Northern Coalfields Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Northern Coalfields Limited - NCL Tender

Eprocure
Opening Date19 Aug 2021
Closing Date23 Sep 2021
Tender Amount₹ 6,74,75,86,100 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design Engineering Cost

-

-

-

... More
a. Preparation and submission of system engineering drawings as per system requirements

1

-

-

... More
b. GA & detail engineering designs and drawings of all civil and structurals developmental and infra-structural included in the system and scope of works (complete details of the system)

1

-

-

... More
G.A. & detailed engineering designs and drawings including working and maintenance manuals of : i) All individual equipment ( Mechanical & Electricals) ii) Dust Control & Pressurisation system. iii) Fire-fighting and plant cleaning system. iv) Chutes & Liners v) Communication system vi) Power Supply System vii)Illumination system. ix) Plant control system x) OHE System x) Any other system/unit to match the scope of work & requirement COMPLETE DETAILS OF THE SYSTEM

1

-

-

... More
Documentation as per tender specification (complete as per scope of work

1

-

-

... More
B CIVIL & STRUCTURAL WORKS

-

-

-

... More
Truck Receiving Steel Hopper ( 4x100Te 2sets)

1

-

-

... More
Truck Receiving Platform with Ramp/Approach Road and Retaining wall

1

-

-

... More
Semi-mobile crusher with 150Te hopper : Truck Receiving Platform with Ramp/Approach Road, Retaining wall and supports

1

-

-

... More
Conveyor galleries with all supporting arrangement

1

-

-

... More
Transfer Houses, Drive House, Sampler House, Secondary sizer-cum-Transfer House

1

-

-

... More
20000 Te Over Ground Bunker With maintenance bay

1

-

-

... More
4000 Te Silo with Lift Well

1

-

-

... More
Developmental work and infra-structure

-

-

-

... More
CHP Office Complex

-

-

-

... More
CHP office

1

-

-

... More
Rest Shelter

1

-

-

... More
Canteen (25 seater)

1

-

-

... More
First Aid centre

1

-

-

... More
Security post/time office

1

-

-

... More
LMV/Car Parking Shed

1

-

-

... More
Scooter/motor cycle Shed

1

-

-

... More
Electrical maintenance cum testing room

1

-

-

... More
Store Complex

-

-

-

... More
Store shed

1

-

-

... More
Store room

1

-

-

... More
Electrical sub-stations

1

-

-

... More
Lighting Mast

1

-

-

... More
Internal Approach Cement Concrete Road 3.75m wide carriage-way

1

-

-

... More
Drains, Culverts

1

-

-

... More
Boundary wall with gate, Barbed wire fencing

1

-

-

... More
Ground Water Reservoir with Pump House

1

-

-

... More
Water Supply distribution

1

-

-

... More
Collection sumps and arrangement for conveying of Industrial Effluent to existing ETP

1

-

-

... More
Sewerage

1

-

-

... More
Site Development (includes OB removal, levelling and storm water drains, channelizing existing nallah, embankment for roads, Landscaping and Arboriculture and other misc. items of work)

1

-

-

... More
C. PLANT & MACHINERY ( SUPPLY)

-

-

-

... More
C.(a) SUPPLY : MECHANICAL

-

-

-

... More
A. CONVEYORS

1

-

-

... More
B. BELTING

1

-

-

... More
C. EQUIPMEMT

-

-

-

... More
Receiving Section Mechanical Equipment

1

-

-

... More
Mechanical equipment in secondary sizer section

1

-

-

... More
Mechanical Equipment in Storage Section

1

-

-

... More
Mechanical Equipment at Transfer house

1

-

-

... More
Mechanical equipment at Loading Complex

1

-

-

... More
Mechanical Equipment required for dovetailing in existing system with due modification.

1

-

-

... More
OHE Equipment including mechanical, electrical and civil requirement

1

-

-

... More
Other mechanical equipment

1

-

-

... More
Dust suppression system with piping & other accessories. Condition monitoring system, Safety & firefighting system , and other misc. equipment/utility for any more item required to complete the project

