North Eastern Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Eastern Railway - NER Tender

Works
Telecommunication Services
Ireps
Opening Date1 Jul 2024
Closing Date25 Jul 2024
Tender Amount₹ 16,87,29,170.91 
Notes
Download

Costs

Summary

Work For Survey, Design, Supply, Installation, Testing & Commissioning Of Automatic Block Signaling Work Using Multi Section Digital Axle Counter

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Tool Kit for Digital Axle Counter (suitable for MSDAC complying to the RDSO Specification No. RDSO/SPN/176/2013/Ver.3 or latest) & Test Panel including Meter for testing of track equipment, tools for monitoring & adjustment of track equipment and standard jig for drilling holes in a rail. It should be as per principal manufacturing (OEM) recommended list adequate for installation, day to day 02 maintenance and adjustment of indoor and outdoor gears. The tool kit shall be equipped with the atleast following minimum equipments: (i). All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii). Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set- 1 no. (iii). Adjustable Torque Wrenches 25-135 N/mtr with 13 mm and 19 mm inserts-1 Set. (iv). Set of spanners screw drivers and soldering iron -1 set. (v). Dummy wheel- 1 no. (vi). Marking jig -1 no. (vii). Adapter card-1 no. (viii). Extended wired socket to interface with diagnostic plug -1 no. (ix) Selector switch on panel base-1 no. (x). DAC EC card puller. (xi). Any other tools required for maintenance purpose.(Inspection by CONSIGNEE)

1

124343

124343.23

... More
Supply of one set of Track Device (including Tx and Rx) with 10 metre cable length suitable for one Detection Point of MSDAC as spare as per RDSO's specification No. RDSO/SPN/176/2013 (Ver.3) or latest. (Inspection by RDSO)

15

52886

793298.7

... More
Supply, installation, wiring, testing & commissioning of domino type LC gate signal control panel 01 suitable for ABS territory as per drawing approved by NE Railway Drg No. NER/TYP/LC-DOMINO PNL/2021/31 (and as per instruction in Letter No. N/571/1/Drg./Policy/Pt.-13 dated 31.12.2021) and as per technical specification & scope of work mentioned in tender document. (Inspection by Consignee.)

4

31498

125992.24

... More
Supply of Colour Light Signal Post, Tubular Mild Steel, 4.5 m length, 140 mm Dia, as per RDSO 01 Spec. No. IRS: S-6/81 with latest amendments/ revision and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M with latest amendments/ revision), with CLS ladder assembly suitable for colour light signal of 4.5 m long, as per RDSO drg. No. SA 23153 and complete assembly of signal front & back staging for CLS unit. (Inspection by RITES.)

40

25924

1036979.6

... More
Supply of Offset Bracket for colour light signal Main unit, with fixing U clamps & nuts etc., as per RDSO Drg. No. SA 23080 (Adv.) with latest amendments. (Inspection by Consignee.)

40

1237

49506.4

... More
Supply of Junction route indicator unit 1 way, made of FRP (without lenses & holder) as per Drg No. 03 SA 23401-06 (Adv) (as applicable) suitable for LED Signal Lighting unit and as per RDSO Spec. IRS:S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 (Rev.2) or latest.(Inspection by RITES. However, items not covered under RITES will be inspected by consignee).

10

45600

456007.7

... More
Supply of Four Aspect Non Metallic (FRP) colour light signal housing multi unit type for Railway 04 Signalling suitable for RE area, complete without lenses, lamps and signal transformer as per RDSO Drg No. SA 23001 A/M (Adv) and as per RDSO Spec No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. (Inspection by RITES.)

40

43318

1732731.6

... More
Supply of hand cuff lock with key of approved type & standard make for locking signal unit door. (Inspection by consignee.)

100

168

16880

... More
Supply of Apparatus Cases (full location box) as per RDSO Drawing No. RDSO/S-11500 or latest with miniature E type locks & keys. The key & handle shall be supplied at the rate of one set per four Apparatus 06 Case. The miniature 'E' type lock shall be as per RDSO Specification No. IRS: S-30/64 or latest and of ward no 41or as required by consignee & RDSO Drg No SA 3473/M & SA 3474 A or latest and key as per RDSO Drawing No. 3377/M or latest. E type locks are to be fitted on both front & back doors of location box. (Inspection by RITES.)

100

28207

2820794

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per specification No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection by consignee)

70

5901

413116.9

... More
Supply of Fuse Block made of PBT/Polycarbonate material as per RDSO Specification No. IRS:S- 75/2006 (Rev.2) & RDSO Drg.no SA-23748 or latest from RDSO approved sources. (Inspection by RDSO.)

300

122

36759

... More
Supply of Non-deteriorating type low voltage cartridge fuse rated current 1/2/4 Amp, round head type as per RDSO spec no. IRS.S 78/2006 with latest amendments/ revision from RDSO approved sources. (Inspection by RDSO.)

500

97

48775

... More
Supply of Non-deteriorating type low voltage cylindrical head cartridge electric fuse 6/10 amp as 10 per RDSO specification No. IRS/S/78/2006 with latest amendments/ revision from RDSO approved sources. (Inspection by RDSO.)

