Power Supply input voltage (V) 220-230 V Power Consumption (W) 150 Frequency (Htz) 50/60 Dome Diameter 600-700 mm LED service life (hrs) 40,000 Make :- Philips/Dr Mach/Hospedia medicare/ Stryker. Note :- The contractor shall submit the details of Make/Model/Specification of the OT light for approval of GE before placing order. The Make and Model of OT light shall fulfill the requirement given here-in-before. In case of any discrepancy/ difference of opinion, the decision of Accepting officer shall be final and binding and nothing extra shall be paid on this account. Note: UPS to be paid under separate item under ser No:02.The Cost of the same is considerd in Ser item No: 26.04
-
-
-
... More
Supply,fixing, testing & commissioning of UPS of capacity 1 KVA with full load backup of 30 min and 60 min backup at 50% load, single phase AC input 160 to 260V and out put 230 V ± 1% with inbuilt isolation transformer, batteries complete all as specified and directed.
2
-
-
... More
Supply ,installation ,commissioning and testing of portable single dome operation Theater light with in compliance with medical device electric standard IEC-60601-2-41,with each dome consisting of minimum 30 LEDs and maximum 50 LEDs housed in dome with diameter ranging between 500-700 mm with spring arm system to provide precise positioning of the OT light as required during surgery complete with sealed maintenance free batteries to provide instantaneous backup in case of power failure for 60 minutes complete with all necessary wiring for hanging arrangement as per manufacturers guidelines with following specification :-
1
-
-
... More
TECHNICAL SPECIFICATION DOME Intensity @ 1 Meter (Lux) 1,60,000 + 10% Adjustable Field diameter(cm) 14-38 Depth of illlumination L1+L2(cm) 100 Rendering Index (CRI)(Ra) 95+3 % Colour temprature(K) 4500+10% Intensity control(%) 25-100 Type of Field Focusing control By Sterilizable handle Type of Intensity control By Control panel on lamp head ELECTRICAL AND MECHANICAL SPECIFICATIONS Power Supply input Voltage (V) 220-230V Frequency (Htz) 50/60 Dome Diameter 500-700 mm LED service life (hrs) 40000
-
-
-
... More
SCHEDULE A PART XVIII A (PUBLIC ADDRESS SYSTEM) for details refer pdf folder
1
49726
-
... More
SCHEDULE A PART XVIII A (PUBLIC ADDRESS SYSTEM)
-
-
-
... More
Supply and fix Control Console for public address system for amplifier, microphone and speaker control incl all connecting accessories all as specified and directed.
1
-
-
... More
SCHEDULE A PART XIX A (LIFT) for details refer pdf folder
1
26469
-
... More
SCHEDULE A PART XIX A (LIFT)
-
-
-
... More
Supply, install, testing & commissioning traction passenger elevator (lift) , Electrically operated with microprocessor based full simpelx colletive control 8 Passenger, 544 Kgs lift suitable to serve G+2 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors grade 304, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below and all as per IS-14665 & IS-15785 :-
Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 before dispatch of material from OEM for approval of GE.
(ii) The scope of work also covered the civil work comprising cutting of holes and making good. car and counter weight guide rails and bracket, terminal buffers supports and sill angle, plates and any other items required for successfull completion of lift with respect to safety required by the OEM, will be carried out by contactor without any extra cost.
1
-
-
... More
(iii) The contractor shall be responsible for 2 years defect laibility period from certified date of completion of GE. During the said defect liability period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor for operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years defect liability period.In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement will be made between contractor & OEM ,and this shall be submitted to GE on the date of handing over of lift for the comprenssive maintenance of defect liability period. The cost of above shall be deemed to be included in the quoted rates. (iv) The provision of suitable steel structure/ palteform for installation of lift equipment is part of lift item and nothing extra shall be paid.
(v) If any clearance required from state goverment i.e. lift inspector/ electrical safety department/ fire safety departments is the contactor's responsibility & any expenditure on this account shall deemed to be included in the quoted rates.
-
-
-
... More
BASIC DATA / TECHNICAL SPECIFICATION
(a) Type of Lifts : Passenger machine room less type
(b) Load & capacity : 544 Kgs/ 08 Persons
(c) Speed : 1.00/ mtr/sec (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Machine : 3 Phase Single speed Electric Motor lift duty reversible with gear etc (f) Stops and openings : 3 Stops and 3 openings, Single entrance Car.
