Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date8 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692370_1Tender No
8758/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking out U/S control wiring complete from servo controlled voltage stabilizer of any capacity and of any make up to 75 KVA 3 phase 415 volts. Providing new control wiring complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including copper cables lugs, connectors, channels and fixing in replacement of any other worn out/unservicable items to make functiononal, complete all as specified and directed.
4
-
-
... More
Taking out U/S control wiring complete from servo controlled voltage stabilizer of any capacity and of any make 100 KVA to 400 KVA 3 phase 415 volts. Providing new control wiring complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including copper cables lugs, connectors, channels and fixing in replacement of any other worn out/unservicable items to make functiononal, complete all as specified and directed.
4
-
-
... More
Taking out U/S control wiring complete from servo controlled voltage stabilizer of any capacity and of any make 500 KVA to 1000 KVA 3 phase 415 volts. Providing new control wiring complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including copper cables lugs, connectors, channels and fixing in replacement of any other worn out/unservicable items to make functiononal, complete all as specified and directed.
4
-
-
... More
S&F in replacement of digital control servo card for voltage stabilizer for input supply output supply with following specification : (a) High voltage cut off protection (b) Voltage reduction (c) Automatic ON after 10 sec time dealy (d) Duel display (e) Cast recin CT for Amper usage all as specified and directed by EIC.
8
-
-
... More
Supply and fixing in repair 1.5 Sqmm three core PVC insulated FRLS flexible copper conductor wire for street/security light terminal box , incl suitable size of bottle lugs etc complete all as specified and directed.
500
-
-
... More
Supply and fixing in replacement of Gear suitable for synchronous motors to operate the shaft for variable dimmer stat all as specified and directed by EIC.
8
-
-
... More
Supply and fixing in replacement of trigger (control) transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer as per sample all as specified and directed by EIC.
4
-
-
... More
Supply and fixing in replacement of dimmer stat 70 amps rating suitable for voltage stabilizer of any cap up to 50 KVA per phase of any make to match with existing system, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of dimmer stat above 70 amps to 280 amps rating suitable for voltage stabilizer of any cap aboe 51 KVA to 200 KVA per phase of any make to match with existing system, complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of dimmer stat above 280 amps to 700 amps rating suitable for voltage stabilizer of any cap aboe 250 KVA to 500 KVA per phase of any make to match with existing system, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of dimmer stat above 700 amps to 1400 amps rating suitable for voltage stabilizer of any cap aboe 500 KVA to 1000 KVA per phase of any make to match with existing system, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of drive assemby complete suitable for voltage stabilizers any make up to 200 KVA per phase all as per sample held in Sub Divn , complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of drive assemby complete suitable for voltage stabilizers any make 250 KVA to 500 KVA per phase all as per sample held in Sub Divn , complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of drive assemby complete suitable for voltage stabilizers any make 500 KVA to 630 KVA per phase all as per sample held in Sub Divn , complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of carbon brush with holder as per sample held in Sub Divn suitable for voltage stabilizer of any make, any capacity upto 200 KVA, complete all as specified and directed.
12
-
-
... More
Supply and fixing in replacement of carbon brush with holder as per sample held in Sub Divn suitable for voltage stabilizer of any make, any capacity 250 KVA to 630 KVA, complete all as specified and directed.
12
-
-
... More
Supply and fixing in replacement brass studs with nuts, washers etc complete including porcelain bushes suitable for voltage stabilizers upto 100 KVA cap any make all as required at site, complete all as specified and directed by EIC.
5
-
-
... More
Supply and fixing in replacement brass studs with nuts, washers etc complete including porcelain bushes suitable for voltage stabilizers 150 KVA to 250 KVA cap any make all as required at site, complete all as specified and directed by EIC.
3
-
-
... More
Supply and fixing in replacement brass studs with nuts, washers etc complete including porcelain bushes suitable for voltage stabilizers 300 KVA to 630 KVA cap any make all as required at site, complete all as specified and directed by EIC.
3
-
-
... More
Supply and fixing in replacement breather assembly plastic body of standard size filled with silica gel etc complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S & F in replacement servo motor for instant start & stop, high torque input voltage 440 V, 3 phase, 50 Hz, 1500 RPM as per existing make and size for stabilizer up to capacity 75 KVA complete all as specified and directed.
1
-
-
... More
All as per Item No 24 above but of capacity 100 KVA
3
-
-
... More
All as per Item No 24 above but of capacity 150 KVA - 180 KVA
4
-
-
... More
All as per Item No 24 above but of capacity 200 KVA - 250 KVA
2
-
-
... More
All as per Item No 24 above but of capacity 300 KVA - 400 KVA
1
-
-
... More
All as per Item No 24 above but of capacity 500 KVA - 1000KVA
2
-
-
... More
S & F in replacement of control relay of existing size and rating for over load / short circuit protection / high low voltage cut off / spike and surge protection / single phase protection for stabilizer of capacity 5 - 20 KVA complete all as specified and directed.
4
-
-
... More
All as per Item No 30 above but of capacity 25 - 75 KVA
4
-
-
... More
All as per Item No 30 above but of capacity 100 - 200 KVA
4
-
-
... More
All as per Item No 30 above but of capacity 300 - 650 KVA
3
-
-
... More
S & F in replacement of variable voltage wound coil for stabilizer of capacity 75 -200 KVA complete all as specified and directed.
3
-
-
... More
All as per Item No 34 above but of capacity 250 - 500 KVA
3
-
-
... More
All as per Item No 34 above but of capacity 600 - 1000 KVA
3
-
-
... More
Rectifying and arresting the oil leakage of stabilizer of any capacity, disconnection, removing of all fitments, replacing the components of the stabilizer such as gasket etc. , rectify the leaks in a variety of areas such as fins, flanges, valves, fastener assemblies, oil leakage through pin hole/ crack joint, drain valve, oil leakages through gasket joint etc complete all as specified and directed .
5
-
-
... More
M & L for dismantling of stabilizers of capacity 25 KVA to 200 KVA indoor/outdoor type complete by opening cover by unscrewing nuts, bolts, gaskets, draining out oil and keeping safely for reuse, cleaning the inner body with caustic soda/detergent and washing to removing sludge etc, spray painting one coat in the inner side tank by Zinc chromate paint and preparing the same for reassembling complete all as specified and directed
4
-
-
... More
All as per Item No 38 above but of capacity 201 - 400 KVA
2
-
-
... More
All as per Item No 38 above but of capacity 500 - 1000 KVA
2
-
-
... More
M & L for topping up of oil in voltage stabilizer upto capacity 1000 KVA at site having dielectric strength 40 - 60 KV during filling after initial filtration conforming to IS-335. Oil shall be supplied in sealed container complete all as specified and directed. (Note:- (i) Before topping up transformer oil sealed container shall be got checked at MES (ii) Breakup details of topping of oil as per capacity of voltage stablizer shall be entered in MB ).
500
-
-
... More
Dehydration/ filtration of transformer oil of existing stabilizer installed at site with portable plant to improve the dielectric strength 50 to 70 KV including top up transformer oil upto the level complete all as specified and directed. Note:- (i) Conducting field testing of di-electric strength and acidity test of Tr. Oil to be carried out with acidity test kit before and after filtration. (ii) Transformer oil required for top up shall be measured and paid separately. (iii) The Contractor shall arrange his own the electric power required for testing/ de-hydration as and when required.
10000
-
-
... More
M & L for spray painting of stabilizer of for any capacity indoor/ outdoor type with one coat of red oxide primer and two coats of synthetic enamel paint with compressor spray Gun after removing all dust, rust etc. and writing description with white paint on location complete all as specified and directed
45
-
-
... More
M & L for shifting of Stabilizer / LT panel etc from one location to another location from existing PCC platform and fixing on platform structure by suitable capacity of crane including necessary disconnection and connection and testing on completion complete all as specified and directed.
5
-
-
... More
Dismantling and segregation of burnt and damaged copper coil from stabilizer any capacity and making new coil with insulated copper wire of required gauge craft paper cotton tape insulation as per specification of old stabilizer including opening & heating before assembling the winding core and necessary testing as required including taking out unserviceable winding complete all as specified and directed.
300
-
-
... More
Maintenance and attending break down of under ground cables upto LT terminals of Voltage stabilizer/ LT panels of sub stations, street lights including attending minor repairs and day to day maintenance of LT panels/voltage stabilizer for smooth and trouble free LT power supply , rectification of minor defects to electrical controls and accessories and attending break down at any time round the clock all as specified and directed. Note :- The rate quoted is inclusive of the following :-(a) Attending minor repairs/breakdown without involving any new materials shall be deemed to be included in the unit rate (b) Major repairs/break down involving supply and fixing of materials such as cables, cable joints MCCBs etc are outside scope of contract
220
-
-
... More
Repair/ maintenance of LT panel board/fedder piler box by taking shut down, cheaking of loose contact & tightning all nut bolts, removing of dust by air blower, removing of carbon particles, rubbing of heated portion of busbar and cleaning complete by means of CRC-226/ petrol tightening of all joints in busbar, cheacking of earth and neutral voltage removal of foreign obects, replacement of corroded glands, lugs, thimbles, hinges, doors lock, door knobs, gaskets, busbar sleevs (red, yellow, blue & black ) sets, nuts, bolt washers etc and tightening them properly including removing old paint from the LT panel/ feeder box by paint removers, cleaning & scrapping internally and externally and preparing the surface and applaying two coats of synthetic enameled paint of existing colour over a coat of red oxide primer, PCC base white wash, and writing any description as required complete complete all as specified and directed by EIC
50
-
-
... More
M&L repairs & overhauling of LT ACBs of any capacity of any make by removing out the breaker form the respective panels after taking proper electric shut down & disconnecting the breaker, checking it throughly for the defects & tripping system of the ACB and rectifing them, lubricantion of moveing contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etc reassembling, reinstallation, testing & comissioning of ACB complete all as directed by EIC. Note: (i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates.
15
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 25 to 50 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
4
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 70 to 150 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
8
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 185 to 240 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
6
-
-
... More
Disconnecting of LT supply from APFC panel any type and size and maintenance & servicing of complete capacitor bank panel of any capacity including cleaning of all contacts, decarbonising of contactor contacts with petrol/CRC, checking & tightening of all cable/ bus bar connection, CT connections & replacement of worn out parts such as capacitors, capacitor lugs, MOC, CT's, indicators, Rotary switches, APFC relays, fuses & measuring meters etc including setting of power factor 0.98 to 0.99 and testing after repair complete all as specified and directed.Note- Spare Parts replaced of APFC panel shall be measured and paid separately.
15
-
-
... More
M & L in replacement of MPP heavy duty capacitor bank cylindrical type, 3 phase 440 volts of capacity 5 KVAR including necessary copper lead copper lugs of suitable size complete all as specified and directed.
3
-
-
... More
All as per Item No 53 above but capacity 7.5 KVAR
3
-
-
... More
All as per Item No 53 above but capacity 10 KVAR
3
-
-
... More
All as per Item No 53 above but capacity 12.5 KVAR
3
-
-
... More
All as per Item No 53 above but capacity 15 KVAR
3
-
-
... More
All as per Item No 53 above but capacity 20 KVAR
4
-
-
... More
All as per Item No 53 above but capacity 25 KVAR
4
-
-
... More
All as per Item No 53 above but capacity 50 KVAR
4
-
-
... More
All as per Item No 53 above but capacity 100 KVAR
2
-
-
... More
All as per Item No 53 above but capacity 200 KVAR
2
-
-
... More
S & F in replacement of power factor controller relay of 7 steps suitable for operation at 415 V power and auxiliary both 5 amp as current measurement. The relay shall improve the PF by at least 0.98. The relay shall be microprocessor based with self diagnostic and setting complete all as specified and directed. Make : L& T / Siemens / Schnieder
2
-
-
... More
All as per Item No 63 above but relay 8 steps
2
-
-
... More
All as per Item No 63 above but relay 12 steps
2
-
-
... More
S & F in replacement digital multifunctional meter flush type 3 Phase, Class I in existing LT panel with suitable fixing and repair to wiring as required at site complete all as specified and directed.Make : L&T / HPL / AE / Conserve
3
-
-
... More
S & F in replacement digital PF meter flush type 96X96 Sqmm, fixed in existing LT panel with suitable wiring and repair as required at site complete all as specified and directed.Make : L&T / HPL / AE / Conserve
3
-
-
... More
M & L for repair & welding of LT feeder pillar box / APFC panel front / rear door and locking arrengement with lock & key including minor parts such as hinges, screw, nuts & bolts, gaskets etc including paint patch work making good as per existing colour and complete all as specified and directed.
3
-
-
... More
M & L for scrapping, cleaning, and preparation of old painted surface of LT feeder pillar box / APFC panel out door / indoor type of surface and spray painting with one coat of red oxide primer and two coats of synthetic enamel paint by spray gun complete all as specified and directed.
40
-
-
... More
S & F in replacement Electronic Thyristor Module of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 05 -10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed.
4
-
-
... More
All as per Item No 70 above but of capacity 12.5 - 20 KVAR
4
-
-
... More
All as per Item No 70 above but of capacity 25 - 50 KVAR
4
-
-
... More
All as per Item No 70 above but of capacity 100 - 200 KVAR
4
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
1080
-
-
... More
Returning, filling in, and including spreading, levelling, watering and well ramming in layers not exceeking 25 cm in hard and dence soil all as directed by Engineer in Charge.
1067.52
-
-
... More
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point all as directed by Engineer in Charge.
12.48
-
-
... More
M&L for double walled corrugated (DWC) HDPE pipe of outer dia 50mm and inner dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50sqmm cable complete all as specified and directed.
3500
-
-
... More
Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 35 sqmm 3.5 core. laid in trench/ duct / along pole/wall etc including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete incl taking out ot old unsericeable/damaged cable complete etc all as specified directed. Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
1000
-
-
... More
All as per item No.78 above but cross sectional area 16 Sqmm 4 core complete all as specified and directed.
1500
-
-
... More
All as per item No.78 above but cross sectional area 25 Sqmm 3.5 core complete all as specified and directed.
1400
-
-
... More
All as per item No.78 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
600
-
-
... More
All as per item No.78 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
500
-
-
... More
M&L for double walled corrugated (DWC) HDPE pipe of outer dia 90mm and inner dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90mm suitable for cable protection of size 70sqmm to 95 cable complete all as specified and directed.
1000
-
-
... More
S&F in repair FRP looping box 350x270x200mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 6 Amp, 04 Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed.Make : National/Sintex/Hensel
207
-
-
... More
S&F in replacement of MCCB, thermal magnetic protection type of 160 Amps 35/36KA, 4 pole, 415 volts fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc testing and commissioning complete all as specifiedand directed.
3
-
-
... More
All as per item No 85 above but MCCB of rating 200 Amps 35/36KA, 4 pole, 415V
3
-
-
... More
All as per item No 85 above but MCCB of rating 250 Amps 35/36KA, 4 pole, 415V
3
-
-
... More
All as per item No 85 above but MCCB of rating 350 Amps 35/36KA, 4 pole, 415V
3
-
-
... More
All as per item No 85 above but MCCB of rating 400 Amps, 35/36KA, 4 pole, 415V
3
-
-
... More
All as per item No 85 above but MCCB of rating 630 Amps 50KA, 4 pole, 415V
3
-
-
... More
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 25×4mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 , 40mm thick precast RCC cover in RCC (1:2:4) type B0, with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 3 of SSR part-I including welding with suitble electrode and testing complete all as directed. NOTE :- (i) Main earthing strip from earth plate electrodeto test point upto length of 7.5 mtrs length shall deem to be included in the unit rate quoted against this item. (ii) M&L Tubing GI med grade 40mm dia up to 7.5 mtr for protection of earthing strip and passing the Road/passes and etc.shall deem to be included in the unit rate quoted against this item.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%