If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Uttar Pradesh Projects Corporation Limited - UPPCL Tender
Eprocure
Opening Date25 May 2021
Closing Date31 May 2021
Tender AmountRefer Documents
Costs
EMD
₹ 34,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_UPPRC_589438_1Bid Award Id
ViewTender No
11/UPPCL/PM/UNIT-14/2021-22 Date- 21.05.2021Tender Authority
Uttar Pradesh Projects Corporation Limited ViewPurchaser Address
-Website
http://http://upprojects.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Chaki Keet Palan Building in Resham Farm District Lakhimpur Kheri
BOQ Items
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the site of work and including watering ,dressing etc rate to include cost of all materials, labour T&P etc. Required for proper completion of work
18.4
-
669.75
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shallbe as follows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters /100 sqm (5)Treatment of soil along external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apron along external perimter 5 liters/100 sqm.
96.3
-
199.5
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in lintal & plinth bands excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20
4.65
-
10450
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in sunshade excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20
1.23
-
10545
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20
20.28
-
10545
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in lighter beam excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20
2.17
-
11020
Mild Steel or iron in plain work such as reinforced brick work( when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorized overlapping shall be measured
23.85
-
5795
1st Class brick (M-150) work in 6:1 coarse sand & cement of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work.
54.57
-
5035
1st Class brick (M-150) work in 6:1 coarse sand & cement of 1.50 fineness modulus mortar in super-structure including necessary cutting and moulding of bricks required and also including honey comb brick work thickness of wall more than one brick and for extra labour to above items
39.16
-
6203.5
1st Class brick(M-150) work in 4:1 coarse sand & cement of 1.50 fineness modulus mortar in super-structure including necessary cutting and moulding of bricks required and also including honey comb brick work thickness of wall more than one brick and for extra labour to above items
0.82
-
6631
Supply & fixing of flush doors commericial quality conforming to IS 2202 part 1(1983) including fixing of wooden cleats and stoppers and including fixing & adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmently
9.14
-
1349
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work.(fabrication of door frame including cost of hinges)
100.67
-
56.05
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work.(fabrication of grill & stair case railing)
307.92
-
58.9
Mild Steel or iron work of small size and section such as hoding down bolts,hold fast,tie rods,gratings etc.(when not included in an over all rates) wrought to required form,including of supply of steel,bolts nuts and wastage etc and there fixing required for proper completion of the work.(fabrication of Z section) OPENABLE
384.9
-
60.8
Fixing of M.S chaukhats in position. (a) Door chaukhats
4
-
95
(b) Window chaukhats
8
-
66.5
(c ) Ventilator chaukhats
1
-
52.25
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 Coarse sand)
16.55
-
302.81
12mm thick plaster with cement mortar in proportion of 1:6 cement & sand of 1.25 F.M over brick work minium thickness not be less than 10mm including supply of all materials, labour and T & P etc required for proper completion of the work
208.39
-
228
15 mm cement plaster on the rough side of single or half brick wall of mix 1 cement : 6 coarse sand
201.38
-
285
40mm thick 1:2:4 cement concrete floor with cement approved coarse sand and 2 cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and excluding 8cm local sand and brick ballast 4cm guage in the proportion of 1:4:8 and removing any overlapping mortar at the joints of panels if any giving them a uniform finish including supply of all materials labour T & P etc required for proper completion of the work.
127.41
-
399
2 cm thick cement plaster in dado or skirting in 1:2 consisting of one part of cement & 2 parts of approved coarse sand laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials labour & T & p etc required for proper completion of work.
8.14
-
237.5
2.5 cm (1 thick 1:2:4 plain cement concrete floor with cement,approved coarse sand & 2 cm graded approved stone shingle laid in panels finished with 3mm, floating coat of neat cement and marble dust in 5:1 as specified over & excluding base concrete and remving any over lapping mortar at the joints of panels if any & giving them a uniform finish including supply of all materials,labour and T & P etc. required for proper completion of the work.
117.79
-
361
Apply priming coat over new steel and other metal surface after and including preparing the surface throughly cleaning oil grease dirt and other foreign matter and scoured with wire brushes,fine steel/wood scrappers sand preparing and knotting including cost of all materials,labour and T&P etc. required for proper completion of the work.
25.66
-
107.35
Same as above but on new wood surface.
18.28
-
107.35
Finishing walls with water proof cement paint of approved make and quality on new work with two coats to give an ecen shade vincluding supply of all materia,labour & T 7 p etc required for proper completion of the work
208.39
-
79.8
Distemper one coat with oil bound distemper of approved brand manufacture & required shade on decoreted wall surface to give an even shade over and including a priming coat with cement primer of approved brand & manufacture such as beitish,shalimar,asian paints after throughly brushing surface free from mortar droppings and other foreign matter and also including preparing the surface even also sand prepared smooth including coat of all materials As above but every coat after the first coat
348.64
-
114.95
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
25.66
-
403.75
Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm
4
-
361
P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm
8
-
190
Providing & fixing stainless steel door handles with screws and 150mm long.SI marked
8
-
42.75
Supply of glass strips for flooring 35mm depth 5.5 mm thick
117.79
-
9.03
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
557.03
-
79.33
Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 25mm thick cement concrete (1:2:4 mix) flooring base and 20mm thick plaster (1:2) finished with neat cement. (Analysis)
47.76
-
609.63
Sanitary WORK
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter
20
-
289.8
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm
16
-
274.36
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110mm
4
-
231.85
ELECTRICAL WORK
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash.
16
-
579.5
Same as item No.(1) but for fan and light duty exhaust fan.
7
-
637.45
Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc.
7
-
310.65
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
18
-
141.55
Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects.
18
-
193.8
Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
7
-
323
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
7
-
142.5
Erection and testing of ceiling fan and regulator for room height upto 35mts. including supply of 3mm thick G.I. down rod 19mm dia dully painted, complete in all respects.
7
-
133
Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects.
13
-
478.8
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8 to 10 SWG G.I. wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in
1
-
5111
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
3
-
85.5
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
3
-
199.5
Supply and fixing of flush/surface mounting distribution boards complete in all respects. a) 4 Way TPN
1
-
3429.5
Supply and fixing of 6 to 32 Amps. MCB, (10KA) C Curve
1
-
247
Supply and fixing rating, miniature circuit breakers in axisting MCB DB complete in all respects as required. a) 32 Amp. TPN
1
-
1520
S/F of 32 Amp. 415 V TPN metal clad rewireable type switch fuse unit on angle iron bracket complete in all respects
1
-
2014
Supply and fixing of 16 Amp. 240V SPN metal clad rewireable type switch fuse unit on M.D.F.E.G. Board complete in all respects
1
-
642.2
S/F of single light wall bracket on matching M.D.F.E.G..board base etc. complete in all respects.
8
-
1567.5
Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.
8
-
1130.5
Supply & erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-Make: Usha Cat No.SONATA MAX
7
-
1710