Northern Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Northern Railway - NR Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date9 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 4,30,64,776.35 
Notes
Download

Costs

Summary

S&t Work Of Addition & Alteration In Existing Electronic Interlocking System (medha Make) Of Distributed Architecture At Malhaur & Barabanki Stations Along With Outdoor S&t Work At Both The Stations In The Barabanki-malhaur Section In Connection With 3rd-4th Line Work Between Barabanki-malhaur Section Of Lucknow Division Of Northern Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. 5 Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection: Consignee or site incharge for supply portion.

3

21240

63721.98

... More
Fabrication, supply and fixing of scaffolding /cable carrier made of angle iron of Size 6 35mmX35mmX5mm and flat of size 25mmX3mm as per instructions of engineer at site. The space between two flats will be 25cm or less as per site requirements all the fixing materials i.e. nut, bolt washer, insulators, cement concrete etc. will be supplied by the contractor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint.

120

511

61334.4

... More
Supply of Flexible , PVC sheathed, PVC insulated Copper wire 16/.20 sq.mm. (wiring materials) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest. (From RDSO Approved Source only). Inspection: Consignee.

3

8963

26890.59

... More
Wiring of relays in relay room/relay huts as per appd wiring diagrams. All wiring 8 material including resistances and condensers etc. except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching, lacing and fixing of relay bases.

70

467

32690.7

... More
Supply of electric fuse complete with fuse block(base) for Railway signalling non- 9 deteriorating type low voltage fuse assembly 2Amp/4Amp/16Amp. to suit . Specn. No.IRS: S-78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev.2 & Amd.2) and drg no. 23748 (IRS), Alt-4 or latest. Fuse block shall be suitable for round head type fuses. Inspection: RDSO.

120

197

23689.2

... More
Supply fixing and wiring of Fuse Auto Changeover System (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 10 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor. Inspection: RDSO for supply portion.

4

40935

163741.48

... More
Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 11 sq.mm-2.5 sq.mm center marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carrier rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: RITES

13000

117

1524900

... More
Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: RITES.

280

150

42224

... More
Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: RITES.

2800

18

52612

... More
Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: RITES.

2800

16

46200

... More
Fabrication & supply of domino type operating cum indication panel for way side station/LC Gate as per RDSO spec RDSO/SPN/186/2004, Ver. 2 or latest (if applicable). This includes LEDs, acrylic sheet etc. Inspection: Consignee. 16

-

-

15

... More
Installation and complete wiring of optg-cum indication panel for mid section LC Gate.

96

60

5760.96

... More
Supply, installation, testing, networking & commissioning of Remote Terminal Unit with 17 64 digital and 16 Analog inputs as per RDSO Spec IRS-S-99/2006, Amd.3 with latest amendments complete along with accessories with contractors own wiring & fixing material. The requisite communication Cable/Channel for networking will be arranged by Railway. Inspection: Consignee.

1

232763

232763.93

... More
Supply of power wires 1x6sq.mm. (Red & black), IS 694/2010 or latest. Inspection: Consignee.

1

62719

62719.61

... More
Supply of power wires 1x16sq.mm. (Red & black), IS 694/2010 or latest. Inspection: Consignee.

1

171234

171234.92

... More
Supply of power wires 1x25sq.mm. (Red & black), IS 694/2010 or latest. Inspection: Consignee.

1

274485

274485.02

... More
Supply of 3 phase Manual changeover switch 63Amps/100Amps. Siemens/ Havells or similar Iron Clad switch. Inspection: Consignee.

2

6071

12143.46

... More
Preparation of cable route plan, Cable core chart, Power supply arrangement plan for indoor and out door , Cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit history card, Fuse analysis plan , Equipment 22 disposition plan, Track circuit jumpering plan, Terminal and Contact analysis chart , Outdoor circuits,pull sheets,gomettie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the Engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings. (iv) Design through CAD. (v) Drawings in A3 & plans in bigger size. (six sets).

2

48011

96023.14

... More
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 23 earth as per drg. No.NR/S&T/CON./1.1/97A so as not to form a drain 0.3 mtrs. wide & 1 mtr. deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of roots of trees & bushes.