200

103

20682

... More
Supply of ARA Terminal Block made of PBT - 6 Way as per RDSO Spec. No. IRS: S75/2006 (Rev. 2) or latest & Drg. No.SA-23756 (Alt-4) or latest from RDSO approved sources. (Inspection by RDSO.)

1000

271

271820

... More
Supply of ARA terminal block PBT 1 Way 60mm centre as per RDSO DRG. No. SA-23745 ALT. 5 and spec No. IRS:S:75/2006 with latest amendment if any. Inspection -RDSO.

300

72

21798

... More
Supply of bus bar 50 way as per technical specification attached,inspection-consignee.

50

695

34780

... More
Supply of PVC Insulated, Indoor cable, single core, 1.0 mm, flexible, as per RDSO Specification No. IRS-S-76/89 (Amndt. -3) or latest. Coil should be of different colours, each coil in 100 m length. (Inspection by RITES. However, items not covered under RITES will be inspected by consignee)

1000

7

7240

... More
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire, 85 conductor each dia 15 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire will be specified by the Engineer incharge.(Inspection Consignee with )

1000

49

49180

... More
Supply of 1 x 10 Sq mm (Red/Black/Green) multi strand copper power wire, 101 conductor each dia 16 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire will be specified by the Engineer incharge. (Inspection by RITES. However, items not covered under RITES will be inspected by consignee)

1000

128

128760

... More
Supply of 1 x 16 Sq mm (Red/Black/Green) multi strand copper power wire, 101 conductor each dia 17 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest & and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire which is required will be specified by the Engineer incharge.(Inspection by RITES. However, items not covered under RITES will be inspected by consignee)

2000

151

303020

... More
Supply of 16/0.2 mm (0.5 sq mm) PVC insulated, multi strand single core, tinned copper conductor as per RDSO Specification No. IRS: S-76/89 (Ammdet-3) or latest from RDSO approved sources. Each coil shall be of 100 meters. (Inspection by RDSO.)

20000

11

223200

... More
Supply of Q-Series Universal type QECX-61 AC LED lamp proving relay (ECR) of 4F-4B contacts 19 with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:941A, STS/E/RELAYS/AC LED SIGNAL/09-2002, Amndt.1 or latest and RDSO Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection by RDSO.)

210

6988

1467654.3

... More
Supply of Q-Series Neutral Line Relay, non-AC immunized (QN1 type), 8F/8/B, 24V DC complete 20 with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:930 and RDSO Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1, S@45<45@78 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection by RDSO.)

400

4169

1667796

... More
Supply of Q-Series Line Relay, AC immunized (QNA1 type), 8F/8/B, 24V DC complete with plug 21 board (base plate), connectors, retaining clip etc. and conforming to BRS:931 and RDSO Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1, S@45<45@78 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection by RDSO.)

200

4569

913908

... More
Supply of main LED signal lamps of Green aspect with inbuilt current regulator as per RDSO Specification No. RDSO/SPN/199/2010 Revision 1.1 or latest retrofittable in existing CLS housing & compatible with AC LED ECR from RDSO approved sources. (Inspection by RDSO.)

45

10142

456430.95

... More
Supply of main LED signal lamps of Red aspect with inbuilt current regulator as per RDSO Specification No. RDSO/SPN/199/2010 Revision 1.1 or latest retrofittable in existing CLS housing & compatible with AC LED ECR from RDSO approved sources. (Inspection by RDSO.)

45

8938

402228

... More
Supply of Route LED Signal lighting unit 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2023 revision 5 or latest. (Inspection by RDSO.)

50

6178

308933

... More
Supply of "A" Marker LED Signal Lighting Unit retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 revision 4.1 or latest. (Inspection by RDSO.)

45

6133

275992.2

... More
Supply of "AG" Marker LED Signal Lighting Unit retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 revision 4.1 or latest. (Inspection by RDSO.)

12

6133

73597.92

... More
Supply of Medium class GI pipes of 100 mm diameter (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest along with couplers at one side in 6 meter length & along with test report of manufacturer. (Inspection by RITES.)

3000

1016

3050520

... More
"SUPPLY OF DOUBLE WALLED CORRUGATED (DWC) PIPES (ELEX/ TELEREX/ OPTIREX/ OR SIMILAR)as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 & Amendment 1 or latest,FOR 29 UNDERGROUND POWER/ COMMUNICATION/ SIGNAL/ OFC/PROTECTION WITH IS 14930 PART -II MARK ON DULY PRINTED AT EVERY ONE METER INTERVAL IT ALONG WITH THE SOCKET/ COUPLER AND T JOINT WITH ""IP 67"" PROTECTION FOR COUPLING WHERE EVER REQUIRED. THE HDPE PIPE SHALL BE RODENT PROOF AND FIRE RESISTANT AND :SIZE OF OUTER DIA 90 MM/ INNER DIA 76 MM. INSPECTION - RITES."

