Northern Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Northern Railway - NR Tender

Works
Ireps
Opening Date22 Jan 2025
Closing Date12 Feb 2025
Tender Amount₹ 86,66,383.72 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required of following sizes:-

-

-

45917.85

... More
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.

-

-

5

... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 06 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.

250

551

137857.5

... More
Supply, fixing, testing & commissioning of LED light luminaries 595 X 595 mm size, 07 Tile type, having system wattage 36-45 Watt , CRCA body powder coated , high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement accessories conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.

90

4625

416333.7

... More
Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input 08 power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable )

90

2594

233497.8

... More
Supply, erection, fixing, testing & commissioning of Fresh air Fan size 12'' 220 V.AC.,50 Hz, ISI marked, to be approved by SrDEE/G/MB complete in all respect as per tech. specification / site requirement.

20

1976

39529.6

... More
Supply, fixing, testing & commissioning of wall mounting fan 400 mm (16") sweep 220 V.AC.,50 Hz, with inbuilt speed regulator ISI marked (Bracket fan) to be approved by SrDEE/G/MB as per tech. specification complete in all respect.

50

4015

200777.5

... More
Supply, erection, testing & commissioning of air circulating high speed bracket fan 11 230 V, 50 Hz, AC, 600 mm sweep, ISI marked complete and fixing by suitable MS nuts and bolts on wall/pillar with necessary masonary works for fixing of air circulator i.e. cement, concrete, coarse sand etc. as required at site and as per direction or Railway Engineer.

20

9152

183059.4

... More
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.

10

13111

131114.2

... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 13 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification. 14

15

4349

65242.35

... More
Supply,installation,testing & commissioning of Maintenance Free Earthing.

10

19442

194420.5

... More
Design, Fabrication, Supply, Fixing and commissioning of Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 15 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.

5

4126

20634.55

... More
Supply, installation, testing & commissioning of complete 60 watt LED Street light 16 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.

20

4561

91237.4

... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. 17 Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductorcable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.

-

-

328730

... More
Supply and laying of GI pipe 'B'class ISI marked under road /track/ clamping with erected pole or wall as per technical; specifications and drawing for passing cable of following sizes:100 mm.dia

50

770

38511.5

... More
Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep 19 as per relevant IS suitable for laying HDPE Pipe of 140 mm inner dia and 160 mm outer dia. & shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-1995 (latest version) included).

550

971

534187.5

... More
Supply, installation and commissioning of MCCB 4 pole 250 amps. current breaking 20 (35-37) kA, MCCB should be direct manual operation type with thermal magnetic quick and break impedance. MCCB shall be suitable for operation on 3-phase AC, 415 volt, 50 Hz, overall specification conforming to IS 13947-Part-2-1996/IEC-60947 or latest complete in all respect as per tech. specification and site requirement.

4

10388

41553.32

... More
"Design, manufacture, supply, erection, fixing, testing & commissioning of LT Panel as per IS 8623 (Latest Version) with 01 no. incoming ACB 800 Amps (draw out type) and outgoing 250 Amps MCCB four pole 35 KA - 03 nos., 125 Amps MCCB four pole 35 KA- 04 nos., 63 Amps MCCB four pole 35 KA- 05 nos. and 1x400 Amps COS on load (Back to Back Type) complete in all respect and as per site requirement. The cubicle shall be made of 16 SWG Galvanized Steel sheet screwed/welded on 50x50x6 mm angle iron frame to be fixed on ground / wall. It shall be covered from all sides with 21 MS sheet with opening doors & locking arrangements and powder coated. The Panel has 800 Amps. Copper Bus Bar for phase and neutral. The incoming feeder provided with three phase MF meter ( rating 0 - to 100 KW ), Amp. Meter ( 0 to 200 Amps.) , Volt Meter ( 0 to 500 V.) along with VSS, ASS. The Incoming feeder equipped with incoming supply, Indication lamps. The work also includes removal of existing panel, detachment of cable from existing panel and masonry work along with formation of platform for erection of new panel. The Incoming / Outgoing cable in new panel to be terminated with suitable size cable gland and terminating lugs and conforming to relevant IS and as per site requirement."

