Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date14 Mar 2024
Closing Date18 Apr 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pump Chamber

1

-

-

... More
Setting plate (clearance adjustment plate)

2

-

-

... More
Impellers (Cast Iron IS: 210 with 1.5 to 2% Ni)

2

-

-

... More
Mechanical seal (out side) lower

1

-

-

... More
Mechanical seal (in side) upper

1

-

-

... More
O' ring set

2

-

-

... More
Ball bearing lower

2

-

-

... More
Ball bearing upper

1

-

-

... More
Key for shaft

2

-

-

... More
Cable seal

2

-

-

... More
Cable gromate

2

-

-

... More
Moisture sensor

1

-

-

... More
Thermister (Top)

2

-

-

... More
Auto coupling gasket

2

-

-

... More
Oil (IOC OIL-12)

3

-

-

... More
Auto coupling sliding bracket

2

-

-

... More
Taking out by raising / Lowering of non clog sewage submersible pump set of 03HP/05 HP of Make : AQUA / KIRLOSKAR with the help of chain pully block from sewage sump after disconnecting electric & sewage coupling connections, dismantling pump and motor and carrying out repairs / replecement of defective parts, cleaning of Impeller and volute casing, clogged discharge line. Reassembling, painting the pump set and re-installation by lowering into sewage sump connecting up complete and testing all running parameters complete as directed by Engineer-in-Charge. (Replacement of defective parts and Dewatering will be paid saperately under respective Item of BOQ_) Note : Contractor has to make arrangement for pumping of sewage effluents from sump well as long as pump remains under repair / rewinding by fitting his own pump including other T&P etc. all T&P will be brought by contractor nothing shall be issued by dept.

6

-

-

... More
Re-winding of three phase, 415Volt electric motor of capacity 03 HP of non clog submersible pumps Make : AQUA / KIRLOSKAR after dismantling the startor and rotor, removing burnt windings, cleaning the slots, rewinding the motor with super enamelled quality hermatic grade copper winding wire of proper gauge and number of turns as per the existing windings, (Class 'F' insulation including Dr. back ELMO-50 Varnish, pre-heating to remove moisture and vaccum pressure impregnated for air bubble free varnishing, with slot liners & seperators, fibre-glass sleeves, baking to 150ºC for 12 hrs in special baking oven to suit the motor for IP-68 protection) of the 03 HP motor reassembling and testing all as directed by Engineer-in-Charge. Note : Contractor has to make arrangement for pumping of sewage effluents from sump well as long as pump remains under reair / rewinding by fitting his own pump including other T&P etc. all T&P will be brought by contractor nothing shall be issued by dept.

3

-

-

... More
Re-winding of three phase, 415Volt electric motor of capacity 05 HP of non clog submersible pumps Make : AQUA / KIRLOSKAR after dismantling the startor and rotor, removing burnt windings, cleaning the slots, rewinding the motor with super enamelled quality hermatic grade copper winding wire of proper gauge and number of turns as per the existing windings, (Class 'F' insulation including Dr. back ELMO-50 Varnish, pre-heating to remove moisture and vaccum pressure impregnated for air bubble free varnishing, with slot liners & seperators, fibre-glass sleeves, baking to 150ºC for 12 hrs in special baking oven to suit the motor for IP-68 protection) of the 05 HP motor reassembling and testing all as directed by Engineer-in-Charge. Note : Contractor has to make arrangement for pumping of sewage effluents from sump well as long as pump remains under reair / rewinding by fitting his own pump including other T&P etc. all T&P will be brought by contractor nothing shall be issued by dept.

3

-

-

... More
Replacement of following parts for making the pump 03 HP Make- AQUA in fully serviceable condition during the process of repair, as per existing Size:-

-

-

-

... More
Pump Chamber

3

-

-

... More
Setting plate (clearance adjustment plate)

2

-

-

... More
Impellers (Cast Iron IS: 210 with 1.5 to 2% Ni)

2

-

-

... More
Mechanical seal (out side) lower

3

-

-

... More
Mechanical seal (in side) upper

2

-

-

... More
O' ring set

2

-

-

... More
Ball bearing lower

2

-

-

... More
Ball bearing upper

3

-

-

... More
Key for shaft

2

-

-

... More
Cable seal

2

-

-

... More
Cable gromate

22

-

-

... More
Moisture sensor

3

-

-

... More
Thermister (Top)

2

-

-

... More
Auto coupling gasket

6

-

-

... More
Oil (IOC OIL-12)

15

-

-

... More
Auto coupling sliding bracket

2

-

-

... More
Replacement of following parts for making the pump 05 HP Make- KIRLOSKAR in fully serviceable condition during the process of repair, as per existing aize:-

-

-

-

... More
Pump Chamber

2

-

-

... More
Setting plate (clearance adjustment plate)

2

-

-

... More
Impellers (Cast Iron IS: 210 with 1.5 to 2% Ni)

2

-

-

... More
Mechanical seal (out side) lower

3

-

-

... More
Mechanical seal (in side) upper

3

-

-

... More
O' ring set

2

-

-

... More
Ball bearing lower

3

-

-

... More
Ball bearing upper

2

-

-

... More
Key for shaft

2

-

-

... More
Cable seal

2

-

-

... More
Cable gromate

2

-

-

... More
Moisture sensor

3

-

-

... More
Thermister (Top)

2

-

-

... More
Auto coupling gasket

3

-

-

... More
Oil (IOC OIL-12)

15

-

-

... More
Auto coupling sliding bracket

2

-

-

... More
Taking out by raising / lowering of non clog sewage submersible pump set of Make : KIRLOSKAR 10 HP, 3 phase, 415 Volt, AC supply, 50 Hz with help of chain pully block from sewage sump well of STP after disconnecting electrical and mechanical connection, dismantling pump and motor and carrying out repairs / replecement of defective parts, cleaning of impeller and volute casing, clogged discharge line. Re-assembling the pump set and re-installation by lowering into sewage sump connecting up complete and testing all running parameters all as directed by Engineer-in-Charge. (Replacement of defective parts and Dewatering will be paid saperately under respective Item of BOQ_) Note : Contractor has to make arrngement for pumping of sewage effluents from sump well as long as pump remains under repair/rewinding by fitting his own pump including other T&P etc. all T&P will be brought by contractor nothing shall be issued by dept.

6

-

-

... More
Rewinding the electric motor of NS type non clog submersible sewge pump 3 phase, 415Volt, Capacity 10 HP of Make : Kirloskar, after dismantling the startor and rotor, removing burnt windings, cleaning the slots, stampings and rewinding with super enamelled quality hermatic grade copper winding wire of proper gauge and number of turns as per the existing windings, including numex paper, glass paper, thimble, glass sleeve, main lead, backtoll, Varnishing and drying in oven, including fitment of thermostat protection relay, painting including required nut bolts (stainless steel) reassembling and testing to ensure leak tightness of the joints. Note : Contractor has to make arrngement for pumping of sewage effluents from sump well as long as pump remains under repair / rewinding by fitting his own pump including other T&P etc. all T&P will be brought by contractor nothing shall be issued by dept.

