Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665920_1Bid Award Id
ViewTender No
8203/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
All as per Item Ser No 1 here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB
2
-
-
... More
S & F in repair selector switch 3 way for checking of Amps in 3 phase at different position in existing panels complete all as specified and directed by Engr-in-charge .
3
-
-
... More
S & F in repair of Multifunctional meter with all acccessories ie CT etc for measuring Volt, Amps, frequency and power factor digital type and fixing the same in existing panel by modification to existing space of volt meter/Ameter by cutting welding and cover the blank space by existing colour MS sheet and making good to disturbed surface complete all as specified and directed.
2
-
-
... More
Supply and installing commissioning and testing cubical type LT Panel outdoor type of 1.50 x 1.40 x 0.60 mtr CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick MS sheet including two coats of synthetic enameled paint over a coat of primer red oxide and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement including taking out old LT Panel from existing site as directed before manufacturing the panel. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-
2
-
-
... More
Incoming :- (i) Insulated epoxy coated high conductivity aluminium bus bar 800 Amps of suitable size for phase and neutral complete all as specified and directed. (ii) On Load Change Over switch three phase 4 pole of capacity 400 Amp-01
(iii) MCCB 400 Amp 36 KA, 4 pole, 415 volts 50 Hz – 01 No (iv) Digital type Volt meter (0-500) volts with selector switches. (v) Digital Amp meter with suitable resin cast CT and selector switch – 01 (At main out going) (vi) LED Indicating lamp assembly R,Y,B Phase – 03 Set
Outgoing :-
(i) MCCB 250 Amp 36KA, 4 pole, 415 volts 50 Hz- 01 Nos (ii) MCCB 100 Amps 16 KA, 4 pole 415 Volt 50Hz - 04 No
-
-
-
... More
Supply and installing commissioning and testing cubical type LT Panel outdoor type of 1.50 x 1.40 x 0.60 mtr CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick MS sheet including two coats of synthetic enameled paint over a coat of primer red oxide and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement including taking out old LT Panel from existing site as directed before manufacturing the panel. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-
1
-
-
... More
Incoming :- (i) Insulated epoxy coated high conductivity aluminium bus bar 800 Amps of suitable size for phase and neutral complete all as specified and directed. (ii) MCCB 500 Amp 36 KA, 4 pole, 415 volts 50 Hz – 01 No (iii) Digital type Volt meter (0-500) volts with selector switches. (iv) Digital Amp meter with suitable resin cast CT and selector switch – 01 (At main out going) (v) LED Indicating lamp assembly R,Y,B Phase – 03 Set
Outgoing :-
(i) MCCB 250 Amp 25KA, 4 pole, 415 volts 50 Hz – 02 Nos
(ii) MCCB 200 Amp 25 KA 4 pole 415 Volts - 50Hz - 02 No
-
-
-
... More
M&L for preparing old painted surface of LT Panel board indoor/outdoor type of any size by cleaning removing of the old paint by scraping with wire brush/sand paper etc and including minor repair to panel in different location where required with arc/gas welding with replacement of hinges and place the door in original position denting/patching of broken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting on inside/ outside surface of panel,all as specified and directed by Engr-in- charge.
160
-
-
... More
S&F in repair MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA alongwith spreader terminal with adjustable thermal & magnetic setting setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge. :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
4
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 500 Amps 4 pole 50 Hz 415 V, 50 KA
2
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 400 Amps 4 pole 50 Hz 415 V, 36 KA
8
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 250 Amps 4 pole 50 Hz 415 V, 36 KA
10
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 200 Amps 4 pole 50 Hz 415 V, 36 KA
7
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 160 Amps 4 pole 50 Hz 415 V, 36 KA
4
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 125 Amps 4 pole 50 Hz 415 V, 16 KA
2
-
-
... More
All as per Item Ser No 12 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 16 KA
1
-
-
... More
S&F in replacement Isolator 4 pole 100 Amps, 415 Volts complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
All as per Item Ser No 19 here-in-before but 63 Amps, complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
M& L for repair and over hauling to LT ACB up to 2000 Amp cap by removing out the panels after taking proper electric shut down & disconnectingthe breaker ,checking if throughly for the defect & triping system of the ACB and ractifying them ,lubricating of moving contact /overhauling af ACB,replacement of wornout minor spare part,like spring washer,lever,nuts 7 bolts etc reaasembling ,re-istalling ,testing and commissioning of ACB complete all as direcred by Engr-in- Charge.
8
-
-
... More
Supply and fixing and moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply and fixing of fixed Arcing contact nand adjust the contact pressure of LT ACB of any make any capacity. complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
M & L for replacement of main shaft assembly with crank & cam spacer of 1250/1000/800 Amps 3 Pole of LT ACB of existing make & model and testiing for proper operation complete all as directed by Engineer-in-Charge.
4
-
-
... More
M & L for replacement of racking mechanism t assembly with all connected accessories of 1250/1000/800 Amps 3 Pole of LT ACB of existing make & model and testiing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
M & L for replacement of operating mechanism assembly with all connected accessories of 1250/1000/800 Amps 3 Pole of LT ACB of existing make & model and testiing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
M & L for replacement of closing coil suitable for LT ACB of 1250/1000/800 Amps 3 Pole of existing make & model and testiing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
M & L for replacement of Tripping coil suitable for LT ACB of 1250/1000/800 Amps 3 Pole of existing make & model and testiing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
M & L for replacement of protection relay for ACB operating system as per existing make and Model incl all connected items as reqd to functioning LT ACB of Cap 2000/1000/800 Amps 3 Pole and testiing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
M & L for replacement of spring charging gear motor for LT ACB breaker of size 2000/1000/ 800 Amps of existing make & Model and testing for proper operation complete all as directed by Engineer-in-Charge.
3
-
-
... More
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed.
874.8
-
-
... More
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
558.01
-
-
... More
Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed.
316.79
-
-
... More
Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables and store for relaying complete all as specified & directed. Note : Excavation and earth work will be paid and measured separately in relevant item.
4050
-
-
... More
Supply and laying of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 240 Sq mm 3.5 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
300
-
-
... More
All as per Ser item No 36 here-in-before but 185 Sq mm 3.5 core
450
-
-
... More
All as per Ser item No 36 here-in-before but 150 Sq mm 3.5 core
100
-
-
... More
All as per Ser item No 36 here-in-before but 120 Sq mm 3.5 core
500
-
-
... More
All as per Ser item No 36 here-in-before but 95 Sq mm 3.5 core
800
-
-
... More
All as per Ser item No 36 here-in-before but 50 Sq mm 3.5 core .
200
-
-
... More
All as per Ser item No 36 here-in-before but 25 Sq mm 4 core .
600
-
-
... More
All as per Ser item No 36 here-in-before but 16 Sq mm 4.0 core .
200
-
-
... More
All as per Ser item No 36 here-in-before but 10 Sq mm 4 core .
300
-
-
... More
All as per Ser item No 36 here-in-before but 10 Sq mm 2 core .
200
-
-
... More
Relaying only serviceable LT UG Cable obtained from Srl item No 35 of any size and discription including necessary cable lugs. Note :- All relevent items like excavation, earth work tc shall be paid and measured seperately.
400
-
-
... More
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
262.44
-
-
... More
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
19.3
-
-
... More
Relaying of Old brick recovered from item No 48 or during excavation for protection of cable all as specified & directed.
9.67
-
-
... More
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
40
-
-
... More
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 100/80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed. Note :- GI pipe shall be measure and paid separately under respective item.
40
-
-
... More
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
3
-
-
... More
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
30
-
-
... More
All as Per Srl Item No 53 above but of size 80 mm dia
10
-
-
... More
All as Per Srl Item No 53 above but of size 100 mm dia
20
-
-
... More
M&L for earthing complete with galvanised iron steel earth plate of size 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthing by means of nuts bolts check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 5 of SSR Part-I including testing on completion all as specified and directed.
7
-
-
... More
Dismantling and taking down of LED/Street light/ Bollard Light of any cap any size any make complete all as specified and as dierected.
7
-
-
... More
S&F in replacement light fitting Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 (surface mounting lense type SMD LED) flood light luminaire with high power LED 180 W. complete all as specified and as dierected.
4
-
-
... More
All as per Item Ser No 58 but rectangular flood light LED 120W ( with surface mounting lense type SMD LED) complete all as specified and as dierected.
3
-
-
... More
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring 12KW, 3P, three phase, max load 12KW complete all as specified and directed.
1
-
-
... More
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT/HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note:- (a) Tools & plants including safety measures equipments like belt, ladder & ropes etc shall be arranged by the contractor at own cost.(b) Contractor supervisor will take proper shut down before starting the work and clear it before resuming power supply, however full assistance will be provided by MES Staff.
80
-
-
... More
M&L for spraying chemical (Roundup) on area to remove unwanted vegitation / grass at E/M installations / 2 pole/ 4 pole structures complete all as specified and directed. Note : Labour and equipments to spray chemical on required area are inclusive in quoted rate.
20
-
-
... More
S&F electric shock treatment chart of size approx 3ft x 2ft & 6 mm thick plywood with teak wood frame and covered with glass complete all as specified and directed.
2
-
-
... More
S&F of notice board of size approx 4 ft x 3 ft duly fixed with 6 Nos clips for display of instructions with aluminum frame including covered with plastic laminated sheet complete all as specified and directed.
2
-
-
... More
S&F fire retardant/ extinguishing Electric Insulated Synthetic mat" INSULATICA 2000" of size 2 mtr x 1 mtr x 2 mm thick ± 10% conforming to BIS : DOC.NO ETD-02(5229) P DT D30/06/03, meeting requirements of IS:3043,IS:5216 (Part-1,2&3), IS-8437 and IEC 479 Pub-1, 61111 & 61112, Tested for break down strength,Tensile/ Elongation, Ageing properties, Insulations Resistance, effects of Acid-Alkaline, Diesel and Transformer oil, Leakage Current Test, FireTest etc having Min, width of 1000mm ± 20mm.All alllied material such as Pu-Resin, Chemi Bound (Hardner), Spl PVC Adhesive, Liquid Primer etc as per site requirement, suitable for 11000 Volts complete all as specified and directed .
4
-
-
... More
S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed.
600
-
-
... More
All as per Ser item No 66 here-in-before but 06 sqmm complete all as specified and directed
200
-
-
... More
S&F in repair off load change over switch three phase, Four pole with enclosure capacity 400 Amps with side handle operated complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
All as per Ser item No 68 here-in-before but capacity 200 Amps complete all as specified and directed
1
-
-
... More
All as per Ser item No 68 here-in-before but capacity 100 Amps complete all as specified and directed
1
-
-
... More
S&F in repair ON load change over switch three phase, Four pole with enclosure capacity 400 Amps with Front handle operated complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
S & F ACB 4 pole as per exsting make and specification installed at MH sub station of cap 2000 Amp.complete all as specified and directed.
2
-
-
... More
S & F ACB 4 pole/ ACB (bus coupler) as per exsting make and specification installed at MH sub station of cap 1000 Amp. 50 KA complete all as specified and directed.
1
-
-
... More
S & F ACB 4 pole as per exsting make and specification installed at various substation of cap 800 Amp.50 KA complete all as specified and directed.
2
-
-
... More
Supply, fixing, testing and commissioning of Heat shrinkable type end termination jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed.
4
-
-
... More
All as per Srl Item No 75 above here-in-before but 95 to 120 Sqmm.end termination jointing kit complete all as specified and directed.
3
-
-
... More
All as per Srl Item No 75 above here-in-before but 150 to 185 Sqmm.end termination jointing kit complete all as specified and directed.
3
-
-
... More
Supply, fixing, testing and commissioning of heat shrinkable type straight through jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade.
4
-
-
... More
All as per item No 78 above here-in-before but 95 to 120 Sqmm.
5
-
-
... More
All as per item No 78 above here-in-before but 150 to 185 Sqmm.
3
-
-
... More
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed.
1
-
-
... More
Dismantling insulators any type any size from LT poles complete all as specified and directed by Engineer -in-Charge.
20
-
-
... More
M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia complete all as specified and directed by Engineer -in-Charge.
20
-
-
... More
Dismantling of ACSR from the poles complete all as specified and directed by Engineer -in-Charge.
0.5
-
-
... More
M&L Aluminium conductor, steel reinforced incl stringing in position all as specified and directed by Engineer -in-Charge.
0.5
-
-
... More
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground complete all as directed.
100
-
-
... More
Material and labour for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises complete all as specified and as directed.
1500
-
-
... More
S&F of PVC LT OH line spacer for 5 wires complete all as specified and directed.
5
-
-
... More
S&F of PVC LT OH line spacer for 4 wires complete all as specified and directed.
5
-
-
... More
S&F of PVC LT OH line spacer for 3 wires complete all as specified and directed.
5
-
-
... More
M&L for Straight through joints heat shrinkble type 1.1 KV for PVC insulated and sheathed aluminium conductor under ground cable of size 16 to 70 sqmm 3.5 / 4 core including testing of joints after completion complete all as specified and as directed.
5
-
-
... More
All as per Ser item No 91 here-in-before but 95 to 185 sqmm 3.5 core complete all as specified and as directed.
5
-
-
... More
All as per Ser item No 91 here-in-before but 240 sqmm 3.5 core complete all as specified and as directed.
3
-
-
... More
Supply and fixing LED street light fitting 70 Watt with powder coated pressure die cast aluminium compact heat resistance toughened glass with lens and surface mounting diode (SMD) LED as light source and electronic driver of following capacity complete with IP 65/66 protection and including necessary connections with 2.5 sqmm aluminum wire including taking down of old unserviceable lights from pole complete all as specified and as directed
4
-
-
... More
M&L for stay assembly complete with accessories and fittings of diameter of stay rod in 20 mm including earth work complete all as specified and directed by Engineer -in-Charge.
1
-
-
... More
Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge.
1
-
-
... More
Dismantling of LT PCC/steel tubular pole incl coping, foundation etc and serviceable insulators from poles for reuse and shifting of poles to E/M yard or any other location complete all as specified and as directed
2
-
-
... More
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP -31 (9 mtrs long ) Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
2
-
-
... More
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.
2
-
-
... More
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
1
-
-
... More
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge.
10
-
-
... More
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: 1. Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. 2. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.
500
-
-
... More
Disconnection of electric connection from LT Panel of any size dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including all inter connection with aluminium strip of size not less than 0.6Mx0.03Mx6MM 1100 volts grade and suitable current rating including painting of Panels complete with inner & outer with two coats of synthetic enamelled paint over a coat of primer including excavation & earth work required for taking out & refixing the incoming and out going cable etc complete all as directed by Engr -in Charge; Note :-Replacement of unserviceable accessories parts shall be measured and paid separately under relevent items.
4
-
-
... More
Note : (i) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor.(ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned.
(iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (iv) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
-
-
-