Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date12 Dec 2024
Closing Soon10 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i) Air Filter Make and model-as per existing

2

-

-

... More
(ii) Starting relay Make-Totaline/Epcos/CLASSIC/Whirlpool

10

-

-

... More
(iii) Starting capacitor 120-150 mfd Make- Totaline / Epcos / DVM/Whirlpool

10

-

-

... More
(iv) Starting capacitor 100-120 mfd. Make- Totaline / Epcos //DVM/Whirlpool

12

-

-

... More
(v) Running capacitor 40-60 mfd. Make- Totaline/ Epcos/ DVM/Whirlpool

50

-

-

... More
(vi) Running capacitor 30-36 mfd. Make- Totaline / Epcos /DVM/Whirlpool

20

-

-

... More
(vii) Running capacitor 4-6 mfd. Make- Totaline/ Epcos/Whirlpool

20

-

-

... More
(viii) Thermostate switch Make as per existing

2

-

-

... More
(ix) Propeller fan suitable for window/split type AC Make- As per existing

4

-

-

... More
(x) Cooling Coil Make- as per existing

1

-

-

... More
(xi) Condensor coil Make- as per existing

1

-

-

... More
(xiii) Outer cover duly painted for Window/split AC

1

-

-

... More
(xii) MCB SP 20-32 Amps ‘C’ Series ,10KA, 240 volts SP Make : Havells/HPL/Legrand

10

-

-

... More
(xiii) Three pin metalic socket outlet suitable for sheet metal enclosure Make : Havells/HPL/Legrand

20

-

-

... More
(xiv) Three pin metallic plug top suitable for sheet metal enclsoure Make : Havells/HPL/Legrand

20

-

-

... More
(xv) PVC flexible insulated cable multi-strand copper conductor 3/4 core of size 2.5 sq mm Make- Kalinga / Plaza / Gloster/Polycab

100

-

-

... More
(xvi) Front grill for split/window AC Make as per existing

1

-

-

... More
(xix) Wiring kit with thimbles

1

-

-

... More
(xx) Power Contactors 240 volts AC 50HZ 16-25 Amps range.

10

-

-

... More
(xxi) Power contactor 415V AC, 50 Hz 20-32 Amps range

2

-

-

... More
(xxii) Isolator 4 pole 63 Amps 415 Volt

1

-

-

... More
(xxiii) Overload protector suitable for compressor as per existing.

2

-

-

... More
(xxiv) Blower for indoor unit/window AC as per existing.

4

-

-

... More
S & F modular type Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclsoure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of repturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete Make- Legrand / Havells / schnider

4

-

-

... More
Removing the burnt/defective sealed compressor unit any type of any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as directed. Note:- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only.

4

-

-

... More
All as per Sr item No. 4 above but for air conditioner split type 1.5 ton capacity.

3

-

-

... More
All as per Sr item No. 4 above but for air conditioner split type 2.0 ton capacity.

4

-

-

... More
All as per Sr item No. 4 above but for air conditioner split type 3.0 /4.0 ton capacity.

1

-

-

... More
M&L for replacement of damaged copper tubing of dia 5/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.

60

-

-

... More
M&L for replacement of damaged copper tubing of dia 3/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.

60

-

-

... More
M&L for replacement of damaged copper tubing of dia 1/2 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.

60

-

-

... More
M&L for replacement of damaged copper tubing of dia 1/4 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.

60

-

-

... More
M&L for replacement of damaged insulation with heavy duty foam for copper tubing of split air conditioners complete all as directed

90

-

-

... More
S&F in replacement of PVC drain pipes of size 15 mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge.

60

-

-

... More
Supply and fixing of medium class insulated Hard PVC Drain Water pipe of 20 mm dia with all fittings ie elbow,tee,bend etc all as specified and directed.

90

-

-

... More
Repair to Air conditioner Window/Split type upto 2.0 ton to capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R134a/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.(b) Contractor should be responsible if leakage of refrigerent gas after repair on completing job and done same job without extra payment.

90

-

-

... More
Repair to Air conditioner Split type 3.0 ton to 4.0 ton capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R32/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.

6

-

-

... More
Supply and replacement blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.;

2

-

-

... More
Supply and replacement blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton/3.0 ton/4.0 ton as per existing model complete as directed and specified.

3

-

-

... More
Repair and fixing blower Motor of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.

4

-

-

... More
Supply and replacement Condensor Motor (outdoor motor) for split type Air conditioner as per existing model and any capacity complete as directed and specified.

2

-

-

... More
Repair and fixing Condensor Motor (outdoor motor) for split type Air conditioner as per existing model of any make and any capacity for making air conditioner serviciable complete all as directed and specified.

3

-

-

... More
Repair and fixing Printed Circuit Board of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.

