Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Nov 2024
Closing Date27 Nov 2024
Tender Amount₹ 36,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.

5

-

-

... More
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units,Model No. DPUASC 550, having compressor's capacity 1x5.50 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note for item Nos. 3, 4 & 5 :- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item here-in-after.

4

-

-

... More
supply & fix in repair the new sealed compressor of package type ACs of capacity 11.0 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.

11

-

-

... More
supply & fix in repair the new sealed compressor of package type ACs of capacity 8.75 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed.

3

-

-

... More
supply & fix in repair the new sealed compressor of package type ACs of capacity 5.50 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Notes for item Nos. 6, 7 & 8 :- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only (ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record.

4

-

-

... More
supply & fix in repair , thermostatic expansion valves suitable for 1x11 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.

8

-

-

... More
supply & fix in repair thermostatic expansion valves suitable for 1x8.75 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.

4

-

-

... More
supply & fix in repair , thermostatic expansion valves suitable for 1x5.50 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.

5

-

-

... More
supply & fix in repair , moisture and liquid indicator suitable for 2x11 TR package type AC plants complete all as specified and directed.

4

-

-

... More
supply & fix in repair eliminator filter drier complete all as specified and directed.

20

-

-

... More
Dismenteling & taking out existing defective/ burnt parts of AC electric blower motor of any description & in any position of capacity 5.0 HP for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed.

5

-

-

... More
Dismenteling & taking out existing defective/ burnt parts of AC electric condensor (Outdoor unit) fan motor of any description & in any position of capacity 375W for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed.

20

-

-

... More
Supply & charging non freezing compressor oil of existing make in sealed containers of standard size complete all as specified and directed.

160

-

-

... More
supply & fix in repair , fan belt of blower units of existing size complete all as specified and directed.

40

-

-

... More
supply & fix in repair fan blade (three blade) of existing size & model of condensor units of capacity 11.0 TR complete all as specified and directed.

10

-

-

... More
supply & fix in repair fan blade (four blade) of existing size & model of condensor units of capacity 8.75 TR complete all as specified and directed.

4

-

-

... More
supply & fix in repair fan blade (four blade) of existing size & model of condensor units of capacity 5.50 TR complete all as specified and directed.

3

-

-

... More
supply & fix in repair contactor suitable for blower motor of capacity 7.5HP complete all as specified and directed.

8

-

-

... More
supply & fix in repair power contactor suitable for compressor motor of capacity 15.0HP complete all as specified and directed.

15

-

-

... More
supply & fix in repair auxiliary contact suitable for mounting on contactor complete all as specified and directed.

15

-

-

... More
supply & fix in repair HRC catridge fuse 20A, (IS9224) complete all as specified and directed.

30

-

-

... More
supply & fix in repair glass fuses of rated 6 Amps complete all as specified and directed.

20

-

-

... More
supply & fix in repair PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 11 to 35 Amps suitable for 2X11 TR package type AC units complete all as specified and directed.

5

-

-

... More
supply & fix in repair PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 1X8.75 TR package type AC units complete all as specified and directed.

3

-

-

... More
supply & fix in repair PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 2X5.50 TR package type AC units complete all as specified and directed.

2

-

-

... More
supply & fix in replacement, timer having range 1-10 Amps, 230 volts complete all as specified and directed.

8

-

-

... More
Supply only,supply & fix in repair connector three phase, 4-pole, 100 Amps rated complete all as specified and directed.

18

-

-

... More
supply & fix in repair connector single phase, 10 Amps rated complete all as specified and directed.

18

-

-

... More
supply & fix in repair heating element, 3KW, 240 volts, ISI marked suitable AHU chamber complete all as specified and directed.

50

-

-

... More
supply & fix in repair aucostic jali of existing/ approved pattern as in patchwork in AHU room of AC plants complete all as specified and directed.

9

-

-

... More
supply & fix in repair control fuse with base of capacity 2 to 20 Amps complete all as specified and directed.

20

-

-

... More
supply & fix in repair earth fault relay with CBCT, 230 volts AC, coil of capacity 0-100 Amps complete all as specified and directed.

2

-

-

... More
supply & fix in repair earth fault relay with CBCT, 230 volts AC, coil of capacity 0-40 Amps complete all as specified and directed.

2

-

-

... More
supply & fix in replacement, contactor 3 pole with AC coil of capacity 25 Amps complete all as specified and directed.

6

-

-

... More
supply & fix in repair indication lamp LED type, 22.5mm dia, 230 volts complete all as specified and directed.

14

-

-

... More
Supply & Charging refrigrant gas M-22 in cylinders of required capacity including transportation, loading/ unloading and collection of empty cylinders from MES store yard of AGE E/M and returned the same cylinder or other cylinder duly filled and testing of cylindeers including test certificate by authorised agencies complete all as specified and directed.

720

-

-

... More
M&L for fixing new evaporative/cooling coil in replacement of existing in door unit including jointing all liquid and gas lines duly sholdering, breazing ,copper welding all as per manufacturer of capacity 22 TR capacity, model DPUASC22OX of Voltas Make complete all as directed at site.

1

-

-

... More
supply & fix in repair heavy duty copper tubing suitable for package type AC unit gas piping of size 9/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.

18

-

-

... More
supply & fix in repair heavy duty copper tubing suitable for package type AC unit gas piping of size 7/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.

18

-

-

... More
supply & fix in repair pin type HP/LP pin type cut out switch suitable for and including fixing by copper welding on discharge/ suction line of 11 to 5.5 TR capacity package type AC plant unit complete all as specified and directed at site by Engr-in-Charge

9

-

-

... More
supply & fix in repair suction/discharge line control valve of size 9/8" to 7/8" suitable for and including fixing by copper welding on discharge/ suction line of 11 to 5.5 TR capacity package type AC plant unit complete all as specified and directed at site by Engr-in-Charge

5

-

-

... More
Supply and fix in repairs three Phase Auto Sequence Corrector of 200 Amps, 440volt Suitable for correcting the RYB phase sequence, whenever the sequence is changed or reversed all as directed by Engr-in-charge

1

-

-

... More
Technician Charges for Checking of Package type AC for detecting any kind of fault in AC with attending the fault immediately at any time round the clock and Carry out certain repair required as per site requirement. (Note: (a) Parts required shall be measured and paid separately as "supply only" under respective item here-in-before. (b) Rate quoted shall be inclusive of detecting any kind of fault in DG set.

6

-

-

... More
supply & fix in repair MCB TP, 'C' series, 63 Amps, 415 volts, 50Hz, 10kA complete all as specified & directed.

8

-

-

... More
supply & fix in repair MCB TP, 'C' series, 40 Amps, 415 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand/ABB/Schnider

8

-

-

... More
supply & fix in repair adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 200 Amps with breaking capacity 25 kA complete all as specified & directed.

1

-

-

... More
supply & fix inrepair adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 16 kA complete all as specified & directed.

2

-

-

... More
supply & fix in repair adjustable thermal & fixed magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 63 Amps with breaking capacity 16 kA complete all as specified & directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.