5

-

-

... More
Supply & Fixing in replacement following items in replacement for making the functional of non clog submersible pump set of Make :- Kirloskar / KSB of 10 HP capacity in fully serviceable condition during the process of repair as per existing size complete:-

-

-

-

... More
Lubricant oil up to the level for lubricating mechanical seals of Make : IOC-Servo system-317 or HPCL-Enklo-57

20

-

-

... More
Lubricant grease as required for lubricating antifriction ball bearings of Make : IOC Servogem-2 or HPCL-Lithon-2.

2

-

-

... More
Part 15100 - Enclosed Impeller

3

-

-

... More
Part-23002- Mech Seal (in board) Sic Vs Sic size-40mm

2

-

-

... More
Part-23002- Mech Seal (in board) Sic Vs Sic size-55mm

2

-

-

... More
Part-23003 - Mech Seal (out board) Carbon Vs St. St size-40mm

2

-

-

... More
Part-23003 - Mech Seal (out board) Carbon Vs St. St size-55mm

2

-

-

... More
Part- 26001 - Ball Bearing (Lower) SKF 6309-2RS1 or equivalent

2

-

-

... More
Part- 26001 - Ball Bearing (Lower) SKF 7312 BG

2

-

-

... More
Part- 26002 - Ball Bearing (Upper) SKF 6306-2RS1 or equivalent.

3

-

-

... More
Part - 32000 - Key for Impeller

2

-

-

... More
O' ring set for Cap-10 HP sewage pump

2

-

-

... More
Part - 66900 - Screw for Impeller

2

-

-

... More
Part -84501 & 03 - Washer for Cable Seal for Power Cable

3

-

-

... More
Part -84502- Washer for Cable Seal for Control Cable

2

-

-

... More
Part - 91001& 02 - Cable Gland

2

-

-

... More
Part - 91200 - Terminal Board

3

-

-

... More
Power copper cable 8 Core (4 X 4 Sq mm + 4 X 1.5 Sq mm)

48

-

-

... More
Power copper cable 8 Core X 2.5Sq mm)

48

-

-

... More
Control copper cable 1100Volt grade submersible type EBXL 10 Sqmm 3 core

30

-

-

... More
Control copper cable 1100Volt grade submersible type EBXL 4 Sqmm 3 core

30

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 10 Sq mm 4 Core

50

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 10 Sq mm 3 Core

15

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 4 Sq mm 4 Core

15

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 4 Sq mm 3 Core

15

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 2.5 Sq mm 4 Core

10

-

-

... More
FR PVC Insulated sheathed multistranded copper conductor flexible cables for 1100 Volt grade conforming to IS : 694 of sizes 1.5 Sq mm 4 Core

15

-

-

... More
Part - 91400 - Cable Seal

2

-

-

... More
Part - 91401 & 03 - Cable Seal for Power Cable

2

-

-

... More
Part - 91402 - Cable seal for Control Cable

2

-

-

... More
Part - 93200 - Moisture Sensor

2

-

-

... More
Rubber diaphragm cap- 10 HP

2

-

-

... More
Guide Shoe Cap-10 HP

1

-

-

... More
Control copper cable 1100Volt grade submersible type EBXL 10 Sqmm 3 core

15

-

-

... More
Control copper cable 1100Volt grade submersible type EBXL 4 Sqmm 3 core

15

-

-

... More
Transportation of monoblock pump set of capacity 0.5 HP / 1 HP AC 3 phase, 415 Volt from STPs at any location / Yard in old Cantt area Allahabad to contractor's workshop, dismantling for carrying out necessary repairs / renewal of parts of pump and refixing the same after repairs including testing complete all as specified as directed by Engineer-in-Charge.

2

-

-

... More
Cutting, opening of winding, re-winding of monoblock pump set of any make and rewinding with same size & number of coils with super enamelled copper winding wire, varnishing, packing and reassembling of same complete

2

-

-

... More
Supply & Fixing in replacement following items for making functional of the monoblock pump set of capacity 0.5 HP / 1 HP AC 3 phase, 415 Volt in fully serviceable condition during the process of repair as per existing (for item No. 98 to 113).

-

-

-

... More
Repairing of pump by re-threading of worn out studs holes and Supply & Fixing over size studs with nut and washer for balancing and repairing of pump shaft.

2

-

-

... More
Water seal and packing complete

2

-

-

... More
Driven end bearing of pump shaft

2

-

-

... More
Non driven end bearing of pump shaft

2

-

-

... More
Cooling fan

2

-

-

... More
Cooling fan cover

2

-

-

... More
Cast iron Impeller

2

-

-

... More
Connection plate

2

-

-

... More
Sleeve in Pump's cover and making size equal to outer dia size of bearing in back cover.

2

-

-

... More
Remetaling of Pump shaft, turning for bring it to Internal dia size of bearing in to front end cover.

1

-

-

... More
Remetaling of Pump shaft, turning for bring it to Internal dia size of bearing in rear end cover.

2

-

-

... More
Neck ring

2

-

-

... More
Centrifugal switch

2

-

-

... More
Capacitor of 4/6 mfd capacity

2

-

-

... More
Removing of Monoblock pump set from it's existing position and re-fixing of repaired pump set including Supply & Fixing worn out nuts & bolts and making necessary electric connection complete all as specified & directed.

2

-

-

... More
Painting to pump set externally complete with synthetic enamel smoke grey paint with spray machine after preparation of surfaces complete all as specified & directed.

2

-

-

... More
Transportation of monoblock pump set of capacity 2 HP / 3 HP AC 3 phase, 415 Volt from STPs at any location / Yard in old Cantt area Allahabad to contractor's workshop, dismantling for carrying out necessary repairs / renewal of parts of pump and refixing the same after repairs including testing complete all as specified as directed by Engineer-in-Charge.

2

-

-

... More
Cutting, opening of winding, re-winding of monoblock pump set of any make and rewinding with same size & number of coils with super enamelled copper winding wire, varnishing, packing and reassembling of same complete

2

-

-

... More
Supply & Fixing in replacement following items for making functional of the monoblock pump set of capacity 2 HP / 3 HP AC 3 phase, 415 Volt in fully serviceable condition during the process of repair as per existing (for item No. 117 to 132).

-

-

-

... More
Repairing of pump by re-threading of worn out studs holes and Supply & Fixing over size studs with nut and washer for balancing and repairing of pump shaft.

2

-

-

... More
Water seal and packing complete

2

-

-

... More
Driven end bearing of pump shaft

2

-

-

... More
Non driven end bearing of pump shaft

2

-

-

... More
Cooling fan

2

-

-

... More
Cooling fan cover

2

-

-

... More
Cast iron Impeller

2

-

-

... More
Connection plate

2

-

-

... More
Sleeve in Pump's cover and making size equal to outer dia size of bearing in back cover

2

-

-

... More
Remetaling of Pump shaft, turning for bring it to Internal dia size of bearing in to front end cover

1

-

-

... More
Remetaling of Pump shaft, turning for bring it to Internal dia size of bearing in rear end cover

2

-

-

... More
Neck ring

2

-

-

... More
Centrifugal switch

2

-

-

... More
Capacitor of 10 mfd capacity

2

-

-

... More
Removing of Monoblock pump set from it's existing position and re-fixing of repaired pump set including Supply & Fixing worn out nuts & bolts and making necessary electric connection complete all as specified & directed.

