Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Dec 2023
Closing Date22 Jan 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_634622_1Bid Award Id
ViewTender No
8685/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Disconnecting & dismantling of damaged unserviceable cable and Supply & laying of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including testing complete all as specified & directed. Note:- Earth work, Sand & Bricks shall be measured & paid separately under respective items
830
-
-
... More
Disconnecting & dismantling of damaged unserviceable cable and Supply & laying of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core including testing complete all as specified & directed. Note:- Earth work, Sand & Bricks shall be measured & paid separately under respective items
950
-
-
... More
Disconnecting & dismantling of damaged unserviceable cable and Supply & laying of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core including testing complete all as specified & directed. Note:- Earth work, Sand & Bricks shall be measured & paid separately under respective items
910
-
-
... More
Excavation in trenches n.exceeding 1.50m wide and n.exc 1.50m depth for foundation etc or for shafts, walls, cess-pits, manholes, pier holes, cable etc n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
732
-
-
... More
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified & directed.
234
-
-
... More
Returning, filling in including spreading, levelling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
497
-
-
... More
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
21032
-
-
... More
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified & directed. Note:- Punned thickness shall be measured for payment.
287
-
-
... More
M&L for boring under road horizontally of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed.
75
-
-
... More
M&L for 50 mm bore GI tubing (in replacement) 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/ as garden post including 2 Nos suitable mild steel FI clamps of size 35 x 3 mm to support pipe with pole complete all as specified & directed.
40
-
-
... More
S&F (in replacement) pole box junction three phase of size 297 mm x 250 mm x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint and inbuilt locking arrangement, outdoor type fix to pole with suitable MS clamp comprising of aluminium bus bar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 KA 240 volt complete all as specified & directed.
97
-
-
... More
M&L for repairing of unserviceable street light fitting (fixed on pole)of any type / make by replacing burn out / worn out/ weak HPSV lamp 250 watt and refixing the fitting in position after repair and testing complete all as specified & directed.
8
-
-
... More
M&L for repairing of unserviceable street light fitting (fixed on pole)of any type / make by replacing burn out / worn out/ weak HPSV lamp 150 watt and refixing the fitting in position after repair and testing complete all as specified & directed
4
-
-
... More
M&L for repairing of unserviceable street light T-5 fitting (fixed on pole)of any type / make by replacing burn out / worn out/ weak T-5 tube rod 24 watt and refixing the fitting in position after repair and testing complete all as specified & directed
4
-
-
... More
M&L for repair of building security light by replacement of worn out/ old linear fluroscent tube of 36 watt with energy efficient/ saving retrofit LED tube of nominal wattage - 18 watt having lumen out put 2100 lumen or above, colour temperature 6500 kelvin, size & length - G13 /T8/4 feet operating voltage 140 to 280 volt AC THD- 15% with integral / inbuilt driver and having short circuit and surge protection including minor addition / alteration in existing circuit as required complete all as specified & directed. Make:- Philips cat Part No. 929001178714 or equivalent make as specified in P.S.
6
-
-
... More
M&L for repair of building security light by replacement of worn out/ old linear fluroscent tube of 36 watt Fwith linear LED PLL lamp with extruded plasting body and PC diffuser complete with inbuilt driver of high efficacy of system wattage 18 watt length 419 mm lumen output 1800 lm or above, colour temp 6500 K suitable for existing 2G11 lamp holders including minor alteration in existing ckt as required complete all as specified & directed. Make:- Crompton cat Part No. LPLL-18CDL or equivalent make as specified in P.S.
