Noida Metro Rail Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Noida Metro Rail Corporation Limited - NMRC Tender
Eprocure
Opening Date30 Aug 2018
Closing Date13 Sep 2018
Tender Amount₹ 60,84,362
Costs
EMD
₹ 1,30,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_NMRCL_244994_1Bid Award Id
ViewTender No
25/NMRC/JGM(C)/2018Tender Authority
Noida Metro Rail Corporation Limited ViewPurchaser Address
-Website
http://http://www.nmrcnoida.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
-
-
-
Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ AC supply, for the above pump with synchronous speed of 1450/2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required.
-
-
-
Common base plate for (a) and (b) from M.S. Channel for required size.
-
-
-
Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with anti-vibration arrangement of cushy foot mountings.
-
-
-
The rate includes interconnecting cables, foundations & foundation bolts
1
-
438900
Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.
-
-
-
Horizontal split casing centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (304) Shaft with mechanical seal, capable for delivering 2280 lpm at outlet head of 70 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority).
-
-
-
Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
-
-
-
Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required.
-
-
-
Common base plate for (a) and (b) from M.S. channel of required size.
-
-
-
Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with antivibration arrangement of cushy foot mountings.
-
-
-
The rate includes interconnecting cables, foundations & foundation bolts
1
-
694925
Supply, installation, testing and commissioning of jockey pump (pressurisation pump) comprising of the following:
-
-
-
Vertical centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete as required.
-
-
-
The pump casing shall be CI, shaft shall be SS & impeller/ shaft sleeve/casing wearing ring shall be bronze. The pump shall be provided with mechanical seal The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should meet the condition and shall be gotten approved by the Local fire Authority).
-
-
-
Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 RPM with flexible coupling and coupling guard etc. as required.
-
-
-
Common base plate for (a) and (b) from M.S. channel as required size.
-
-
-
Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting.
-
-
-
For pump defined above & of duty as follows :
-
-
-
Flow : 180 LPM
-
-
-
Head : 70 mts
1
-
76076
Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope.
50
-
8778
Providing, fixing, testing andcommissioning of precharged air vessel (size 450 mm dia & 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required.
1
-
26334
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968. (The cushion tank should be suitable for rated working pressure.
7
-
9070.6
Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
9
-
965.58
SUBHEAD: II: Hydrants, Sprinkler,Piping & Accessories
-
-
-
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all victaulic fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/slabs and making good the same etc. complete in all respect as required.
-
-
-
200 mm dia (6mm thick)
40
-
3584.56
150 mm dia
375
-
2460.4
100 mm dia
95
-
1777.18
80 mm dia
120
-
1305.12
65 mm dia
95
-
1140.27
50 mm dia
65
-
946.72
40 mm dia
70
-
756.78
32 mm dia
65
-
696.06
25 mm dia
750
-
611.43
Providing and fixing forged brass ball valve with forged brass ball (suitable for test pressure of not less than 15 kg / sq.cm of the following size :
-
-
-
(Cost shall be inclusive of providing necessary union / flange connection).
-
-
-
25 mm dia
6
-
1191.45
50 mm dia
6
-
3602.5
Providing & fixing of butterfly valve (suitable for test pressure of 15 kg / sqm) with flanges, nut bolts, gaskets and necessary pad locking arrangement complete required.
-
-
-
80 mm dia
7
-
3657.5
100 mm dia
6
-
4672.25
150 mm dia
20
-
7040
200 mm dia
2
-
16988.61
Providing and fixing of C.I. wafer type check valve with flanges, Nut, bolts & washers, painting etc. complete as required.
-
-
-
80 mm dia
6
-
6092.9
150 mm dia
5
-
10367.03
Providing & fixing of CI/Bronze body gate valves with high tensile brass rising stem suitable for the system pressure.
-
-
-
25 mm dia
5
-
2575.1
Providing, fixing and commissioning of spring loaded relief valve suitable for pressure of 15 Kg / sq.cm including flanges, nuts, bolts, washers etc. complete as required.
-
-
-
80 mm dia
6
-
13417.03
Providing & fixing double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required.
-
-
-
150 mm dia
6
-
13915
80 mm dia
4
-
11885.5
Providing and fixing C.I.`Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.
-
-
-
150 mm dia
3
-
16371.64
80 mm dia
2
-
6171.37
Supplying and fixing Single Headed Internal Hydrant Valve oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS : 5290 (Type A), with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required.
6
-
5391.16
Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia globe valve stop cock, terminating with G.M. coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:884-1969 complete as required.
6
-
7753.9
Providing & fixing non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) of 63 mm dia and length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked S.S male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire (Location : Internal fire hydrant)
-
-
-
15 m length
12
-
5852
Providing and Fixing 63 mm dia instantaneous pattern branch short Stainless Steel pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
6
-
3057.67
Providing and fixing standard fire man's axe with heavy rubber handle.
6
-
694.93
Providing & fixing gun-metal fire brigade inlet connection consisting of 2 Nos. 63 mm dia instantaneous type male couplings with built-in check valves, 1 No. 100 mm dia sluice valve complete with bolts, nuts and rubber insertions as required and as per IS:904-1963.
1
-
4974.2
Providing and fixing 5 mm thick glass door (with M.S. frame) of size 2.1 m x 1.2 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters "FIRE HOSE" including locking arrangement. All M.S. work to be in Red P.O. colour over appropriate primer. The above item is only for masonary fire station.
6
-
11850.3
Providing and fixing heavy class MS suction & delivery headers of required length conforming to IS:3589 with welded joints standard MS Fittings and with end flange connections having inlet & outlet flanged connections including GI supports from wall, floors & ceiling complete as required. Cost should be inclusive of all supports / clamps /two coats of synthetic enamel pain/ brackets, anchor fastner etc. as required (all in GI).
-
-
-
200 mm dia
10
-
3218.6
150 mm dia
10
-
1755.6
Providing and fixing flexible connectors consisting of flexible core 1.5 mtr. in lenghth of corrugated stainless steel tubing under the braid, (Braiding to be SS-304, tubing to be SS-304) for minimum working pressure rating of 200 PSI to be installed at connections from branch pipes to pendant sprinklers blow false ceiling as per specification of the manufacturers.
170
-
1121.25
Supplying and fixing vane type water flow switch suitable for installation on 50 mm to 150 mm dia line for a service pressure upto 20 kg/sq. cm. of Potter / System sensor /Angus
4
-
6951.75
Supplying, Installation, Testing and Commissioning of Sprinkler installation valve with water gong, pressure gauge, drain valve etc as required 200 mm dia size etc. complete as required.
1
-
88952.5
Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature.
-
-
-
Pendant Type,68° C, Chrome plated
170
-
299
Side wall type, 68° C, Chrome plated
76
-
485.88
SUBHEAD: III: Portable Chemical Fire Extinguishers
-
-
-
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner).
-
-
-
ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets
12
-
4389
ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
12
-
7461.3
ISI marked (IS:2171) Portable Dry Chemical Power Type Fire Extinguisher with Gun Metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket
-
-
-
5 Kg
6
-
4023.25
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
2
-
4389
Sub Head - IV (Motor Control Panels)
-
-
-
Fabrication, Supplying, Installation, Testing & Commissioning of Electrical Fire Motor Control Panel of cubical construction, floor mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with solid aluminium strip / single core PVC insulated FRLS copper conductor cable, having suitable mountings for switchgears and accessories and internal control & power wiring with suitable rating PVC insulated FRLS copper conductor, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42 with 600 Amp aluminium bus bar etc complete as required.
-
-
-
Incoming
-
-
-
MCCB, 4 Pole, 630 A, 50 KA with adjustable thermal magnetic release and rotary handle (ICS= ICU= 50 KA upto 415 V) - 2 sets.
