Northern Railway Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Northern Railway - NR Tender
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date27 Dec 2024
Closing Date20 Jan 2025
Tender Amount₹ 82,20,640.4
Costs
EMD
₹ 1,64,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Improvement In Illumination Of Washing Lines By Provision Of Pit Lights And Under Catwalk Lights At All Washing Lines Over Lko Division.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
1155-SrDEE-NR-LKO-LUCKNOW NR DIVISION-ELECTRICAL/NORTHERN RLYTender No
1155-SrDEE-NR-LKOTender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
1.5 sq mm 03
500
14
7435
... More
4.0 sq mm
20000
29
583400
... More
Earthing with 40 mm dia GI pipe class 'B' 3 meter long earth electrode as per IS:3043 04 (latest version) to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mmx 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing.
20
1983
39676.2
... More
Supply, Provision, testing & commissioning of Concentric pipe electrode type maintenance free earthing, with primary MS pipe 40 mm dia. 3000 mm long & secondary MS pipe 05 80mm dia. 3000mm long, class B class ISI mark confirming to IS:1239 including digging pit of size 5 feet X 5 feet X 10 feet and using enhancement chemical compound minimum 75 kgs. Suitable for 40 kA current carrying capacity having less than 1 Ohm earth resistance as per RDSO specification No. RDSO/PE/ SPEC/PS/0109(Rev.0-2008) or latest and As Per Technical Scope of Work.
4
12890
51561.52
... More
Supply and recessing/fixing on surface 6 SWG GI wire for loop earthing as required as per technical specification and As Per Technical Scope of Work.
2000
11
22480
... More
Supply, laying, connection & commissioning of G.I. strip 40x5 mm (Galvanized) 07 confirming to relevant IS as per IS:3043/1987 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement. As per technical scope of work.
50
75
3772
... More
Design Supply, fixing and commissioning of the LED based pit light fitting 18 watt, 08 input voltage 48 V AC as per PCEE Spec. CEE/NR/121-Elect/PS/2018(Rev-03) dt. 28/06/18 & CEE/NR/121- Elect/PS/2019(Rev-04) dt 04.11.2019 with correction dt.10.02.2020 or latest , Size of light fitting & fixture should be installation and fixing & grouting work should be done as per site requirement and As Per Technical Scope of Work.
360
3162
1138377.6
... More
Supply, fixing, testing and commissioning of 48V, 50 Hz LED based bulk head light luminary with IP-66 protection, impact resistance IK10 having system wattage22 watt complete with 09 antitheft mounting arrangement and suitable protection jaali as per site requirement and conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019(Rev-'4') or latest and as per site requirement and As Per Technical Scope of Work.
450
4166
1875069
... More
Supply, Installation testing & commissioning of suitable protection Jaali for Pit light made of MS angle 25X25X3mm & MS Jaali 25mm X 25mm, wire dia as 2mm. Work should be executed as per site requirement and As per Technical Scope of Work.
960
489
469708.8
... More
Supply, installation, testing and commissioning of step down Transformer outdoor type, 10 KVA with control panel, Specifications for transformer Input voltage Range 440 V AC, Output Voltage 48 V AC(=/-5%), Minimum 4 output terminals, type of colling oil cooled, Control card Easy 11 maintenance & service ability, Efficiency more than 95%, Winding copper Core mitered CRGO notching core material, display digital, temp rise 45 degree C above ambient, Frequency 50 Hz, Protections- Low/High voltage, control panel: Size & capacity of control panel should be as per transformer capacity 10 KVA & connected load . Both transformer & control panel should be approved be railway before installation as per site requirement and As per Technical Scope of Work.
3
121200
363600
... More
Supply of step down Transformer outdoor type, 10 KVA with control panel, Specifications for transformer Input voltage Range 440 V AC, Output Voltage 48 V AC(=/-5%), Minimum 4 output terminals, type of colling oil cooled, Control card Easy maintenance & service 12 ability, Efficiency more than 95%, Winding copper Core mitered CRGO notching core material, display digital, temp rise 45 degree C above ambient, Frequency 50 Hz, Protections- Low/High voltage, control panel: Size & capacity of control panel should be as per transformer capacity 10 KVA & connected load . Both transformer & control panel should be approved be railway before installation as per site requirement and As per Technical Scope of Work.
2
109080
218160
... More
35-185 Sq.mm,4 core
20
3897
77956
... More
Supply, erection, testing and commissioning of End termination of 3-1⁄2 C / 4.0 C X 70 to 240 sq. mm. LT XLPE cable as per specification. (One set means lugs in R-Y-B-N).