2

-

-

... More
Painting to pump set externally complete with synthetic enamel smoke grey paint with spray machine after preparation of surfaces complete all as specified & directed.

2

-

-

... More
Materail & Labour for taking out / Dismantling of Air blower pump set of rating 3 phase 440 Volt supply of capacity up to 20 HP / 25 HP from STP plant at any location and transporting the same to the authorised workshop for repair and transporting back to the site and making connection and testing complete all as specified & directed by the Engineer-in-Charge. Note : Parts renewed shall be measured & paid separately under respective item of BOQ.

2

-

-

... More
Cutting out the existing winding of the motor, taking out damage / burnt winding wire from startor, cleaning the slot and re-winding the same with supper enamelled copper winding wire of appropriate size including insulating material such as varnishing, paking and furnishing with the insulating sleeve and making connection complete all as specified & directed by Engineer-in-Charge.

2

-

-

... More
Repairing of pump by re-threading of worn out studs holes and Supply & Fixing over size studs with nut and washer for balancing and repairing of pump shaft.

8

-

-

... More
Repairing of pump shaft by depositing metal on it by brazing, grinding and polishing to make appropriate size of the shaft complete as specified & as directed by the Engineer-in-Charge.

3

-

-

... More
Gun metal / Stainless steel bush of pump shaft of required size complete all as specified & as directed by the Engineer-in-Charge.

8

-

-

... More
Driven end bearing of blower shaft complete all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Non-driven end bearing of blower shaft complete all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Gland packing complete all directed by the Engineer-in-Charge.

4

-

-

... More
Coupling with studs between motor & air blower complete as directed by the Engineer-in-Charge.

4

-

-

... More
Suction air filter complete as directed by the Engineer-in-Charge.

3

-

-

... More
Suction silencer complete as directed by the Engineer-in-Charge.

2

-

-

... More
Neck ring complete all as specified & directed by the Engineer-in-Charge.

8

-

-

... More
Ball bearing of motor shaft complete as specified & directed by the Engineer-in-Charge.

4

-

-

... More
Replacment of air blower pully as per sample or suiatable at site complete as specified & as directed by the Engineer-in-Charge.

3

-

-

... More
Strip opening of air blower & cleaning of air filter and silencer as per manufacurer Instruction complete as directed by the Engineer-in-Charge.

4

-

-

... More
Draining of used oil from air blower & supply and filling of new oil in air blower up to reuired level complete all as specified & as directed by the Engineer-in-Charge.

15

-

-

... More
Fan belt suitable for Air Compressor 500Cum per Hours including connection complete as directed by Engineer-in-Charge

4

-

-

... More
Pressure Gauge (Water) range 0-4.20 Kg/Sqcm complete as directed by Engineer-in-Charge.

4

-

-

... More
Cuttting of grass and vegitation shrubs and removing the same at site around the sewage treatment plant area at different location at Old Cantt Allahabad Cantt at interval of three month complete as directed by the Engineer-In-Charge. Note : Each cutting will be measured separately.

4000

-

-

... More
Provision for Bactroligical test & sample collection from various STP plants in sterilized bottle and testing shall be done from Govt Lab / Approved by UP Pollution Control Board, on monthly basis as per the Environment (Protection) Rules-1986, in Schedule-I, in permissible standards in sewage treated water for inland surface water i.e. (a) Suspended solids Max 50 mg/litres (b) PH value (6.5 PH to 9.0 PH) (c) Biochemical Oxygen Demand (BOD) (5 day at 20 deg celcius) Max 30 (d) COD (Chemical Oxygen Demand) up to 250 mg/l (e) Focal Coliform (FC) Most Probable Number per 100 millimeter (MPN/100 ml) 1000

21

-

-

... More
De-sludging of existing sewage collection well of size 6 Mtr dia and 10 Mtr depth and getting out sludge through sucking super soucer machine and depositing to a distance exceeding 1.5 KM but not exc 2 KM out side MD land at isolated places (Location -STP Saraswati Vihar). Note : Pumping out sludge water from sewage collection tank by using Diesel Engine driven pumps and necessary diesel is to be arranged / provided by Contractor

170

-

-

... More
De-sludging of existing sewage collection well of size 4.5 Mtr dia and 10 Mtr depth and getting out sludge through sucking super soucer machine and depositing to a distance exceeding 1.5 KM but not exc 2 KM out side MD land at isolated places (Location -STP Saraswati Vihar Boosting Station). Note : Pumping out sludge water from sewage collection tank by using Diesel Engine driven pumps and necessary diesel is to be arranged / provided by Contractor

80

-

-

... More
De-sludging / cleaning of existing sludge drying bed of size (6.40 X 6.40 Mtrs) and depth 0.8 M by any means i.e. manually or by mechanical appliances complete by removing the sludge / vegetation and depositing sludge at abandoned places in the Cantt area and deposited the same where directed by Engineer-in-Charge including supply and spreading of sand up to 150 mm thick on top of filter bed complete as specified & directed by Engineer-in-Charge. (Location-STP Saraswati Vihar)

150

-

-

... More
De-sludging / de-watering of existing equalizer tank of Sewage Treatment Plant of size 8 Mtr dia x 5 Mtr depth not exceeding 5 Mtr) by any means i.e. mechanical appliaces complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing equalizer tank and removing the slude to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from equalizer tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

110

-

-

... More
De-sludging / de-watering of existing flow-culator tank of Sewage Treatment Plant of Size 3 Mtr x 3 Mtr and depth not exceeding 5 Mtr by any means i.e. mechanical appliaces complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing flow-culator tank and removing the slude to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from Flowculator tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

20

-

-

... More
De-sludging / de-watering of existing tube settler tank of sewage treatment plant of size 4 Mtr x 4 Mtr and depth not exceeding 5 Mtr by any means i.e. mechanical appliaces and through sucking super socker machine complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing tube settler tank and removing the slude to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from Flowculator tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

35

-

-

... More
De-sludging / de-watering of existing chlorine contact tank of sewage treatment plant of size 3.5 Mtr dia and depth not exceeding 5 Mtr and getting out through sucking super shocker machine and removing the sludge to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

25

-

-

... More
De-sludging / de-watering of existing TWT tank of sewage treatment plant of size 3.5 Mtr dia and depth not exceeding 5 Mtr) and getting out through sucking super shocker machine and removing the sludge to a distance exceeding 1.5 KM but not excedding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

25

-

-

... More
De-sludging / de-watering of existing MBBR tank of sewage treatment plant of size 4.5 Mtr dia and depth not exceeding 5 Mtr by means i. e. mechanical appliances complete including working under foul condition and depositing of solid waste and getting out through sucking super shocker machine and removing the sludge to a distance exceeding 1.5 KM but not excedding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Saraswati Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

40

-

-

... More
Floating media for MBBR reactors in MBBR tank as per Sample suitable for sewage treatment, having density less than water including removing deformed and worn out filter media complete as directed by Engineer-in-Charge.

25

-

-

... More
PVC tube suttler of size 580 mm x 140 mm in tube settler tank including taking down old unserviceable PVC tube settler complete all as specified & directed by Engineer-in-Charge.

