Military Engineer Services Tender

View complete overview of Uttarakhand MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Mar 2025
Closing Date26 Mar 2025
Tender Amount₹ 60,00,700 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.

8.19

-

-

... More
M&L for cement concrete (1:4:8), type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed

18.97

-

-

... More
Use and waste of formwork for sides of concrete foundation footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter roughed finished surface of concrete complete all as specified and directed.

111

-

-

... More
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. finished fair and even complete all as specified and directed.

92

-

-

... More
Use and waste for form work to sides of pillars, posts, struts columns, square, rectangular or polygonal etc finished fair and even complete all as specified and directed.

119

-

-

... More
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

4634

-

-

... More
All as per item No 10 here-in- before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.

2106

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed.

27

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed.

12

-

-

... More
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.

11

-

-

... More
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.

57

-

-

... More
M &L for Rendering 5 mm thick CM 1:3 on fair faces of brick or concrete surfaces finished even & smooth ( without using extra cement) complete all as specified and directed.

207

-

-

... More
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.

32

-

-

... More
M&L for 10mm thick rendering on fair faces of brick work or concrete surface in cement plaster (1:6) finished the surface even and smooth (without using extra cement) complete all as specified and directed.

8

-

-

... More
Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.

5

-

-

... More
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.

40

-

-

... More
M & L for preparation of newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.

207

-

-

... More
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.

133

-

-

... More
M&L for hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed

61.75

-

-

... More
M&L for 100 mm thick plain cement concrete (1:4:8), type D-2 (using 40mm graded stone agg as in sub base filling and mass concrete complete all as specified and directed.

565

-

-

... More
M&L for 40 mm thick PCC (1:2:4) type B1, (20 mm graded stone agg) as in sub base filling and mass concrete complete all as specified and directed.

460

-

-

... More
M&L for Machine cut kota stone slab flooring 20-25mm thick laid over and including 20 mm thick screed bed in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.

460

-

-

... More
M&L for machine cut Kota stone slab 20-25 mm thick as in vertical surfaces such as risers of steps, skirting, dado etc over and including 10mm cement screed bed laid in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing complete all as specified and directed.

76

-

-

... More
M&L for75 mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed. Note : Joint to be provided at each interval of 3m and corner and cost of the same deemed included in quoted rate.

77

-

-

... More
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.

7476

-

-

... More
S&F mild steel plate (plain or chequered) channels,square cut or notched (ordinary and counter sunk ) forming holes, with riveted,bolted or weleded attachement confirming to Fe- 410-W (Gde E-250) quality A complete all as specified and directed.

193

-

-

... More
S & F mild steel screw bolts 16 to 20mm dia ( Machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nuts exc 15 cm and n exc 22.5 cm long, complete all as specified and directed

52

-

-

... More
S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 steel with and including necessary drilling holes etc complete all as specified and directed. Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account.

431

-

-

... More
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified

145

-

-

... More
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

521

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.

58

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete.all as specified and directed

103.59

-

-

... More
Removing surplus excavated material to a distance exc 250 m and not exceeding 500m & depositing where directed at a level n.exc 1.5m above the starting point complete.all as specified and directed.

214.64

-

-

... More
M&L for second class hard wood (sal) in timber scantling (clean sawn) as in framed work, roof truss etc complete all as specified and as directed.

0.71

-

-

... More
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed.

9.6

-

-

... More
M&L for 60 mm thick coloured rubber moulded glossy finish machine pressed precast concrete interlocking paver block, M-35 Grade with grey cement & pigment any shape and size confirming to IS 15658-2006 with and including over 25 mm thick sand cushining complete all as specified and directed.

105

-

-

... More
M & L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerb or mud stop, coping rounded or chamfered on edges complete all as specified and directed

3.51

-

-

... More
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in surface channel and drain including saucer drain and toe wall etc complete all as specified and directed.

2.37

-

-

... More
M&L for brick work with old size half brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.

94.98

-

-

... More
M&L Bricks, sub class B, laid on edge in floors old size bricks Bedded and jointed in Cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed.

47.49

-

-

... More
M&L for Keyed pointing to brick walls in cement mortar 1:3 complete all as specified and directed.

9.5

-

-

... More
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including surface rigid PVC conduit not less than 20 mm dia (Color coding of wires shall be phase, neutral and earth wire all as specified) with its accessories sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-

-

-

-

... More
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.

43

-

-

... More
One 5/3 pin 6 Amps socket controlled by one switch on same board.

2

-

-

... More
One 5/3 pin 6 Amps socket controlled by one switch on independent board.

4

-

-

... More
Descrition same all as per item No 45 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.

4

-

-

... More
S&F Switch piano flush type 230 Volts AC single pole, one way 5/6 Amps ISI Mark all as specified and directed.

47

-

-

... More
S&F Switch piano flush type single pole, one way 15/16 Amps all as specified and directed.

4

-

-

... More
S&F Socket outlet flush type 3/5 pin 5/6 Amps 230V AC all as specified and directed.

6

-

-

... More
S&F Socket outlet flush type 5/6 pin 15 Amps 230V AC all as specified and directed.

4

-

-

... More
S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed.

22

-

-

... More
S&F integral well glass luminarie 40 Watt with die cast canopy and gear housing with both eye bolt and cradle for multiple mounting options IP-66 protection working on 240 volts 50 HZ consisting of reflective lens wired with appropriate driver r 0.95 having overvoltage protection up to 440 volts, surge protection level , level 7-10 KV thermal short circuit ptotection THD10%, made up of long life LED chips (SMD) in modular with Ra70 and lumen effieiency 120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed.

21

-

-

... More
S&F LED Street light 35 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection having clamp for mounting on building wall working on 240 volts, 50 Hz,wired with appropriate driver PF 0.98 having overvoltage protection upto 440 volt, surge protection level 10 KV, thermal short circuit prtection THD 10% made up of long life LED chip (SMD) in modular with Ra 70, and LED lumen efficiency 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and directed. Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory. (iii) The fiitting should have BIS , CRS No(iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.

8

-

-

... More
S&F ceiling fan of 1400mm sweep min air delivery 210 CFM with service value 6.00 BEE Five star rated BLDC and connecting up including provison of three core flexible cable of size 1.5 Sqmm copper wire from ceiling rose/connector to fan of length not less than 0.5 mtr, down rods, electronic regulator. complete all as specified and directed.

14

-

-

... More
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified & directed.

2

-

-

... More
S & F MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.

12

-

-

... More
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.

2

-

-

... More
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.

-

-

-

... More
2x6 Sqmm + 1x6 Sqmm earth wire with PVC conduit 20mm dia

45

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.

2

-

-

... More
S&F OFF load change over switch 415 V in sheet metal encosures 4 pole of capacity 63 Amp complete all as specified & directed.

1

-

-

... More
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated, PVC sheathed, steel armoured, aluminum stranded conductor LT UG cable (Conforming to IS 7098), ISI marked, in trenches / ducts / through GI pipes under roads of following size complete all as specified and directed:- Note:- 1. The earth work, GI pipe shall be measured and paid sepretely. 2. Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc.

-

-

-

... More
16 Sqmm, 2 core.

65

-

-

... More
M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose.

4.21

-

-

... More
S&F galvanized steel water tubing (GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :- Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.

-

-

-

... More
40mm bore

12

-

-

... More
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.

0.45

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.