40
368
14750.8
... More
2X70-150 sq mm cable
20
174
3489
... More
Supply, laying, fixing, testing and commissioning of LT straight through joints for 2 16 core 25 / 70 / 150 sq. mm along with loop of cable, complete as per ISS/IE rules and site requirement and satisfaction to the Railway representative. ( only LT cable supplied by the Railway) and As Per Technical Scope of Work.
10
1666
16669.1
... More
Laying of 1.1 KV grade LTXLPE insulated armoured, aluminum conductor cable of different sizes as per site incharge and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables and As Per Technical Scope of Work.
4000
10
40000
... More
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 18 earth as per site incharge and as per cable route plan. so as not to form a drain. Size of trench should be 0.3 Mtrs. Wide & 1 Mtr. Deep as per cable plan and instructions of SSE/incharge. It shall conform to the safe distance as per cable plan. It also includes clearance of roots of trees & bushes and As per Technical Scope of Work.
1000
87
87890
... More
Excavating and refilling of trench 0.3 Mtr. Wide & 1 Mtr. Deep from bottom of rail 19 flange across the track or0.5Mtr. from ground level which ever is more as per site incharge and as per cable route plan. Earth should be rammed so as not form a drain. This includes removal and refilling of ballast and restoration of surface under normal traffic conditions and As Per Technical Scope of Work.
200
114
22888
... More
Supply and laying of 2nd class new bricks in the trench and laying as per instructions of the site Engineer.
10000
9
93000
... More
Clamping of cable with wall / trusses / cable tray / angle with help of Nut, Bolt & washer. The clamp made out of GI strip size not less than 32X5 mm. : (Note : Cable will be supplied by the Railway from Store of SSE/Elect) and As per Technical Scope of Work.
500
28
14480
... More
All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. 22 RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc. as per instruction of site engg. by using pipe of size-120 mm outer dia, 103.5mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level and As per Technical Scope of Work.
100
2234
223433
... More
Supply and laying of HDPE (High Density Poly Ethylene polymers) pipe of Material 23 Grade- PE 63 grade, IS 4984 Resistance to chemicals-Exceptional resistance to all external and internal corrosion. Resistant to electrolytic corrosion. Working pressure in KGF/CM2)Specified base density- 940 to 958 kg/mtr3, Size-(a) HDPE pipe outer diameter 63 mm, wall thick Min. 3.0mm & Max 3.5 mm and As per Technical Scope of Work.
200
132
26470
... More
Supply, erection, testing, and commissioning of 5 meter high hot dip Galvanized octagonal pole with longitudinal seam weld throughout the length with bottom 130 mm across face, 24 top 70 mm across face made of 3 mm thick high tensile plate and 200 mm X 200 mm X 12 mm base plate complete with two arm of 300 mm for fitting installation and 04 No. M20 (EN 8 Gr) X 700 mm long J type foundation bolt set complete with washer and smart pack junction box with suitable single pole MCB & terminal as per explanatory note. Double Arm and As per Technical Scope of Work.
50
9625
481289.5
... More
Supply, erection, testing and commissioning of LED street light fitting complete with 25 driver (45 watts) confirming to CEE/NR specification No: CEE/NR /121- Elect/PS/2018(Rev -'3' ) Dated : 28/06/18.High power LED ( 1 watt), LED make- NICHIA/ OSRAM/ SAMSUNG/ LUMILEDS/ CREE/SEOUL, lumen output 150 lumens/watt, LED life expectancy 50000 burning hours, Ingress protection :- IP 20. . The guaranty shall be Five years from date of commissioning.
100
4691
469105
... More
supply, installation , fabrication and installation of perforated GCGI tray of size 300mm 26 X 75mm deep X 1.6 mm thick including horizontal and vertical bends , reducers , tees , cross members and other accessories duly galvanized and supporting/mounting with pillar /angle structure /wall as required at site and As per Technical Scope of Work.
1200
933
1120560
... More
Supplying and fixing 8 way, sheet steel, MCB double door distribution board, 240 V, on 27 surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. a) DP MCB 25-32 A,10 KA "C" curve (incoming)-1 No, b)25A DP RCCB = 01 No. having a sensitivity current 30 ma c) 6-32A ,10 KA MCB SP "C" curve = 04 Nos.(Outgoing) and As per Technical Scope of Work.
15
6281
94215
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%