175

-

-

... More
De-sludging of existing sewage collecting well of size 4.50m x 3.80m depth 6 mtr and getting out sludge through sucking super shocker machine and depositing to a distance exceeding 1.5 KM but not exceeding 2 KM out side MD land at isolated place as directed by Engineer-in-Charge. (Location -STP Triveni Vihar) Note : Pumping out sludge water from sewage collection well / tank by using Diesel Engine Operated pump and necessary diesel is to be arranged by contractor and included in unit quoted rates and not any claim entertained.

50

-

-

... More
De-sludging / cleaning of existing sludge drying beds of size 4.4 m x 4.4 m depth 0.8 m by any means i.e. manually or by mechanical appliances complete by removing the sludge / vegitation and disposing sludge at abandoned places inside cantt area complete all as specified & as directed by Engineer-in-Charge including supply and spreading of sand up to 150 mm thick on top of filter bed complete.(Location - STP Triveni Vihar)

35

-

-

... More
De-sludging / de-watering of existing equalizer tank of sewage treatment plant of size 4.5 m x 2.30 m depth not exceeding 10.0 m by any means i.e. mechanical appliaces complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing equalizer tank and removing the sludge to a distance not exceeding 2.0 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Triveni Vihar). Note : Pumping out sludge water from equalizer tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

22

-

-

... More
De-sludging / De-watering of existing FAB reactor tank of sewage treatment of size 1.90 m x 3.40 m depth not exceeding 5 Mtr by means of meachanical appliances or through sucking super shocker machine complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing settler tank and removing the sludge to a distance not exceeding 2 KM in a sealed container out side of MD land and deposited the same where directedby Engineer-in-Charge including replaced PVC (approximately -15 Kg) and tube settler (Approximately -250 Nos) as per existing size for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surfaces complete all as specified & directed. (Location - STP Triveni Vihar) Note : Pumping out sludge water from FAB reactors tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

15

-

-

... More
De-sludging / de-watering of existing tube settler tank of sewage treatment plant of size 1.90 m x 3.40 m depth not exceeding 5 Mtr by any means i.e. mechanical appliaces or through sucking super socker machine complete including working under foul condition and depositing of solid waste (silt) in any proportion and silted soil from the existing tube settler tank and removing the slude to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location :- STP Triveni Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

15

-

-

... More
De-sludging / de-watering of existing Chlorine contact tank, filter feed tank & storage tank of sewage treatment plant of size 1.0 m x 3.0 m depth not exceeding 2.0 Mtr and getting out through sucking super shocker machine and removing the sludge to a distance not exceeding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete as directed by Engineer-in-Charge. (Location : STP Triveni Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

2

-

-

... More
De-sludging / de-watering of existing TWT tank of Sewage Treatment Plant of size 1.0 m x 3.0 m depth not exceeding 2 m and getting out through sucking super shocker machine and removing the sludge to a distance exceeding 1.5 KM but not excedding 2 KM in a sealed container out side of MD land and depositing the same where directed by Engineer-in-Charge including straining PVC media and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location : STP Triveni Vihar). Note : Pumping out sludge water from tube settler tank by using Diesel Engine Operated pump and necessary Diesel is to be arranged by Contractor and included in unit quoted rates and not any claim entertained.

3

-

-

... More
Preparation of old painted surfaces of steel surfaces such as sheets, filters, compressor, pipe lines, mild steel ladders, column pipes any size of STP, over 10 CM width or girth and applying two coats of synthetic enamel black or blue paint as per existing surface complete all as specified & directed. (Location : STP Saraswati Vihar and STP Triveni Vihar)

25

-

-

... More
Painting of LT Panel of size 1.5 m x 1.0 m x 4.0 m deep with two coats of synthetic enamel smoke grey paint on steel surfaces complete all as specified & as directed by the Engineer-in-Charge

10

-

-

... More
Required to clear the choked casing of non-clog submersible pump / column pipe by removing sludge / silt or solids & refixing the pump / column pipe in position & testing for proper functioning including all T & P required for removal & refixing including de-watering the sump upto desired level with own arangement all as specified & directed by Engineer-in-Charge for non-clog submersible pumps of capacity 3 HP to 20 HP complete all as specified & as directed.

16

-

-

... More
Making / fabricating glow sign board made up of Mild steel sheet not less than 3 mm thick of size 1.5 m x 1.0 m, sky blue colour Illumination top and writing with white coloured Illumination tape, letter size not less than 10 cm, number of letter 90 [Approx], including making suitable size frame made up of angle iron frame of size 40mm x 40mm x 6mm for holding of sign board and two number of leg made with angle iron of size 40mm x 40mm x 6mm, 1.2 RM long above ground level complete including grouting with PCC 1:2:4 using 40 mm stone aggregate up to 0.45 m deep in ground including excavation in soft loose soil and removing surplus soil from site including two coat of painting with synthetic enamel paint over one coat of red oxide primer after preperation of steel surface complete all as specified & directed.

2

-

-

... More
Making / fabricating glow sign board made up of Mild steel sheet not less than 3 mm thick of size 1.5 m x 0.5 m, sky blue colour Illumination top and writing with white coloured Illumination tape, letter size not less than 10 cm, number of letter 40 [Approx], including making suitable size frame made up of angle iron frame of size 40mm x 40mm x 6mm for holding of sign board and two number of leg made with angle iron of size 40mm x 40mm x 6mm, 1.2 RM long above ground level complete including grouting with PCC 1:2:4 using 40 mm stone aggregate up to 0.45 m deep in ground including excavation in soft loose soil and removing surplus soil from site including two coat of painting with synthetic enamel paint over one coat of red oxide primer after preperation of steel surface complete all as specified & directed.

2

-

-

... More
M&L for cast iron fittings viz bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, ‘Y’ junction, double branch, cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes upto 150mm bore complete all as specified & directed.

275

-

-

... More
M&L for sluice valve Class PN-1.6 cast iron body with forged steel spindle, non rising type, with cast iron wheel head, both end flanged, ISI marked for 150 mm bore including neoprene rubber gasket, nuts, bolts, washer etc complete all as specified & directed by Engineer-in-Charge.

4

-

-

... More
M&L for sluice valve Class PN-1.6 cast iron body with forged steel spindle, non rising type, with cast iron wheel head, both end flanged, ISI marked for 100 mm bore including neoprene rubber gasket, nuts, bolts, washer etc complete all as specified & directed by Engineer-in-Charge.

4

-

-

... More
Joints of submersible cable of size 6 Sqmm 3 core to 25 Sqmm 3 core 1100 volts by means of jointing materials i.e. Water proof tube, pasting materials & making the leak proof joint complete all as specified & directed by Engineer-in-Charge.

10

-

-

... More
Connecting, testing and commissioning fully automatic Star Delta Starter in sheet steel enclosure type MN-16F with single phase protection suitable for up to 30 HP, 3 Phase, 415 Volts, 50 Hz having all standard accessories complete all as specified & directed.

4

-

-

... More
Connecting, testing and commissioning fully automatic Star Delta Starter in sheet steel enclosure type MN-16F with single phase protection suitable for up to 50 HP, 3 Phase, 415 Volts, 50 Hz having all standard accessories complete all as specified & directed.