(g) Travel hight : 3 Floor of building.
(h) Grouping/Operation : Simplex, Full collective.
(j) MAP Floor position : Top most floor.
(k) Car size : 1100 mm wide x 1300 mm deep x 2200 mm height or as per IS and suitable to install.
(l) Door size : 800 mm wide x 2000 mm height or as per IS and manufacturer specification.
(m) Door type : Two- panel Centre opening , telescopic stainless steel 304 grade with Air vent, automatic operated door.
-
-
-
... More
(n) lift well size 1900x1900mm, pit depth-1600mm or over head 4200mm.
(o) Indicators : Car position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor with dot red led scrolling display. (p) Traction media : Round stranded steel wire rope confirming to IS-14665-2000 or as per manufacturer specification with gaurds. (q) Call register type micro push button for opening and closing of doors.
-
-
-
... More
FINISHES
(a) Car design : Stainless steel 340 hair line finish/mirror polished
(b) Car panel finish : Mirror polished stst./hair line stainless steel
(c) Hand rail : Round bend hand rail stainless steel at rear wall.
(d) Ceiling and lighting : Integrated Roof RL20 Stainless Steel Ring Lighting LED.
(e) Flooring : 20 mm Reecess and granite stone.
(f) Car door finish : Stainless steel hairline finish AISI441 with fire raitng 60 min.
(g) Landing door mark : Floor Number - G to 2, Floor mark G,1,2, Landing door material- Stainless steel grade 304 hairline finish with fire rating 1 hrs.
(h) Car opening panel : Full Height Stainless Steel Face Plate Silver brushed StSt,Segmented LED display Square surface mounted Buttons KDS90, Tempered glass segmented display (j) Landing signalization : Stainless Steel 7 segment display Flush Mounted Silver brushed StSt Square,surface mounted KDS90
-
-
-
... More
STANDARD SAFETY FEATURES/DEVICES
(a) Car emergency light, Fireman drive, Curtain of light, Accurate relevelling, Automatic closed door.
(b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED.
(c) Digital direction and position indicator in car and at all landings.
(d) Emergency alarm at the main landing with alarm bell button in car.
(e) 2 Phase/2 way fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door)
(f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed)
(g) Additional pressure sensing device.
(h) Load weighing device ( Audio visual over load indicator in the car for better safety)
(j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car). (k) Pit ladder ( To ensure safety of the maintenance personnel).
-
-
-
... More
(l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency)
(m) Over speed governor ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction)
(n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors).
(o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LED display.
(p) Mechanical rescue device with no dependence with battery.
(q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Door time protection with extra door time for lobby and parking, auto fan cut off. (s) Mirror on rear side wall and voice synthesizer.
(t) Controller shall be include protection against over current,over voltage, single phasing, phase reversal, earth leakage and interlocking with door opening, closing and moment of lift and any other operation required for the safety of passenger as per fire safety regulation pertainging to lift. (u) Emergancy stop button with alarm. (v) Two position key operated switch with attended and without attended switch mode. (w) Any other accessories / safety device required as per IS for safety of passengers.
-
-
-
... More
Supply, install, testing & commissioning traction passenger elevator (lift) Electrically operated with microprocessor based full simpelx colletive control 15 Passenger, 1020 Kgs lift suitable for hospital stretcher to serve G+2 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel 304 frame with temepred laminated saftey clear vission glass door, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below and all as per IS-14665 & IS-15785 :-
Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 before dispatch of material from OEM for approval of GE.
(ii) The scope of work also covered the civil work comprising cutting of holes and making good. car and counter weight guide rails and bracket, terminal buffers supports and sill angle, plates appron/Toe/Tension pulley and any other items required for successfull completion of lift with respect to safety required by the OEM, will be carried out by contactor without any extra cost.
1
-
-
... More
(iii) The contractor shall be responsible for 2 years defect laibility period from certified date of completion of GE. During the said defect liability period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor for operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years defect liability period.In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement will be made between contractor & OEM ,and this shall be submitted to GE on the date of handing over of lift for the comprenssive maintenance of defect liability period. The cost of above shall be deemed to be included in the quoted rates. (iv) The provision of suitable steel structure/ palteform for installation of lift equipment is part of lift item and nothing extra shall be paid. (v) If any clearance required from state goverment i.e. lift inspector/ electrical safety department/ fire safety departments is the contactor's responsibility & any expenditure on this account shall deemed to be included in the quoted rates.