1

616500

616500.37

... More
Design & manufacure LT switch board as per IS 8623/IEC 60439, Supply, Installation, fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system.The LT.Switch Board shall be powder coated. The 22 switch board shall be complete with inter connections, instrument connections with copper conductor cable, copper busbar & front operated switchgears, Volt meter on each Incoming Panel, Ampear meter Digital with Selector switch on each I/C & O/G panels, Indication lights ( lamp set.) earthing studs etc.comprising of following ie.MCCB 200 Amps-1 No., 100 Amps-02 Nos.,COS 100 Amps-01 No. complete in all respect.:- ( 3 ways- 1 No. I/C & 2 Nos. O/G.)

1

61695

61695.13

... More
Earthing with 600x600x3 mm thick copper plate earth electrode as per IS : 3043 ( 23 latest version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. copper strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.

2

5379

10759.78

... More
Connections with 40x6 mm. copper strips in 50 mm dia GI pipe class' B' 300 mm. deep in ground / recessing in floor from earth electrode strip to neutral of transformer / alternator as per drawing and technical specification including supply of material complete in all respect.

20

443

8873.8

... More
Earthing with 600x600x3 mm thick GI plate earth electrode as per IS : 3043 ( latest 25 version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. GI strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.

4

3378

13513.64

... More
Connections with GI strips in 300 mm deep in ground / recessing in floor clamping in 26 trenches of sub-station by grouting clamps manufacture with MS sheet 14 SWG from Earth electrode strip to HT Panel/LT Panel/AMF Panel /Transformer/ DG Set etc. as per approved drawing and technical specification including supply of material size ( 2 Nos. 40 x 5 mm. or 40 x 10 mm ).

40

152

6080.8

... More
Supply , erection ,testing & commissioning of 16 meter high mast tower system with following work (a) Supply installation, testing and commissioning of 16 meter high mast system totally hot dip galvanized, inside out side in single dip, suitable for wind velocity 50 meter / sec as per IS 875 part-3. The mast shaft shall be in two sections with one longitudinal seam weld per section and no circumferential weld which can be jointed by slip stress method. The system in including head frame, steel wire rope 6 mm dia (7/19 construction) double drum winch, galvanized lantern carriage arrangement suitable for 8 lumiaries symmetrically and its GC box lighting finals. The mast shall have integral type high power reverseable power tool for electrical operation of raising and lowering of lantern carriage mounted in the base compartment of high mast with arrangement to couple with the 27 winch and torque limiter -1 No. b) Supply and erection of foundation bolt manufactured from special steel with nuts, washers, anchor plates and templates-1set. c) Supply design and casting of suitable shallow foundation with M-20 for the high mast considering the safe soil bearing capacity at site as 10 T / sq meter at 2 meter depth- 1 No. d) Supply erection testing commissioning of twin dome aviation light having twin type construction with 2 No light of LED type. - 1 Set. e) Supply installation testing commissioning of heavy gauge hot dipped galvanized lighting finals-1 No. f) Supply installation testing and commissioning of feeder panel comprising of main in coming switch of MCB's, time switch, contactor, reversing starter and protective system etc as required for operation of high mast system - 1 No. g) Supply erection testing and commissioning of copper plate earthing with 600X600X3 mm copper earth plate, pipe and electrode as per drawing and confirming to specification at annexure & IS 3043 including connection to the mast with GI strip of size 40X6 mm- 2 No. ( 1 for finial & 1 for mast).

2

276703

553407.94

... More
Fabrication, supply and erection of Fencing around the high mast in square shape size 28 2MX2M and height 1.5 M from ground level fabricated from MS angle size 40x40x6 mm, MS flat size 40x6 mm AND WIRE MESH MADE OF 8 SWG wire and 1M wide hinged type lockable door as per drawing approved by Railway including grouting, CC platform around the high mast above 0.30 M above ground level and painting etc. and as per technical specification.

2

7400

14800

... More
Supply, erection, testing and commissioning of of 1x120 W LED type flood light fitting, Confirming to PCEE/NR's spec. No. CEE/NR/121Elect/PS/2018 (Rev- '3') dated 28.06.2018 or latest & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') dated 04.11.2019 or latest.

24

9938

238523.52

... More
Supply, erection, fixing, testing & commissioning of Modular AC box with 32 Amps plug socket and 32 Amps. DP MCB (10 KA) complete in all respect & as per site requirement.

12

1866

22396.56

... More
Supply, installation, testing & Commissioning of light weight wall mounted type Voltage Stabilizer confirming to IS : 8448 suitable with toroidal care transformer having capacity 4 31 KVA, input voltage 135 - 290 Volt and output voltage 220 - 240 Volt, MCB 32 Amps, time delay relay ( 2 - 4 min ) with soft touch type instant and start switch, under voltage and over voltage cut off with indicators. Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON.

12

2527

30333.72

... More
Installation, fixing, testing and commissioning of 1 to 2 ton capacity Split type AC 32 including suction / discharge copper tubing charges & ducting arrangement for waste water discharge complete in all respect & as per site requirement. (Air conditioners will be supplied by Railways).

12

1890

22681.08

... More
Supply, erection, testing & commissioning of ISI marked Stationary storage Vertical 33 vented type electric water heater conforming to IS: 2082/1993 with latest amendments , material of inner container copper Capacity 25 Ltrs., 1500 watt, pressure 60N/SQM, Class-I complete with element, thermostat etc and suitable for operation on 240 volts single phase AC50 Hz supply BEE 5 Star rating complete in all respect as per site requirement.

1

6953

6953.67

... More
SITC OF 2 KVA 24 VOLT SINE WAVE INVERTER OPERATING ON 230 VOLT 50 Hz AC ALONG WITH 12 VOLT 180 AH LEAD ACID TUBULAR BATTERY (2 NOS) WITH BOX STAND.

2

41361

82723.8

... More
"Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. 01 including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. "

450

38

17149.5

... More
Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable 02 conforming to IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/Main as required as per technical specification including connections, testing and commissioning of following sizes:

-

-

31519

... More
Supply, fixing, testing commissioning of MS switch boxes of the following size made 03 out of 16 SWG MS sheet duly painted / coated with red oxide primer with egg white hylem sheet 3 mm. thick as per tech. specification, ISS / IE Rules and site requirement. Hylem sheet shall be larger than MS Boxes of following sizes:- ( NOTE :- The MS Boxes shall be with earthing bolts and hylem sheet shall be fixed with 04 Nos. brass machine screws and washers etc.)

-

-

2576.2

... More
Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per 04 IS:4794(Part-2)-1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per technical specifications.

-

-

4350

... More
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.

50

18

913.5

... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 06 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.

50

551

27571.5

... More
Supply, erection, fixing, testing & commissioning of 1200 mm sweep Energy efficient Ceiling fan with fan regulator etc. complete in all respect as per CEE/NR spec no. CEE/NR/123- Elect/PS/2018, dt.15.10.2018 (Attached) or latest & as per site requirement.

10

2339

23390.1

... More
Supply, erection, fixing, testing & commissioning of Fresh air Fan size 12'' 220 V.AC.,50 Hz, ISI marked, to be approved by SrDEE/G/MB complete in all respect as per tech. specification / site requirement.

5

1976

9882.4

... More
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.

1

13111

13111.42

... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 10 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification.

4

4349

17397.96

... More
Design, Fabrication, Supply, Fixing and commissioning of Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 11 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.

4

4126

16507.64

... More
Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule. 13

5

3061

15308.3

... More
Supply,installation,testing & commissioning of Maintenance Free Earthing.

2

19442

38884.1

... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 14 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.

-

-

54726.5

... More
"Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. 01 including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. "

1000

38

38110

... More
Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable 02 conforming to IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/Main as required as per technical specification including connections, testing and commissioning of following sizes:

-

-

98345

... More
Supply, fixing, testing commissioning of MS switch boxes of the following size made 03 out of 16 SWG MS sheet duly painted / coated with red oxide primer with egg white hylem sheet 3 mm. thick as per tech. specification, ISS / IE Rules and site requirement. Hylem sheet shall be larger than MS Boxes of following sizes:- ( NOTE :- The MS Boxes shall be with earthing bolts and hylem sheet shall be fixed with 04 Nos. brass machine screws and washers etc.)

-

-

3382.3

... More
Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per 04 IS:4794(Part-2)-1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per technical specifications.

-

-

6470.56

... More
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.

120

18

2192.4

... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 06 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.

47

551

25917.21

... More
Supply, erection, fixing, testing & commissioning of 1200 mm sweep Energy efficient Ceiling fan with fan regulator etc. complete in all respect as per CEE/NR spec no. CEE/NR/123- Elect/PS/2018, dt.15.10.2018 (Attached) or latest & as per site requirement.

15

2339

35085.15

... More
Supply, fixing, testing & commissioning of wall mounting fan 400 mm (16") sweep 220 V.AC.,50 Hz, with inbuilt speed regulator ISI marked (Bracket fan) to be approved by SrDEE/G/MB as per tech. specification complete in all respect.

8

4015

32124.4

... More
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.

2

13111

26222.84

... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 10 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification. 11

4

4349

17397.96

... More
Supply,installation,testing & commissioning of Maintenance Free Earthing.

9

19442

174978.45

... More
Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of 12 masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule.

8

3061

24493.28

... More
Design, Fabrication, Supply, Fixing and commissioning of Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 13 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.

5

4126

20634.55

... More
Supply, installation, testing & commissioning of complete 60 watt LED Street light 14 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.

35

4561

159665.45

... More
Supply and fixing of 5 meter long Hot dip galvanized octagonal pole with foundation, 15 base plate, fixing of 01/02 nos. arm 1000 mm. for the fittings including smart pack junction box with 06 Amps. MCB DP (10 KA) and terminals as per technical specification & complete in all respect/as per site requirement.

12

12426

149118

... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 16 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.

-

-

183076.7

... More
Supply, installation, testing and commissioning of welding points complete with 63 17 amp MCCB 4 pole 35 KA with 15 Amp + 5 Amp switch socket as per IS:4979-1968(latest version) Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection and fixing as per site requirement.

8

9053

72431.2

... More
Supply, installation and commissioning of MCCB 4 pole 250 amps. current breaking 18 (35-37) kA, MCCB should be direct manual operation type with thermal magnetic quick and break impedance. MCCB shall be suitable for operation on 3-phase AC, 415 volt, 50 Hz, overall specification conforming to IS 13947-Part-2-1996/IEC-60947 or latest complete in all respect as per tech. specification and site requirement.

2

10388

20776.66

... More
Design & manufacure LT switch board as per IS 8623/IEC 60439, Supply, Installation,fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system.The LT.Switch Board shall be powder coated. The switch board shall be complete with inter connections, instrument connections with copper conductor cable, copper busbar & front operated switchgears, Volt meter on each Incoming Panel, Ampear meter Digital with Selector switch on each I/C & O/G panels, Indication lights ( lamp set.) earthing studs etc.comprising of following ie.MCCB 200 Amps-1 No., 100 Amps-02 Nos.,COS 100 Amps-01 No. complete in all respect.:- ( 3 ways- 1 No. I/C & 2 Nos. O/G.)

1

61695

61695.13

... More
Earthing with 600x600x3 mm thick GI plate earth electrode as per IS : 3043 ( latest 20 version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. GI strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.

4

3378

13513.64

... More
Connections with GI strips in 300 mm deep in ground / recessing in floor clamping in 21 trenches of sub-station by grouting clamps manufacture with MS sheet 14 SWG from Earth electrode strip to HT Panel/LT Panel/AMF Panel /Transformer/ DG Set etc. as per approved drawing and technical specification including supply of material size ( 2 Nos. 40 x 5 mm. or 40 x 10 mm ).

38

152

5776.76

... More
Earthing with 600x600x3 mm thick copper plate earth electrode as per IS : 3043 ( 22 latest version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. copper strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.

4

5379

21519.56

... More
Connections with 40x6 mm. copper strips in 50 mm dia GI pipe class' B' 300 mm. deep in ground / recessing in floor from earth electrode strip to neutral of transformer / alternator as per drawing and technical specification including supply of material complete in all respect.

38

443

16860.22

... More
"Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. 1 including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. "

4000

38

152440

... More
Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable 2 conforming to IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/Main as required as per technical specification including connections, testing and commissioning of following sizes:

-

-

279770

... More
Supply, fixing, testing commissioning of MS switch boxes of the following size made 3 out of 16 SWG MS sheet duly painted / coated with red oxide primer with egg white hylem sheet 3 mm. thick as per tech. specification, ISS / IE Rules and site requirement. Hylem sheet shall be larger than MS Boxes of following sizes:- ( NOTE :- The MS Boxes shall be with earthing bolts and hylem sheet shall be fixed with 04 Nos. brass machine screws and washers etc.)

-

-

3650.2

... More
Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per 4 IS:4794(Part-2)-1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per technical specifications.

-

-

6601.6

... More
Supply & Installation of modular type switches /sockets/Fan Regulator etc. ISI marked as per relevant IS on the existing moular plate & switch boxes including connections testing & commissioning as per technical specifications of the following sizes:-

-

-

65465.4

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required of following sizes:-

-

-

37537.15

... More
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.

100

18

1827

... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 8 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest. .

100

551

55143

... More
Supply, erection, fixing, testing & commissioning of 1200 mm sweep Energy efficient Ceiling fan with fan regulator etc. complete in all respect as per CEE/NR spec no. CEE/NR/123- Elect/PS/2018, dt.15.10.2018 (Attached) or latest & as per site requirement.

100

2339

233901

... More
Supply, erection, fixing, testing & commissioning of Fresh air Fan size 12'' 220 V.AC.,50 Hz, ISI marked, to be approved by SrDEE/G/MB complete in all respect as per tech. specification / site requirement.

20

1976

39529.6

... More
Supply, fixing, testing & commissioning of wall mounting fan 400 mm (16") sweep 220 V.AC.,50 Hz, with inbuilt speed regulator ISI marked (Bracket fan) to be approved by SrDEE/G/MB as per tech. specification complete in all respect.

20

4015

80311

... More
Supply, installation and commissioning of MCCB 4 pole 250 amps. current breaking 12 (35-37) kA, MCCB should be direct manual operation type with thermal magnetic quick and break impedance. MCCB shall be suitable for operation on 3-phase AC, 415 volt, 50 Hz, overall specification conforming to IS 13947-Part-2-1996/IEC-60947 or latest complete in all respect as per tech. specification and site requirement.

2

10388

20776.66

... More
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.

4

13111

52445.68

... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 14 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification.

8

4349

34795.92

... More
Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of 15 masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule.

4

3061

12246.64

... More
Design, Fabrication, Supply, Fixing and commissioning of Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 16 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.

4

4126

16507.64

... More
Supply, installation, testing & commissioning of complete 60 watt LED Street light 17 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.

20

4561

91237.4

... More
Supply and fixing of 5 meter long Hot dip galvanized octagonal pole with foundation, 18 base plate, fixing of 01/02 nos. arm 1000 mm. for the fittings including smart pack junction box with 06 Amps. MCB DP (10 KA) and terminals as per technical specification & complete in all respect/as per site requirement.

10

12426

124265

... More
Supply, Installation, Testing and Commissioning of 10 watt LED Garden Light (SMD LED Chip) operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification no. CEE/NR/121Elect/PS/2018(REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest including protection of the entire housing as per IS:10322(Part 1):1982 latest-IP66, Luminaires casing/housing shall beTop Spun Aluminium /Die cast Aluminium and 19 Bottom Die CastAluminium with higherthermal conductivity, Mounting Fixture size- 150mmx100mmx600mm, Suitable connector shall be provided for LEDconnection between driver output and LED, extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust, water, insects etc., corrosion resistant powder coated, Thickness and Ik rating Diffuser-3mm, IK-08, Mounting Pipe size-70 mm, Length of ISI marked three core wire shall be provided along with supply of material50 cm complete in all respect and as per site requirement.

20

2429

48587.6

... More
Design, Fabrication, Supply, fixing, testing & commissioning of Meter cum distribution box ( size - 0.5 m. x 0.3 m. x 0.135 m.) along with 16/32 Amps DP MCB 01 No. (10 KA) & SP MCB 20 6/16 Amps. 4 Nos. (10 KA) complete with Bus Bar & fixing of Single phase KWH meter 10/20 Amps. Wall mounted dust & vermin proof, fabricated with 16 SWG MS sheet, powder coated including door with hinges, locking arrangement, nut & bolts, cement sand interconnection etc. and painting with two coats of enamel gray paint over a coat of red oxide primer for anti dust & as per site requirement complete in all respect as per IS specification. (only KWH meter to be supplied by Rly.)

4

2643

10572.32

... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 21 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.

-

-

210524

... More
Supply and laying of GI pipe 'B'class ISI marked under road /track/ clamping with erected pole or wall as per technical; specifications and drawing for passing cable of following sizes:100 mm.dia

50

770

38511.5

... More
Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep 23 as per relevant IS suitable for laying HDPE Pipe of 140 mm inner dia and 160 mm outer dia. & shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-1995 (latest version) included).

50

971

48562.5

... More
Supply, erection, testing & commissioning of ISI marked Stationary storage Vertical 24 vented type electric water heater conforming to IS: 2082/1993 with latest amendments , material of inner container copper Capacity 25 Ltrs., 1500 watt, pressure 60N/SQM, Class-I complete with element, thermostat etc and suitable for operation on 240 volts single phase AC50 Hz supply BEE 5 Star rating complete in all respect as per site requirement.

10

6953

69536.7

... More
Earthing with 600x600x3 mm thick GI plate earth electrode as per IS : 3043 ( latest 25 version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. GI strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.

4

3378

13513.64

... More
Connections with GI strips in 300 mm deep in ground / recessing in floor clamping in 26 trenches of sub-station by grouting clamps manufacture with MS sheet 14 SWG from Earth electrode strip to HT Panel/LT Panel/AMF Panel /Transformer/ DG Set etc. as per approved drawing and technical specification including supply of material size ( 2 Nos. 40 x 5 mm. or 40 x 10 mm ).

40

152

6080.8

... More
Design, supply, erection, testing and commissioning of 11.5 Mtrs. lighting system complete with power driven double drum with mechanism for lowering/Railing of fittings lantern 27 carriage, lightning arrester , earthing, automatic lighting control switch with COB LED light luminaires, power tool including foundation as per specification by manufacturer etc. as per I.E. Rule and relevant I.S., tech. specification/Site requirement as specified as under:- i)High Mast Tower suitable for 08 COB LED light luminaries, hot dip galvanized and suitable for wind velocity as per I.S.-875-Part- 3 including head frame, steel wire rope 6mm dia, double drum winch, galvanized lantern carriage arrangement, lighting arrestor, safety wire cable with termination box foundation bolts winch assembly. ii)Power Tool. iii)Foundation. iv)Control Panel with accessories. v)08 no. 120 watt LED Flood light fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121- Elect/PS/2018(Rev-3), dt. 28.06.2018 (Attached) or latest. . Note:-Warranty/Guaranty shall be claimed from the tenderer and not from OEM for light luminaries. The tenderer should replace the material at his own cost by liasioning with OEM. Security will be released after completion of Guaranty period of five years.

1

304826

304826.58

... More
"Design, manufacturing, supply, erection, testing and commissioning of Astronomical Timer Switch along with TPN 63 Amps. And associated accessories as per detail below:- (a)Astronomical Digital timer switch with provision of Automatic calculation of sunrise and sunset time for any day throughout the year, the time switch should have inbuilt offset provision of +/- 120 Mins for both sunrise and sunset and should have 06 years running reserve battery backup along 28 with single channel output voltage 220V, single phase and contact rating 16 Amps. (b) Modular 63 Amps with 4 NO Power Contactor suitable for DIN Rail mounting with integral lable holder, provision for manual override for test and repair function, output voltage 415V, 3 Phase, coil voltage 24V AC. (c)TPN,MCB 63Amps. 10 KA with integral label holder and bottom clamp. MCB shall have copy tracer number with laser marking. Termination capacity of MCB shall be 35 Sq. mm. on both side. (d)Accessories like internal wiring (between MCB, timer and contactor with 2.5 sq.mm. wire and 6.0 sq.mm. wire for 25A contactor and 16.0 sq.mm. wire for 63 A contactor and timer ) locks, hinges, gaskets, nuts & bolts etc. (e)MS fabrication box 12W SPN double door IP 43 distribution board. "

1

20463

20463.87



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.