North Central Railway Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

North Central Railway - NCR Tender

Works
Civil And Construction
Telecommunication Services
Water Storage And Supply
Ireps
Opening Date14 Feb 2025
Closing Date10 Mar 2025
Tender Amount₹ 2,19,92,689.19 
Notes
Download

AI Insights

Bid Capacity
... View More
The bid capacity required to bid in the given tender is calculated using the formula: V/N or 'V' whichever is less, where V = Advertised value of the tender in crores of Rupees and N = Number of years prescribed for completion of work for which bids have been invited. Given that the advertised value of the tender is 21992689.19 and the period of completion is 12 months (approximately 1 year), the calculation is as follows: V = 21992689.19 / 10000000 = 21.99 (in crores of Rupees) and N = 1 year. Therefore, the minimum average annual contractual turnover required is V/N = 21.99 / 1 = 21.99 or V = 21.99, whichever is less. Since 21.99 is equal to 21.99, the minimum average annual contractual turnover required is 21.99. Additionally, the tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during the last 07 years: (i) Three similar works each costing not less than 6597806.757, (ii) Two similar works each costing not less than 8797063.672, (iii) One similar work costing not less than 13195613.514.
Technical Capacity
... View More
The required prior work experience for the bidder includes successfully completing or substantially completing specific categories of work(s) during the last 7 years. These categories include: (i) Three similar works each costing not less than 30% of the advertised value of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of the tender, or (iii) One similar work costing not less than 60% of the advertised value of the tender. In the case of composite works, the tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during the last 7 years: (i) Three similar works each costing not less than 30% of the advertised value of each component of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of each component of the tender, or (iii) One similar work each costing not less than 60% of the advertised value of each component of the tender. For subcontractors, they must have successfully completed at least one work similar to the work proposed for subcontract, costing not less than 35% of the value of the work to be subletted, in the last 5 years. However, for subletting work costing up to Rs 50 lakh, no previous work experience of the subcontractor is required. The bidder is required to furnish a list of works completed in the last seven financial years, giving details such as description of work, organization for whom executed, approximate value of contract at the time of award, date of award, and date of scheduled completion of work. Additionally, the bidder must provide the date of actual start, actual completion, and final value of contract. The bidder must also provide a list of works on hand, indicating description of work, contract value, approximate value of balance work yet to be done, and date of award. The definition of similar work is the execution of any Signaling work. The required percentages of similar works completed are 30%, 40%, and 60% of the advertised value of the tender, and the required amounts are not less than these percentages of the advertised value. For subcontractors, the required percentage is 35% of the value of the work to be subletted.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Position Light Shunt Signal Unit Complete, Metallic/FRP, Independent type, along with base and post, hood, Cover etc as per Drg. No. SA-23840 (or Advance) suit able for LED Signal Lighting Unit. (Inspection Agency:- Consignee).

7

4080

28565.18

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection Agency:- Consignee).

19

5371

102065.15

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of 7 one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Inspection Agency:- Consignee).

11

26948

296431.63

... More
Supply of Rx Track Device of G.G. Tronics Make SSDAC as per RDSO Specn. No. RDSO/SPN/177/2012 (Version 3) or latest having length of cable 15 Mtr.(Inspection Agency:-RDSO).

40

27286

1091478.4

... More
Supply of Tx Track Device of G.G. Tronics Make SSDAC as per RDSO Specn. No. RDSO/SPN/177/2012(Version 3)or latest having length of cable 15 Mtr. (Inspection Agency:-RDSO).

11

27286

300156.56

... More
Supply of Axle Detector (AD-711 FS) each set consists of Clamp Type 02 No. of TX coil 10 and 02 Nos. of RX coil including Mounting accessories for 60 Kg Rail with 15 Mtr Cable length for CEL Make SSDAC/HASSDAC systems as per RDSO Spec. No. RDSO/SPN/177/2012 Ver. 03 or latest. (Inspection Agency:-RDSO).

