Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Housekeeping Services
Eprocure
Opening Date10 Oct 2020
Closing Date20 Oct 2020
Tender Amount₹ 21,33,449 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
8120/saer-17/e8 Manning And Operation Of Dg Set, Ac Plant And Water Supply Installation Etc At 1afsb Dehradun Under Ge (af) Sarsawa
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_360073_3Bid Award Id
ViewTender No
8120/SAR-17/E8 OUT SOURCING MANNING AND OPERATIONTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
MANNING AND OPERATION OF DG SET, AC PLANT AND WATER SUPPLY INSTALLATION ETC AT 1AFSB DEHRADUN UNDER GE (AF) SARSAWA
MANNING AND OPERATION OF DG SET, AC PLANT AND WATER SUPPLY INSTALLATION ETC AT 1AFSB DEHRADUN UNDER GE (AF) SARSAWA
MANNING AND OPERATION OF DG SET, AC PLANT AND WATER SUPPLY INSTALLATION ETC AT 1AFSB DEHRADUN UNDER GE (AF) SARSAWA
BOQ Items
... More
Manning, maintenance and operation of DG sets in THREE SHIFTS from 0600 hrs to 1400 hrs and 1400 hrs to 2200 and 2200-0600 hrs including Sunday and gazetted holiday with one operator consisting of the following :-
(a) DG Set 75 KVA, 15 KVA , 50 KVA & 200 KVA
(b) LT Panels
(c) Change over switch
(d) Batteries Shifts timing : 1st Shifts 0600 hrs to1400 hrs .2nd shift 1400hrs to 2200hrs and 3rd shift 2200 hrs to 0600 hrs. Operating Staff required = ONE Operator (FGM) Fitter Genaral Mechanic (semi skilled) per shift, Shifts required = Three shift of 08 hours daily including Sunday & Holiday. Note(i) Life Insurance for all the personnel shall be ensured by the contractor . (The contractor shall be provide minimum 3 lakh accidental medical claim and minimum 10 lakhs life insurance coverage during contract period.) (ii) Minimum T&P Required for the Operator to be provided by Contractor. (iii) All safety Device required of the Operator to be provided by Contractor. (iv) Any damages to the machinary/Operater occured due to miss handling of Equipmet will be compensated by Contractor.
-
-
-
... More
((v) Minimum Wages to be paid by Contractor Through nationalised Bank ECS mode as per Labour Commission Act.
(vi) Minimum qualification of the Operator is Xth passed with minimum 6 years experiance as pump operater/Govt / Govt approved ITI or equivalent before deployment of Operators,qualification Certificate of individule to be Provided & got varified. (vii) Weekly off as per Lobour act to be given to the Operator& reliever to be Provided by the Contractor at no Extra Cost.
(viii) POL required for DG Set shall be collected by the operator from the Department Store.
(ix) Contrator has to Provided 02 pair of Over all Combination (as approved by Department) to each Operator.
(x) In case of absenteeism of any Operator/Helper in a Shift/Duty,double the amount of Shifts is recovered from the Contractor.
(xi) After Complition of work Contractor shall return all the temporary passes to AF authorities and certificate to obtained & the same be enclosed with Finel Bill.
(xii) Contractor shall obtain a Affidavit from all deployed Operators/Trademen/Helpers that they are deployed temporary by the Contractor for 11 months through Outsourcing & They have no legal binding/with department regarding/employmenty/parmanent or any other compensation due to accident/break of jobs. (xiii) Cost of cotton rags for daily maintenance of equipment shall be deemed in quoted rates.
-
-
-
... More
Semi skilled Tradesman / FGM- 01 Nos
819
-
-
... More
Repair and maint of external electric supply , HT/LT distribution system and attend & rectify daily complaints at 1 AFSB complex Dehradun as specified and directed in THREE SHIFTS from 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs including Sunday and gazetted holidays by providing one team consisting of following :- Shifts timing : 1st Shifts 0600 hrs to1400 hrs Operating Staff required = ONE ELECTRICIAN (skilled) AND ONE HELPER (Un skilled) per shift, Shifts required = Three shift of 08 hours daily including Sunday & Holiday. Note(i) Life Insurance for all the personnel shall be ensured by the contractor . (The contractor shall be provide minimum 3 lakh accidental medical claim and minimum 10 lakhs life insurance coverage during contract period.) (ii) Minimum T&P Required for the Operator to be provided by Contractor. (iii) All safety Device required of the Operator to be provided by Contractor. (iv) Any damages to the machinary/Operater occured due to miss handling of Equipmet will be compensated by Contractor.
-
-
-
... More
(v) Minimum Wages to be paid by Contractor Through nationalised Bank ECS mode as per Labour Commission Act.
(vi) Minimum qualification of the Operator is Xth passed with minimum 6 years experiance as pump operater/Govt / Govt approved ITI or equivalent before deployment of Operators,qualification Certificate of individule to be Provided & got varified. (vii) Weekly off as per Lobour act to be given to the Operator& reliever to be Provided by the Contractor at no Extra Cost.
(viii) POL required for DG Set shall be collected by the operator from the Department store.
(ix) Contrator has to Provided 02 pair of Over all Combination (as approved by Department) to each Operator.
(x) In case of absenteeism of any Operator/Helper in a Shift/Duty,double the amount of Shifts is recovered from the Contractor.
(xi) After Complition of work Contractor shall return all the temporary passes to AF authorities and certificate to obtained & the same be enclosed with Finel Bill.
(xii) Contractor shall obtain a Affidavit from all deployed Operators/Trademen/Helpers that they are deployed temporary by the Contractor for 11 months through Outsourcing & They have no legal binding/with department regarding/employmenty/parmanent or any other compensation due to accident/break of jobs. (xiii) Cost of cotton rags for daily maintenance of equipment shall be deemed in quoted rates.
-
-
-
... More
Skilled Tradesman / Electrician- 01 Nos
819
-
-
... More
Unskilled Tradesman / Helper- 01 Nos
819
-
-
... More
BOQ PART II Supply and fix only Battary 12 volt 120 AH DG Set operation complete all as specefied and as directed byn engr- in- charge of Make (EXIDE/PRESTOLITE/AMRON/LUMINOUS )
2
-
-
... More
Supply only Battary 12 volt 150 AH DG Set operation complete all as specefied and as directed byn engr- in- charge of Make (EXIDE/PRESTOLITE/AMRON/LUMINOUS )
3
-
-
... More
Supply and fix power contactor ML 6, 3 pole 415 volt,110 Amps AC3, 50Hz complete all as specefied and as directed byn engr- in- charge Make L&T/C&S/ siemens
4
-
-
... More
Supply,installing,commisioning and testing of feeder protection relay having over current and earth fault protection compatible to RMU and scada with microprocessor type REJ 603 of ABB for HT 33/11 KV .complete all as specified and directed Make : ABB,Schnider,Adhisha
5
-
-
... More
Supply,installing,commisioning and testing of RMU battery charger out put 24 volt DC,5 A input volt 88-265 V AC with 2 nos of 24 Volt Dry battery compatible to RMU of ABB for HT 33/11 KV .complete all as specified and directed Make : Amaron,Luminous,Exide
2
-
-
... More
Supply, installing,commisioning and testing automatic voltage regulator (AVR) compatible to Dg set 15 kva to 200 Kva complete all as specified and directed.
2
-
-
... More
M&L in replacement for jointing and testing cable jointing kit for 11 KV grade cable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 -185 sqmm complete all as specified and as directed.
2
-
-
... More
M&L in replacement for jointing and testing cable jointing kit for 11 KV grade cable outdoor termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 70-120 sqmm complete all as specified and as directed.
2
-
-
... More
Supply only earth discharge rod compatible for 33/11KV complete all as specified and directed
2
-
-
... More
Supply only hand gloves compatible for 33/11 KV.complete all as specified and directed
2
-
-
... More
Supply only LED search light 100 w with minimum 2 years warranty complete all as specified and directed
2
-
-
... More
Supply only Rain coat compatible for heavy rain and snow fall complete all as aspecified and directed
10
-
-
... More
Supply only fuse wire compatible for 33/11 KV .complete all as specified and directed
1
-
-
... More
Supply only Lugs compatible for 10 sqmm to 240 sqmm cable.complete all as specified and directed
(a) 10Sqmm - 30
(b) 16 Sqmm- 30
© 25Sqmm - 30
(d ) 35 sqmm -50
(e) 50 sqmm - 50
(f) 70 sqmm - 30
(g) 95 Sqmm - 20
(h) 120 Sqmm- 20
(j) 185 sqmm - 20
(k) 240 Sqmm- 20
300
-
-
... More
Supply only spin on filter for lubricating oil cat part no. 06.436.01.0.00 complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply only primary element cat part no. 3H.132.01.0.00 complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply only secondary element cat part no. 3H.132.02.0.00 complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply only K oil super 15 W 40 suitable for kirloskar DG Set complete all as specefied and as directed byn engr- in- charge
100
-
-
... More
Supply only K cool Super plus 50-50 premix cat part no.82.020.35.1.25 complete all as specefied and as directed byn engr- in- charge
100
-
-
... More
supply only V fan belt for alternator of capacity 50 to 200 KVA DG Set complete all as specefied and as directed byn engr- in- charge
10
-
-
... More
Supply only of primary and secondary air filter suitable for 50 to 200 KVA DG Set complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply and replacement of secondary fuel fillter of generator 50 KVA to 200 KVA complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply and replacement of primary fuel filter of generatior 50 KVA to 200 KVA complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
Supply and replacment of oil filter of generator 50 KVA to 200 KVA complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
spply and fix fuel pipe compatible for 15 kva to 200 kva DG set complete all as specefied and as directed byn engr- in- charge
6
-
-
... More
supply only tape insulation 25 mm width 25 mtr legth complete all as specefied and as directed byn engr- in- charge
100
-
-
... More
M&L in replacement for jointing and testing cable jointing kit for 1.1 KV grade cable straight through heat shrinkable joint complete with jointing material and accessories suitable for 4 core XLPE, armoured, aluminium conductor cable of size 10 -240 sqmm complete all as specified and as directed.
10
-
-
... More
Supply and fixing in replacement of MCCB Triple Pole 400 Amp 415 Volt rupturing capacity not less than 36 KA complete all as specified and as directed. MAKE : Indoasian/HAVELLS/LEGRAND/SIEMENS/L&T.
2
-
-
... More
Supply and fixing in replacement of MCCB Triple Pole 250 Amp 415 Volt rupturing capacity not less than 36 KA complete all as specified and as directed. MAKE : Indoasian/HAVELLS/LEGRAND/SIEMENS/L&T.
2
-
-
... More
Supply and fixing in replacement of MCCB Triple Pole 200 Amp 415 Volt rupturing capacity not less than 36 KA complete all as specified and as directed. MAKE : Indoasian/HAVELLS/LEGRAND/SIEMENS/L&T.
2
-
-
... More
Supply and fixing & replacement of LED Street light fitting 72 W, 8000-9000 lumens,5700K, 110lm/watt with IP 65/66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass/PolyCarbonate, LED lenses, surge protector, BIS electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 40 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, etc complete all as directed. Make : Philips BRP062 LED 84 CW SLC S1 PSU, Crompton LSTP-72-CDL, Havells ENDURAPEARLPLUSSL70WLED757PASYTOPC
8
-
-
... More
Supply, installation, commissioning and testing of Advance Manitenance Free environment friendly ring earthing system. Each set consisting of 3 Nos of 6 feet length, 17 mm dia earth electrode made of high tensile low carbon steel circular rods, molecularly bonded cooper on outer surface ( minimum copper bonding thickness - 250 microns) with terminals to connect incoming strip with 3 bags (25 Kg each ) of environment friendly backfill compound as per manufacturing instructions with ROHs test certificate for each 150 x 25 x 6 mm Copper Bar with 4 hole shall be exothermically welded ontop to copper bonded rod to make terminal laid in minimum 80 mm dia bore. Manufacturer name shall be embossed on rod. 25 x 3 mm copper shall be used to interconnected the earths and to make the ring. The earth pit cover polypropeline (300 mm x 300 mm) shall be included in the scope of work. Make: OBO/JEF ECO SAFE/ENNOV
Note: (i) Earthing shall be tested after completion of work by contractor in presence of Engr-in-Charge and proper record shall be maintained duly signed by all concerned. On testing if the desired earth resistance of less than 1.0 Ohm is not obtained the earthing will be redone at no extra cost to Govt.
(ii) The cooper strip from test point to euipment or entire earting system to Eqpt/bldg only shall be measured and paid under relevant item.
6
-
-
... More
Supply and fix in repair and replace GI nut bolt compatible for earthing strips and connections. Complete all as specified and directed
10
-
-
... More
Supply and fix in repair and replace insulators compatible for earthing strips and connections. Complete all as specified and directed
200
-
-
... More
Supply and fixing in replacement of chlorine gas cylinder with chloronom system compatible for existing system.complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?