Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jan 2024
Closing Date7 Feb 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out defective microprocessor control board from the AC Plant unit 21 / 22.5 TR and repair it with complete rewiring of AC panel including connector wire MCB etc connecetd items as per site required by authorised service enginner or from manufacture service centre and fixing the same with connection complete with satisfactory working all as required and directed by Engineer in charge.

4

-

-

... More
S&F in replacementof liquid line filter (Drier)of suitable size and suitable for 4x 21TR Cap AC plant complete all as specified and directed.

4

-

-

... More
S&F in replacementof pressure release valve (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.

4

-

-

... More
S&F in replacement of air release valve fitted in water chiller line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.

4

-

-

... More
S&F in replacement of H.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.

4

-

-

... More
S&F in replacement of L.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.

4

-

-

... More
S&F in replacement of 3 pole ,415 volt 50 Hz, 40 Amp contactor,of coil voltage 230 volt complete all as specified and directed.Make - Siemence or as approved by Engr-in -charge

4

-

-

... More
S&F in replacement of worn out /unserviceable copper tubing from chiller to safety kit including making proper connection complete all as specified and directed.

4

-

-

... More
S&F in replacement of clothing curtain fitted between AHU and main duct complete all as specified and directed.

4

-

-

... More
S&F in replacement of worn out connector plate backelite, 440 volt, 145 amp suitable for 16 to 50 sq mm cable complete all as specified and directed.

10

-

-

... More
S&F in replacement digital panel mounted AC Volt meter ( 0 to 500/600 Volt) , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .

4

-

-

... More
Disconnecting the electric connection from starter and motor including taking out of electric motor of capacity 2 HP from the existing position and strip opening, cutting the burnt out winding, cleaning the starter and re-winding the same with super enameled copper winding wire of same gauge using top class of insulating material & reassembling the same and re-fixing back in its original position complete all as specified and directed.

2

-

-

... More
Taking out pump of 2 HP capacity and re-fixing the same in its original position after over hauling including lath/ machine work for making housing of bearing , metaling ,welding, turing surfacing ,polishing of rotor shaft, and replacement of neck ring , bearing of required size , bushes, rubber insertion sheet , nuts, bolts and washers including necessary other items for its smooth functioning and testing complete all as specified and directed.

2

-

-

... More
S&F in replacement digital panel mounted AC Amp meter ( 0 to 450 amp) , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .

5

-

-

... More
S&F in replacement of worn out /unserviceable pressure gauge 100 mm dia of suitable range with all necessary tubing etc to make serviceable condition fitted in water chiller line complete all as specified.

4

-

-

... More
Cleaning of cooling coil and air filter of Air Handling Units installed at air conditioning plant by removing air filters and fixing back after cleaning with air blower, water and cleaning agent, cleaning of cooling coil with wire brush and air blower and water spray pump after spraying scal Gun AL or equivalent chemical suitable for aluminium fins and straightening the fins of cooling coil using suitable brush cleaning of bottom tray, drain pipe complete one coat of painting with sinthetic enamal paint after rubbing of existing surface and applying one coat of primer inside and outside complete all as directed

2

-

-

... More
Repair/Replacement of MCB, 63 Amp, four pole and breaking capacitry 10 KA complete as directed.

4

-

-

... More
Material and labour, rewinding of Exhaust fan three phase induction motor 1.5 KW/ 2HP 415 volt 940 rpm of any make of with suitable gauge of super enameled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearings, two coats of synthetic enamel spray painting, suitable main connections from coil to terminal box, opening of motor, cutting/removing old burnt winding coils, cleaning/filing the starter slots, necessary mechinical works for shaft/bearing housing, preparing and inserting coils running/starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and fro transportation, testing at site,replacing new connection terminal plate of following sizes satisfactorily running all as specified

2

-

-

... More
Supply and installed commerical multiple scroll compressor suitable for 21 Ton capacity AC Plant on existing size Danfoss model no SZ185S4RC with refrigrent R407CR134a R404A R507A thermally protected system LP side PS 25 bar TS max 54 oC to -35 oC and HP side PS 31.9 bar TS max 65 oC to -35 oC complete with compressor oil including all connection complete all as directed. Make- DENFOS Model No. SZ185S4RC or as approved by GE (I).

2

-

-

... More
M&L for painting of out door AC Plant Unit with spray painting machine with emsynthetic enamelle paint of existing colour two coat and black paint in Angle iron / chanel / MS flat or stand after scratcing with sand paper or any other suitable mean up to satisfactory level of engr in Charge and Re-clean the the existing name plate or machine description number plate visible by any means complete all as directed.

4

-

-

... More
S&F in repair control fuse cartrage 6 to 30 Amp suitable for 21 TR Central AC Plant/ 22.5 TR package type AC Plant complete all as specified & directed.

6

-

-

... More
S&F in repair temperature controller suitable for 21 TR Central AC Plant/ 22.5 TR package type AC Plant complete all as specified & directed.

4

-

-

... More
S&F in repair ON/OFF switch push button as per sample suitable for 21 TR Central AC Plant/ 22.5 TR package type AC Plant complete all as specified & directed.

4

-

-

... More
S&F in repair Indicating lamp R/Y/B as per sample suitable for 21 TR Central AC Plant/ 22.5 TR package type AC Plant complete all as specified & directed.

6

-

-

... More
S&F in repair 3 phase selector switch for voltmeter and ammeter including all connections complete all as specified & directed.

4

-

-

... More
S&F in repair over load protection of condenser for AC plant suitable for 21 TR Central AC Plant / 22.5 TR Package Type AC Plant as required at site.

3

-

-

... More
S&F in repair over load protection of compressor for AC plant suitable for 21 TR Central AC Plant / 22.5 TR Package Type AC Plant as required at site.

3

-

-

... More
S&F in repair phase preventor for AC plant suitable for 21 TR Central AC Plant / 22.5 TR Package Type AC Plant as required at site.

4

-

-

... More
S&F in repair condenser fan blade for AC plant suitable for 21 TR Central AC Plant / 22.5 TR Package Type AC Plant as required at site.

2

-

-

... More
S&F MCCB 3 Pole , 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified.

1

-

-

... More
Cleaning or surface excavation or dressing not exceeding 30 cm deep around the area of outdoor of Nano & Polymer bldg,GE(I) R&D office area, P29 & transformer/ DG set area etc by cutting and removal/uprouting of unwanted grass/bushes, small trees including surface dressing and leveling by surface excavation wherever required complete in all respect or as directed.

1000

-

-

... More
Total amount with taxes in Figures

-

-

-

... More
Total amount with taxes in words

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.