4000

261

1045480

... More
Supply of HDPE duct of 40/33 mm in Drum length of 500/1000 meter length as per RDSO Specification RDSO/SPN/TC/ 45/ 2013 revision 2.0 (Amdt. 2.0) or latest either from RDSO or TEC approved firms along with test report of manufacturer. (Inspection by RITES.)

80

78753

6300277.6

... More
Supply of 4 conductor Disconnect type Terminal Block with screwing cage/ clamp type, sliding switch disconnect as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest for each conductor size up to 2.5 sqmm along with accessories from RDSO approved sources. (Inspection by RDSO.)

8000

99

796640

... More
Supply of End and Intermediate plate 2.5 mm/0.098 in thick of Wago or Phoenix make or similar suitable for Disconnect type Terminal Blocks as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest from RDSO approved sources. (Inspection by RDSO).

8000

21

175520

... More
Supply of Screwless End Stop 10 mm/0.394 in wide carrier wide rail din 35 of Wago or Phoenix make or similar suitable for Disconnect type Terminal Blocks as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest from RDSO approved sources. (Inspection by RDSO.)

1000

21

21910

... More
Supply of Steel Carrier Rail of size 35x7.5 mm of Wago or Phoenix make or similar suitable for Disconnect type Terminal Blocks as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest from RDSO approved sources. (Inspection by RDSO)

100

178

17829

... More
Supply of Thermo Shrink Jointing Kit (RTSF4) as per RDSO Specification No. IRS TC-77-2012 35 (Rev.3) or latest suitable for 6 quad jelly filled cables for straight through/ derivation joints including supply of all the accessories from RDSO/TEC approved sources & along with test report of manufacturer. (Inspection by RDSO.)

50

2166

108310

... More
Description: 48 Fiber, Splice joint Closure for Optical Fiber Cable Armoured and metal free type OFC with Screws Sealing as per the following specification.Product description. Spice closure for optical Fiber 36 Cables Suitable for Non- Ribbon splicing used in Telecom Network, Conformity of specification: as per TEC/GR/TX/OJC-002/03/APR- 2010,Suitable to use it for: Armoured and Metal free type OFC, The Splice closure shall be equipped and supplied with accessories for the installation of: All type of cables having outer dia from 8mm to 18mm, The splice closure suitable for splicing of OFC with Single mode fibers, asper ITU Rec.G.652,G.655, and G.6560Cable, The life of closure, minimum (in Years): 25, Construction of splice closure: Base and domed shaped body, Material of base and dome: Polypropylene, DIMENSION: Minimum length of Splice closure main body (in mm): 403, Maximum internal diameter(in mm): 220, minimum cable entry ports 4 single cable entry port and 1 port for looped cable entry, All cable entry ports: Independent to each other, SIZE OF THE CASSETTE (Splice Tray), Minimum length (in mm): 200, Minimum width (in mm): 90, minimum thickness(in mm): 1.5, Depth (in mm):5, The minimum vending diameter allowed for the fiber coils inside the splice tray(in mm): 75, Arrangement to hold protection sleeves in the splice tray Yes for 12 Nos., Possible to fix secondary tubes at the entry of ports of each tray: Yes for 4 secondary tubes, Each tray shall have the capacity to store: 12 Primary/secondary coated fibers.(inspection-RDSO)

80

2283

182664

... More
Supply of Office Almirah of size 900 (W) x 1168.5 (H) x 450 (D) mm as per model No. KD MNOR with metal top of Godrej make or similar. (Inspection by Consignee.)

6

35487

212927.16

... More
Supply of Table of size 1370 (W)x740(H)x690 (D) mm as per Model No. T-9 of Godrej Make or similar. (Inspection by Consignee.)

3

17620

52860.87

... More
Supply of Chair of model OXBO with High Back of Godrej make or similar. (Inspection by Consignee.)

3

16963

50891.4

... More
Supply of Chair Superior Quality with Arm and Cane seated of size 57(D)x58(W)x88(H) and seat height of 45 mm of model no. classic CH-7 of Godrej make or similar. (Inspection by Consignee.)

3

3922

11768.67

... More
Supply of Micro Processor based Data Logger System with 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power 41 supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, ELD, MSDAC etc., interlinking and networking of Data logger, interfacing with EI. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.Note:- railway will provide fibre connectivity at location, interfacing connectivity requirement with adjacent station, data logger which is of efftronics make shall be provided by the contractor free of cost. (Inspection by RDSO)

2

332088

664177.76

... More
Supply of T-Networking Modem for connecting RTU/data logger with existing Data logger/RTU as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest. (Inspection by Consignee.)

2

23544

47088.36

... More
Supply of Maintenance Console along with Inkjet Printer, 1 KVA UPS of minimum 30 minutes capacity and one set of table & chair for Datalogger/RTU for online tracking & monitoring of data of station/auto relay huts as per Technical Specifications mentioned in Tender Documents. (Inspection by Consignee.)

2

101321

202642.5

... More
Supply of Optical Power Meter having resolution of 0.1 db & measuring range +3 dbm to -60 dbm as per TEC specification No. GR/OPM-01/03 Feb 05 or latest. (Inspection by Consignee.)

1

18191

18191.2

... More
Supply of Insulation Resistance Tester 500V DC, 100 Mega ohm, hand generator type. Make: Meco/Motwane/Waco or similar. (Inspection by Consignee.)

1

18281

18281.5

... More
Supply of Insulation Resistance Tester 100V DC, 100 Mega ohm, hand generator type. Make: Meco/Motwane/Waco or similar. (Inspection by Consignee.)

1

16088

16088.76

... More
Supply of Digital Clamp Earth Tester/Meter with storage facility of Model DET20 of Motwane make or Meco or Fluke or better. (Inspection by Consignee.)

1

117847

117847.33

... More
Supply of Digital Multimeter of model No. Fluke 287 of Fluke make or better. (Inspection by Consignee.)

2

76480

152960.54

... More
Supply of Digital AC/DC Leakage Current Clamp on Meter of Model CL360 of Yokogawa or DCM 39A of Fluke make or similar model of Motwane make or better. (Inspection by Consignee.)

1

59741

59741

... More
Supply of Magneto Telephone Desk Type as per RDSO Spec IRS-TC-79/2000 or latest. (Inspection by Consignee.)

10

3549

35493.9

... More
Supply of Tag blocks 120 way with Polycarbonate cover as per IRS: S-77/2006 (Rev. 1) or latest, as per drawing no. SA-24751, SA-24752, SA-24753 respectively. (Inspection by Consignee.)

26

1450

37716.9

... More
Supply of PVC Indoor Cable 1x60x0.6mm dia Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Grey,Green, Brown & Black conforming to IRS 76/89 (Amd. 3) or latest from RDSO approved sources. (Inspection by Consignee.)

1000

308

308270

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd. 3) or latest from RDSO approved sources. (Inspection by Consignee.)

1000

202

202720

... More
Supply of Calling ON Signal Unit without lenses and lamps and with offset bracket 3.5" dia as per RDSO drawing No. SA-24351(Adv) alter 1 or latest.(Inspection by RITES. However, items not covered under RITES will be inspected by consignee)

60

4705

282330.6

... More
Supply of portable Work Station Note Book for doing programming & data analysis in the filed as per Technical Specifications mentioned in Tender Documents of make-HP/DELL or superior. (Inspection by Consignee on OEM test certificate.)

2

87842

175685

... More
Supply of Laserjet Printer for taking print out of various field data for analysis as per Technical Specifications mentioned in Tender Documents of make- HP/Canon/Epson or superior. (Inspection by Consignee.)

2

29369

58738.66

... More
Supply and installation of Cable Termination (CT) rack as per drawing of NE Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements and also with 01 arrangement for fixing Disconnect type terminal blocks/ ARA terminals. The CT rack shall be covered with Phenolic Laminated Sheet of minimum 10 mm thickness for fixing of Disconnect type terminal blocks/ ARA terminals. Cable termination rack shall be corrosive resistant and power coated. Note: Supply of Disconnect type terminal blocks/ ARA terminals not covered under this item. (Inspection by Consignee.)

6

33235

199411.68

... More
Fabrication, supply and installation of Power Supply Distribution Rack made of MS Angle of Size 40mm x 40mm x 6mm (similar to Cable Termination rack) as per drawing of NE Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements in IPS Room. The Power Supply Distribution rack shall be covered with Phenolic Laminated Sheet of minimum 10 mm thickness for fixing of Fuse terminal blocks/ ARA terminals. This includes supply & fixing of standard size ladder suitable for indoor cable 02 made of MS angle of size 25mm x 25mm x 5mm from Battery Room to IPS Room and from IPS Room to Relay room for taking power cables. Power Supply Distribution Rack & ladder rack shall be corrosive resistant and power coated. This also includes fixing of required nos. Fuse Terminal Blocks & ARA Terminals on laminated sheet as per power supply distribution diagram and laying of required nos. of power cables from Power Supply Distribution Rack to Relay Room & Battery Room of various supply in ring protection & terminating with help of crimped copper lugs of suitable sizes duly supported on ladder with proper lacing & dressing. Various sizes of lugs for terminating power cables are to be supplied by contractor. Note: Power cables, fuse terminal blocks & ARA terminals not covered under this item. (Inspection by Consignee.)

3

24711

74135.94

... More
Supply, installation, fixing, wiring, testing & commissioning of Fuse Auto Changeover System 03 (FACS) for Railway Signaling System as per RDSO Specification No. RDSO/SPN/209/2012 Ver.2 or latest for Relay room suitable for fuses from 0.63 Amp to 4 Ampere capacity for 12V/24V/60V/110V DC and 110V AC systems. One FACS Unit shall compromise 32 nos. of non-deteriorating or 'G' type fuses of various capacity. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no. of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio-visual alarm for main and standby fuses shall be provided. Installation, wiring, testing & commissioning of FACS consists of fixing of modules of fuse alarm system on existing rack, wiring from existing fuses to modules, soldering, lacing etc. Work is to be executed without affecting the functioning of existing circuits/ gears. (Supply portion of FACS shall be inspected by RDSO and execution portion by Consignee.)

2

42111

84222.58

... More
Supply, installation, wiring, testing commissioning of Earth Leakage Detector (ELD) of 8 channel, 04 voltage of 110 Volt/60 V/24V/12V in AC/DC as per RDSO Spec. No. RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming supply wires. Installation to be done on 19-inch sub-rack along with insulation resistance meter, indication & buzzer. (ELD to be inspected by RDSO.)

2

165283

330566.56

... More
Supply, installation, wiring, testing & commissioning of Microcontroller based Quad cable conductor Earth Resistance sensing unit for 24 nos. of conductors having NO & NC contact for remote monitoring as per Technical Specification mentioned in Tender Document. (Inspection by Consignee.)

4

87189

348759.12

... More
Supply, Installation, Wiring, Testing & Commissioning of Networkable type Microprocessor based Addressable, Automatic Fire Detection & Alarm System (AFDAS) consisting of Control Panel & other accessories as per RDSO spec. No. RDSO/SPN/217/2021 Ver 3 or latest from RDSO approved sources. The number of detector and devices per loop should be up to 159. The AFDAS shall include a backlit min 360-character liquid crystal display, individual, color coded system status LEDs, 2 Nos sounder circuit for audiovisual devices and 06 alphanumeric keypad for the field programming and control of the fire alarm system. The AFDAS shall have provision for GSM based dialer to send automated SMS to at least 5 pre-selected mobile numbers. The AFDAS shall also have provision to network on LAN & communicate to the graphical application on TCP/IP. The AFDAS shall have built in power supply, battery charger and battery backup for 24 hours normal operation. The panel shall be UL/LPCB/VDS approved and comply to NFPA-72/EN54 requirement. This also consists of supply execution of following items to make complete system functional as per RDSO specification. All required accessories to make the AFDAS fully functional are to be supplied by contractor. (Inspection of supply portion by RDSO.)

2

105107

210214.94

... More
Supply, Installation, Wiring, Testing & Commissioning Analogue Addressable Multi sensor Detector with inbuilt isolator/ isolator base having photo, fixed heat and ROR heat detection feature and 360-degree view 07 LED and minimum 5 level of sensitivity setting, complying to RDSO/SPN/217/2021 Ver 3 or latest. Operating temperature -10 to 60 degree Celsius, humidity up to 85%, as per latest UL/LPHB/VDS approved/listed, suitable for Automatic Fire Detection & Alarm System (AFDAS). (Inspection of supply portion by RDSO.) (Note: 8 nos. of sensors per Auto Relay Hut.)

12

3284

39409.8

... More
Supply, Installation, Wiring, Testing & Commissioning of Analogue Addressable type & Resettable 08 Manual Call Point (Red colour) with back box & with inbuilt fault isolator or alternate arrangement which shall isolate the MCP in case of short circuit, suitable for Automatic Fire Detection & Alarm System (AFDAS). The MCP should have visual indication for its operation. Approval/listed - UL/ LPCB/ VDS and shall comply to RDSO/SPN/217/2021 Ver 3 . (Inspection of supply portion by RDSO.)

2

4510

9021.28

... More
Supply, Installation, Wiring, Testing & Commissioning Isolator Modules as per RDSO Specification N o . RDSO/SPN/217/2021 Ver 3 or latest, suitable for Automatic Fire Detection & Alarm System (AFDAS). (Inspection of supply portion by RDSO.)

2

7004

14008.64

... More
Supply, Installation, Wiring, Testing & Commissioning of Control Module with backbox & inbuilt fault isolator to address sounder cum strobe as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3 or latest, suitable for Automatic Fire Detection & Alarm System (AFDAS). (Inspection of supply portion by RDSO.)

2

7085

14170.38

... More
Supply, fixing, laying of Fire survival integrity cable 2x1.5 sq.mm un-armoured as per RDSO specification No. RDSO/SPN/217/2021, Ver.3 or latest, suitable for Automatic Fire Detection & Alarm System 11 (AFDAS). This work involves supply, fixing & laying of cables inside PVC pipe/capping casing duly connecting all the detectors/ sensors, sensing cable, manual call points, control panel. This also include supply & fixing of PVC pipe/ casing capping of 25mm size of IS standards on wall/roof including supply of all accessories like bents, screw, nails etc. as directed by the Railway Site Engineer. (Inspection of supply portion by RDSO.)

80

204

16350.4

... More
Supply, Installation, Wiring, Testing & Commissioning of Audio-Visual Alarm (Electronic Hooter & 12 Strobe) with back box controlled through addressable control panel, suitable for Automatic Fire Detection & Alarm System (AFDAS). It shall be preferably flashing type of Red/White colour. The sound level shall be preferably adjustable type up to 90dB at a distance of 1 meter and shall be complying to RDSO/SPN/217/2021 Ver 3. (Inspection of supply portion by RDSO.)

2

7667

15335.8

... More
Supply, installation & commissioning of CO2 Fire Extinguisher 4.5 Kg capacity confirming to IS 15685 with ISI mark provided with all fittings & accessories. Make: Safex, Bharat or similar. (Inspection of supply portion by Consignee.)

4

5055

20222.64

... More
Supply, installation & fixing of FDMS as per RDSO Spec. No. RDSO/SPN/TC/37/2020 Revision 4.0 or latest. Splicing of 2 nos. of 24 fiber Optic Fibre Cable on the splice trays with provision of taking out 48 fiber of 14 OFC. Pigtail with connector etc. as per TEC Spec. No. G/OFJ-01/03 June 1999 or latest in 10 meter & 5 meter length as detail in specification and as advised by railway engineer as per requirement shall be supply by contactor. The system shall be supply along with standard rack of size 19 inch & 42U with mounting arrangement. (Inspection of supply portion by RITES.)

9

52717

474456.87

... More
Supply, installation & fixing of FDMS as per RDSO Spec. No. RDSO/SPN/TC/37/2020 Revision 4.0 or latest suitable for terminating two nos. of 24 fibre OFC. Splicing of 2 nos. of 24 fiber Optic Fibre Cable on the 15 splice trays with provision of taking out 48 fiber of OFC. Pigtail with connector etc. as per TEC Spec. No. G/OFJ- 01/03 June 1999 or latest in 10 meter & 5 meter length as detail in specification and as advised by railway engineer as per requirement shall be supply by contactor. This includes fixing of FDMS inside rack. (Inspection of supply portion by RITES.)

48

29527

1417343.04

... More
Supply & installation Ring Earth for EI system, consisting of 06 (six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equipotential earth bus bar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth resistance for connecting EI 16 equipments, relay racks, panel , power equipments, IPS as per RDSO TAN no. STS/E/TAN/3006 dated 02.11.2012 or latest. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec. No. RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor. The number of electrodes may be increased if earth value of <1 ohm is not obtained in 6 electrodes. No seperate cost will be given by Railway for this. (for provision of copper strip of size 25mm*2mm in relay room and ips room will be approximately 60 m and for connecting earth electrode with gi strip of size 50mm*6mm will be approximately 40 m). (Inspection by RDSO.)

3

337920

1013761.11

... More
Fabrication, Supply and fixing of Retro reflective Signal Number Plates fabricated as per SEM-II Drawing No. 19-D10 (Sheet No. as applicable). All fixing accessories including clamps, nut, bolts etc. are to be supplied by contractor. (Inspection by Consignee.)

50

780

39032.5

... More
Supply and installation of Earth Electrode as per SEM-II Drawing No. 19-D5. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter deep and fixing earth electrode pipe, casting of cement concrete 18 enclosure with cover (cover as per NER drawing no. S&T/CONST/6.3/97). It includes supply, installation & fixing of 8 SWG wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Earth Electrode to be inspected by RITES.)

150

3616

542532

... More
Fabrication, supply and fixing of MS-C channel of minimum size 10mmx50mmx1200mm with 19 suitable clamps as per drawing No. S&T/RE/78/2/76 and fitting to GI pipes with suitable clamps on girder bridges for sturdy fixing with girders. MS-C channels are to be fabricated as per site requirement. (Inspection by Consignee.)

500

700

350190

... More
Supply, installation & commissioning of active lightening arrester of class-A for building protection- as per standard NFC-17-102 or latest. It shall work on early streamer emission principle and shall be made of stainless steel with an operating time of 60 microsecond or less. A non-resettable type counter shall also be supplied to count the number of lightening occurrences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding. Class-A arrestor should be fixed at least 3 meter above all the metallic structure including VHF antenna. Material shall be procured from RDSO recommended sources & to be supplied along with manufacturer test report. Supply & installation one Maintenance Free Earth as per RDSO Spec. No. RDSO/SPN/197 Ver. 1.0 or latest is also the part of schedule for that no extra cost will be paid. (Inspection by RITES. However, items not covered under RITES will be inspected by consignee)

2

117020

234040.96

... More
Fabrication, Supply and Fixing of Cable Route Marker made with reinforced concrete in the ratio 1:3:6, engraved with "NER-S&T" on the top portion on both the side duly painted. Cable Route Markers are to be made and grouted as per IRSEM Appendix-II Drg. No 15-D1.. (Inspection by Consignee.)

400

449

179876

... More
Supply, installation, wiring, testing & commissioning of Two Wire Talk-Back System (Signal Post Telephone) consisting of one master & one slave of standard make to work in 25KV RE area (operating on 24V/110V) up to distance of 10km on quad cable without any interference/noise. (Inspection by Consignee)

2

7680

15360.66

... More
Supply, fabrication and fixing of retro-reflective marker/boards/plates of 'G' marker and "A' marker as per IRSEM App-II Drg. No. 19-D10 (Sheet No. as applicable). All fixing accessories including clamps, nut, bolts etc. are to be supplied by contractor. (Inspection by Consignee.)

20

930

18609

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per IRSEM Drg. No. 19-D3, using standard size of foundation/galvanized anchor bolts complete, required for erection of 01 colour light signal post. Anchor bolts complete should comply with the IRSEM Drg. No. 19-D3. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor.

40

17947

717906.4

... More
Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like 'A' marker, 'AG' marker, Calling On, shunt signal if any. It includes fixing of all LEDs and wiring 02 of complete signal including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

40

7811

312476

... More
Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1-Way/ 2-Way/ 3- Way/ 4-Way/ 5-Way/ 6- way/ Theater type.

10

1477

14776.7

... More
Excavation, casting, curing of foundation and installation & erection of Apparatus case Full (IRSEM Appendix-II Drawing No.19-D1) with contractor's own frame, anchor bolts & nuts, cement and other material in the 04 ratio 1:3:6 s foundation drawing of Railway. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand, ramming of loose soil around foundation and disposal of loose dugged soil from site. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case.

100

16307

1630779

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thickness, as per Apparatus case diagram/plan, in full size location box (full size apparatus case) by providing all fixtures like 05 ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site.

100

5948

594847

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge. (Supply of all above terminals has been covered separately)

1000

24

24050

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals 07 provided in Apparatus Cases, Cable termination rack in relay room, station building etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, ASM Room etc. under supervision and instructions issued by Engr. incharge of the work.

6000

19

117720

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface of Full size Apparatus Case. Paint to be of reputed make Asian/Delux/Berger or similar. Painting of Apparatus Cases from inside and outside to be done by Silver colour.

100

905

90579

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface of Main Signal post, base, unit and complete fittings of Signal. Paint to be of reputed make Asian/Dulux/Berger or similar.

40

1214

48584.8

... More
Lettering and Numbering of Signals, TLJB, Mushroom housing, Apparatus Cases, Point Machine, Glued/Block Joints etc. (Each item to be taken as one unit). Work is to be carried out as per standard practice.

240

113

27280.8

... More
Lettering and numbering of detail and description writing of particulars of terminations and equipments on relay rack, relays, cable termination rack, battery and power equipments, IPS, operating panel, 11 axle counter, inside location boxes as per location chart etc. constituting entire system with contractor's own paint and writing material (Asian make paint to be used). This includes supply and fixing of Teflon strip 3 mm thick and 25 mm wide for each row of relays and cable termination. This work shall be done as per existing practice of the Railway. Note in unit 1 number = 1 Auto Hut

2

12526

25052.98

... More
Installation, testing and commissioning of Micro Processor based Data Logger System with 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay 12 rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, MSDAC, interfacing with EI and interlinking & networking of Data logger. It also includes installation of MODEM and other interfacing cards, if required for networking of Data Logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.

2

87663

175326.8

... More
Horizontal Boring/Manual moling without damage to surface road/track for laying/insertion of DWC/GI/HDPE pipe.The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground 13 level shall be considered ignoring the bank height of the bank of the road/track. Contractor shall provide all materials required for work and adequate no. of labours for proper laying of cables into the bore. Cables shall be laid cautiously so that these should not get damage due to rough handling and pressure on cable. Payment of boring shall be made only after laying of DWC/HDPE/GI pipe in the bore.(Note:- DWC/HDPE/GI Pipe supply is not covered under this item.)(Laying of cable in bore will be paid under item cable laying).

5000

1438

7194300

... More
Horizontal direction drilling (HDD)/ Trenchless digging/ machine drilling without damage to surface road/ track without laying/insertion of HDPE pipe along with the coupler required. The bore width should be of 120 14 mm and shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road/ track. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the duct. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. (Laying of cable in bore will be paid under item cable laying)

55000

797

43874600

... More
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes 15 supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.

2000

470

941200

... More
Excavation of cable Trench of 120 cms depth and 30 cms wide in all kinds of soil within station limit 16 & block section both for main and tail cables as per cable route chart to be given by engineer at site and its refilling with the same excavated soft soil. Note:- Depth of the cable duct to be measured from the hard soil level of the ground.Width may be increase if required to accomodate duct without any extra cost.

10000

44

445800

... More
Cutting of all types of platforms/ road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per 17 original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of atleast 5cm thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

500

211

105515

... More
Installation of Thermo shrink jointing kit as per RDSO specn No. IRS: TC 77-2012 (Rev 3.0) with (Amdt-1 to 3) or latest suitable for 6 quad /jelly filled cables for straight through/derivation joints from OEM trained staff as per procedure specified by RDSO and standard practices of Railway including excavation of pit for joint.

50

1692

84603

... More
Breaking and repair of RCC concrete in Relay Room/ Panel Room at station for drawing various sizes of cables.

6

6668

40013.58

... More
Laying of HDPE duct as per the approved cable route plan in the excavated trenches/ other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. The ends 20 of the duct to be sealed with end plugs till OFC blowing is done. Note: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter-XIII of the Telecomm Manual.

80

8656

692533.6

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already provided in the 21 trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

80

12297

983820.8

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in the ratio 1:3 22 including excavation of pit for joint enclosure. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor.

20

8311

166232.4

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own machine and 23 tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.

50

15954

797720.5

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes 24 etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and contractor shall submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

350

9085

3179792

... More
Testing and commissioning of outdoor Automatic block signalling installation with MACLS system as a whole by contractor under supervision of the engineer incharge of the work under traffic block. Required nos. of skilled & artisan staff and labours required for testing and commissioning of the system within given traffic block 25 shall be provided by contractor. All types of testing equipment such as simulation panel for auto relay huts & stations for testing of track circuits, signals, points, slots etc, various types of measuring instruments like voltmeter, ammeter, megger, tools etc. shall be provided by the contractor at his own cost. Testing shall be carried out to ensure compliance of SEM, G&SR, block working manual and adherence to technical specifications & scope of work mentioned in tender document. Note- 1 number= 1 auto section

5

100848

504243.9

... More
Training of Sr. Engineers/ Engineers/ Technicians/Jr. Engineers regarding installation, testing, commissioning maintenance, repairing and troubleshooting of EI, MSDAC and other equipments. (Hard and Soft Copies of Training Material/Course Modules on each subject shall given to Each Participant).

40

4366

174646.4

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the site incharge of work of Railway. The rate includes all tax, license fee, road permit, driver wages, fuel, repair and maintenance cost etc.

5000

72

362950

... More
Transportation of less heavy material and man power, supply and running of 1 MUV to the sites of work as per requirement and direction of engineer incharge of work along with driver. The rate includes all tax, license fee, road permit, driver wages, fuel, repair and maintenance cost etc.

5000

46

232250

... More
Fixing of Q series relay base plate & relay, laying, bunching, lacing & dressing PVC indoor cable/ 29 flexible wire and termination of cable/flexible wire on tag block/ base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work in connection with circuit alterations at PI stations. The work shall be done as per approved plan, extant practice on NER & the instruction of Rly. Engineer at site.

500

518

259250

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, coarse, sand 30 and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate, cement and sand will be supplied by contractor.

100

6786

678677

... More
Supply of Resin core 60/40, 18 SWG (Philco/Khosla or similar reputed make)

2

1853

3707.34

... More
Dismantling and releasing of existing Location boxes/Apparatus cases/Jn boxes and all other associated fittings. All the released material will be transported to the SSE/Consignee depot.

10

1291

12911.5

... More
Dismantling and releasing of existing Signals and all other associated fittings. All the released material will be transported to the SSE/Consignee depot.

10

2031

20318

... More
Final location survey of cable route and final preparation of route plan as per code of practice for installation & commissioning of optic fiber & Quad cable system (STT/FO/1 issued by RDSO, Lucknow) including 34 supply of final cable route plan giving all necessary details as per following. (i). Two sets initially for approval and commencement of work on A3 size paper. (ii). One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii). One set of original tracings. (iv). Five sets of final 'As Made' completion plans/diagrams on white bond paper of A3 size in proper bounded form.

20

1204

24083.8

... More
(a). Design, preparation and supply of the following Technical documents: (i). Installation, Testing, Commissioning and Maintenance manuals. (ii). Functioning and System overview manuals. (b). Design, preparation and supply of the following the following completion documents: (i). Application Logic circuits. (ii). VDU/CCIP diagram. (iii). Interface Circuit/Wiring diagrams consisting of Relay contact analysis chart, Relay disposition chart, Relay contact to contact wire list chart, VDU/CCIP cable termination chart, Power supply diagram, Electronic signalling equipment and Power supply layout diagram, Relay rack and Cable termination rack layout diagram, Relay rack and Cable termination rack particulars, Fuse, Resistors, Condensers etc. particulars, 35 Details of Analog and digital inputs to be supplied to Data logger, Wiring diagrams for SSDAC/ HASSDAC/MSDAC etc. (iv). Cable Route plan with overlaid Location Boxes placement as per standard practices of NER. (v). Cable Core plan with overlaid Location box placement. (vi). Location huts/Gate Lodge wiring diagrams. (vii). Location boxes wiring diagrams. (viii). Track circuit bonding plan. (ix). Earthing particulars plan. (x). Station working rule diagram (SWRD). (xi). Station working rule (SWR). (xii). Selection table/ Route control chart. Note: All the above completion documents should be supplied as follows: (i). Two sets initially for approval and commencement of work. (ii). One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii). One set of original tracings. (iv). Six sets of final 'As Made' completion plans/diagrams in proper bounded form. Note:- Station includes there concerned autohut and Connected Level crossing gate.

7

235437

1648060.89

... More
LAYING OF DWC PIPE (upto 120 MM) WITH SOCKET COUPLER IN TRENCHES AS PER DIRECTION OF SITE ENGINEER.

500

7

3615

... More
LAYING OF DWC PIPE (200 MM) WITH SOCKET COUPLER IN TRENCHES AS PER DIRECTION OF SITE ENGINEER.

500

20

10470



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.