4

-

-

... More
Flat submersible cable heavy duty PVC Insulated and sheathed 16 Sqmm 3 core multi strandred copper conductor cable fully water proof suitable for1100 volts grade complete all as specified & directed.

200

-

-

... More
Flat submersible cable heavy duty PVC Insulated and sheathed 10 Sqmm 3 core multi strandred copper conductor cable fully water proof suitable for1100 volts grade complete all as specified & directed.

200

-

-

... More
Connecting & testing new generation energy saving & environmental friendly long life versatile, pressure die-cast aluminium IP-66 protection LED street light fitting not less than 90 Watt on existing street pole including painting one coat of existing pole and street light bracket with existing colour and replacement unserviceable 3 core PVC unsheathed copper wire from existing junction box up to street light fitting complete all as specified & directed by Engineer-in-Charge. Make : Havells Cat Part No. ENDURACITILINERNEOSL 90WLED757SASYBOTG / Crompton Cat Part No. LSTP90CDL / Bajaj Cat No: BRLEP90WLEDV2

12

-

-

... More
M&L for Gun Metal Gate Valve with iron wheel head, screwed both ends for iron of size 20 mm size complete all as specified & directed.

8

-

-

... More
M&L for Gun Metal Gate Valve with iron wheel head, screwed both ends for iron of size 25 mm size complete all as specified & directed.

6

-

-

... More
M&L for MCCB 4 pole 415 Volts 250 Amps having breaking capacity 36 KA with thermal magnetic and microprocessor release including taking down old unserviceable MCCB complete all as specified & directed.

2

-

-

... More
M&L for MCCB 4 pole 415 Volts 200 Amps having breaking capacity 36 KA with thermal magnetic and microprocessor release including taking down old unserviceable MCCB complete all as specified & directed.

2

-

-

... More
M&L for MCCB 4 pole 415 Volts 160 Amps having breaking capacity 25 KA with thermal magnetic and microprocessor release including taking down old unserviceable MCCB complete all as specified & directed.

2

-

-

... More
M&L for Gate valve 40 mm dia with butterfly handle steel spindle confirming to IS : 13095 complete all as specified & directed.

4

-

-

... More
M&L for Gate valve 50 mm dia with butterfly handle steel spindle confirming to IS : 13095 complete all as specified & directed.

5

-

-

... More
M&L for Gate valve 65 mm dia with butterfly handle steel spindle confirming to IS : 13095 complete all as specified & directed.

3

-

-

... More
M&L for Gate valve 80 mm dia with butterfly handle steel spindle confirming to IS : 13095 complete all as specified & directed.

8

-

-

... More
M&L for Single phase preventer model VSP-2, 415Volt, three phase, 50 Hz AC complete all specified & directed.

6

-

-

... More
M&L for MCB TPN 415 Volt, 63 Amps, B Curve, 10KA breaking capacity complete all as specified & directed.

6

-

-

... More
M&L for MCB TP 415 Volt, 32 Amps, B Curve, 10KA breaking capacity complete all as specified & directed.

4

-

-

... More
M&L for MCB TP 415 Volt, 16 Amps, B Curve, 10KA breaking capacity complete all as specified & directed.

4

-

-

... More
M&L for Compact LED indicating lamps (Red,Yellow, Blue & green) suitable for 220 Volt to 240 Volt 50 Hz AC complete all as directed by Engineer-in-Charge.

18

-

-

... More
M&L for Push button for start (Red & Green) as per existing size & shape complete as directed by Engineer-in-Charge.

12

-

-

... More
M&L for Power contactor model-3TF33 00-0A, AC 3-22 Amp 415 Volt as per existing size & shape complete as directed by Engineer-in-Charge.

2

-

-

... More
M&L for Power contactor model-3TF34 00-0A, AC 3-32 Amp 415 Volt as per existing size & shape complete as directed by Engineer-in-Charge.

3

-

-

... More
M&L for Power contactor model-3TF35 00-0A, AC 3-38 Amp 415 Volt as per existing size & shape complete as directed by Engineer-in-Charge.

3

-

-

... More
M&L for On-delay timer 03-60 second type 3 RP 1576-INP 30 8K as per existing complete as directed by Engineer-in-Charge.

2

-

-

... More
M&L for Over load relay 12.5-20 Amp to match as per existing complete as directed by Engineer-in-Charge.

1

-

-

... More
M&L for Over load relay 16-25 Amp to match as per existing complete as directed by Engineer-in-Charge.

2

-

-

... More
M&L for Over load relay 25-36 Amp to match as per existing complete as directed by Engineer-in-Charge.

2

-

-

... More
M&L for filter media (coarse sand) bed of sludge drying bed as per existing size complete including taking down / out old damaged / chocked filter media bed or coarse sand and removing from site and disposed as directed by Engineer-in-Charge complete all as directed at both STPs at Saraswati Vihar & Triveni Vihar.

30

-

-

... More
M&L for MCB SP 6-32 Amps, 230 Volts, B Curve, breaking kapacity of 10 KA complete all as specified & directed.

5

-

-

... More
Collecting sample of water in sample bottles and testing of water sample in different pockets of Old Cantt area Allahabad, in respect of the following parameters, to get it tested from State Public health laboratory or NABL Accredited Lab, complete all as specified and directed . Note : The parameter to be tested as per IS :10500-2012 : shall be Colour, Odour, tubidity, Ph value, Total dissolved solids, Aluminium, Ammonia, detergents, Barium, Boron, Calcium, Chlormines, Chloride, Copper Fluoride, Free Residual chlorine, Iron , Magnesium, Manganese , Mineral Oil, Nitrates, Silver, Sulphate, Sulphide.

45

-

-

... More
Comprehensive maintenace of granular chlorination plant including Decrin dozing pump, model No.96NGQ51 with high pressure single head motored adjustable dozing pump type agitator pump, dozing system complete including replacement of all unserviceable worn out spare parts required for smooth functioning of plant (supply of these parts shell be measured and paid separately, under respective items of this schedule) including testing of plant for satisfactory water tests complete all as specified and directed in following locations at Old Cantt, Allahabad:- 1. Installation at Pump House No.01 near EME Bn 2. Installation at Pump House No.02 near Abdul Hamid Gate 3. Installation at Pump House No.03 near Gun House 4. Installation at Pump House No.04 near PAC line 5. Installation at Pump House No.05 near Pawan Vihar 6. Installation at Pump House No.09 near CG line

9

-

-

... More
Contd/... 7. Installation at Pump House No.10 near NC line 8. Installation at Pump House No.13 at Triveni Vihar 9. Installation at Pump House No.14 at Div Camp near MT

-

-

-

... More
Comprehensive maintenance of liquid chloronome plant of capacity 6-12 ltr/hour, pulsar dia phragm type with high pressure dosing system i.e. vacuum operated pressure feed type / gravity feed type or any type or any make or any capacity including replacement of all unserviceable/ worn out spare parts including testing of plant for satisfactory water test complete all as spacified & directed , following locations at Old Cant Allahabad. 1. Installation at Pump House No.08 near Engineer Regt 2. Installation at Pump House No.11 near BTC Area 3. Installation at Pump House No.12 at Prayag Vihar NOTES :-(for item Sl No. 06 & 07 here-in-before) (i) Contractor shall carryout chlorine test at all installation daily and maintain chlorine test report & submit to Engineer-in-Charge all as spacified & directed. The unit rate quoted shall be deemed to include all the necessary test equipment/kit and charges for testing.