-
-
-
... More
BASIC DATA / TECHNICAL SPECIFICATION
(a) Type of Lifts : Passenger machine room less type
(b) Load & capacity : 1020 Kgs/ 15 Persons
(c) Speed : 1.00/ mtr/sec (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Machine : 3 Phase geared Single speed Electric Motor lift duty reversible type with gear sleeve and machine drive etc (f) Stops and openings : 3 Stops and 3 openings, Single entrance Car.
(g) Travel hight : 3 Floor of building.
(h) Grouping/Operetion : Simplex, Full collective.
(j) MAP Floor position : Top most floor.
(k) Car size : 1000 mm wide x 2400 mm deep x 2200 mm height or as per IS and suitable to install.
(l) Door size : 800 mm wide x 2000 mm height or as per IS and manufacturer specification.
(m) Door type : Two- panel Centre opening , telescopic stainless steel grade 304 frame partially with laminated tempered (saftey clear vision glass size 400x900x16 mm thick(8+8mm), automatic operated door.
-
-
-
... More
(n) lift well size 1800x2800mm, pit depth-1600mm or over head 4200mm.
(o) Indicators : Car position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor with dot red led scrolling display. (p) Traction media : Round stranded steel wire row confirming to IS-14665-2000 or as per manufecturer specification with gaurds. (q) Call register type micro push button for opening and closing of doors. (r) Control unit : Micro Processor based control unit.
-
-
-
... More
FINISHES
(a) Car design : Stainless steel 340 hair line finish/mirror polished
(b) Car panel finish : Stainless steel Hairline AISI441
(c) Hand rail : Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall
(d) Ceiling and lighting : Integrated Roof RL75 Painted Gentian blue Pyramid Lighting LED.
(e) Flooring : 20 mm Reecess and granite stone.
(f) Car door finish : Stainless steel hairline finish with fire raitng 60 min.
(g) Landing door mark : Floor Number - G to 2, Floor mark G,1,2 Landing door material- Stainless steel grade 304 hairline finish with fire rating 1 hrs.
(h) Car opening panel : Full Height Stainless Steel Face Plate Silver brushed StSt Segmented LCD display Square surface mounted Buttons KDS90
(j) Landing signalization :Stainless Steel 7 segment display Flush Mounted Silver brushed StSt Square,surface mounted KDS90
-
-
-
... More
STANDARD SAFETY FEATURES/DEVICES
(a) Car emergency light, Fireman drive, Curtain of light, Accurate relevelling, Automatic closed door.
(b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED.
(c) Digital direction and position indicator in car and at all landings.
(d) Emergency alarm at the main landing with alarm bell button in car.
(e) 2 Phase/2 way fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door)
(f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed)
(g) Additional pressure sensing device.
(h) Load weighing device ( Audio visual over load indicator in the car for better safety)
(j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car).
(k) Pit ladder ( To ensure safety of the maintenance personnel).
-
-
-
... More
(l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency)
(m) Over speed governor with brakes ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction)
(n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors).
(o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LED display.
(p) Mechanical rescue device with no dependence with battery.
(q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Door time protection with extra door time for lobby and parking, auto fan cut off. (s) Mirror on rear side wall and voice synthesizer.
(t) Controller unit shall be include protection against over current,over voltage, single phasing, phase reversal, earth leakage and interlocking with door opening, closing and moment of lift and any other operation required for the safety of passenger as per fire safety regulation pertainging to lift. (u) Emergancy stop button with alarm. (v) Two position key operated switch with attended and without attended switch mode. (w) Any other accessories / safety device required as per IS for safety of passengers.
-
-
-
... More
Supply and fix, Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head light fitting, 10 w, IP66, 230V, 50 Hz, complete with all ccessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr in Charge.
9
-
-
... More
M & L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 2.25 mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board/panel , watering pipe 20 mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaining surplus excavated material all as directed at site and specified in EP No 3 of SSR part I, complete all as specified and as directed by Engr-in-Charge.
6
-
-
... More
Providing manpower & operation of 2 x pessenger lifts at Clement town military station by providing manpower 01 x Un-skilled lift operator per shift in a day for 8 hrs including Sunday & holiday and carrying out minor regular / periodical repaires and regular servicing for upkeep thepassenger lift serviceable in all respect, checking of oil levels, thorough checking of lift, make the machinery /equipment dust free, including thorough cleaning up of battery terminals of ARD unit, greasing/oiling of moving parts, leak testing etc all as specified and directed by the Engineer-in-charge. (Note:- (i) The duration of work will be carried out in three shifts from 0600 hrs to 1400 hrs (First Shift), 1400 hrs to 2200 hrs (Second Shift) and 2200 hrs to 0600 hrs ( Third Shift). (ii) The duration of work will be carried out in three shifts of 08 hrs of each shift by deploying the manpower 01 x Un-skilled lift operator in each shift (Total 03 operators in one day) to operate the 02 Nos automatic lift ( 01 x 08 passengers & 01 x 13 Passenger) in one high rise tower of G+6 storey). [24 months for DLP & 36 Months after DLP]
60
-
-
... More
Comprehensive maintenance of all mechnical & electrical components & conduct a thorough inspection of the fully automatic 02 x passenger lift's ( 01 x 08 passengers & 01 x 13 Passenger) in one high rise tower of G+6 storey) with mechnical & electrical systems, including motor, cables, brakes, control panels & wiring. Identify any signs of wear, drainage or carring out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair / maintenance of unserviceable parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door sills, door locks, control cards and its contacts, hall push buttons and its spares, connector / links, welding of crack/broken and MS parts,kanding operating panel of any size & capacity, repair / maint of u/s damaged door safety edge & sensor mechnical safety locks, megnatic lock of contact, car position indicator & all connected accessories, necessary wiring of hall push button assembly, repair/ mantenance of broken COP/LOP buttons &
36
-
-
... More
display including cover, fire alarm, firemen button glass, intercom, alarm/hooters, maintenance of damged hand rail shaft, light / switches , complete with illuminated push button & direction indicator with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors & safe operation of lifts, fixing of loose rail brackets if any, cabin mirror light & minor repair of cabin fan, ensure safe & smooth functioning of lift & complete maintenance of car top, binding of loose wire at control panel & rust painting at car top and door, dewatering of lift well in case of any emergency arise all as directed by Engineer-in-charge. [ 36 Months after DLP]
-
-
-
... More
SCHEDULE A PART XX (UPS)
-
-
-
... More
Supply,fixing, testing & commissioning of UPS of capacity 10 KVA with full load backup of 30 min and 60 min backup at 50% load, three phase AC input 300 to 450V and out put 415 V ± 1% with inbuilt isolation transformer incl batteries(12V-26/28 AH) with DC bus 192 VDC and battery capacity 4992 VAH incl battery rack, interlink connector ,cable for input and output connections and paralleling kit for synchronising complete all as specified and directed.
2
-
-
... More
Supply only emergency rechargeable LED light 15 W with 7200 mAH battery with brightness control feature and in built mobile charging point.
2
-
-
... More
SCHEDULE A PART XXI A (REFRIGERATOR AND RO PLANT) for details refer pdf folder
1
29455
-
... More
SCHEDULE A PART XXI B (REFRIGERATOR AND RO PLANT)
-
-
-
... More
Supply and fix refrigerator, medical grade with external temperature display and fully electronic temperature control, control panel with audible & visual alarm in case of any temperature change with extractible drawers inside the cabinet which can be adjustable & removable incl partitions for rational storage of medicines, reversible glass door, integrated lock, BEE 5 star rated electric driven,capacity 375 Litres all as specified and directed
2
-
-
... More
Supply and fix Reverse Osmosis Plant of out put capacity of 100 Litres per hour with 6 stage water purifier and automatic operation, suitable for wall mount or countertop having antibacterial,silver dose, taste enhancer and activatrd carbon filter for the post water treatment.The RO Plant should be energy efficient and durable with advanced RO technology and made out of high quality material that is resistant to corrosion and wear & tear incl PCC work for plinth and monkey caging all around as reqd at site.
1
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0.5 KVA
2
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA
2
-
-
... More
M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
45
-
-
... More
SCHEDULE A PART XXII (DEMOLITION) for details refer pdf folder
1
114523
-
... More
Note : Tenderers may note that amount of credit Rs 55,254.44 will be deducted from the total amount arrived, at the time of Acceptance of contract.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%