43000

80

3445590

... More
Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer.

344000

8

2917120

... More
Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11. The marker shall be fixed at various places of cable route as per instruction of Eng. at site.

900

1462

1316115

... More
All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe-(ISI marked) conforming to RDSO Spec no. 26 RDSO/SPN/204/2011 or latest, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 mtr. from rail flange/road level. Inspection: RITES for supply portion.

1800

2116

3810528

... More
HDD Boring & Trenchless of 120mm dia without HDPE pipe for laying of signalling / telecom /power cable under track/road/culvert etc. cable laying is covered separately.

500

953

476520

... More
Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97C and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables.

80000

9

728800

... More
Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately after termination of cable. This also includes dressing & lacing of cable on both ends. Performa for testing & material for lacing to be supplied by the contractor.

-

-

29

... More
Casting, concreting and curing of foundation and erection of apparatus case single as 30 per Drg. No.NR/S&T/Con./2.7/97. A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination.

40

6344

253780.4

... More
Supply of single apparatus case steel RE with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/219/82 & 221/82 with Alt.B. Inspection: RITES.

40

24001

960070.8

... More
Preparation of App. Case single involving wiring of relays: Preparation & fixing of Bakelite hylum sheet 910x800x6mm and Bakelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, 32 pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). Relays, ARA terminals only shall be supplied by the Railways.

14

6569

91975.8

... More
Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the 33 hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways.

20

5398

107973.4

... More
Preparation of App. Case to be used as battery box (not requiring shelf and hylum of size 910x150x6mm only is reqd.): This includes fixing of fuses, ARA terminal and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank 34 and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways.

6

3246

19477.08

... More
Casting, concreting and curing of foundation and erection of half apparatus cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2.8/97. A layer of 3 mm of 35 bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination.

60

5572

334361.4

... More
Supply of apparatus case steel RE half with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/220/82 & 221/82 with Alt.B. Inspection: RITES.

-

-

36

... More
Preparation of App. Case half not involving wiring of relays: Preparation & fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the 37 hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways.

60

3704

222271.2

... More
Supply of terminal block 25mm center M-6 (ARA terminals) as per IRS spec. No.IRS-S- 75/2006 (Rev.2) & IRS drawing No. SA-23741A(Alt.4), SA-23745(Alt.5), SA-23746 & SA-23756(Alt.3). Inspection: RDSO.

13000

75

982280

... More
Casting, concreting and curing of foundation for main signal of size (1,041mm X 39 1,041mm) at bottom and (711mm X 711mm) at top and 1,750mm deep as per Drg. no. NR/S&T/CON./2.1/97 all material such as anchor bolts, cement, sand aggregate to be supplied by contractor.

36

11782

424172.88

... More
Supply of colour light signal post 4.6m and ladder 4.5M with bases as per IRS specification No. IRS-S-6-81, Rev-3 or latest. Inspection: RITES.

36

20617

742244.4

... More
Supply of 2 Aspect colour light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest, spec. IRS-S-26/64, Rev.1 or latest. Inspection: Consignee.

6

17441

104648.76

... More
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS 42 unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (Retro reflective) with complete fittings as per standard railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc. for the following: (a) Installation, erection, wiring of 2 aspect color light signal.

6

3088

18532.26

... More
Supply of 3/4 Aspect colour light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23002 A/M (Adv), Alt.-9 or latest,SA-23001 A/M (Adv), Alt.-9 or latest respectively, spec. IRS-S-26/64 or latest. Inspection: RITES.

30

22267

668029.5

... More
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS 44 unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (Retro reflective) with complete fittings as per standard railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc. for the following: (a) Installation, erection, wiring of 3/4 aspect color light signal.

22

4574

100631.08

... More
Supply of 1-way route indicator junction type complete with hoods & offset bracket 5 1/2" without holders, lamps, lenses and signal transformer as per RDSO specn.no.IRS-S-66/84 Amd. 1 or latest, drg.no. SA 23401(Adv), Alt.-2 or latest. Inspection: Consignee.

2

26543

53086.34

... More
Supply of 2-way route indicator junction type complete with hoods & offset bracket 5 1/2" without holders, lamps, lenses and signal transformer as per RDSO specn.no.IRS-S-66/84, Amd.1 or latest drg.no. SA 23402(Adv), Alt.-2 or latest. Inspection:

6

31060

186365.16

... More
Supply,fixing & wiring of Multi Lamp Route Indicator (LED Single Digit) from 1 to 9 & G route with metal housing as per specification: 1. Single digit LED route indicator capable of displaying 1 to 9 & route 'G'. 2. Visibility of 300 mtr. in clear day light. 3.Option for white color, chromaticity as 47 per BS:1376 standard. 4. Built with robust AlInGaP (Aluminium-Indium-Gallium-Phosphide), InGaN (Indium-Gallium-Nitrate) LED's with junction temperature >100. 5. Lamp proving compatible with AC LED ECR. 6. Input operating voltage: 110V AC +/- 20%. 7. Uniform intensity over entire operating range. 8.Operating temperature -10 to @43<46@ 9. Operating current: 105mA to 168mA. Inspection: Consignee.

4

77386

309547.52

... More
Installation, erection and wirng of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator which also includes fixing of route 48 indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focussing of signal & route indicators. All items for installation and erection (excluding unit junction type route indicator and offset bracket covered separately) to be supplied by the contractor. Wiring & other fixing material, 'U' bolts will also be supplied by the contractor.

8

4435

35484.08

... More
Fabrication, Supply and fixing of retroreflective P/G/C markers with complete fittings as 49 per approved Drg. No. NR/S&T/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts, paint and painting materials will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) & SA 23477(Adv) respectively.

26

807

21001.76

... More
Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 50 1000mm deep and erection of retroreflective SLB/BSLB/SB/calling on boards/Goods Warning Board/Passanger Warning Board as per drg. No. NR/S&T/CON/7.4/97 & provisions of SEM. It includes supply of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board. The SLB/BSLB shall be as per approved Drg. No.SA-2373 or latest.

6

9979

59879.16

... More
Supply of calling-on colour light signal unit with offset bracket 3.5" dia. Type as per drg.no.SA 24351-52(Adv) or latest and spec.no.IRS-S-23/88. or latest. Inspection: Consignee.

4

4727

18909.6

... More
Installation, erection & wiring of LED lit C/ON signal /dependent shunt signal /illuminated 'A' marker/ 'AG' marker/ 'F' markers on the same post below the main signal on offset 52 bracket. The wiring material to be supplied by contractor. It includes fixing of LED signal unit and hoods, wiring and focusing of the signal. Supply of offset bracket, calling-on signal/Shunt signal complete is covered as separate item of schedule. 'U' bolt for offset bracket wire and wiring material will be supplied by contractor.

4

1037

4150.8

... More
Supply of shunt signal position light complete with unit post and surface base as per drg.no SA 23840(adv) to SA 23848 (adv) & specs.no.IRS-S-23/88 (Independent post type). Inspection: Consignee.

8

9526

76209.6

... More
Casting, concreting and curing of foundation of Shunt signal/ 'F' marker of size 855mm 54 x 855mm at bottom and 711mm x 711mm at top and 750mm deep as per Drg No.NR/S&T/Con /2.1/97A. All material such as Anchor bolts, cement, sand, sand stone aggregate to be supplied by the contractor.

8

4006

32055.44

... More
Installation, erection & wiring of independent position light shunt signal/F marker, this includes fixing of shunt signal, surface base signal post, LED unit, hood and all wiring & fixing material such as U' bolt, nuts, washer, wire, wire mesh etc. will be supplied by contractor.