-
-
-
Digital Ammeter (0 - 600 A), 96 mm. sq. CT operated with inbuilt selector switch with 3 Nos. CT's of ratio 600/5 A, 15 VA burden and accuracy of class 1.0 - 2 Sets
-
-
-
Digital Volt Meter (0-500 V) 96 mm. sq. with inbuilt selector switch and control MCBs - 2 Sets
-
-
-
Phase Indicating coloured LED (RYB) with control MCBs - 2 Sets
-
-
-
Bus Bar :
-
-
-
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 415V, 600 amps, 50Hz, AC, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
-
-
-
Outgoing for Main Fire Pump
-
-
-
MCCB 3 Pole, 400 A (with adjustable thermal magnetic release and (Ics=Icu=25 KA upto 415 V), with CT operated digital Ammeter (0 - 400 A), with 3 CT's of 400/5 A, 10 VA, accuracy 1.0, ASS and coloured LED for on (Red) indication - 3Set (2 W + 1 Spare)
-
-
-
Fully Automatic Star Delta Starter suitable for sprinkler Pump motor of minimum 65-75 KW and (as per the recommendation of pump manufacturer) complete with over load protection, current sensing type single phase preventer complete with contactors, push button, indicators LED type Auto/manual selector switches all accessories and FRLS copper conductor wiring etc. as required - 2 Set
-
-
-
Outgoing for Pressurization Pump(Jockey)
-
-
-
MCCB 3 Pole, 63 A, 25 KA with CT operated digital Ammeter (0 - 60 A), with 3 CT's of 60/5 A, 10 VA, accuracy 1.0, ASS and coloured LED for on (Red) indication with adjustable thermal magnetic release and (ICS = 25 KA upto 433 V) - 2 Set
-
-
-
Fully Automatic Star Delta Starter suitable for Jockey Pump (Minimum 15 HP capacity) complete with over load protection, current sensing type single phase preventer complete with contactors, push button, indicators LED type Auto/manual selector switch all accessories and wiring etc. as required - 1 Set
-
-
-
MCB 4 Pole, 63 A, 10 KA 'C' - 1 Set
-
-
-
MCB Double Pole, 16 A, 10 KA 'C' - 3 sets.
-
-
-
Diesel Engine Control
-
-
-
Auto / Manual selector switch and 3 attempt Starting device, Electronic timer, Relays, Auxiliary switches, Rotary switches, Tripping relays, Contactors, Push button for manual Start / Stop etc. to make the equipment automatic as per functional requirement.
-
-
-
Battery charging unit suitable for 24 V DC with boost and trickle charger, selector switch, with suitable rating transformer, rectifier, RC filter network, fuses on AC and DC protection, 0 - 30 V DC Digital Volt meter, 0 - 20 A DC Digital Ammeter, the charger should be cut off when the engine is started and the batteries shall be charged from battery charging alternator provided in the engine.
-
-
-
Suitable rating & type standard relays, contactors and other accessories for automatic operation of diesel engine
-
-
-
Indication LED's for high / low lub, oil pressure, water temperature, engine on indicator, with suitable alarms, acknowledgement button etc.
-
-
-
System Controller
-
-
-
Designing, Supply, Installation, Testing and Commissioning of system controller to control operation of Main Electric Fire Pumps, Diesel Engine Pump, Jockey Pumps, Terrace Pump in sequence as per specification consisting of relays, timers, sensors, annunciation window for fault indication, complete as per specification.
-
-
-
First Jockey pump will start than hydrant and sprinkler pump start, in case of failure of power diesel pump will start.
-
-
-
Colour coded internal wiring and connections etc. with suitable size Fire Retardant Low Smoke PVC insulated copper cable / solid aluminium strip / bus bar from incoming to bus bar and from bus bar to switch gears / MCCB, starters, meters, selector switches, indicating LED's, interlocking and sequence operation arrangements.
-
-
-
Terminal facility for repeat indicator of various audio and visual indications.
-
-
-
First Jockey pump will start than hydrant and sprinkler pump start, in case of failure of power diesel pump will start.
-
-
-
Colour coded internal wiring and connections etc. with suitable size Fire Retardant Low Smoke PVC insulated copper cable / solid aluminium strip / bus bar from incoming to bus bar and from bus bar to switch gears / MCCB, starters, meters, selector switches, indicating LED's, interlocking and sequence operation arrangements.
-
-
-
Terminal facility for repeat indicator of various audio and visual indications.
-
-
-
Fire panel as above
1
-
719796
Labour Cess
1
-
6084362.52
Evaluation Notes How It Works ?