7
-
-
... More
M&L for repairing of unserviceable street light fitting (fixed on pole) of any type / make by replacing burn out / worn out/ weak copper ballast 250 watt and refixing the fitting in position after repair and testing complete all as specified & directed
2
-
-
... More
M&L for repairing of unserviceable street light fitting (fixed on pole) of any type / make by replacing burn out / worn out/ weak copper ballast 150 watt and refixing the fitting in position after repair and testing complete all as specified & directed
3
-
-
... More
M&L for repairing of unserviceable search light fitting (fixed on watch tower) of any type / make by replacing burn out / worn out/ weak copper ballast 1000 watt and refixing the fitting in position after repair and testing complete all as specified & directed
3
-
-
... More
M&L for repairing of unserviceable street light T-5 fitting (fixed on pole)of any type / make by replacing burn out / worn out/ weak electronic ballast 2 x 24 watt and refixing the fitting in position after repair and testing complete all as specified & directed
3
-
-
... More
M&L for repairing of unserviceable street light fitting 70 - 400 watt, fixed on pole of any type / make by replacing burn out / worn out/ weak electronic ignitor and refixing the fitting in position after repair and testing complete all as specified & directed
3
-
-
... More
M&L for repairing of unserviceable search light fitting 1000 watt, fixed on watch tower of any type / make by replacing burn out / worn out/ weak electronic ignitor and refixing the fitting in position after repair and testing complete all as specified & directed
3
-
-
... More
M&L for repairing of unserviceable street light T-5 fitting (fixed on pole)of any type / make by replacing burn out / worn out/ weak bipin holder and refixing the fitting in position after repair and testing complete all as specified & directed
7
-
-
... More
M&L for repairing of unserviceable street light fitting 70 - 400 watt, fixed on pole of any type / make by replacing burn out / worn out/ weak holder for HPSV/MH fitting and refixing the fitting in position after repair and testing complete all as specified & directed
4
-
-
... More
M&L for repairing of unserviceable garden / gate light fitting of any type / make by replacing burn out / worn out/ weak Normel LED lamp 9 / 11 watt and refixing the fitting in position after repair and testing complete all as specified & directed
100
-
-
... More
M&L for repairing of unserviceable gate light fitting of any type / make by replacing burn out / worn out/ weak LED lamp 25 watt and refixing the fitting in position after repair and testing complete all as specified & directed
64
-
-
... More
M&L for repairing of unserviceable LED street light fitting of any type / make of 70 - 90 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 277 Volt 50 / 60 Hz AC supply complete all as specified & directed.
248
-
-
... More
M&L for repairing of unserviceable LED street / flood light fitting of any type / make of 100 - 150 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 277 Volt 50 / 60 Hz AC supply complete all as specified & directed.
110
-
-
... More
Note fro Sr item No. 15 to 31:- Contractor will make a identity (ie CANo. & firm name) using permanent paint marker pen on each component which will be replaced under repair of strret light and he will be liable to change his new replaced item without any extra cost which become unserviceable doe to any reason during execution period of CA and further upto defect liability period. It will be contractor responsibility to take the location of unserviceable street / garden/ post top/ search light fitting by MES rep at 9 AM at power house in every working day.
-
-
-
... More
S&F (in replacement) contactor 3 phase 40 Amps for street light timer in existing panel / location and connection including necessary alteration in panel / door as required for proper fixing & connection complete all as specified & directed. Make:- L&T type MNX 25 or equivalent make as specified in P.S.
11
-
-
... More
Taking down from watch tower of single ophase electric operated search light motor of capacity 2 HP, dismantling & rewinding with existing gauge size copper wire and as existing Nos of turns of coils for maintaining existing capacity of the motor and varnishing, drying including refixing & testing for proper rotation of search light fitting at watch tower complete all as specified & directed.
1
-
-
... More
S & F in replacement PVC insulated & sheathed flexible stranded copper conductor wire of nominal size 2.5 Sqmm 2 core complete all as specified and directed. complete all as specified and directed.
730
-
-
... More
M&L rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook, GI strip clamp etc for external dia 15 mm & connectioin from pole box to light fitting complete all as specified & directed.
630
-
-
... More
Supply, fixing, connecting & testing LED street light fitting of 90 watt high pressure die cast aluminium housing with minimum 125 lumen /watt system efficacy, covered potted designed driver or same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amp connector and S& F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction box to fitting complete all as specified & directed. Make:- Philips Cat Part No. BRP409LED 115 CW SLC FG PSU GR or equivalent make as specified in P.S.
170
-
-
... More
Supply, fixing, connecting & testing LED flood light fitting of 100 watt high pressure die cast aluminium housing with minimum 125 lumen /watt system efficacy, covered potted designed driver or same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amp connector and S& F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction box to fitting complete all as specified & directed. Make:- Philips Cat Part No. BVP 192LED 110 CW HO FG NB GR PSU or equivalent make as specified in P.S.
