Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Sep 2024
Closing Date5 Dec 2024
Tender Amount₹ 6,72,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.

1

-

230677.8

... More
Sch A Part III (INTERNAL ELECTRIFICATION)

-

-

-

... More
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .

1

-

1720996.17

... More
Sch A Part IV (EXTERNAL WATER SUPPLY)

-

-

-

... More
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV

1

-

150049.08

... More
Sch A Part V (EXTERNAL ELECTRIFICATION)

-

-

-

... More
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.

1

-

423695.01

... More
Sch A Part VI (SEWAGE DISPOSAL)

-

-

-

... More
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.

1

-

324919.83

... More
Sch A Part VII (AREA DRAINAGE)

-

-

-

... More
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII

1

-

349355.48

... More
Sch A Part VIII (ROAD/ PATH & CULVERT)

-

-

-

... More
Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VIII

1

-

2321240.73

... More
Sch A Part IX (SITE CLEARANCE AND EARTHWORK)

-

-

-

... More
Lump sum price worked out by the contractor for Site clearance and Earthwork as listed in Sch ‘A’ Part IX

1

-

814157.12

... More
Sch A Part X (COMPOUND WALL & GATE)

-

-

-

... More
Lump sum price worked out by the contractor for Compound Wall & Gate as listed in Sch ‘A’ Part X

1

-

350491.74

... More
Sch A Part XI (CHAIN LINK FENCING)

-

-

-

... More
Lump sum price worked out by the contractor for Compound Wall & Gate as listed in Sch ‘A’ Part XI

1

-

294271.57

... More
Sch A Part XII (HOT WATER SUPPLY)

-

-

-

... More
Lump sum price worked out by the contractor for Hot Water Supply as listed in Sch ‘A’ Part XII

1

-

102657.12

... More
Sch A Part XIII (DEMOLITION)

-

-

-

... More
Lump sum price worked out by the contractor for Demolition as listed in Sch ‘A’ Part XIII

1

-

429025.62

... More
Sch A Part XIV (Miscellaneous Items of B/R and E/M)

-

-

-

... More
Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,100 mm (4”) dia all as specified and directed.

130

-

-

... More
S&F hot and cold water basin mixer crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed

24

-

-

... More
S&F hot and cold wall mixer crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed

24

-

-

... More
S&F hot and cold water sink wall mixer crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed.

8

-

-

... More
S&F health faucet with tube and hooks crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed

24

-

-

... More
S&F nozzle bib tap crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed

8

-

-

... More
S&Ftwo way angle cock crome finish brass body screwed for iron pipe and fixed with 15mm dia pipe complete all as specified and directed

24

-

-

... More
Supply and fix in medium grade GI pipe bend to shape 1.5 mtr (32 mm dia as required at site) with two Nos clamps made out of 50x6 mm flat and two Nos bolts & washer with nuts duly grounted in wall or fixing on pole all as directed.

5

-

-

... More
S&F Thermo plastic (polystrene) cable junction box, having protection class IP-66 and of over all size 155mmx210mmx92mm (Apprx) having metric nockout cables, the cot on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, washers and two Nos polymide weather proof cable glands of cable sealing range 10 mm to 17 mm ( complete with check nuts) and including 1 Nos 30 amp 4 way cable connector and 1 Nos 6 amps SP MCB. Note :- During connection the incoming and outgoing cables, the continuty of armour to be maintained by shoting them inside the box and earth continuty to be looped for LED fitting for grounding purpose complete all as spcified and directed.

5

-

-

... More
S&F Copper wire PVC insulated 3 Core multistranded of size 1.5 sqmm with FRLS PVC insulated copper conductor, cable in surface/recessed as required from junction box to street light fittings complete all as specified and directed.

50

-

-

... More
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 300 Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for incoming and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, Fixed type, 160 Amps with breaking capacity 16 KA -01 Nos (b) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos Outgoing: - (a) MCCB 4 Pole, 415 V, Fixed type, 63 Amps with breaking capacity 16 KA -03 Nos (2 nos. for bldg & 1 no. spare) (b) MCB 16 Amp 230V with breaking capacity of 10 KA - 01 Nos ( for street light ) (c) Time switches 230 V Single Phase of 20 Amp rating with contactor - 01 No

1

-

-

... More
Supply and fixing LED Light fitting bed side lamp with high out put , 9 watt, 220 v AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and direceted.

24

-

-

... More
Supply , install, testing & commossioning of indoor type, wall mounted ( with anchor bolts & nuts)compartmentalized type Meter Cabinted for provision and fixing arrangements of 4/6 Nos energy meters of overall dimension 1200mm(W)X750mm(H)X200mm(D) made out of 2.0mm thick CRCA sheet with front door having out duly covered with polycorbonate/glass panel for viewing Kwh meter/Timer and other door shall be opaque. All door should have gasket and locking arrangement to meet ingress protection level IP-43, The cabinet shall be painted both internally and externally with powder coated paint ( RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinate shall be fabricated as per drawing and comprising of following accessories:- (a) Four pole MCCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side - 01 No. (b) Copper Bus Bar of size 25mm x 3.15mm duly mounted of FPR insulated and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code- 4 Nos. (c) MCB TPN 40 Amps, 10 KA - 4 Nos (To be connected with Meter) (d) MCB SP 06 Amps, 10 KA -2 No (e) Analog time switch 20 Amp-01 No. (f) LED indicating Lamps, 22mm with 3 Amp SP MCB-03 Nos. (g) 3 Way Bakelite strip type cable connector 30 Amps raitng - 06 Nos. (h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up, 24 Hrs programmable type with 1 NO & 1 NC output contact - 01 No. (for security light). (j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- (i) MCCB to Bus Bar - 10.0 Sqmm copper. (ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 sQMM. (iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm.

2

-

-

... More
Supply and installation and commissioning and testing complete of manucturer OEM manufactured , static silent (sound proof Enclosure) Diesel Engine driven generating set of capacity 63 KVA 415 volts, 3 phase 4 wire, water cooled , system of supply . The DG set shall consist of diesel engine complete to a matching alternator , through flexible coupling and mounted on comman base frame and complete with control panel standardized by manufacturer , fuel tank with mounting arrangement and inlet , outlet return intel oil arrangement , exhaust pipe complete and suitable for conditionss prevalent at Bamrauli (capacity of Enfine , Alternator shall worked out taking alderating factors into consideration) including PCC foundation (of suitable size living a least 0.5 mtr all around for ease of movement and 0.5 mtr height ) , anti vibration pads complete as specified and directed , including all feature to comply with latest CPCB guide line and comprising of following:

1

-

-

... More
DIESEL ENGINE Disel engine 1500 RPM , direct injection, multi cylinders, fourstroke, conforming to IS:100001/ISO3046/BS:469/BS:5514 ammended upto date , for contonous running capable of taking 10 % overload for one hour in 20 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 63 KVA at outdoor atmospheric conditions at Bamrauli (Taking all derating factorinto consideration) fitting with the following accessories subject to the design of manufacturer:- (i) Dynamically balanced fly wheel. (ii) Air cleaner oil fly wheel (iii) Elecronic Governor class 1 A with back up Mechanical governor class 1 A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level. (v) Radiator cooling. (vi) Radiatorfan with gaurd. (vii) Vaccum indicator . (viii) Fuel filter and fuel houses. (ix) FIP. (x) Fan and water pump assembly. (xi) Lube oil filter and pump. (xii) Electric starting system with battery charging alternator and axial type started motor including adequate no of high capacity maint free lead acid batry as per manufacturer recommendation including inter connecting cable/leads with terminals complete with start/stop switch voltmeter, etc 01 set . (xiii)Engine safety shut down syste.

-

-

-

... More
ENGINE INSTRUMENT PANEL: Engine Instrument panel shall comprising of the following: (i) Starting On/Off switch. (ii) Water temp gauge (iii) Hour meter cum RPM meter. (iv) Lube oil pressure gauge. (v) Lube oil temperature gauge. (vi) Batter charging meter. (vii) Safety alarm against high water temp and lube oil pressure . (viii) Any other item not included/specified but is a standard design of the manufacturer. ALTERNATOR shall be self excited, self regulated, brushlees for 63 KVA contineous operation at the speed of1500 RPM with advance electronoc volage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclouser directly coupled with engine through flexible coupling and confirming to IS-4722 complete 01 Nos. Comman fabricated base frame for Engine and alternator made from structural channel, jerk proof PCC :1:2:4 mix type B-1 foundation including adequate no of suitable anti-vibration pads all as per manufactorer recommendations is deemed to be included in the unit rate quoted by the contractor. Bottom mounted (or as per manufaturer design) steel fuel tank fabricated out of 14 SWF MS sheet of capacity not less than 12 Hrs countineous operation inside canopy with fuel level gauge , drain plug locking arrangements etc. with and including GI Pipe connections duly laid as per engineering practise complete all as specified and directed.

-

-

-

... More
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 150 Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for I/C 100 Amps and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 25 KA -01 Nos (b)Change over switch with HRC fuse of cap 100 Amps, 4 pole for incoming S/by supply - 01 No (c) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos Outgoing: - (a) MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 25 KA -02 Nos (one S/by) (b) MCCB 4 Pole, 415 V, fixed type, 32 Amps with breaking capacity 25 KA -01 No (c) MCB 16 Amp 230V with breaking capacity of 10 KA - 01 Nos (Security light )

1

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground lev el with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 40mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.

8

-

-

... More
M&L Earthing complete with Copper earth plate electrode 60 cm x 60cmx 3.15 mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to Copper strip 25 x 3 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 40mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.

4

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground lev el with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron 4.0 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 40mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.

6

-

-

... More
Design supply, install testing & commissioning passengers lift for 13 passenger (884 Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G + 03 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) , complete all as specified and directed by Engineer-in-Charge. Note:- Overall quoted rates incl of all consumables and minor parts Annual maintenance contract (AMC) during the defect liability period of two year. Necessary MoU shall be submitted by rhe contractor duly signed by the OEM of AMC and further maintenance.

1

-

-

... More
Sch A Part XV (MANNING AND OPERATION OF LIFT)

-

-

-

... More
Manning and operation of Lift for two years DLP of semi skilled category industrial personnel wearing unifrom in one shift per day each of 8 hours including Sunday and holiday complete all as specified and directed by GE.

-

-

-

... More
For first year

365

-

-

... More
For second year

365

-

-

... More
Sch A Part XVI (ANNUAL MAINTENANCE OF LIFT)

-

-

-

... More
M&L for annual maintenance of Lift by performing all fortnightly, monthly, bi monthly, half yearly and yearly checks and tests including all repair and replacement of unserviceble spare parts for making serviceable after the completion of defects liability period (DLP) through OEM all as per specified and directed. Note:- (a) The contractor shall enter into MoU with the OEMs for the provn of the lift and further maintenance. The MoU for the post warranty/post defect liability period between the contractor and OEM shall be submitted. (b) The rate quoted is inclusive of all consumable and minor parts but excluding of spare parts. If there is any requirement of major spare parts , same will be measured and paid under PC sum.

-

-

-

... More
For first year

1

-

-

... More
For Second year

1

-

-

... More
For Third year

1

-

-

... More
Sch A Part XVII (PRIME COST SUM)

-

-

-

... More
Lump sum price worked out by the contractor forPrime Cost Sum as listed in as listed in Sch ‘A’ Part XIV. Note :- The amount to be quoted by the Tenderer in BOQ inserted by the department shall be restricted to Maximum 15% over and above the prime cost sum , accordingly the tenderer shall quote the amount.

1

-

50282

... More
Deduct schedule of credit of Rs 173180.00 as brought out from page no. of tender

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.