8

1262

10102.96

... More
Fixing, wiring , Testing , adjustment of Point Machine as per standard practice. Its also includes: i) Fixing of switch extension 'P' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, erection & wiring of JB with lock & key as per 56 drawing, provided with terminal strips (if required). iii) Supply & fixing of GI pipes with flange for taking cable in to point machine and jn. Box through gland/GI pipe. iv) Complete material for installation viz. point insulation material, Jn. box, GI pipe, gland pipe, wiring material, nut & bolts of various sizes, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation materials for stretcher bar 90R/52kg/60kg as per . drg.no.SA-23171 (adv.) Alt.1 will be supplied by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/S&T/CON/7-6/97 and william stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of ground connections of electric point machine, non insulated GTP & CTP extension plate, Jn. box and stretcher bar shall be made available by the Rlys. in which the supply of ground connections, Jn box is covered separately. 57

6

9277

55667.16

... More
Supply and fixing of spigot for point machines (Job = Per Pt. Machine).

6

248

1491.78

... More
Supply, installation and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank 58 handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor. Inspection: RDSO for supply portion.

6

19165

114992.58

... More
Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be 59 done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per drg. No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This includes supply of all material by contractor as per RDSO specifications (as applicable) except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provisions of Paras under IRS spec. S-36/87, Amd.2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. Inspection: RDSO for choke & Consignee for Register.

12

15056

180682.56

... More
Supply of QTA2 relays AC immunized plug in type DC 9 Ohm neutral track relay miniature tractive armature with 2F/1B contacts as per BRS : 939A or latest amendments, BRS:966- Append.F2, IRS-S@45"44@ IRS-S-23 & IRS:S-60 (as applicable). Inspection: RDSO.

14

5605

78471.26

... More
Supply of Track Feed Charger 110AC/2-4-6 VDC/10Amp. As per RDSO Spec. No.89/2013 (Amd.1) or latest from RDSO approved firm. Inspection: RDSO.

14

4513

63189.84

... More
Supply of sec. cell low maintenance 2 V/ 80 AH conforming to IRS S-88/2004, Rev.1 or latest with micro porous vent plugs cum floats with inter cell connectors, nuts, bolts, washers etc. Inspection: RDSO.

40

3102

124096.8

... More
Charging of 80AH secondary batteries (with contractor's charging equipment) as per standard procedure. All the charging materials i.e. sulphuric acid confirming to latest IRS 63 specifications and distilled water confirming to latest specifications will be supplied by the contractor. This also includes installation of secondary batteries, their inter-connections & writing work as per directions of site Engineer.

40

239

9578

... More
Installation, testing & commissioning of High Availability Single Section Digital Axle Counter System complete by OEM or its authorized dealer. The axle counter will be High Availability Single Section type with two detection points and it is possible to install it without trolly protection track circuit. The axle counter must consist of following. The wire and other wiring material will be 64 arranged by contractor at site. (a) Mounting of high frequency TX and RX coil-2 sets, each set consist of web mounting type 2 no. of TX and 2 No. of RX. TX & RX shall be supplied by Rly. (b) Mounting of track side digital axle counter Unit-2 no. (c) Fixing of vital relays etc. duly wired-2 Nos. (d) Clamping with deflector plate and hard ware for mounting of two set of TX & RX coil. (e) Resetting arrangement of each axle counter. (f) All the wiring material required for installation and commissioning shall be arranged by contractor. (g) This also includes integration with existing SGE/Token-less/Token block instruments were required as per instructions of site engineer.

2

84882

169765.4

... More
Installation, testing & commissioning of complete system i.e. block equipment UFSBI, multiplexer, wiring in relay room, panel room for single/double line operation system as per technical specification. This item needs to be carried out by OEM or under supervision of OEM.

2

72499

144998.08

... More
Supply, Installation, testing and commissioning of Electrically Operated lifting barrier assembly as per RDSO Spec. No. RDSO/SPN/208/2012 (version 2.0) or latest consisting of 2 nos. of electrically operated lifting barriers, 2 pedestals, 8 band circuit controller with limit switches of Siemens, hand cranks, 2 electric motors, 110V AC, without centrifugal switch, 2 GI Boom in 4 sections of 8 feet each with 2 retroreflective stop boards, boom light boxes, MS counter weight, 2 nos. of boom 66 support for resting boom etc. The item also consists of following items: a) Supply of motorized boom locking /unlocking assembly with electrical coil complete (1 no. each). b) Supply of level crossing gate control panel floor mounting type with swithches and buttons sheet metal fabricated, (1 No). c) Supply of push button for operating the gate with 2 NO/NC contact, green colour-close & Amber-open, Siemens or Kaypee or similar make (1 no.) Inspection:RDSO for supply portion. d) Supply of solid state electronic flasher 24V DC operated (1 no. each). e) Supply of dual tone warning bell with 20W horn & 15W amplifier (2 no. each). Inspection for (d) & (e): Consignee.

