Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date30 Sep 2023
Closing Date4 Nov 2023
Tender Amount₹ 8,50,000
Costs
EMD
₹ 17,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_621248_1Bid Award Id
ViewTender No
9108/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down old unserviceable Heat detector and Supply, Installation, testing and commissioning addressbale sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programable inteligent type, blue light opticle thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed.
10
-
-
... More
Supply, Installation, testing and commissioning in replacement addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection complete all as specified & directed.
10
-
-
... More
Supply, Installation, testing and commissioning in replacement addressbale intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination confirms EN54-5 & FN 54-7 LPCB approved complete all as specified & directed.
10
-
-
... More
S&F in replacement maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete with one year warranty including taking down old unsv battery complete all as specified & directed.
12
-
-
... More
Taking down old unsv PCB of Control panel and supply and fixing of PCB of existing make complete all as specified & directed.
2
-
-
... More
S&F in replacement ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temprature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable sizecomplete all as specified & directed. Note: Old unserviceable UPS should be deposited to MES Store yard.
4
-
-
... More
M&L in replacement sub main wiring with two run of single core PVC FRLS IS-694 cable with multi stranded copper conductor of size 1.50 Sqmm and drawing through in PVC medium grade heavy duty conduit pipe on surafce of wall with using 1.50 Sqmm PVC insulated unsheathed multi stranded copper conductor cable connected to earth and earth dolly in conduit including conecting to main board including PVC conduit heavy duty minimum 20 mm dia size complete all as specified & directed. NOTE : (i) One run of conduit with three run of copper cable in equal size shall be measured against one unit.
150
-
-
... More
Taking down any type of detector and clean properly with help of air blower and after cleaning fixed in existing position complete all as specified & directed.
Note : T&P (ladder, Air blower, etc) shall be arranged by the Contractor under own cost and arrangement.
600
-
-
... More
Supply, Installation, testing and commissioning in replacement floor/surface mounting addressable microprocessor fire alarm control main control panel single loop with BS EN 54 and indicating panel sounder circuits complete with LCD Display and push button to acknowledge alarm, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger,compatable with detector for communication to detectors and 2 x 16 character LCD, confirming to IS : 2189 and BSEN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4' character 2 sounder circuits PTR requires network card and modules (per each loop) etc including making all connection and fixing accessories complete all as specified & directed.
1
-
-
... More
Supply, install, testing and commissioning in replacement conventional electronic speaker cum hooter with range of 25-30 meter with output not less than 4 watt including necessary connection complete all as specified & directed.
3
-
-
... More
Taking down old unserviceable siren and supply and fixing Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured with sound output variation of +5 DB 500 mtrs range complete all as specified & directed.
3
-
-
... More
S&F in replacement addressable control unit for siren complete all as specified & directed.
3
-
-
... More
Taking down old unserviceable cable and Supply and laying for XLPE insulated PVC innersheathed, armoured, LT control cable FRLS multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 complete all as specified & directed.
700
-
-
... More
S&F in replacement AFO (Auto fire off) plastic fire extinguisher ball (orange colour) it can self active in the presence of fire, active within 3 to 5 seconds upon reaching the appropriate temprature and extenguish the fire, maintenance free for period 5 years, completely harmless to the human body, area cover 360 degree angle, area of about 70 to 80 sqft, it can be extinguish three classes of fire, solid, Liquid and electrical classes of fire, weight 1.50 Kg, 100% eco friendly, 100% bio-degradable along with fixing on wall accessories complete all as specified & directed.
20
-
-
... More
S&F in replacement Fire extinguisher spray 50 ml aluminium body with stand, spray that works immediately on touch to keep small from growing dangerously out of control complete all as specified & directed.
10
-
-
... More
S&F in replacement Eco fire ABC powder type 6 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :-"Eco Fire / AMEREX / Kidde"
15
-
-
... More
S&F in replacement Eco fire ABC powder type 9 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified & directed. Make :- "Eco Fire / AMEREX / Kidde"
15
-
-
... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified & directed.
160
-
-
... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified & directed.
90
-
-
... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
70
-
-
... More
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose.
50
-
-
... More
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified & directed.
3800
-
-
... More
Labour only for reuse of serviceable bricks obtained from item No 21.00 complete all as specified & directed.
2000
-
-
... More
M&L for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed.
(Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site complete all as specified & directed.
40
-
-
... More
S&F in replacement galvainesd water tubing light grade 50 mm dai of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified & directed.
35
-
-
... More
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 35 Sqmm (earthed) complete all as specified & directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
450
-
-
... More
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 3.5 core x 50 Sqmm (earthed) complete all as specified & directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
115
-
-
... More
Taking down old foam of fire extinguisher and refilling of ABC powder type, CO2 fire extinguisher, foam type fire in extinguisher cylinder complete all as specified & directed. (Note : Contractor shall be provide all safety equipment to the person which is refill the Cylinder)
25
-
-
... More
S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 250 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V (kA rms thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing unserviceable / burnt MCCB from site complete all as specified & directed.
2
-
-
... More
S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V (kA rms thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing unserviceable / burnt MCCB from site complete all as specified & directed.
2
-
-
... More
S&F in replacement of on load change over switch open execution type capacity 400 Amps rated, 4 poles, 440 volts 50 to 60 HZs confirm to IEC 60947-3, IS/IEC 60947-3 suitable for horizontal as well as vertical mounting with operating handle, etc with making all connection and fixing accessories complete all as specified & directed. Make :- L&T / Havells/ Siemens / Indoasian
1
-
-
... More
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements