Northern Railway Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Northern Railway - NR Tender
Electrical and Electronics
Electrical Works
Ireps
Opening Date22 Jan 2025
Closing Date12 Feb 2025
Tender Amount₹ 22,99,428.39
Costs
EMD
₹ 46,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Work For Heavy Repair Due To Electrical Assets/wiring To Prevent Damages In The Officer Rest House Under Aden/hw &
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
02_SrDEE_G_MB_2025-MORADABAD DIVISION-ELECTRICAL/NORTHERN RLYTender No
02_SrDEE_G_MB_2025Tender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 4 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.
10
527
5279.8
... More
"Supply Installation Testing & commissioning of Decorative LED Wall Light, Flower 5 design, 5 Watt, Input voltage range: (110-240 volts AC), 50Hz complete with accessories, LED conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') or latest attached ."
25
1184
29607.5
... More
"Supply Installation Testing & commissioning of Decorative LED Mirror Light Fitting 10- 6 12 watt to be fitted in mounting.the fitting should have decorative and attractive look.LED should be confirming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at attached or latest."
4
662
2649.28
... More
"Supply, fixing, testing and commissioning of 4M LED FOOT LIGHT of 2-5 Watt, White.LED conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') or latest attached ."
20
533
10673.6
... More
Supply, fixing, testing & commissioning of LED light luminaries 595 X 595 mm size, 8 Tile type, having system wattage 36-45 Watt , CRCA body powder coated , high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement accessories conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.
20
4625
92518.6
... More
Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input 9 power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable )
10
2594
25944.2
... More
Supply, erection, fixing, testing & commissioning of Fresh air Fan size 12'' 220 V.AC.,50 Hz, ISI marked, to be approved by SrDEE/G/MB complete in all respect as per tech. specification / site requirement.
5
1892
9461.25
... More
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.
2
12962
25924.6
... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 12 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification.
4
4349
17397.96
... More
Earthing with 40mm dia GI Pipe class 'B', 3 meter along earth electrode as per IS 3043 13 (Latest version) to achieve earth resistances less than 5 ohms including construction of masonary enclosures with hinged cover plate of cast iron/RCC (Heavy duty with lifting arrangement) with locking.
6
3061
18369.96
... More
Supply, installation, testing & commissioning of complete 60 watt LED Street light 14 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.
10
4414
44149.2
... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 15 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.
-
-
10555
... More
"Design & manufacture LT switch board as per IS 8623(Latest version), Supply, Installation, fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system. The LT Switch Board shall be powder 16 coated. The switch board shall be complete with inter connections, instrument connections withcopper conductor cable, copper bus bar & front operated switchgears, Voltmeter, Ampere meter Digital with Selector switch I/C with Indication lights ( lamp set.) earthing studs etc. comprising of following I/C-MCCB 200 Amps (35 KA) 4 pole-1 No., O/G-100 Amps MCCB (35 KA)4 Pole-02 Nos., 63 Amp MCCB (35 KA)4 Pole- 02 Nos, 32 Amp MCB (TPN) (35 KA)- 4 Nos. complete in all respect and conforming to relevant IS and as per site requirement."
1
126252
126252.44
... More
Supply, erection, fixing, testing & commissioning of Modular AC box with 32 Amps plug socket and 32 Amps. DP MCB (10 KA) complete in all respect & as per site requirement.
6
1866
11198.28
... More
Supply, installation, testing & Commissioning of light weight wall mounted type Voltage Stabilizer confirming to IS : 8448 suitable with toroidal care transformer having capacity 4 18 KVA, input voltage 135 - 290 Volt and output voltage 220 - 240 Volt, MCB 32 Amps, time delay relay ( 2 - 4 min ) with soft touch type instant and start switch, under voltage and over voltage cut off with indicators. Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON.
6
2527
15166.86
... More
Installation, fixing, testing and commissioning of 1 to 2 ton capacity Split type AC 19 including suction / discharge copper tubing charges & ducting arrangement for waste water discharge complete in all respect & as per site requirement. (Air conditioners will be supplied by Railways).
6
1890
11340.54
... More
Supply, erection, testing & commissioning of ISI marked Stationary storage Vertical 20 vented type electric water heater conforming to IS: 2082/1993 with latest amendments , material of inner container copper Capacity 25 Ltrs., 1500 watt, pressure 60N/SQM, Class-I complete with element, thermostat etc and suitable for operation on 240 volts single phase AC50 Hz supply BEE 5 Star rating complete in all respect as per site requirement.
2
6953
13907.34
... More
SITC OF 2 KVA 24 VOLT SINE WAVE INVERTER OPERATING ON 230 VOLT 50 Hz AC ALONG WITH 12 VOLT 180 AH LEAD ACID TUBULAR BATTERY (2 NOS) WITH BOX STAND.
2
41361
82723.8
... More
Supply and fixing of RCCB 2P 25A 30mA with metal enclosure. RCCB and metal enclosure should be of same make and of reputed manufacturer and as per specification.
2
2394
4788.1
... More
"SITC of sign panel side-single side illuminated ,""1 mm aluminium sheet with laser cut graphics ,painted to required colour , fixed to aluminium extrusion type SOLIS SB-01 made out of aluminium alloy 6063.0(HE9WP) as per IS63400 or latest with max tensile strenght 130 MPa and BHN of 25 made from virgin aluminium using Hot casting technique to produce close grained and oxide free product,JINDAL,HINDALCO,BALCO or similar ,pasted to structure using Acrylic VHB tape -3M ,4941 or Avery Dennision AFB 8680 or similar.Letter fascia to be laser cut out from opel perplex sheet of 4 mm thickness with LT % value of 70 ,certified as such by an accredited Lab,fixed in graphite space from inside make - LUCITE,MITSUBISHI,PERPEX,ARKEMA or similar. Illumination provided by 23 LED modules fron inside 6500K certified by accredited Lab ,Beam characteristics : 155 c colour consistency (Mac Ad au 5) integrated current source to stablize luminous flux .Ambient temp.25c to 50c . Max surface temp. 65c protection rating IP 68. Luminous flux per module 70 lm. CRI>80. Lum efficiency 97 lm/w voltage = 072 w/ 60 mA per module .En 62031 ,LED to be NICHEA/Samsung or similar ,DC current with LUM maintenance of 89.7% over hours with supporting certificate. To use as per sign Size :- 20 w, 40 w, 60 w, 100 w, 150 w, constant current mode power supply , Universal AC input/Full range ,Fully encapsulated with IP 67 range, Withstand 300 V AC surge input for 5 seconds ,100 % full load burn in test , 5 years guarantee ,Class C as per EN61000-3-2 ,suitable for central battery system ,Auto shut and restart in case of overload, Auto power modulation & restart outside range bound temperature ,Hiccup mode and auto recovery in case of short circuit on secondary side (LED) make TALEX,MEANWELL,ST MICRO electronics PHILIPS or similar.Sizes as per site requirement."
25
2676
66902.5
... More
"Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. 1 including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. "
2000
38
76220
... More
"Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable 2 conforming to IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/Main as required as per technical specification including connections, testing and commissioning of following sizes:
-
-
99267
... More
"Supply, fixing, testing commissioning of MS switch boxes of the following size made 3 out of 16 SWG MS sheet duly painted/coated with red oxide primer with egg white hylem sheet 3mm thick as per tech specifications, ISS/IE Rules and site requirement Hylem sheet shall be larger than MS Boxes. (Note- The mS Boxes shall be with earthing bolts and hylem sheet shall be fixed with 0.4 Nos. brass machine screws and washers etc.) "
-
-
9015.2
... More
Supply of Piano type switch Type as per IS-4979-1968 (latest version)/Bell push as per 4 IS:4794 (Part-2)-1986 (latest version)/Flush type socket outlet as per IS 1293-1988 (latest version) & installation on the recesed switch box including cutting of phenole laminated sheet, connection, testing & commissioning as per technical specifications.
-
-
5507.2
... More
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.
100
18
1827
... More
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 6 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.
80
527
42238.4
... More
Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input 7 power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable )
20
2594
51888.4
... More
Supply, erection, fixing, testing & commissioning of Fresh air Fan size 12'' 220 V.AC.,50 Hz, ISI marked, to be approved by SrDEE/G/MB complete in all respect as per tech. specification / site requirement.
20
1892
37845
... More
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 9 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification.
20
4349
86989.8
... More
Design, Fabrication, Supply, Fixing and commissioning of Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 10 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.
25
4006
100172
... More
Earthing with 40mm dia GI Pipe class 'B', 3 meter along earth electrode as per IS 3043 11 (Latest version) to achieve earth resistances less than 5 ohms including construction of masonary enclosures with hinged cover plate of cast iron/RCC (Heavy duty with lifting arrangement) with locking.
24
3061
73479.84
... More
Supply, installation, testing & commissioning of complete 60 watt LED Street light 12 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.
30
4414
132447.6
... More
Supply & fixing of 5 Mtrs. Log hot dip Galavanized octagonal pole with foundation, base plate, with fixing of 01/02 No. arm 1000 mm for the fittings including smart pack Junction Box with 6 Amps MCB and terminals as per specification/site requirement.
30
12327
369810.6
... More
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor 14 cable cushioning, protective covering with second class bricks width wise, provision of cable route markerincluding making chase & plastering after laying of cable/digging of cable trench, sand as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.
-
-
255640
... More
Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep 15 as per relevant IS suitable for laying HDPE Pipe of 140 mm inner dia and 160 mm outer dia. & shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-1995 (latest version) included).
290
915
265567.5
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%