Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Dec 2024
Closing Soon28 Dec 2024
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.

10.58

-

-

... More
Labour only for re-laying of old serviceable bricks retreived from taking out for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.

4.32

-

-

... More
M&L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm thick sand laid before laying the cable 150 mm thick sand after laying the cable complete all as specified and directed. Note : Thickness of sand will be measured after punning for payment purpose.

150.9

-

-

... More
Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 70 sq mm, 2/3.5/4 core from trenches, poles/walls and floor includuing taking out old serviceablee bricks from trenches complete all as specified and directed.

2070

-

-

... More
Laying only serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 sqmm to 95 Sqmm 3.5/4 core sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.

600

-

-

... More
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :-

-

-

-

... More
10 Sq mm 4 core

430

-

-

... More
16 Sq mm 4 core

350

-

-

... More
25 Sq mm 4 core

250

-

-

... More
35 Sq mm 3.5 core

160

-

-

... More
50 Sq mm 3.5 core

150

-

-

... More
70 Sq mm 3.5 core

130

-

-

... More
M&L for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-

-

-

-

... More
25 to 50 Sqmm 3.5/4 core

8

-

-

... More
70 to 120 Sqmm 3.5 core

3

-

-

... More
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out door heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-

-

-

-

... More
10 to 50 Sqmm 3.5 core

15

-

-

... More
70 to 120 Sqmm 3.5 core

8

-

-

... More
S&F in repair Security light bracket made of GI pipe 40 mm dia, light grade for mounting, bracket bent to shape 1.50 RM including suitable clamps made with flat iron 32x6mm -(04 Nos) 02 Sets nut bolt including painted with two coat aluminium paint over a coat of red oxide primer and with and including all fixing arrengment complete all as specified and directed.

65

-

-

... More
Taking down carefully unserviceable LED street light, flood light fitting upto 250 watts of any type from pole/wall/High mast, dismantling and checking out serviceability of parts / circuit such as drivers, MCPCB etc, repalcement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including connecting, testing complete all as specified and directed. Note : New parts will be measured and paid separately under relevant items of BOQ as 'supply only'.

220

-

-

... More
Supply only driver suitable for LED Security light 25/30 Watt complete all as specified and directed.

70

-

-

... More
Supply only driver suitable for LED Security light 45/60/90 Watt complete all as specified and directed.

60

-

-

... More
Supply only driver suitable for LED Flood light 90/120/150 Watt complete all as specified and directed.

60

-

-

... More
Supply only driver suitable for LED Flood light 200/250 Watt complete all as specified and directed.

30

-

-

... More
Supply and fixing in repair LED landscape light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame , IP-65, 25 watt LED for gates with and including all fixing arrangements complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair LED road way light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame IP-66, 30 watt LED complete all as specified and directed.

75

-

-

... More
Supply and fixing in repair of LED road way light fitting luminaires ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-65, 45 watt LED with 110LM/W complete all as specified and directed.

80

-

-

... More
Supply and fixing in repair LED flood light fitting suitable for high mast light with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 150 watt complete all as specified and directed.

28

-

-

... More
Supply and fixing in repair LED flood light fitting suitable for fixing on high mast light including all fixing arrangement high grade aluminium pressure die cast and toughened glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 120 watt complete all as specified and directed.

35

-

-

... More
Supply and fixing in repair LED flood light fitting suitable for high mast light with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 150 watt complete all as specified and directed.

34

-

-

... More
Supply and fixing in repair LED flood light fitting suitable for high mast light with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 250 watt complete all as specified and directed.

20

-

-

... More
Supply and fixing in reapir MCB SP 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.

22

-

-

... More
S&F in reapir Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar(25x3 mm) , having protection class IP-65 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, having three phase cable connecter, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB complete all as specified and directed.

60

-

-

... More
M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.

5

-

-

... More
Preparation of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint from 1.5 mtr above ground level to top of pole and making alternate strips/layers (30 cm wide) with white and blue synthetic enamel paint upto the 1.50 meter height from the ground level including writing the pole number in white letters on black background and cleaning/cutting the grass/bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.