9

-

-

... More
Contd/… (ii) A bound maintenance register has to be maintained by the contractor indicating the spares replaced and to be countersigned by JE E/M & Engineer-in-Charge. (iii) In case contractor does not maintain the installation a sum of Rs.1000.00 per day per installation shell be recovered from contractor's due.

-

-

-

... More
Repair/Servicing of heavy duty chemical dosing system plunger type suitable to inject solutiion up to 25 LPH working pressure 10Kg/Cm2. Make : Sathya Sai Aqua Pura Services Cat No. SSAS/CDSPT/25. Note: Servicing to be carried out by authorised distributor or manufacturer of the said dosing system. A certificate to be produced in original form distributor /manufacturer after completion of specified work. Items/Spares required to make the system functional will be measured and paid separately as supply only as given below:-

10

-

-

... More
Supply only PVC Dosing head assembly with Suction and delivery adopter with NRV for above mentioned plant as specified at above.

10

-

-

... More
Supply only PVC NRV with glass ball for suction and delivery adopter for above mentioned plant as specified at above.

10

-

-

... More
Supply only PVC adopter for suction and delivery without NRv for above mentioned plant as spefigied at above.

10

-

-

... More
Supply only PVC stainer washer type heavy duty or Y type strainer for suction for above mentioned plant as specified at above.

10

-

-

... More
Supply only teflon gland square type 3 mm for above mentioned plant as specified at above.

10

-

-

... More
Supply only chemical Oil seal with cap for above mentioned plant as specified at above.

41

-

-

... More
Supply only dosing agitator gear box 25 LPH for above mentioned plant as specified at above.

1

-

-

... More
Supply only Plunger assembly without PVC dosing head 25 LPH for avbove mentioned plant as specified at above.

1

-

-

... More
Supply only Plunger assembly with Pvc dosing head 25 LPH for avbove mentioned plant as specified at above.

1

-

-

... More
Supply only Heavy duty FRP tank of capacity 150 litre for above mentioned plant as specified at above.

2

-

-

... More
Servicing of dosing agitator gear box by unscrewing foundation nuts & bolts, Strip oening of gear box & supply and replacing the worn out spares as given below and re-assembling the same after servicing/repair and fixing at site and testing on completing complete all as specified and directed :- (i)Chemical Oil Seal (ii)'O' ring (iii)Gear shifter (iv)Servicing of gears (v)Replacement og fear oil No. 460 (vi)Servicing of doser shifter Note: Servicing to be carried out by authorised distributor or manufacturer of the said dosing system. Acertificate to be produced in original from distributor / manufacturer after satisfactorily completion of specified works.

3

-

-

... More
Dismantling of unserviceable induction motor from the top on the chlorine tank and transporting it to authorised workshop for repair of capacity 0.5 HP, 3 phase, 415 V, 1440 RPM from pump Houses at vaious location/Yard in Cantt area and carrying out necessary repairs/renewal of parts of motor and refixing the same after repairs including testing on completing, complete all as specified and as directed.

5

-

-

... More
Cutting of existing burn/unserviceable winding, cleaning of slot, and re-winding of induction motor of any make with same size of super enamelled copper winding wire, varnishing , backing complete all as spedifeid and directed

5

-

-

... More
Water seal and packing complete all as specified and directed.

5

-

-

... More
Driven end bearing of pump shaft, complete all as specified and directed.

5

-

-

... More
Non driven end bearing of pump shaft, complete all as specified and directed.

5

-

-

... More
Cooling fan, complete all as specified and directed.

2

-

-

... More
Cooling fan cover, complete all as specified and directed.

2

-

-

... More
Connection plate, complete all as specified and directed.

2

-

-

... More
M & L for Unplasticised PVC pipe of pressure rating 10kg/Sq.cm fixed to wall/ceiling or in floors etc, of size 15 mm bore, complete all as specified and directed.

30

-

-

... More
Ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of size 15 mm bore dia, complete all as specified and directed.

7

-

-

... More
Servicing to chlorine dosing pump with electro chlorination batch type of capcity 230 litre in 8 hours comprising of storage tank, re-action tank, Electrolizer Cell, Electrode, Chemical resistance pump and wall mounted control panel, complete all as specified and directed. Make of plant : PristineWater Note : Servicing shell be carried out by authorised distributer or manufacturer of the said dosing system. A certificate to be produced in original from distributer/manufacturer after completion of spedifeid work. Items/Spares required to make the system functional will be measured and paid separartely as supply only items separartely work respective item of this schedule.

3

-

-

... More
Supply only SMPS (Switch Mode Power Supply) suitable for input range 100-120 AC supply at 17.5 Amp and 200-240 V AC at 10 A, 50Hz and out put at L.C. + 12 Volt at 83.3 Amps, Model No. SE-1000-12 of make- Mean well enterprises Co. Ltd or Techno Commercial or equivalent make as suitable for above supply, complete all as specified and directed.

1

-

-

... More
Supply only Electrolyzer Cell -100 GPH, complete all as specified and directed

1

-

-

... More
Supply only Reaction Tank 140 litre, complete all as specified and directed

1

-

-

... More
Supply only digital Timer, complete all as specified and directed.

1

-

-

... More
Supply only selector switch for Volt meter and ammeter, complete for above mentioned Chlorine dosing plant, complete all as specified and directed

4

-

-

... More
Supply only chlorine test kit with coloured ample, testing tube and OT soultion with rexene finish box, complete all as specified and directed. Make : T &C /Purichlor/Aquapura

12

-

-

... More
Supply only OT soluiton for testing of water sample, complete all as specified and directed. Make : T &C /Purichlor/Aquapura

4

-

-

... More
Dis-connection of submerssible pump set of any capacity from existing bore well system, disconnection of water supply & electric connection and taking out the unserviceable pump set from borewell with connected lowering pipe line of any size with mannual or suitable electric driven with chain pulley block upto 160 feet deep & re-assembling after neccessary repair and re-lowering the pump set in same borewell re-connection of electric & water connection for entire satisfaction of Engineer-in-Charge complete as directed. Note : Repair of U/S pump set will be paid separately. ii) All type of T/P required to complete the job will be arranged by contractor. iii) Job will be done round O-Clock continued as per site requirement as directed by Engineer-in-Charge. iv) Delay in job will be charged on the basis of Rs. 100/- per hour. v) Items required for motor connection such as PVC insulation tape, Valcanised rubber / puncture tube etc will be provided by the contractor to complete the work and rate as deemed to be quoted in unit rate no extra payment will be paid to the contractor.

12

-

-

... More
Material & Labour for cutting out the existing winding of submersible motor & satator of capacity 30/33HP any make and re-winding with the same size of copper winding wire as per existing gauge and number of turns (Coils) and necessary filling of varnish of best quality for proper insulation with entire satisfaction (contractor shall be done winding work at their workshops the cost of transportation of pump from site to workshop & back shall be included in quoted rate) as specified & directed by Engineer-in-Charge.