1

-

-

... More
C.(b) SUPPLY : ELECTRICAL

-

-

-

... More
ELECTRICAL

-

-

-

... More
Substation-A(SS-1) 33 kV Lightning arrestor,Isolator with/without earth switch,outdoor Vacuum Circuit Breaker, outdoor CT & PT, DO fuse etc. As required. 33/6.6 KV, 16 MVA,ONAN outdoor transformer with Nitrogen injection fire fighting system -2nos. 6.6 kV Lightning arrestor, Isolators with/without earth switch, outdoor VCB, outdoor CT/PT, DO Fuse etc. as required. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 6.6/0.433 kV, 400 KVA Distribution transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, (Indoor VCB with indoor control pannel) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs complete with metering and protection as required MCC at Substation-A Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 415V,Aluminium Bus-duct as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-B(SS-2) Power receiving arrangment from substation A(SS-1) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 400 KVA Distribution transformer-2nos. 6.6/0.230 V (L-L), 100 kVALighting Transformer-2nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 2A & 2B (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs complete with metering and protection as required. 415V,Aluminium Bus-duct as required. MCC at Substation-E2 Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kV Two numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-C(SS-3) Power receiving arrangment from substation B(SS-2) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 500KVA Distribution transformer-2 nos. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 3A (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs, Metering and protection as required. 415V,Aluminium Bus-duct as required. MCC at Substation-C Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kV Two numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-D(SS-4) Power receiving arrangment from substation E(SS-5) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 750KVA Distribution transformer-2 nos. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 4A (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs, Metering and protection as required. 415V,Aluminium Bus-duct as required. MCC at Substation-D Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kV Two numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-E(SS-5) Power receiving arrangment from substation A(SS-1) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 500KVA Distribution transformer-2 nos. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 5A&5B (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs, Metering and protection as required 415V,Aluminium Bus-duct as required. MCC at Substation-E Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kVTwo numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-F(SS-6) Power receiving arrangment from substation A(SS-1) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 1600KVA Distribution transformer-2 nos. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 6A&6B (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs, Metering and protection as required 415V,Aluminium Bus-duct as required. MCC at Substation-F Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kVTwo numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Substation-G(SS-7) Power receiving arrangment from substation F(SS-6) with Lightning Arrester and Isolator with earth switch as required. 6.6/0.433 kV, 750KVA Distribution transformer-2 nos. 6.6/0.230 V (L-L), 100 KVA Lighting Transformer-2 nos. 220V Lead Acid Battery complete with Battery Charging unit.-1 no. 6.6 kV 3 Phase, 3 Wire Switchboard 7A (Indoor ) Comprising of Incomer VCB, Buscoupler VCB and Outgoing VCBs/VCPs, Metering and protection as required 415V,Aluminium Bus-duct as required. MCC at Substation-G Comprising of Incomer ACB, Buscoupler ACBs and Outgoing ACBs/MCCB/SFU/ Contactor as required. 6.6 kV and 415 V Capacitor with Automatic power factor correction of required capacity Banks for power factor improvement as required. 6.6 kV Two numbers of Single Circuit Overhead line comprising of AAAC ’Wolf’ equivalent Conductor for power supply as required. Fire detection, Alarm and Protection system.

1

-

-

... More
Cables Power Cables Control & Signalling Cables Lighting Cables & Wires Communication Cables

1

-

-

... More
Earthing Plant Equipment Earthing Structures Earthing Earthing for Lighting Protection Transformer neutral Earthing

1

-

-

... More
Welding Sockets and 7 number of Electical & Diesel Welding Set

1

-

-

... More
PLC System for Control & Automation,Interlocks, Signalling and instrumentation of entire CHP.

1

-

-

... More
Remote and sequence control equipment & Accessories

1

-

-

... More
Cable Trays, Cable Racks, Cable Trenches, Cable Voults etc.

1

-

-

... More
Illumination System and Luminaires, Lighting poles & Towers, Lighting DBs etc.

1

-

-

... More
DG sets for Emergency Power Supply.-7 nos.

1

-

-

... More
Exhaust Fan, Ceiling Fan, Air Conditioner, insulating Mats etc.

1

-

-

... More
Computers and Peripherals

1

-

-

... More
Communication System

1

-

-

... More
Miscellaneous Equipment

1

-

-

... More
C1. ERECTION, INSTALLATION & COMMISSIONING

-

-

-

... More
Erection of mechanical equipment

1

-

-

... More
Erection of electrical equipment

1

-

-

... More
Erection of other plant and machining etc.

1

-

-

... More
Trial run, and commissioning of the plant

1

-

-

... More
C2. OTHERS ITEM

-

-

-

... More
Drinking water system consisting of tanks, pipes, valves, taps etc.

1

-

-

... More
Plant cleaning system

1

-

-

... More
Any other item left out for completion of the project

1

-

-

... More
C3. MAINTENANCE AND TRAINING

-

-

-

... More
Operation of the plant for five years as described in Tender document

1

-

-

... More
Maintenance of the plant for four years as described in Tender document

1

-

-

... More
Training of the employer personnel as per tender document

1

-

-

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.