180

-

-

... More
M&L for Copper bus bar chamber fixed on insulator welded with angle iron of size 50x50x6 mm thick grouting in floor, 450 mm depth grouting with PCC (size 450x450x300 mm)1:3:6 type C-2 using 40mm graded stone aggregate upto ground level and 600 mm high above GL complete all as specified and directed of the following sizes :-

-

-

-

... More
200 Amps copper bus bar 04 Nos

2

-

-

... More
100 Amps copper bus bar 04 Nos

3

-

-

... More
S & F in repair cage for protection/housing LED lights made out of 4mm dia GI wire along with suitable size of angle iron frame fixed on foundation with necessary anchor fastner and nut bolts etc complete the size of cage should be 550x450x550 mm including one side with cage opening and locking arrangement and painted with black super enamel paint over a coat of red oxide primer etc complete all as specified and directed.

12

-

-

... More
Supply and fixing in repair on pole/ wall PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor flat/round with including fixing arrangement complete all as specified and directed of the following sizes:-

-

-

-

... More
2 core, 1.5 Sqmm

220

-

-

... More
2 core, 2.5 Sqmm

160

-

-

... More
2 core, 4 Sqmm

200

-

-

... More
2 core, 10 Sqmm

180

-

-

... More
Supply and fixing MCCB of the following sizes on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed -

-

-

-

... More
(a) MCCB 4 pole , 100 amp rating of 16 KA

10

-

-

... More
(b) MCCB 4 pole , 63 amp rating of 16 KA

10

-

-

... More
M&L for repair of Street light panels and timer switch with replacement of unserviceable and burnt parts including all wiring and setting of timer switch with sun set and sunrise including all necessary accesories required for smooth functioning of panel and timer switch

5

-

-

... More
M&L for repair of Swivel/search LED lights including motor repair/winding, circuit repair and repair of all un-serviceable parts of panel board of swivel light including all necessary accesories required for smooth functioning of Swivel/Search lights. Note : (i) The working height of watch tower is min 15 meter (ii) The contractor shall carry his own arrangement for carrying out the repair work (iii). Contractor quoted rate shall be deemed to be included above aspect. No extra charge shall be paid to contractor on this account.

6

-

-

... More
Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed. Note : (a) Replacement of major items shall be measured and paid under relevant items of this schedule. (b) Repairing upto 03 points at different electrical system without any other material will be considered as one job.

105

-

-

... More
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.

15

-

-

... More
Supply, erecting and fixing in repair in true vertical position, steel tubular swaged pole (410 SP-31) double swan neck type, 09 meter long, complete with cast iron base plate, pole cap, mild steel bolts, nuts and screw including one coats of black bituminous paint externally (upto planting depth) and remaining exterior portion of pole shall be painted with two coats of aluminium paint over a coat of red oxide primer including preparetion of surface including painting blue(sky blue) strips of 30 cm width with synthetic enamel paint in alternate layers up to 1.5 mtr above the plinth block, writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, painting of coping with two coat of cement based paint etc complete all as specified and directed. Note : Excavation, Earth work and PCC etc shall be measured and paid separately.

10

-

-

... More
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3.0 m; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan errection of pole and getting out complete all as specified and directed.

1

-

-

... More
M&L for cement concrete (1:3:6) type C2 using 40 mm gradded stone aggregate in foundations , filling and mass concrete etc complete all as specified and directed.

0.5

-

-

... More
Demolition of PCC/Black bituminous road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.

2

-

-

... More
M&L for Cement Concrete (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board and filling of road cutting etc complete all as specified and as directed.

2

-

-

... More
M&L for rendering 15 mm thick 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) all as specified and directed

10

-

-

... More
M & L Painting to existing light pillar with two coats of synthetic enamel paint of superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.

18

-

-

... More
M&L for GI tube light grade galvanised with all fittings for earthing lead protection of under ground /on wall/pole size 20 mm dia complete all as specified and directed.

125

-

-

... More
S & F in replacement of automatic street light switch using infrared sensor based nature switch, 25 KW equally distributed, 63 Amps, 3-Pole, Model- Swadeep-02 EC 25 Kw 3P for automatic switching of street lights based on LUX level of natural light. The sensor (Nature switch) along with suitable power contactor rating 63 Amps 3-Pole & 40 Amps 2-Pole, MCB SP 63 Amps-03 Nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Sintex make) confirming to IP-54. The contractor suitable to 3-Phase load of 25 kw, rating 63 Amps 3 Pole, MCB rating 63 Amps SP 03 Nos complete all as specified and directed. Make of nature switch- Kakatiya Energy systems Pvt Ltd. Hyderbad / Bjaj /Healer. Contactor: BCH/Lamp;T/Schneider (as per IEC-60947-4-1/IS-13947-4-1), MCB : Hager/Schneider/Legrand/Lamp;T, Circuit wiring: polycab/RR Cable/Finolex/Havells.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.