26

88500

2301000

... More
Supply of Axle Detector (AD-711 FS) each set consists of Clamp Type 02 No. of TX coil and 02 Nos. of RX coil including Mounting accessories for 52 Kg Rail with 15 Mtr Cable length for CEL Make SSDAC/HASSDAC systems as per RDSO Spec. No. RDSO/SPN/177/2012 Ver. 03 or latest. (Inspection Agency:-RDSO).

-

-

11

... More
Supply of Wheel sensor RSR 180 -001 GSO05 Ver 23320 or latest for rail claw mounting with 5 mtr of cable (frauscher make) Inspection . (Inspection Agency:-RDSO).

5

95477

477389.35

... More
Supply of Protection tube flame resistant 4.8 m for wheel sensor cable protection or latest Inspection . (Inspection Agency:- Consignee).

5

4834

24174.9

... More
Supply of Rail claw SK 140 for rail mounting vertically adjustable excl. clamping bolt pair or latest .(Inspection Agency:- Consignee). 15

5

37394

186973.8

... More
Supply of clamping bolt for rail claw SK 140 or latest. (Inspection Agency:- Consignee).

5

4241

21208.65

... More
Supply of TX and RX coil/detection sensor for Siemens make MSDAC as per spec. RDSO / SPN / 176 / 2013 ver- 3.0 or latest . (Inspection Agency:- RDSO).

7

172198

1205387.82

... More
Supply of Off set brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No. SA-23080/Adv. along with fixing U bolts, nuts and clamps.(Inspection Agency:- Consignee).

4

1898

7594.96

... More
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No. RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consist of following: (a) Copper bonded steel electrode of minimum 3.0 meter long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 No. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 Nos. (c) Copper strip of 150x25x6 mm, to 18 terminate earth rod = 1 No.(d) Copper strip of 300x25x6 mm (MEEB) = 1 No. (e) Copper strip of 150x25x6mm (SEEB) = 1 No. |Gi) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter.) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter. ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable. (Inspection Agency:- Consignee).

16

17575

281211.04

... More
Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or 19 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Inspection Agency:- Consignee).

10

19017

190178.8

... More
Supply of Disconnect Terminal block for Four conductor with screwless Cage Clamp 20 type/sliding switch disconnect as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest for each conductor size upto 2.5 sq. mm. Equivalent of M6 Terminals. Each Terminal block equipped with two markers on top and bottom, an end plate, 2 end clamps & adequate length rails for fitting terminal blocks. (Inspection Agency:-RDSO).

2700

180

488565

... More
Supply of Track Lead Junction Box (TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. Th e FRP material shall be as per RDSO spec.No. RDSO/SPN/151/1997 or latest. Th e technical specifications are as follows: (a) TLJB complete with cover to be in black/red/grey with all the 21 holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two Bakelite terminal block fitted horizontally, each Bakelite terminal block shall have two nickel chrome plate with brass terminal. Along with each TLJB, nickel chrome plated brass links(two nos. of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe along with two nuts for fixing on the TLJB hole. (d) Th e FRP stump for mounting the TLJB. (Inspection Agency:- Consignee).

67

5339

357767.94

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20- 21, 9151-52,9000- 01,03-04,9065- 66,9101, as applicable. (Inspection Agency:- Consignee).

6

14771

88626.48

... More
Supply and installation of earth electrode as per standard practice and as per NCR practice It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the 23 equipments which are required to be earthed including digging of earth pit 3 mtr deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection Agency:- Consignee).

31

3287

101901.34

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and Non flame propagating type in 6 meter straight length and of size 120 mm outer dia, & 103.5 mm inner dia. (Th 24 e manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.(Inspection Agency:- Consignee).

240

635

152412

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. (Inspection Agency:- RDSO).

4

3137

12549.88

... More
Supply of 24 fiber optical fiber cable straight joint enclosure (SIC) complete with all 26 accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec. RDSO/SPN/TC68/2014 Revision 1.0, Amndt. 1.0 or latest. Splice losses in no case should be more than 0.1 dB. (Inspection Agency:- Consignee).

4

5139

20556.32

... More
Supply of Position Light Shunt Signal Unit Complete, Non-Metallic, made of FRP as per Drg. No. SA-23840 (Adv.) or latest, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). (Inspection Agency:- Consignee).