60
-
-
... More
Supply, fixing, connecting & testing LED flood light fitting of 210 watt high pressure die cast aluminium housing with minimum 125 lumen /watt system efficacy, covered potted designed driver or same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amp connector and S& F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction box to fitting complete all as specified & directed. Make:- Philips Cat Part No. BVP 483LED 185 SMB PSU GR or equivalent make as specified in P.S.
45
-
-
... More
Supply, fixing, connecting & testing LED street light fitting of 35 watt high pressure die cast aluminium housing with minimum 125 lumen /watt system efficacy, covered potted designed driver or same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amp connector and S& F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction box to fitting complete all as specified & directed. Make:- Philips Cat Part No. BRP 046 LED 30 CW MR S1 PSU GR or equivalent make as specified in P.S.
85
-
-
... More
Supply, fixing, connecting & testing LED street light fitting of 70 watt high pressure die cast aluminium housing with minimum 125 lumen /watt system efficacy, covered potted designed driver or same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amp connector and S& F PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction box to fitting complete all as specified & directed. Make:- Philips Cat Part No. BRP 062 LED 84 CW SLC S1 PSU or equivalent make as specified in P.S.
136
-
-
... More
S&F post top lantern LED type 20 watt 220 volt AC outdoor type with decorative post top 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified & directed.
24
-
-
... More
S&F new generation energy saving environmental friendly, long life aesthetically designed landscape luminaire for diffused lighting with high power LED bollard 8 watt as light source for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified & directed.
36
-
-
... More
S&F LED solar street light fitting 12 watt all in one type including galvanized steel pole in built lithium iron battery, solar panel, charge controller with dusk down sensor with compact body complete all as specified & directed.
3
-
-
... More
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
52
-
-
... More
S&F MS bracket for mounting flood light fitting made out of MS angle iron of size 40 x 40 x 6 mm of length not less than 1.0 mtr fixed to pole / earth and grout using PCC & clamp, nut & bolts painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
27
-
-
... More
S&F of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is less than 30 lux and for switching off more than 10 lux. The nature switch along with suitable power contactors, incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure make of rust proof, elctric shock proof and FR grade SMC junction box confirming to IP 54 complete all as specified for the following:-
-
-
-
... More
Suitable for three phase load of 5 Kw with contactors (single phase- 3 Nos), incoming & outgoing MCB SP (06 Nos), rating of 20-25 amp & circuit wiring of minimum 10 Sqmm.
7
-
-
... More
Suitable for single phase load of 2 Kw with contactors (single phase- 1 Nos), incoming & outgoing MCB SP (06 Nos), rating of 20-25 amp & circuit wiring of minimum 10 Sqmm.
7
-
-
... More
S&F MCB DB SPN 2 way double door type, comprising of one MCB SPN 16 Amp 'B' series 415 volts including fixing of DB on pole / wall with suitable arrangement for the garden light including making wall surface smooth as existing using plastering and white wash complete all as specified & directed.
14
-
-
... More
S&F (in replacement) contactor 3 phase 25 Amps for street light timer in existing panel / location and connection including necessary alteration in panel / door as required for proper fixing & connection complete all as specified & directed. Make:- L&T type MNX 25 or equivalent make as specified in P.S.
8
-
-
... More
M&L for 40 mm bore GI tubing (in replacement) 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/ as garden post including 2 Nos suitable mild steel FI clamps of size 35 x 3 mm to support pipe with pole complete all as specified & directed.
35
-
-
... More
M&L for poles painting with applying two coats of aluminium colour synthetic enamel paint including preparation of surfaces to perimeter light stand 2.5 mtr long 40 mm GI pipe and applying two coats of black bituminous paint over the embedded portion of pole complete all as specified & directed.
100
-
-
... More
M&L for replacement of lamp holder of post top lantern fitting complete all as specified & directed. Make:- Model No. Athena2 Cat part No. LHDC 12115099
10
-
-
... More
M&L for repairing of unserviceable LED street light any make / model of 20-35 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 volt 50 / 60 Hz AC supply complete all as specified & directed.
50
-
-
... More
Schedule of Credit (MINUS) Rs. 77,631.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements