Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Nov 2024
Closing Soon20 Nov 2024
Tender Amount₹ 19,59,900 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.

82.62

-

-

... More
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engineer-in-Charge.

8160

-

-

... More
Taking Out Old and Unserviceable XLPE Cable any size(300sqmm 3.5core /240/120/95/70/25/16/ 10/6sqmm4core/3.5 core) from trenches,pole,road,duct etc incl necessary joint Etc complet all as specified and directed.

1000

-

-

... More
S&F in replacement of LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size .

-

-

-

... More
300sqmm3.5 core XLPE Cable

200

-

-

... More
120sqmm3.5 core XLPE Cable

100

-

-

... More
95Sqmm3.5 core XLPE Cable

100

-

-

... More
70Sqmm3.5 core XLPE Cable

100

-

-

... More
35Sqmm3.5 core XLPE Cable

100

-

-

... More
25 Sqmm 4 Core XLPE Cable

200

-

-

... More
10sqmm 4 core XLPE Cable

200

-

-

... More
Supply and fix aluminium lugs for fixing armoured cable in panel of following sizes taking down old one .

-

-

-

... More
from 10 to 16 sqmm 4 core cable

50

-

-

... More
from 25 to 35 sqmm 4 core cable

50

-

-

... More
from 50 to 70 sqmm 3.5 core cable

50

-

-

... More
from 95 to 120 sqmm 3.5 core cable

30

-

-

... More
from 150 to 185 sqmm 3.5 core cable

20

-

-

... More
from 240 to 300 sqmm 3.5 core cable

20

-

-

... More
Taking out old LT U/G cable of size 16 to 300Sqmm from trench and relaying LT cable after repair in trench (Note:-Excavation and other related items will be measured and paid separately)

160

-

-

... More
Supply and fix cable jointing kit for 1.1KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes :

-

-

-

... More
from 25 to 50sqmm cable

15

-

-

... More
from 70 to 95sqmm cable

15

-

-

... More
from 120 to 150sqmm cable

10

-

-

... More
from 185 to 300sqmm cable

5

-

-

... More
M&L for machine spray painting of LT Panels by rubbing, scraping of old paints with emery paper, cleaning and preparation of smooth surfaces complete with approved quality paint all as specified and directed by Engineer – in – Charge.

30

-

-

... More
Taking out theU/S MCCB of any make and capacity all as specified and directed

27

-

-

... More
M&L MCCB 250 amp 415Volts 4 Pole 36 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed and .taking down old one.

6

-

-

... More
M&L MCCB 400 amp 415Volts 4 Pole 36 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed.

2

-

-

... More
M&L MCCB 125 amp 415Volts 4 Pole 16 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed and taking down old one.

4

-

-

... More
M&L MCCB 100 amp 415Volts 4 Pole 16 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed.and .taking down old one.

8

-

-

... More
M&L MCCB 200 amp 415Volts 4 Pole 36 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed.and .taking down old one.

2

-

-

... More
M&L MCCB 63 amp 415Volts 4 Pole 16 KA With Thermal adjutment and magnetic setting complete with sheet steel enclosure and fixing on Exiting PANEL all as required with nut bolts complete all as specified and directed.and .taking down old one.

5

-

-

... More
Taking out the U/S Change over switch of any make and capacity all as specified and directed

6

-

-

... More
M&L Change over switch ON Load type Front Handle Operated 63Amp pole 415 Volts 4 Pole confirming to IS 13947-3 insheet steel enclosure fixing with all as required with nut bolts comlete all as specified and directed, Cat No ITASOO63 of indoasian or euivalent to havells/HPL/C&G

1

-

-

... More
M&L Change over switch ONLoad type Front Handle Operated 100Amp pole 415 Volts 4 Pole confirming to IS 13947-3 insheet steel enclosure fixing with all as required with nut bolts comlete all as specified and directed.Cat No.ITASO100 of indoasian or euivalent to havells/HPL/C&G

2

-

-

... More
.M&L Change over switch ON Load type Front Handle Operated 200Amp pole 415 Volts 4 Pole confirming to IS 13947-3 insheet steel enclosure fixing with all as required with nut bolts comlete all as specified and directed.Cat No.ITASO100 of indoasian of Standard or euivalent to havells/HPL/C&G

2

-

-

... More
.M&L Change over switch ON Load type Front Handle Operated 630 Amp pole 415 Volts 4 Pole confirming to IS 13947-3 insheet steel enclosure fixing with all as required with nut bolts comlete all as specified and directed.

1

-

-

... More
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron strip 32x6 mm by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.5 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with CI cover of appropriate size with 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work complete all as specified and directed by Engr- in- Chanrge

10

-

-

... More
S&F Indicator lamp LED Type Red,Yellow,Blue including fixing of exting panel and taking out old one

5

-

-

... More
S&F digital Voltmeter 0-600Volts,including fixing of exting panel and taking out old one Make-AE/L&T

5

-

-

... More
S&F digital Ameter 0-400Amps ,including fixing of exting panel and taking out old one Make-AE/L&T

5

-

-

... More
S&F Selector Switch (Three Phase )including fixing of exting panel and taking out old one.Make-AE/L&T

5

-

-

... More
S&F Current Transformer Ratio 100/5 A ,240 Volt AC indoor tape insulated ring type LT Current Transformer and including connecting wire and connected with panel busbar comleted as per EIC.

5

-

-

... More
M&L for GI pipe (light grade) with all fittings laid in trenches/wall complete for protection UG cable when crossing the road of size 80 mm bore.

40

-

-

... More
Replacement of LED Garden Light 9 watt and replacement the diffective part i.e holder/diode /CFL LED including all accessories and repair of u/s Wire any size connected to garden light all as specifed and directed .

20

-

-

... More
S&F in replacement of New LED Bollard light(Garden Light) 9 Watt,single phase,240 Volts with 9 watt LED lamp opal diffuser & aluminium reflector .

20

-

-

... More
Supply and fix in replacement of Intergral LED Post-Top Luminaire 40 W Comprises housing with LEDs and driver. Glare-free and better uniformity and Heat resistant toughened glass with frame suitably gasketed for IP 65 Class I protection including all accessories, all as specified and directed.

10

-

-

... More
Supply only Transformer oil of approved quality as per IS having dielectric strength of 40-70 kv in 2.5 mm gap for filling in transformer or for toping up all as directed and specified make:Power Oil in a sealed container .

200

-

-

... More
Dehydration /filteration of transformer oil by means of centrifugal filteration plant to achieved the specified dielectric strength upto 60 kv at 2.50 mm gap in existing possesion of transformer of any capacity and transformer oil for toping up at various sub station all as directed by Engr in charge

500

-

-

... More
Servicing of 33 KVA VCB ,current transformer ,control relay panel, remote ON/OFF of control panel ,repair of battery charger of control panel ,repair of DC motor of VCB with including wiring and related other works.

1

-

-

... More
M&L for disconnecting burnt end or portion of 10 sq mm to 185 Sq mm 3 1/2 core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and realaying the same, and reconnecting the cable by removing burnt protion of cable and preparing fresh terminals of LT cable to pole / main switch etc complete all as specified.

20

-

-

... More
Supply and fixing factory made epoxy powder coated distribution board double door TP & N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including one FP MCCB/MCB 100/ 63 Amps as incomer and 24 nos MCBs (or any combination of SP/TP MCBs) outgoings complete all as specified & directed.

4

-

-

... More
Supply and laying weather proof cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections.

200

-

-

... More
M&L for in replacement of compact air insulated with inclosure of rising main with aluminium bus bar 125 Amps, breaking capacity of 35 KA and IP-54 protection complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
M&L for replacement of LT Cubicle panel of suitable size, indoor type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 1.6 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts , springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz , 3 phase 4 wire system 1100 volts grade, coloured heat shrinkable sleaving, internal connection should be provided with aluminium strip of suitable size and necessary grouting/ foundation all as required at site and comprising following:-:-

1

-

-

... More
(a) Ammeter, digital including selector switch. (b) CT of required capacity -03 No. (c) Voltmeter Digital type . (d) Phase indicating lamps -03 Nos (e) Control wiring (f) Copper conductor wiring . (g) BusBar strip made out of Aluminium of 400 amps capacity mounted on insulators. (h) MCCB 4 Pole 415 Volt 250 Amps Capacity, 36 KA - 01 Nos ( Incoming ) . (j) MCCB 3 Pole 415 Volt 160 Amps Capacity, 36 KA - 03 Nos ( for outgoing ). (k) MCCB 3 Pole 415 Volt 125 Amps Capacity, 36 KA - 01 Nos ( for outgoing ).

-

-

-

... More
Repair/maintenance and servicing of step down transformer 33 KV/433 Volt of capacity 630KVA installed at GRD comprising following work services :- (a) Disconnection carefully of cable end termination of HT & LT side. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (c) Draining out transformer oil and keeping aside in barrel for re-use and then again pouring back after necessary filteration and dehydration including top up with new transformer oil to make up the reduced quantity. (d) Replacement of top gaskets. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points.

1

-

-

... More
(f) Labour only for cleaning of bush and stud both HT/LT side and refixing the same with new cock sheet as required. (g) Replacing unserviceable stud and bush as required as directed by Engr-in-Charge. (h) Reconnection of all cable terminals HV & LV sides and refixing the top cover after replacement of gaskets, conservator tank in position. (i) Cleaning and heating of silica gel in breather and replacing with new silica gel to make up the reduced quantity. (j) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead. Note :(i) Spare parts (if required) will be measured and paid separately. (ii) New transformer oil (if required for topping up) will be measured and paid separately. (iii) De-hydration of existing transformer oil for refilling will be measured and paid separately.

-

-

-

... More
Supply only bushing and stud complete with porcelain insulators and gasket complete for LT side (as per existing size/Model) for 630KVA capacity of transformer.

3

-

-

... More
Supply only bushing and stud complete with porcelain insulator and gasket complete for HT side (as per existng size/Model) for 630KVA capacity of transformer.

3

-

-

... More
Supply only new silica gel in the breather complete all as specified and directed.

2

-

-

... More
M&L for replacement of Danger Notice plate of 1:6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and convenbtional shull and bones in signal red colour and fixed with MS clamp, bolts and nuts of appropriate size of HT sign 25x20 cm size 05 Nos and LT sign 20x15 cm size 05 Nos

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.