Military Engineer Services Tender
View complete overview of Uttarakhand MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date9 Oct 2024
Closing Date4 Dec 2024
Tender Amount₹ 2,48,94,000
Costs
EMD
₹ 8,16,500Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678779_1Tender No
CEBZ/PGH/T-08 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SCHEDULE A PART III B (INTERNAL ELECTRIC SUPPLY)
-
-
-
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed/ surface PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule)
-
-
-
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
25
-
-
(b) One three pin 5 Amp socket on same board with other switches.
1
-
-
(c) One three pin 5 Amp socket on independent board
3
-
-
All as per item No-5 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
3
-
-
S&F DB TPN, 415 volt with 250 amps rated copper bus bar for double door 4 way IP-54, IK-09 suitable for one MCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
1
-
-
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
1
-
-
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
1
-
-
S&F MCB SP, 5 to 32 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
20
-
-
S&F MCB SPN, 40 to 63 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
2
-
-
S&F MCB TPN, 63 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
1
-
-
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 1.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 1.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
20
-
-
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 2.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 2.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
25
-
-
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings with chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
20
-
-
M&L sub main wiring in replacement with 4 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 25 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 10.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
30
-
-
Supply & fixing LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders, including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
12
-
-
Supply & fix LED light fitting high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders, including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed.
1
-
-
Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with squirrel cage induction motor complete all as specified and directed.
1
-
-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 miters below normal ground level, connected to galvanised earth wire 4 sqmm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
2
-
-
Supply, installation, testing and commissioning of Water Heater Storage Type five star rating, electric suitable for single phase ,50HZ, AC supply, stainless steel inner assembly, 2 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 25 ltrs capacity.
1
-
-
Supply, fix, connecting and testing building LED security light fitting 35 W with pressure die cast aluminium housing, heat resistant toughened glass, IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
7
-
-
Supply and fix exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers
1
-
-
Supply and fix exhaust fan steel body AC single phase 230 V of size 450 mm sweep heavy duty with blades and frame and louvers
2
-
-
Total amount of Sch 'A' Part IV Site Clearance & Earth) (For details see Sch 'A' in PDF folder)
1
-
1944336.48
Total amount of Sch 'A' Part V Path) (For details see Sch 'A' in PDF folder)
1
-
76318.2
SCHEDULE A PART V B (Path)
-
-
-
M&L for chequered cement cement concrete tiles of size 30cmx 30cm x 25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 15mm thick screed bed or bedding layer of CM 1:6 complete all as specified and directed
1305.59
-
-
Total amount of Sch 'A' Part VI Retaining Wall) (For details see Sch 'A' in PDF folder)
1
-
859791.61
Total amount of Sch 'A' Part VII Area Drainage) (For details see Sch 'A' in PDF folder)
1
-
282215.4
Total amount of Sch 'A' Part VIII A Sewage Disposal) (For details see Sch 'A' in PDF folder)
1
-
107131.86
SCHEDULE A PART VIII B (Sewage Disposal)
-
-
-
M&L for conventional RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, Baffle walls, and roof slab including beams etc with vent shaft, manhole opening with cover connection etc complete with effective depth of 1.5m and overall depth of 3m for 20 users.
1
-
-
M&L for soakage well with size 1.80m x 3.00 m effective depth including excavation in any type of sol, foundation in PCC 1:3:6 walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in cement mortar , RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.
1
-
-
Total amount of Sch 'A' Part IX A External Water Supply) (For details see Sch 'A' in PDF folder)
1
-
203706.8
SCHEDULE A PART IX B (External Water Supply)
-
-
-
Supply, install, testing and commissioning factroy assembled 23.86 WHP(50 HP) centrifugal pump horizontal split casing type suitable for of CI body and CI impellers with suitable squirell cage electric motor 3 phase 1450 RPM 50 Hz complete with auto . Pump set suitable for water supply 670 LPM and head 180mtr fixed on new MS base frame and PCC foundation as per manufacturer's instructions.
2
-
-
Supply & Fix Cast Iron reflax valve of size 100 mm bore class PN-1.6, long body type, with brass spindle, both ends flanged with holes, provision of nuts, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains complete all as specified and directed.
2
-
-
Constructions of brick masonry valve pit of size 900mmx900mmx900mm (internal dimensions) one brick thick wall in cement mortar (1:4) on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation, 15mm thick rendering internally, externally up to 15 Cms below GL provision of valve pit cover made out of 3mm thick MS plate welded with 40 x 5mm thick F1 frame all round including provision of hinges, handles, locking arrangement, ISA 40 x 40x 5mm frame, fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1 (Block size 230 x 200 x 100mm) including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) and necessary earth work in soft/loose soil complete all as specified and directed.
14
-
-
Constructions of brick masonry Chamber of size 1500mmx1500mmx1500mm (internal dimensions) one brick thick wall in cement mortar (1:4) on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation, 15mm thick rendering internally, externally up to 15 Cms below GL provision of valve pit cover made out of 3mm thick MS plate welded with 40 x 5mm thick F1 frame all round including provision of hinges, handles, locking arrangement, ISA 40 x 40x 5mm frame, fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1 (Block size 230 x 200 x 100mm) including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) and necessary earth work in soft/loose soil complete all as specified and directed.
2
-
-
S&F Cast iron Air release valve (ARV) valve with double air outlets conforming to IS 14845 of size 50 MM bore and fixing up in GI Water supply mains of size 150mm dia and drilled including bolts, nuts, washers, gasket etc complete all as directed by Engr-in-Charge.
1
-
-
S&F cast iron Air release valve (ARV) valve 100 MM dia complete conforming to IS 1484 double flanged and drilled including bolts, nuts, washers, gasket etc complete all as directed by Engr-in-Charge.
1
-
-
Supply and Fixing gun metal foot valve 100 mm (4" dia) complete all as directed by Engr-in-charge.
2
-
-
Supply, install, testing and commissionning altoch dosing system (Model ADS-1) non metallic tank 100 litres capacity with motor dirven agitator to maintain uniform suspension throughout the tank , electrically operated chlorine dosing tan consisting of dosing tank 100 ltrs of FRP MEC with FRP Lid and levels gauge alonwith single phase electric motor and agitator with shaft & blade in plstic mounted on tank lid must have port hole for pouring calcium hypochlorite and water when necessary . lid must have provision for mounting dosing pump on the lid/ wall. Make : DECLIBAC.
1
-
-
Supply, install, test and commissioning decrin dosing pump Model 96 NGQ51 high pressure single head gear motor, adjustable dosing pump with accessories and suitable electrical connections of following specifiations adjustable high pressure 0 to 100 PSI, power 230V, 50 Hz, RPM-44, HP-1/30 fractional, out put : 2 US.GPD to 40 US GsPD, Make : DECLIBAC at water supply installations.
1
-
-
M&L For cutting hard standing/Road For laying pipe by means of mannual digging/ Cutting and making good the disturbed surface complete all as specefied.
14.8
-
-
Supply and lay in trenches or passing through pipe/fixed to wall/pole and duct cablePVC insulated , amoured heavy duty electric cable with Copper conductor , 1100 volt grade ,cross sectional area 25 Sq mm 3 Core all as specified and directed.Make : Havells/Polycab/Gloster
30
-
-
Supply and fixing standard automatic star delta starter 3 phase , 415V suitable for centrifugal water pump of capacity 50HP(37.5KW) with overlaod relay range 55-70 Amps incased in SS enclsoure suitable for fixing on wallb complete all as specified and directed. Make Havells/ C&S/ Legrand
2
-
-
Supply and lay pipe galvanized , '' Heavy class " including fittings 100mm (4") dia bore complete all as specifed and directed.
1410
-
-
Supply and lay pipe galvanized , '' Medium class " including fittings 150mm (6") dia bore complete all as specifed and directed.
1040
-
-
Supply and lay pipe galvanized , '' Medium class " including fittings 100mm (4") dia bore complete all as specifed and directed.
100
-
-
Supply & Fix Cast Iron sluice valve of size 100 mm bore class PN-1.6, long body type, with brass spindle, both ends flanged with holes, provision of nuts, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains complete all as specified and directed.
12
-
-
Supply & Fix Cast Iron sluice valve of size 150 mm bore class PN-1.6, long body type, with brass spindle, both ends flanged with holes, provision of nuts, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains complete all as specified and directed.
2
-
-
M/L for CI Non Return sluice valve 100 mm dia, complete and drilled including bolts, nuts, washers, gasket etc complete all as directed by Engr-in-Charge.
2
-
-
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site.
4
-
-
Total amount of Sch 'A' Part X External Electric Supply) (For details see Sch 'A' in PDF folder)
1
-
447252.79
SCHEDULE A PART X B (External Electric Supply)
-
-
-
M&L local sand dry, filling in trenches around under ground cable all as specified and directed.
Note :- For the purpose of payment only punned thickness will be measured.
51.03
-
-
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
5.1
-
-
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site.
6
-
-
Supply and fixing steel tubular swaged pole 9 Mtrs long type 410 SP- 31 ISI marked final taper plug, bolts, nuts & screws including painting of pole with two pole of Aluminium paint over a coat of red oxide primer including 30 cm alternate step of black and yellow paint up to height of 1.5 Mtrs from top of PCC coping complete with base plate of MS sheet 30 cm x 30 cm x 6 mm thick welded at the bottom of pole
8
-
-
Supply and fix pole box size 450 x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed.
8
-
-
Supply and fix in replacement of bracket made out of GI tubing single piece not wleded bended at proper angle of size 40mm dia,light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide to the bracket etc complete.including 1.0 sqmm 3.0 core flexible Copper cable in PVC conduit with clamp from juction box to connecter of street light fitting.
8
-
-
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
8
-
-
Supply, install, testing and commissioning of LT Panel board ,CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following:
Contd......
1
-
-
On load change over switch 4P, 415Volts, of capacity 125Amp -01 Nos MCCB 4 pole 125 Amps 25 kA - 01 Nos
MCCB 4 pole 100 Amps 25 kA - 02 Nos
MCCB 2 pole 40 Amps 16 kA - 01Nos
MCB 2 Pole 20 Amp 10 KA -02 Nos Multifunctional VAF meter, PF meter - 1 No
B Neon indicating lamp -1 set for each outgoing and incoming MS work incl angle iron frame and PCC work
Space for mounting of additional MCB In future.
Note : Bottom portion of panel should be 90 CM above from the ground level.
-
-
-
DG SET
-
-
-
"1.Supply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 100 KVA, 3 phase 0.8 power factor, 50 Hz,developing 156 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Joshimath and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :-
Make : Kirloskar / Ashok Leyland/ Ruston/Cummins
" Contd....
1
-
-
"(A) Alternator :-
Synchronous alternator rated at 100 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-
(a) +-1% voltage regulation (max) in static conditions. (b) IP: 23 protections with class ‘H’ insulation. · (c) Permanent lubricating bearing. · (d) Permissible overload of 10% for one hour in 12 hours of operation. " Contd....
-
-
-
"(B) Diesel Engine: - Adquate capacity of Diesel engine liquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Liquid pump : - Centrifugal type belt driven.
iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential type
v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hoses
vi) Lub oil System :- Lubricating oil filter,Lubricating oil pump
vii) Air Intake System :- Air intake Manifold,Air cleaner dry type
viii) Governer : Electronic type
ix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.
x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 01 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. Contd..
"
-
-
-
"xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.
xii) Safety Controls : - Engine low lube oil pressure, high coolant temperature and over speeding of engine.
xiii) Coupling arrngement : - Flexible coupling
xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.
xv) Base Frame : - Base frame is fabricated either in ISMC or in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete set i.e. along with canopy, engine and alternator.
xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.
xvii) Battery Charger shall be provided as per manufacturer guidelines.
xviii) 1 No battery of 12 V in charged condition with its leads. Contd....
-
-
-
"C) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility.
(i) Manufactured by OEM suitable for 100 KVA DG Set.
(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battery should be inside the enclosure.
(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.
(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.
vi) The acoustic should be composite in construction and fully assembled integral unit.
vii) The DG Set should be provided with external Emergency stop push button.
viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.
ix) The noise level should be 75 dB at 1m under free field conditions.
x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
Contd....
-
-
-
"D) Control Panel :- Control panel shall be fabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:
(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.
(ii) Instrument fuses and control wiring. (iii) Indication lamps set for running and load on.
(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. " Contd....
-
-
-
E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. Contd....
-
-
-
"F) Civil Works :-
All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint work and related foundations for panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.
Note:- The contractor shall arrange artificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.
" Contd...
-
-
-
"Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.
(ii) Circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.
(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.
(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.
(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.
vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved from Engr-in-charge/GE before placing final order to the manufacturer.
vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.
viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.
ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set ." Contd....
-
-
-
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Contd....
6
-
-
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3 1/2 core.
30
-
-
Total amount of Sch 'A' Part XI A Filter Bed 200000 Ltr) (For details see Sch 'A' in PDF folder)
1
-
469738.36
SCHEDULE A PART XI B (Filter Bed 200000 Ltr)
-
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 40mm to 60mm graded.
13.77
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 20mm to 40mm graded.
2
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 10mm to 20mm graded.
2
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 5mm to 10mm graded.
2
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 2mm to 5mm graded.
2
-
-
Supply only Aggregate of broken sotne of loose filling, of gauge 0.75mm dia graded.
2
-
-
M&L for apply two coat of flexible elastic water proofing & protection coating of 1.50mm to 2mm thick using 2 component cement base water proofing materials (PIDI FIN 2K M/S PIDILITE & BRUSH BOND- M/S FOSRCC AS PER MANUFACTURER'S instruction
19.53
-
-
Total amount of Sch 'A' Part XII A Sedimentation Tank) (For details see Sch 'A' in PDF folder)
1
-
1153886.08
SCHEDULE A PART XII B (Sedimentation Tank 25000 Ltr)
-
-
-
M&L for 200mm PVC water bar for RCC work complete all as specified and directed.
121.6
-
-
M&L for apply two coat of flexible elastic water proofing & protection coating of 1.50mm to 2mm thick using 2 component cement base water proofing materials (PIDI FIN 2K M/S PIDILITE & BRUSH BOND- M/S FOSRCC AS PER MANUFACTURER'S instruction
67.98
-
-
Total amount of Sch 'A' Part XIII A Collection Chamber 5000 Ltr) (For details see Sch 'A' in PDF folder)
1
-
406325.19
SCHEDULE A PART XIII B (Collection Chamber 5000 Ltr)
-
-
-
M&L for 200mm PVC water bar for RCC work complete all as specified and directed.
83
-
-
M&L for apply two coat of flexible elastic water proofing & protection coating of 1.50mm to 2mm thick using 2 component cement base water proofing materials (PIDI FIN 2K M/S PIDILITE & BRUSH BOND- M/S FOSRCC AS PER MANUFACTURER'S instruction
7.56
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%