1

610495

610495.11

... More
Design and preparation of wiring diagram for Level-Xing MACLS on the basis of approved interlocking plan, typical circuit diagram and as per Railway practice and latest rules prescribed by the Railway and obtaining approval of the competent authority. Preparation of locking 67 tables and dog charts to suit colour light signalling plan and obtaining the approval of the competent authority. Drawing shall be supplied as per following:- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software backup of complete set in the form of CDs.(iii) The complete set of tracings.(iv) Design through CAD.(v) Drawing in A3 & plans in bigger size (6 sets).

1

41563

41563.32

... More
Cleaning, scraping, painting and lettering of all newly installed and existing gears by 68 the contractor for existing/ new Level Crossing Gates. This includes supply of all painting materials and marking of all the circuit particulars near terminal on terminal board/in apparatus case/Jn. boxes and fuse no., relay and equipment's nomenclatures as per approved terminal chart and provisions of SEM.

1

18257

18257.76

... More
Supply of Electronic Timer relay, 24 V DC @40<47@120 sec) as per RDSO Spec. IRS:S:61/2000 (Amend. No. 3) or latest. Inspection: RDSO.

2

3314

6628.82

... More
Supply, Installation & Commissioning of Emergency Sliding Boom complete with all accessories for L/B gate. Inspection: Consignee for supply portion.

1

279201

279201.11

... More
Supply of spare electric operated lifting barrier GI booms as per latest RDSO Drg S- 11600 in maximum 4 sections of 8 feet each. Inspection: Consignee.

1

39173

39173.51

... More
Installation, wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bar and relay racks in the room with contractor's own wiring materials including all types of wires/cables etc and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic laminated sheets or any standard make with connections suitable for 72 32 Amp. as per site requirement. Wiring to be done with flexible cable, single core multi strand 6 sq. mm as per spec-IRS-76/89 with latest amendment from AC distribution board to Integrated Power Supply system. Wiring to be done with Flexible Cable, Single core, multi strand 10sq mm. as per spec IRS 76/89 with latest amendment from integrated power supply system to D.C. bus bar. All connections as per site requirement to be arranged by contractor as per RDSO guidelines and instruction of railway engineer at site. This item includes supply and fixing of ladder along the wall for carrying of power supply wires/cables from IPS room to relay room/ power room / Battery room etc.

1

62456

62456.52

... More
Supply of Transformer 3KVA 230V/130/110V as per IRS Spec No.S-72-88, Amd.2 with latest amendment. Inspection: Consignee.

-

-

73

... More
Supply of OFC integrated acess device 1U height or 1.5 U height / 19 " rack mountable for LVCD / Digital axle counter purpose ; optical module integrated in the unit supporting dual core OFC and one 100Mbps Ethernet port for survilance / smoke detector ; optical distance support to be 74 20 kms; unit to support one E & M module supporting four 2W / 4W ( each port configurable ) to support axle counter / UFSBI / Control phone / EC / RTU / and one TELNET / SNMP port ; unit to support DC / AC power supply ; unit to support change over mechanism between quad and optical fiber for E & M option ; one number cable to be provided along with unit for E & M ; FABIO / 2CX / OFC / DC & Module 2W / 4W four port : Make : TEAM ENGG / FABIO / WAVES or similar / TANSY. Unit Set = 02 Numbers. Inspection: RITES. 75

2

257290

514581.56

... More
Installation & commissioning of OFC equipment for SCADA/axle counter per location.

3

24910

74731.62

... More
Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 or latest with latest amendments. Earthing kit consist of: 1. Earthing electrode of 17mm dia and 3 meter long- 01 no. 2. MEEB (300mmX25mmX6MM) -01 no. 3. SEEB (150mmX25mmX6mm)-01 no. 4. Earth enhancing compound-30 Kg (minimum). This include provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, IPS, data logger, MSDAC, SSDAC etc. with PVC earth wire 76 of size 16/25Sq.mm through copper lugs of suitable size. PVC wire shall be supplied by Railways. Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For inter-connection of two earth pits copper tape of size 25x2 sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection: Consignee for supply portion.

14

26445

370243.3

... More
Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted 77 connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earhting connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. ( NR/S&T/CON/6.3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: RITES for supply portion.

150

3617

542577

... More
Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts, GI pipe pullies, pully stakes wire run from cabin 78 to signal posts etc. All dismantled material to be transported and stack in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Store/TKJ or any other store of N.Rly as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Signal).

8

1421

11369.6

... More
Dismantling and releasing of Point equipments which includes all S&T fittings of electrical and mechanical, facing point lock/ hand plunger lock/ lock bar / holding bar/ EPD/ 79 mechanical detecter/ Pt. machine with all attachments. All dismantled material to be transported and stack in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Store/TKJ or any other store of N.Rly as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Point)

6

1550

9301.68

... More
Dismantling and releasing of location boxes which includes all S&T fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteriies, track feed chargers and 80 other associated fittings installed therein complete with fittings. All dismantled material to be transported and stack in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Store/TKJ or any other store of Northern Railway as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Location box).

40

811

32475.2

... More
Loading, Leading & unloading of released materials from site to the Dy.CMM/Alambagh store at Lucknow Division by contractor.

3000

6

18750

... More
Dismantling of Foundation of RCC/MCC cement concrete anywhere in Yard/Block section up to required level for all heights.

-

-

82

... More
Earth work for excavation and refilling around location boxes and signals etc. where 83 necessary including 50M lead and 1.5M lift. The lead is to be measured from center of gravity of location to the center of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, leveling and dressing etc. as per instruction of Engineer at site.

30

144

4340.7

... More
Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand 84 ratio. It also includes the excavation of earth as required at site and as per instruction of site in charge. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor.

5

3397

16986.45

... More
Cleaning, scrapping, painting & lettering of all newly installed & existing gears such as signals, point equipment, track circuit equipment with TC No. on rail, apparatus cases, JB, TLJB, point Roding, cranks, compensators etc. including gate equipment if existing in station section as per the 85 provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engineer and painting materials to be supplied by the contractor. This includes writing, and painting requirement of all indoor and outdoor gears along with marking of all circuit Nos. near terminal and terminal boards/rack in apparatus cases, Jn .boxes, relay room, SMs room, writing of relay nomenclature, fuse Nos. and equipment nomenclature as per the approved plans and as per provision of IRSEM. (1 JOB = 1 Station).

2

24482

48965.7

... More
Supply & provison of straight through joints thermo shrink jointing kit with the help of 86 thermo shrink jointing kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 Quad/04 Quad cable. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection: Consignee for supply portion.

18

7699

138588.66

... More
Supply of thermo shrink jointing kit as per IRS TC 77/2012 Rev.3 with Amdt 1 & 2 latest 87 amendments & provision of derivation isolation joint in quad cable & PIJF cable at LC gate, pump, houses, station cabins etc. using thermo shrink jointing kit as per specifications, drawings and stipulations of tender documents. This includes all material required for making joints. Inspection: Consignee for supply portion.

30

8624

258730.8

... More
Supply and Provision of Emergency socket joints within 6 quad cable and PIJF cable 88 with the help of Thermo shrink jointing kit and 2T VF Transformer at locations decided by engineer at site. This includes all material required for jointing including Thermo shrink jointing kit will be supplied by contractor except 2T VF Transformer (2T VF Transformer will be supplied by the Railway) as per IRS: RDSO/SPN/TC/56/2015 (Rev.1) with latest amendments. Inspection: Consignee for supply portion.

34

4880

165943.46

... More
Supply of VF Tapping & Termination Transformers 2T/1120:470 Ohm as per IRS-TC- 22/76 with Amd 1 with latest amendments.(round shape) Inspection: Consignee.

34

2360

80252.58

... More
Switch board cables per IRS Specification No IRS-TC-24/91 Make delton. (a) 5 pair/0.6 mm. Inspection: Consignee.

4000

55

221720

... More
Switch board cables per IRS Specification No IRS-TC-24/91 Make delton. (b) 10 Pair/0.6mm. Inspection: Consignee.

8000

104

836240

... More
Supply of "Emergency socket Box of FRP material" as per RDSO specification no. RDSO / SPN / TC / 44/ 02 Ver.2.0, Amendment No.3 or latest. Inspection: Cosnignee.

34

1574

53528.92

... More
Fixing of Emergency socket box made of FRP materials as per Spec. 94 No.RDSO/SPN/TC/44/2002 Ver.2 (with latest amendment) at locations to be indicated by the engineer. Emergency socket & Emergency socket box will be procured through separate schedule of this contract and issued to the contractor for execution. All other items shall be supplied by the contractor.

34

1013

34444.72

... More
Supply of cable fault locator for underground cable as per model no.Telscout TS-90 (Test signal output1/2 Sine, Pulse width 5nsec to 2500nsec, Max Range:1500m, Filter cut-off Frequency:150kHz(High Pass Filter), Gain:0 to 63dB), Stanlay or similar branded make as per 95 specification. Inspection: Consignee.

1

332229

332229.26

... More
Supply of electronic Cable Route Locator/Tracer equipment of C-scope/ Stanlay make 96 or similar. (i) Cable avoidance tool DXL2 digital under ground cable & pipe locating receiver and cable avoidance tool. (ii) SGV2 signal generator. (iii) Signal lamp accessory ST-SC. (iv) Carry bag ST-CB and as per technical specification. Inspection: Consignee.

1

323347

323347.61

... More
Supply of Digital insulation Tester (Megger) 100 V, Motwani, Philips or equal to make. Inspection: Consignee.

2

6623

13247.72

... More
Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply 98 pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site Engineer. It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 Rev.2.0). Inspection: RITES for supply portion. 99

38

74082

2815139.56

... More
End plug for item no.98 above. Inspection: Consignee. 100

80

33

2681.6

... More
Cable sealing plug for item no.98 above. Inspection: Consignee. 101

80

42

3389.6

... More
Plastic Coupler-Slip Fit/Push fit type for item no.98 above. Inspection: Consignee. 102

80

86

6914.4

... More
Blowing/Drawing of OFC cable in the HDPE duct by mechanical system.

38

11635

442142.92

... More
Supply and installation of optical fibre cable joint enclosure as per TEC spec no. 103 GR/OJC-02/01/ March 99 with latest amendment and splicing of optical fiber cables (24 fibers & testing). This includes provision of jointing kit (RCC/Prefabricated) as detailed in the technical specification and as adviced by engineer at site. Inspection: Consignee for supply portion.

25

19019

475495

... More
Supply of OFC jumper (Patch card) 10mtr. long with FC/PC & SC or suitable connector at both end as per IRS:TC-81/2000 with latest amendment. Inspection: Consignee.

10

657

6579

... More
Supply of OFC jumper (Pigtail) 10mtr. long with FC/PC & SC or suitable connector at both end as per IRS:TC-81/2000 with latest amendment. Inspection: Consignee.

10

492

4923.3

... More
Hiring and operating multi utility vehicle (Maximum 3 vehicle in a month) of loading capacity one MT with sitting capacity of 4 to 6 persons, 4-stroke, 4-cylinder engine, factory built metal 106 body, cargo box type passenger cabin type or both (with 24 hrs availability) including cost of fuel, lubricants, operating and maintenance including on kutcha/pucca road along the track. The contractor shall arrange road permit for vehicles for all the states of operation as per instructions of engineer incharge. Vehicle shall not be older than 3 years. The max KM utilization per month is 1200KM per vehicle.

10

30234

302348.9



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.