2

17090

34180.88

... More
Supply of Electrically Operated Lifting Barrier complete set suitable for 110 VDC / 24V DC supply, without hand generator back up, and motorized boom locking arrangements as per RDSO Spec.No. SPN/208/2012 Ver. 2.0 or latest. The 02 Nos of Barriers of length 09.76 meter should be supplied along with stop boards and light. Th e spares & tool kit mentioned in RDSO Spec. No. RDSO/ 28 SPN/208/2012 Ver. 2.0 and Amndt. 1 or latest, clause 10.1 & 10.2 reproduced as below should be supplied along with each full set :- i) GI boom - 1 No. complete. ii) Belt - 1 No. iii) Crank handle - 1 No. iv) Motor Contactor - 1 No. v) Motor protection MCB- 1 No. vi) Push button complete- 2 Nos. vii) Limit switch - 3 Nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 Nos.) of Electric Lift ing barrier. (Inspection Agency:- Consignee).

1

362897

362897.65

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. (Inspection Agency:- Consignee).

1

76136

76136.54

... More
Supply, fabrication and fixing of the Calling On board/BSLB board as per NCR Typical 30 drawing in Technical circular no 01/24 dt :- 08.02.2024 or as per consignee, on concrete foundation and painting with Retro reflective paint. All work to be carried out as per Railway site engineer instructions. (Inspection Agency:- Consignee).

1

8112

8112.48

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 1 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.

292

1010

295197.4

... More
Wiring in relay room/ location box fixing of Q series relay base plate/ metal to metal relay mini group and major group base plates, laying lacing dressing & packeting of 60/40 core PVC indoor cable/ flexible wire and termination of 60/40 core cable/ flexible wire on tag block/ base plate & soldiering. wiring of circuits to be done as per rly.site engineer] on relay interlocking system using 2 metal to metal / metal to carbon type relay and soldering after testing. This also includes fuse wiring, function wiring ( interconnection between relay rack & 0.6mm , 1.0mm RDSO spec. no IS 694/1990, S :76/89 or latest and should be procured form RDSO approval sources and 16/0.02 multi strand flexible etc.resin core, solder wire , lacing thread adhesive tapes , resistance, condensers, diodes, lugs etc of various ratings and capacity as per site requirement will be supplied by the contractor free of cost and will be sued after approval of Rly engineer at site. The jumper wire required for carrying out the indoor work shall be supplied by contractors wire should be assessed jointly with the engineer in charge at the beginning itself. The work shall be done as per approved plan extant practice on N C rly & the instruction of Rly engineer at site unit per tag block / number).

104

999

103931.36

... More
Fixing, wiring, testing and commissioning of Electrical Point Machine 220MM/143MM on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes: (i)Complete material for installation like ground- connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers. (ii) All smithy & fitting works required at site for complete 3 installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes /location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded frame for cable entry to machine (vi) Supply and filling of industrial grade/good quality lubricant/grease/oil for smooth operation of point machine Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer- in-charge and shall be." "Suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately.

8

13189

105518.8

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect 4 terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full).

15

4265

63988.05

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect 5 terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half)

10

2320

23200

... More
Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg. No. NR/S&T/Const/2.2/97 using standard size of foundation/gal- vanized anchor bolts complete, 6 required for erection of shunt signal post. An- chor bolts complete should comply with the RDSO drg. No. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor.

7

3670

25692.31

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.

7

951

6660.36

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 8 concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

710

148

105264.6

... More
Cross trench for identification of the route of existing signaling and telecomm cables.

40

276

11064.4

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.

100

83

8382

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/ Berger or similar. (Shunt Signal post, base, unit and complete fittings)

8

389

3119.6

... More
Digging of 01 Meter deep and 300MM wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per cable route plan. Note:In case where digging of trench up to 01 Meter depth and 300MM wide is not possible or bigger size trench is 12 required to lay more cables or loose soil/ muck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 01 Meter deep and 3 MM wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil. In all type of soils including soft rock.

10500

49

517965

... More
Digging of 01 Meter deep and 300MM wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per cable route plan. Note:In case where digging of trench up to 01 Meter depth and 300MM wide is not possible or bigger size trench is 13 required to lay more cables or loose soil/ muck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 01 Meter deep and 3 MM wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil. In rocky soils.

1890

71

134643.6

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, 14 generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work.

3700

13

50949

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 15 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

42500

4

205275

... More
Laying of Double Wall Corrugated (DWC) pipe of all sizes with socket, coupler and T 16 Joint etc. by digging of trench 0.3 Meter width, 1.2 Meter depth from rail flange under track for track crossing and refilling after laying of pipes, the restoration of disturbed ballast by screening and dressing as per instruction of Engineer in- charge or his representatives at site.

640

82

52729.6

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. App. Cases inside and outside to be done by Silver color. (Apparatus Case Full)

13

636

8273.46

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half)

10

592

5922.8

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Main/shunt Signal post, base, unit and complete fittings).

5

914

4572.3

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er 20 scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Point machine and ground connections, Point machine by Black enamel and ground connection by Red oxide).

5

288

1442.55

... More
Modification to existing panel interlocked MACLS station for interconnection wiring withladder arrangement where ever required for control panel,relay room equipment & power supply equipment,battery room,ASM room,outdoor equipment,termination in relay room,equipment terminals,CT rack and rack to rack wiring etc.based on approved signalling plans and circuit diagrams.

4

72920

291680.6

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 22 case Full as per NCR practice with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

15

11458

171871.95

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 23 case Half as per NCR practice with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

10

9867

98674

... More
Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no, 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1,5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments, Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness 24 of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip-potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip- potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mmx 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn. No. RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specifi cation document are : (i) SDO/RDSO/ E&B/001 for typical installation of Earth, (ii) SDO/RDSO/E&B/002 for typical bondong and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements. OEM certification required.

16

7276

116431.84

... More
Preparation & submission of cable route plan of main & tail cables , cable cordage plan, location particulars, CT rack particulars, meggering report , earth resistance particulars, traction bonding diagram and any other drawing / particulars required in auto CAD in minimum A3 size each 25 sheet should have a block for signature of Railway officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firms. The name of the work as given by the Railway shall be written on every sheet under the work column. One compete set of tracings and four sets of copies of complete above detailed particulars / drawing along with one CD to be supplied by the contractor in thick plastic folders.

6

30431

182586.72

... More
Modification/Alteration in existing EI (Electronic Interlocking)at RAGAUL & PATARA Station as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data 26 Logger, Relay rack wiring. Th e complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied Alteration involving modification in up to 10 routes.

2

3277713

3277713.5

... More
Development and preparation of SIP, SWRD/GWRD/SWR etc based on existing SIP/ESP .(For station/LC upto 4 lines) Job=Per Stn/LC

6

22551

135311.76

... More
Drawing of wiring circuit in A-3 size sheet in autocad.(02 sets photo copy & 01 set tracing with soft copy) .

84

658

55332.48

... More
Cable insertion in Old locations /Station Relay room /cable pit etc as per site engineer and filling with sand and plastering the same. Note: All the sundry material except that to be supplied by railways will be supplied by the contractor.

13

1961

25496.25

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77- 2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly fi lled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer.

4

1570

6282.04

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 31 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge. (Supply of all above terminals has been covered separately).

500

17

8620

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways.

40

55

2200.8

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 33 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

1

16055

16055.48

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete 34 with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc.

1

55688

55688.62

... More
Dismantling and Releasing of existing Electrically operated LC gate/Mechani cally operated LC gate and other associated S&T fittings. All the released mate rial will be transported to the SSE/Consignee depot.

1

8782

8782.7

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 36 the ratio 1:3. Th e thickness of the wall shall be 120 mm. Th e top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. Th e pit shall be covered with sand aft er putting the joint enclosure. All construction material to be supplied by contractor.

4

5960

23842.36

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.

20

84

1696.2

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own 38 machine and tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.I

4

11209

44839.32

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, 39 coarse, sand and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.

20

4867

97341.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.