5

-

-

... More
Labour only for Straightening of the slots (any number) of stator of submersible motor of any make as directed by Engineer-in-charge.

3

-

-

... More
Supply & fixing thrust bearing block complete for submersible motor of any make as directed by Engineer-in-charge.

3

-

-

... More
Supply & fixing in repair of worn out gun metal bushes for submersible motor as per manufacturer's design and specification of required size as directed by Enginer-in-charge.

18

-

-

... More
Supply & Fixing in repair 3 core 6 Sqmm copper conductor submersible cable complete with suitable clips & lugs as specified & directed by Engineer-in-charge.

40

-

-

... More
Supply & fixing sand guard of submersible motor to match the existing size & capacity to prevent the sand protector of pump of same size & type complete all as specified and directed

3

-

-

... More
Supply & fixing sleeves of end plates of submersible motor to match the exisitng shape & size complete all as specified and directed

3

-

-

... More
Supply & fixing of cable grommet to match the existing size complete all as specified and directed

6

-

-

... More
Supply & fixing of water seal to prevant leakage of water complete all as specified and directed

3

-

-

... More
Supply & fixing of studs with nuts of required length & dia complete all as specified and directed

24

-

-

... More
M&L for shaft of submersible motor and filling or re-metalling of metal on shaft of motor, turning or grinding in lathe machine to bring it to original size and shape and polishing & fixing shaft on submersible motor complete as directed to entire satisfaction of Engineer-in-Charge.

2

-

-

... More
S&F coupling of submersible motor and pump with key complete all as specified and directed.

3

-

-

... More
Welding [Gas] of broken shaft and jointing of broken motor shaft with new piece, making key slot, grinding to make coupling size and balancing the rotor complete as specified & directed by Engineer-in-Charge.

2

-

-

... More
Complete over hauling of submersible pump by carrying out, balancing of pump shaft and cutting of key slots, repairs to bowl assembly, re-threading of worn out studs holes and proving suitaqble size studs with nuts complete as specified & directed by Engineer-in-Charge

3

-

-

... More
Supply & fixing of bowl bushes to match the same size & type for smooth functioning complete all as specified and directed

18

-

-

... More
Supply & fixing of neck ring of same size & type complete all as specified and directed

18

-

-

... More
Supply & fixing of steel distance pieces & key complete all as specified and directed

3

-

-

... More
Supply & fixing of impellor stainless steel / gun metal as per existing size & shape complete all as specified and directed

18

-

-

... More
Supply & fixing in repair of cast iron bowl for submersible pump to match the existing size & type complete all as specified and directed

18

-

-

... More
Supply & fixing in repair of cast iron non return valve of 80 mm bore pipe complete all as specified and directed

3

-

-

... More
Supply & fixing in repair of stainless steel pump shaft of submersible pump complete all as specified and directed

3

-

-

... More
Supply & fixing cast iron Head Extention complete all as specified and directed

3

-

-

... More
Supply & fixing of Cast Iron Inlet body of pump complete all as specified and directed

3

-

-

... More
Supply & fixing of Wedges of slots to match the exisitng slots complete all as specified and directed

3

-

-

... More
Taking out non clog sewage submersible pump including electric motor 7.5 HP, 3 phase ,415 Volts after disconnecting all electrical, transporting to workshop & mechanical connection including dismantling the motor and pump, cutting out the burnt/old/unservecible moulded winding and cleaning the slots with non greasy materials and replacing with moulded copper winding and repair of non clog pump by replacing with and including unserviceable parts such as bearing, bush, impeller mechanical seal suitable for non clog type submersible pump and filling new cooling oil 5 ltrs, reassembling after repair and lowering in the sewage well, reinstalling and testing complete all as directed by Engr-in-Charge. (Location- STP Akshay Vihar boosting station)

1

-

-

... More
Taking out mono block pump including electric motor 7.5 HP, 3 phase, 415 Volts after disconnecting the electric connection, transporting to workshop & dismantling the motor & cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with super enameled copper wire (Gauge of copper is to match the existing size) with insulating material, varnishing complete and repairing pump by replacing with and including unserveciable parts such as bearing, bush, impeller,gland packing& gland-I bolts etc reassembling after repair & reinstalling and making electrical and mechanical connections and testing complete all as directed by Engr-in-charge. (Location- STP Akshay Vihar)

2

-

-

... More
Disconnecting air compressor pump motor, transporting to workshop & taking out mono of capacity 7.5 HP, 3 phase, 415 Volts after disconnecting the electric connection & dismantling the motor & cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with super enameled copper wire (Gauge of copper is to match the existing size) with insulating material, varnishing complete and repairing pump by replacing with and including unserveciable buch/ bearing, etc reassembling after repair & reinstalling and making electrical and mechanical connections and testing complete all as directed by Engr-in-charge. (Location- STP Akshay Vihar)

2

-

-

... More
S&F in repair fan belt suitable for Air compressor 150 M³/hr including connection complete all as directed by Enginer- in- Charge.

2

-

-

... More
S&F in repair pressure gauge (water) range 0-4.20 Kg/Sq.cm complete all as directed by Engineer-in-Charge. Make: AE/KG/Ramco/ Guru

1

-

-

... More
Desludging of existing sewage collecting well of any size 3.7mtr dia and depth 6.0mtr & getting out sludge upto 2.0 mtr depth above the bottom surface through sucking supper soucer machine/ and depositing to a distance exceeding 1.5km but n. exc 2km out side MOD land at isolated places. (Location- STP Akshay Vihar) Note- Pumping out sludge water from sewage collection tank by using Diesel Engine operated pump and necessary diesel is to be arranged by contractor complete all as specified and directed by Engineer-in-charge .

25

-

-

... More
Desluding/cleaning of existing sludge drying beds of size 4.40mtr x 4.40mtr and depth 1.2 mtr by any means i.e manually or by mechanical appliances complete by removing the sludge /vegetation upto height of 0.5 mtr above the bottom surface, disposing sludge at abandonend place from Cantt area and deposited the same where directed by Engineer-in-Charge including supply & spreading of sand upto 150 mm thick on top of filter bed complete all as specified and directed by Engineer-in-charge . (Location- STP Akshay Vihar)

16

-

-

... More
Desluding/dewatering of existing equalizer tank of sewage treatment plant (size 4.8mtr x 4.8mtr x 2.5mtr depth) by any means ie mechanical appliances upto height of 1.3 mtr above the bottom surface complete, including working under foul condition and depositing or solid waste (silt) in any proportion and silted soil from the existing equalizer tank and removing the sludge to a distance not exceeding 2.0 Km in a sealed container out side of MOD land and deposited the same where directed by Engineer-in-Charge including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed.(Location- STP Akshay Vihar) Note : Pumping out sludge water from equaliser tank by using Diesel engine operated pump and necessary diesel is to be arranged by Contractor & included in unit quoted rates and not any claim entertained at later stage.

30

-

-

... More
Desluding/dewatering of existing tube settler tank of sewage treatment plant (size 3.4mtr x 2.4mtr x 2.7mtr) by any means ie mechanical appliances & through sucking super shocker machine upto 1.2 mtr above the bottom surface complete, including working under foul condition and depositing or solid waste (silt) in any proportion and silted soil from the existing settler tank and removing the sludge to a distance not exceeding 2.0 Km in a sealed container out side of MOD land and deposited the same where directed by Engineer-in-Charge including straining pvc media and cleaning with clean water and reuse for proper functioning complete including one coat of cement base paint on old plastrered surface after preparation of surface complete all as specified & directed. (Location- STP Akshay Vihar) Note : Pumping out sludge water from tube shetler tank by using Diesel engine operated pump and necessary diesel is to be arranged by Contractor & included in unit quoted rates and not any claim entertained at later stage.

20

-

-

... More
Desluding/dewatering of existing chlorine contact tank of sewage treatment plant (Each of size 3.40mtr x 2.5mtr x 1.5mtr) and getting out sludge through sucking super shocker machine upto height 0.5mtr above the bottom surface and removing the sludge to a distance not exceeding 2.0 Km in a sealed container out side of MOD land and deposited the same where directed by Engineer-in-Charge including straining pvc media and cleaning with clean water and reuse for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface complete all as specified & directed. (Location- STP EME Line)

10

-

-

... More
Desludging/dewatering of existing TWT tank of sewage treatment plant (Size 5.0mtr x 3.4mtr and depth 1.8mtr) and getting out sludge through sucking super shocker machine upto height 0.2 mtr and depositing to a distance exceeding 1.5 km but not exceeding 2 km outside MOD land at isolated place. Brooming/scraping down of old surface of the tank with bleaching powder and cleaning with clean water and re-use for proper functioning complete including one coat of cement base paint on old plastered surface after preparation of surface proper functioning complete all as specified & directed. (Location- STP Akshay Vihar) Note- pumping out sludge water from TWT tank by using Diesel Engine operated pump and necessary diesel is to be arranged by Contractor all as specified and directed by Engineer-in-charge and not any claim entertained at later stage.

12

-

-

... More
Desluding/dewatering of existing MBBR tank of sewage treatment plant (size 1.9mtr x 1.9mtr and depth 5.0 m) by any means ie mechanical appliances upto height of 1.5 mtr above the bottom level complete including working under foul condition and depositing or solid waste (silt) in any proportion and silted soil from the existing equalizer tank and removing the sludge to a distance not exceeding 2.0 Km in a sealed container out side of MOD land and deposited the same where directed by Engineer-in-Charge including one coat of cement base paint on old plastrered surface after preparation of surface complete all as specified & directed. (Location- STP Akshay Vihar) Note : Pumping out sludge water from MBBR tank by using Diesel engine operated pump and necessary diesel is to be arranged by Contractor & included in unit quoted rates and not any claim entertained at later stage.

15

-

-

... More
M&L for preparation of old painted surfaces of steel surfaces such as sheets, filters, compressor, pipelines, mild steel ladders, Column pipes any size of STP, over 10cm width or girth and applying one coat of synnthetic enamel paint complete all as specified and directed. (Location - STP Akshay Vihar)

15

-

-

... More
S&F in replacement , connecting, testing and commissioning Direct Online Starter with single phase protection, max relay range 11-18 Amp suitable for 7.5 HP, 3 Phase, 415 volts, 50 HZ, having all standared accessories complete all as specified and directed. MAKE: Shneider/ L&T/ Legrand/ Standard.

3

-

-

... More
Taking out existing filter media from sludge drying bed and Supply & replacement of filter media (coarse sand) of sludge drying bed as per existing size complete all as specified and as directed at STP Akshay Vihar.

20

-

-

... More
Supply and Mixing Calcium based granular disinfectant for water treat ment drinking water with 60 70 % chlorine contents by volume conforming to IS-15738 in sealed plastic containers of 45 kg , as required on monthly basis with manufacturer's chlorine test certificate and manufacturer's date marked not more than 02 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (Calcium granular) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.

2925

-

-

... More
Supply and Mixing liquid chlorine sodium hypochlorite drinking water with 10% chlorine contents by volume conforming to IS-11673 in sealed non-chemical reactine/ oxidation LDPE continers of 6 kg PVC tanks, as required on monthly basis with manufacturer's chlorine test certificate and manufacturer's date marked not more than 02 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (sodium hypochlorite) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.

2000

-

-

... More
Supply and Mixing TCCA-90 disinfectant for water treat ment drinking water with 90% chlorine contents by volume conforming to IS-15773 in sealed plastic containers of 50 kg , as required on monthly basis with manufacturer's chlorine test certificate and manufacturer's date marked not more than 02 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (Calcium granular) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.

4400

-

-

... More
Supply and Mixing Bleaching Powder disinfectant for water treat ment drinking water with 33- 35 % chlorine contents by volume conforming to IS- 15738 in sealed plastic containers of 25 kg , as required on monthly basis with manufacturer's test certificate and manufacturer's date marked not more than 03 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.

1000

-

-

... More
Supply and Mixing Poly Ferric Aluminium Chloride disinfectant for water treat ment swimming pool /STP water with 5 % chlorine contents by volume conforming to IS- 1113 in HDPE Bag of 25 kg , as required on monthly basis with manufacturer's test certificate and manufacturer's date marked not more than 03 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (Ferric Aluminium Chloride) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of Ferric Aluminium Chloride (ii) The brand/make of the Ferric Aluminium Chloride of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of Ferric Aluminium Chloride is suitable for swimming pool water and its sample has been tested by Govt Laboratory.

75

-

-

... More
Supply and Mixing Soda Ash for water treat ment r with 99% Sodium carbonate contents by volume conforming to IS-251 in HDPE bag of 50 kg , as required on monthly basis with manufacturer's test certificate and manufacturer's date marked not more than 03 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical (Calcium granular) shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of chlorination (ii) The brand/make of the chlorination of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for drinking water applications for consumption by humans and the brand /make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.

100

-

-

... More
Supply and Mixing HCL ( Hydrochloric Acid) for water treat ment swimming pool water with 30 % Acidity contents by volume conforming to IS- 265 in sealed plastic containers of 55 kg , as required on monthly basis with manufacturer's test certificate and manufacturer's date marked not more than 03 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of HCL (ii) The brand/make of the HCL of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for swimming pool water applications for consumption by humans and the brand /make of HCL is suitable for swimming pool water and its sample has been tested by Govt Laboratory.

400

-

-

... More
Supply and Mixing Copper sulphate crystal for water treat ment swimming pool water with contents by volume conforming to IS- 261 in sealed HDPE Bag of 25-50 kg , as required on monthly basis with manufacturer's test certificate and manufacturer's date marked not more than 03 week old , complete all as specified and directed. NOTES:- (i) Approval of chemical shall be given after verification of test certificates of chemical of various manufactures and other factors like chemical and safety and health hazard aspects of usage of Copper sulphate (ii) The brand/make of the Copper Sulphate of chemical must be stated before procurement and certified by govt laboratory that it is free from the technical strength stahbility health safety and operation point of view this product is ued for swimming pool water applications by humans and the brand /make of Copper Sulphate is suitable for swimming pool water and its sample has been tested by Govt Laboratory.

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.