Rajya Krishi Utpadan Mandi Parishad Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Rajya Krishi Utpadan Mandi Parishad - RKUMP Tender

Works
Eprocure
Opening Date18 Oct 2019
Closing Date23 Oct 2019
Tender Amount₹ 3,41,09,949 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.

126.83

783809

6180

... More
Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)

518.28

66339

128

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra.

29.18

233148

7990

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in for slabs (Using 1:1.5:3 Mix concrete) excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra.

221.86

1952368

8800

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in for the lighter beams i.e. having spans upto 6 m.excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

94.16

846027

8985

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Raft foundation and footing with approved stone ballast.excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

147.02

1201153

8170

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in in R.C.C. columns in 1:1.5:3 having strength not less than M-20excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

66.94

615848

9200

... More
M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.

211.06

1002535

4750

... More
40 mm thick damp proof course of cement & approved coarse sand 1:2 with & including water proofing materials as ordered by E/I in the proportion as specified by the manufacturers including supply of all material labour, T & P etc, required for proper completion of the work including proper curing and shuttering.

37.72

9030

239.4

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on D.P.C. after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

37.72

3153

83.6

... More
Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick.

332.04

1784715

5375

... More
M-150 class brick work in 1:4 cement and course sand of 1.25 fineness modules mortar in SUPER STRUCTURE including supply of all materials, labour and tools and plants etc .complete in all respect required for proper completion of the work & as per direction of Engineer-in-charge. 1/2 BRICK WALL

37.35

211774

5670

... More
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

728.86

5510181

7560

... More
15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. (Below plinth)

64.66

13319

206

... More
12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 coarse sand

3009.44

526652

175

... More
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand.

1206.48

199069

165

... More
Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required.

667.8

16027

24

... More
Providing and laying vitrified tiles in floor of 600x600 mm sizes (thickness 10 mm) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, including grouting of joints.

578.04

641624

1110

... More
Providing and laying vitrified tiles in floor of 600x600 mm sizes (thickness 10 mm) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, including grouting of joints. (IN SKIRTINGS)

49.51

50995

1030

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.

172.83

537501

3110

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thickGround Floor

110.4

121440

1100

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.(ground floor)

64.23

40233

626.4

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.(first floor)

46.08

28772

624.4

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).

143.55

38758

270

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :32 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

56.6

79240

1400

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:(a) Double leaf (40 MM )

11.97

18314

1530

... More
Alluminium frame for door

78.9

93575

1186

... More
Supply and fixing of anodised /aluminium windows having 2 mm thick aluminium section excluding coating & an average coating of 20 micron fully glazed made of aluminium door tube size 83.5x 44.65 mm as vertical member & 1114.00 x 44.45 mm size tube in bottom and horizontal members door chaukhat should be of aluminium tublar vertical with two openable shutters. The rate will include cost of material fixtures, 5mm glass handles, locks, screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer I/C. (FOR DOORS, WINODW & VENTILATORS)

114.79

519998

4530

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard ection and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section round the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

803.56

298924

372

... More
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces

1895.73

155260

81.9

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).

2885.98

253966

88

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

3489.35

277054

79.4

... More
Brick coba for water proofing treatment providing and laying brick bat coba water proofing treatment with minimum thickness of 75mm at Khurra and minimum top slope of 1 in 80 over the existing cleaned R.C.C. roof slab spread with acrylic polymer cement slurry (mixed with acrylic polymer water proofing compounds) laid over the prepared surface a layer of 120mm thick (minimum-ave.) brick bat coba laid over the mortar layer to get required gradient for adequate drainage. The voids between brick bats are to be kept between 15mm to 12mm wide. These joint are to be filled with acrylic cement, finished with 12mm thick acrylic cement mortar 1:4 (1 cement: 4 coarse sand) including giving guarantee of 12 years. Written guarantee on stamp paper testing etc. all complete as per specification, drawing and instructions of engineer-in-charge.(SI NO chapter 11 , 6 new )

1492.45

1405141

941.5

... More
Construction of drain alongwith apron.

106.43

94084

884

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

17.64

4787

271.4

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.

3.79

4548

1200

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.

685.27

294529

429.8

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restswith 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required

2

6359

3179.7

... More
Providing and fixing water closet s European type W.C. pan with white plastic seat and lid.Make- Cera,Hindware. 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required

4

12444

3111

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.

5

8269

1653.8

... More
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fitting and brackets, cutting and making good the wall wherever required :Size 450x300x150mm

1

2177

2177.2

... More
Providing and fixing stainless steel A ISI 304(18/8)kitchen sink as per IS 13983 with C.I. brackets, stainles steel plug 40mm including painting the fitting and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board of size 510x1040x200mm

2

6865

3432.8

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32mm dia

5

344

68.8

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 40mm dia

3

222

74

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

5

3721

744.3

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic One urinal basin with 5 litre white P.V.C. automatic flushing cisternwith standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required

2

6359

3179.7

... More
Providing and fixingGranite Stone of approved shade stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.

0.5

1288

2577

... More
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore

4

927

231.9

... More
Providing and fixing C.P brass shower rose with 15 or 20 mm inlet100 mm diameter

2

130

65

... More
Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge.a) 15mm dia nominal dia.

2

8582

4291.3

... More
Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.

4

1538

384.6

... More
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms

7

875

125

... More
Providing and fixing Toilet paper holder) C.P. brass

4

1402

350.7

... More
Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete.

2

1043

521.7

... More
Providing & fixing soil, waste and vent pipes.a) 100mm dia centrifugally cast iron S & S pipe.

75

62902

838.7

... More
Providing & fixing soil, waste and vent pipes.b) 75mm dia centrifugally cast iron S & S pipe.

110

79530

723

... More
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.a) 100mm

57

16074

282

... More
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.b) 75mm

84

20151

239.9

... More
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.a) for 100mm dia pipe.

46

7005

152.3

... More
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.b) for 75mm dia pipe.

68

10213

150.2

... More
Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors.a) 100mm inlet & 75mm outlet.

17

16595

976.2

... More
Providing & fixing cast iron coller.a) 100mm dia.

39

12464

319.6

... More
Providing & fixing cast iron coller.b) 75mm dia.

57

11365

199.4

... More
Providing and fixing plain cast iron S & S sanitary bend.a) 100mm

6

1828

304.8

... More
Providing and fixing plain cast iron S & S sanitary bend.b) 75mm

8

1806

225.8

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.a) 100mm

6

2101

350.2

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.b) 75mm

8

2313

289.2

... More
Providing and fixing centrifugaly cast iron single equal plain junction of required degree.a) 100x100x100mm

4

2094

523.6

... More
Providing and fixing centrifugaly cast iron single equal plain junction of required degree.b) 75x75x75mm

10

3685

368.5

... More
Providing and fixing cast iron terminal guard.a) 100mm

3

911

303.7

... More
Providing and fixing cast iron terminal guard.b) 75mm

4

966

241.7

... More
Providing & fixing 32 MM G.I. Pipes complete with G.I Fittings & clamps i/c cutting & making good the walls etc.

12

3367

280.6

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter

104

22360

215

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.a) 110mm

7

1194

170.7

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm

28

4620

165

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

7

260

37.2

... More
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.a) 20mm dia nominal bore (medium duty)

90

18360

204

... More
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.b) 25mm dia nominal bore (medium duty)

45

10147

225.5

... More
Providing & fixing 32 MM G.I. Pipes complete with G.I Fittings & clamps i/c cutting & making good the walls etc.

42.5

11925

280.6

... More
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.a) 15mm dia nominal bore

135

35100

260

... More
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.b) 20mm dia nominal bore

75

21577

287.7

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.a) 15mm dia nominal bore.

135

729

5.4

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.b) 20mm dia nominal bore.

165

1056

6.4

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.c) 25mm dia nominal bore.

45

373

8.3

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.d) 32mm dia nominal bore.

35

346

9.9

... More
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore

5

308

61.7

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore

6

2029

338.2

... More
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15mm nominal bore

4

1792

448.2

... More
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15mm nominal bore

11

4761

432.9

... More
Providing and fixing gun metal gate valve with wheel of approved quality.a) 20 mm dia nominal bore

6

2164

360.8

... More
Providing and fixing gun metal gate valve with wheel of approved quality.b) 25mm dia nominal bore

4

1558

389.6

... More
Providing and fixing gun metal gate valve with wheel of approved quality.c) 32mm dia nominal bore

2

911

455.6

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)a) 20 mm dia nominal bore

6

933

155.5

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)b) 25mm dia nominal bore

4

749

187.3

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)c) 32mm dia nominal bore

2

374

187.2

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats completea) 25 mm nominal bore

7

2114

302

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.a) Circular Tank

5000

30000

6

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.a) Pipes 80mm to 300mm diameter.

95

19484

205.1

... More
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 100mm diameter

25

4920

196.8

... More
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.b) 150mm diameter

70

20832

297.6

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.a) 100mm diameter S.W. Pipe

25

14172

566.9

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.b) 150mm diameter S.W. Pipe

70

48531

693.3

... More
Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 150 x 100 mm. size P typeWith Sewer bricks conforming to IS : 4885

5

7463

1492.7

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75(i) For Sewer Line

6

47142

7857

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75(i) For Sewer LineExtra for depth of man hole size 90x80 cm

1.5

7805

5203.9

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard designWith 20x20 mm square bar

22

5363

243.8

... More
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

4

1193

298.4

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250mm diameter

1

355

355.9

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)a) 50mm nominal bore.

35

10913

311.8

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)b) 32mm nominal bore.

20

4502

225.1

... More
Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.a) 50mm nominal bore.

35

2387

68.2

... More
Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.b) 32mm nominal bore.

20

1296

64.8

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.a) 50mm

1

614

614.9

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.b) 32mm

1

455

455.6

... More
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, with C.I. surface box 100x100x75mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks

2

2175

1087.7

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm dia nominal bore

1

358

358.6

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm dia nominal bore

1

701

701.8

... More
Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m to 3.0m. depth

21.49

3474

161.7

... More
Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20 mm nominal size)

1.34

6684

4988.57

... More
M-150 class brick work in 1:4 cement and coarse sand sand of 1.25 fineness modules mortor in foundation and plinth including supply of all materials, labour and tools and plants etc .complete in all respect required for proper completion of the work & as per direction of Engineer-in-charge. (S

93.62

458738

4900

... More
Reinforcement for R.C.C. work including, straightening, cutting bending binding and placing in position complete.

95.6

7227

75.6

... More
15mm cement plaster on rough side of mix 1:4 cement & coarse sand of 2.25 F.M.

57.79

11020

190.7

... More
Providing and fixing C.I. tee at the inlet and outlet of septic tank.

2

1092

546

... More
Providing & fixing 75mm dia vent pipes.

1

648

648.1

... More
Providing & fixing of 75mm dia cast iron terminal guard.

1

179

179.3

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter

2

1653

826.6

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.L.D. -2.5- Circular shape 450mm internal diameter

4

3283

820.9

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks

1

18820

18820.2

... More
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

27.6

2155

78.1

... More
Mild steel or iron work of door / windows grill.. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

72

5623

78.1

... More
Mild steel or iron work of Z-Section steel windows (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

72

5623

78.1

... More
Mild steel or iron work ofAngle iron chaukhat 35*35*5 (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.

54.75

4275

78.1

... More
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J & N , Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.

387.11

30581

79

... More
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.

4

738

184.7

... More
Providing & fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm

4

662

165.5

... More
Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete(a) 250 mm x 10mm

4

308

77

... More
Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete(a) 200 mm x 10mm

4

266

66.6

... More
Providing & fixing aluminium handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete

8

315

39.4

... More
Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.

174.18

16634

95.5

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete.With 4.0 mm thick glass panes.

3.6

2170

602.9

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratoriesportions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it water tighte) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

44.5

93832

2108.6

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

44.5

145256

3264.2

... More
Providing & fixing S.W Gully trap of self cleansing design with C.P. JALI complete, including cost of cutting & making good the walls & floors.a) 150X100 mm

5

1150

230

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.a) 110mm diameter

5

575

115

... More
Extra for providing & fixing PVC ball float valve with brass & union 20MM DIA

2

460

230

... More
P/F in position PVC PIPE jointing Solution

5

1925

385

... More
P/F Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stablity for hot and cold water supply including all CPVC plain and brass threaded fittings . . This includes jointing of pippes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Eng. I/C. Exposed on walla) 25mm dia nominal bore (medium duty)

15

3300

220

... More
P/F Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stablity for hot and cold water supply including all CPVC plain and brass threaded fittings . . This includes jointing of pippes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Eng. I/C. Exposed on wallb) 32mm dia nominal bore (medium duty)

15

3600

240

... More
P/F Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stablity for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 mt. spacing . This includes jointing of pippes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Eng. I/C. CONCEALED work including cutting ,chases and making good the wall etc.a)20mm dia nominal bore

35

8925

255

... More
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore

7

490

70

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore

5

2175

435

... More
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15mm nominal bore

5

2400

480

... More
Providing & fixing C.P. brass stop cock (concealed)of standard design and of aprroved ,make confirming to IS 8931 a) 15mm nominal bore

5

2375

475

... More
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15mm nominal bore

5

2500

500

... More
Providing and fixing gun metal gate valve with C.I wheel of approved quality.a) 25mm dia nominal bore

5

1925

385

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.a) Pipes 80mm to 300mm diameter.

40

6800

170

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.a) 100mm diameter S.W. Pipe

25

10625

425

... More
Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 100 x 150 mm. size P type

2

2580

1290

... More
Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.a) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.

2

14600

7300

... More
M.S or iron work of small sizes & section such as holding down bolts ,M.S GRILL,wrought to be required from including supply of steel bolts ,nuts,wastage etc.

5535

480438

86.8

... More
Providing and fixing plain PVC sanitary bend.a) 100 mm

40

2400

60

... More
Finishing wall with water proof cement paint such two coat over a priming coat of water proof cement paint of approved quality such as super "Snowcem, Durocem" superior quality of required shade on undecorated wall surface over white cement one coat to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material including curing and cost of materials labour & T&P etc. required for proper completion of work.(S.I.No. . 660+661)

13949.48

641676

46

... More
Finshing wall with water proofing cement paint of approved make such as supper snowcem durocem, robiacem, guttucem suppercem quality and of required shade on undercoated wall surface (Two coat) over and including one coat white cement primer ( Birla White cement) to give an even shade after throughly brushing the surface to powdered materials including curing and cost of all materials. (SI NO 660+661)

6963.33

598846

86

... More
Painting two coat over old painted surface on steel and other metal surfaces upto 12 cm. width or girth or small articles not exceeding 0.12 sqm in area white superior synthetic enamel such as Luxol 3. Higloss apcolite superlac Dulux specified brushing to give an even shade and including cleaning the surface of all dirt dust and other foreign material sand papering and stopping including cost of all materials labour. Tools and plants etc. required for proper completion of the work. (NBO 19.40+19.29+19.73b)

6849.97

496622

72.5

... More
Dismantiling of cc work or cement mortar and including stacking of materials as directed by E/I. with in a distance of 60 M. (S.I. No, 694)

1959.67

88185

45

... More
40 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of size 12.5 mm and below) laid over base concrete and finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (Excluding cost of glass strips) (SI. No. 605)

2420.96

980488

405

... More
Dismantling of plaster ,Racking out joints and including stacking of materials as directed by E/I with in a distance of 60 M. (S.I.No.706)

7040.52

225296

32

... More
12 mm. thick plaster with cement and coarse sand(1.25 FM) mortar in proportion of 1:6 over brick work. including supply of all materials, labour T&P etc. required for proper completion of the work and also including racking and washing joint as per direction of E/I. (N.B.O. 17.58(ii)

4104.55

677250

165

... More
06 mm. thick plaster ceiling with cement and coarse sand mortar in proportion of 1:3 over R.C.C. or brick work. including supply of all materials, labour T&P etc. required for proper completion of the work and also including racking and washing joint as per direction of E/I

1418.62

159594

112.5

... More
Supply and fixing rolling shutter of approved make made of 80x1.25 mm (3"x18 gauge) cold rolled MS lath interlocked throughout their entire length and joined together at the end by end locks and material on specially designed pipe shaft with bracket side guides and arrangement for inside and cut side licking with push and pull operation complete but excluding of cost top cover and springs. (S.I. 520)

207.27

228183

1100.9

... More
Providing and fixing top cover for rolling shutters. (S.I. 522)

92.8

51661

556.7

... More
Providing and fixing ball bearing for rolling shutter. (S.I. 523)

150

44415

296.1

... More
Oiling greesing of rolling shutter complete work required for proper completion of work as a direction of Engineer in charge.

109

16350

150

... More
Scraping old white or colour wash including disposal of refuse as directed by Engineer in charge with a distance of 60 M.

24264.3

242643

10

... More
Supply and fixing of glass strips 35 mm wide and 05 mm. thick including supply of all material labour T&P etc. required for proper completion of work (.631b)

2327.64

41897

18

... More
Earth work in excavation in trenches for foundation and pipe, cab;e etc in ordinary soil (Loan clay or sand) including lift upto 1.5 M. lead upto 50 M. and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by Engineer in charge within a lead of 50 Meter.251

380.07

45608

120

... More
Concrete with 4 cm gauge over burnt brick ballast fine sand and cement in proportion of 1:6:12 in foundation and under floors including supply of all materials, labour tools and plants etc. required for proper completion of the work.273

127.35

436810

3430

... More
Laying C.C slab in A.P.F. floor 10 cm thick consisting 1:2:4 cement, coarse sand and approved 2 cm. gauge graded stone grit, over prepared sub-grade after its rectifications and bringing it to proper camber including supply of all materials, labour and T&P etc required for proper completion of work as directed by Engineer-in-charge but including coat of metal required for rectification of the sub-grade.279 b

89.17

660303

7405

... More
Making construction Joint with 6 mm A.C. sheet strips including supply of all materials labour and T.& P etc.complete. required for proper completion of work.

10.8

270

25

... More
Mild steel or iron work in heavy size for RSJ ISMB 100x200. wrought to required form including drilling holes riveting or welding where necessary and their fixing required for proper completion of the work. (S.I.No. 503)

6.09

52861

8680

... More
Mild steel or iron work in heavy size such as trusses build up gates record racks roof work gates etc. wrought to required form including drilling holes riveting or welding where necessary and their fixing required for proper completion of the work. (S.I.No. 503)

16.2

140616

8680

... More
Supply and fixing of everest prime steel roof er-32/251 color coated galvalume sheet .5mmTCT,high strength 550MPA yeldstress minimum . (D.S.R. 2016/12.50)

9701

4850500

500

... More
Supply and fixing of everest prime steel roof er-32/251 color coated galvalume sheet .5mmTCT,high strength 550MPA yeldstress minimum .e but with ridges. (SI.BNo. 542)

497.4

163147

328

... More
10 mm dia Bolts for fixing of angle iron @ 30 cm c/c

1.1

8316

7560

... More
Finishing walls two coat of water proof cement paint sadtax matt of approved quality on previously old treated surface with this paint to give an even shadeand including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even with plaster of paris or approved synthetic material and sand papered smooth including cost of all materials.-. (SI NO CPHT 14, 67.1)

581.41

44768

77

... More
Dismantling of slab ( RB ) and including stacking of materials as directed by E/I with in a distance of 60 M. (S.I.No.696)

38.79

11637

300

... More
Dismantling of door and windows including chaukhats directed by E/I with in a distance of 60 M. (S.I.No.697)

57.6

3168

55

... More
Supply and fixing of 10 cm dia internal P.V.C. down pipes complete with rose heads, bends, M.S. clamps 2.5x3mm fixed to walls by 15 cm long 6 mm dia nail sand including repair of plaster pointing etc. if damaged during fixing of the pipes including cost of fail material labours tools and plant etc. required for proper completion of work.

70

15470

221

... More
20 mm cement plaster in two coats backing coat 17 mm and finishing coat 3 mm thick of neat cement and marble dust in ratio 5:1 in dado and skirting on brick wall for interior plastering upto floor two level including arises internal rounded angles chambers and rounded angles not exceeding 80 mm in grith and finished even and smooth as per direction of E/I. (1 cement 3 coarse sand) (PWD 597)

33.45

8028

240

... More
Making drip course or FACIA in sun shade or slab

86.74

780

9

... More
Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge.

77.18

30872

400

... More
M-150 class brick work in 1:4 cement and course sand of 1.25 fineness modules mortar in one brick wall in super structure including supply of all materials, labour and tools and plants etc .complete in all respect required for proper completion of the work & as per direction of Engineer-in-charge.

81.02

447635

5525

... More
Supply and fixing 150mm dia hexagonal box type fan hook with 12mm dia round bar complete with all materials labour and T&P etc. required for proper completion of work. (SI NO 281)

10

1000

100

... More
R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in for the lighter beams i.e. having spans upto 6 m.excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire.

36.4

309582

8505

... More
Boring providing & installing cast-in-situ single under reamed pile of specified dia and length below pile cap in cement concrete with mix 1:1.5:3 of 20mm nominal size to carry a safe working load not less than specified excluding the cost of steel reinforcement but including boring with pentonide solution and length of pile to embedded in the pile cap. (DSR-20.3.1-4% VAT) (a) 300mm dia single bulb Piles

35

65523

1872.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.