5

-

-

... More
Supply and replacement Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed Make- Voltas/Carrier/toshiba.

6

-

-

... More
(a)Supply and replacement Inverter Type Printed Circuit Board(for indoor and outdoor unit complete) of any make and type of air conditioner split inverter type of any make and type (variable speed compressor) as per existing model and capacity up to 2.0 ton complete all as specified and directed. Make:Carrier (X power gold)/Electrolux/LG/HITACHI

4

-

-

... More
(b)Supply and replacement Inverter Type Printed Circuit Board(for indoor and outdoor unit complete) VRF based air conditioner split inverter type as per existing model and capacity 24/28HP/Ton ton complete all as specified and directed. Make:Carrier

1

-

-

... More
Repair and fixing Inverter Type Printed Circuit Board of split type Air Conditioners (with variable speed compressor) of any make and any capacity for making air conditioner serviciable complete all as directed and specified.

10

-

-

... More
Supply and replacement for wireless remote control unit for split/window type airconditioner as per existing model complete all as directed. Make Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS

5

-

-

... More
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.

4

-

-

... More
M&L for Shifting and refixing of window AC of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of window AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas and LDPE pipe are inclusive in quoted rate.(c) Making hole on wall and good the disturbed surface with existing colour matching are inclusive in quoted rate.

2

-

-

... More
M&L for attending day to day complaints and rectifying faults like decarbonizing connections in the AC Box, , any burning due to over loading in AC and restoring connection of AC with wire or thimbles,attending and rectifying faults related to AC like drain water leakage ,filter cleanig,remote setting etc and related to VRF based Air conditioner upto24/28 Ton capacity incl Sunday & Holidays complete all as directed by Engineer-in-Charge. Note : (i) All T&P required shall be provided by contractor including ladders of any size as per requirement at site. (iii) Minor items like machine screw, plastic clamps, insulation tape, nails, flexible pipe, thimbles, lugs for contactor, etc shall deemed to be included in the unit rate. (iv) The major items replaced during repairs shall be measured and paid under respective items of Sch 'A'.

150

-

-

... More
DESERT COOLER

-

-

-

... More
Taking down/out desert cooler of any make and capacity from various locations and M & L for complete cleaning washing and descaling scraping down and removing existing paint, preparation of surface and painting the entire/complete body of desert cooler, inside and outside, by sprayer with two coats of approved synthetic enamel paint and writing SM/ MES no. with black synthetic enamel paint by complete all as specified & directed EIC.

140

-

-

... More
M&L for desert cooler’s cabinet, locally fabricated with three side panels (front, top and tank) and vertical members made out plain galvanised iron sheet with double diversion grills and grill box suitable for 18” sweep fan and making holes for connections with and including fixing arrangements such as 4 way PVC distributor, PVC pipe 3 to 4 Mtrs for spraying water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 Amps piano type switch etc complete all as specified and directed.

30

-

-

... More
S&F water lifting pump submersible type upto 1.5 Meter head,40 Watt Suitable for 220-240V, AC 50 Hz 1 Phase and including taking out existing defective pump from Desert Coolers, complete all as specified & as directed.Make : Khaitan or equivalant

110

-

-

... More
S&F in replacement of ready made wood wool pad with Meshes of size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed.

110

-

-

... More
S&F in replacment of Desert cooler fan motor operating on SP 230 Volts, 50 HZ AC, 150 W,1400 rpm,copper winding with fan blade and mounting Kit complete after and including taking out existing fan motor all as directed. Make : Khaitan or crompton or Equivalent

60

-

-

... More
S&F of PVC sheathed and PVC insulated 3 core cable, 1.5 Sqmm copper conductor of Make: Plaza/ Gloster / Havells / Kalinga complete all as specified and directed.

150

-

-

... More
M&L for replacement of desert cooler fan regulator with selector switch suitable for 3 Speed fan motor SP 230V AC, 400 W complete all as specified and directed.

6

-

-

... More
M&L for replacement of PVC pipe 10 mm bore standard quality of desert cooler complete with fixing arrangement, all as specified and directed.

150

-

-

... More
S&F condenser 4 Mfd for kit/exhaust fan motor of Make: Epcos / Asian / Keltron complete all as specified and directed.

30

-

-

... More
S & F Clamp for kit fan motor as per site requirement with nut, bolt & washers complete.

30

-

-

... More
S & F Piano type switch 5 Amps of Make: Anchor / Cona / Kay.

60

-

-

... More
S & F PVC water distributor, (Set of four way and two way).

60

-

-

... More
S & F plug top 5amp 3 pin type Make:- Anchor/Standerd/Kay

60

-

-

... More
S&F in replacement MS duly spray painted exhaust fan blade 300mm/380mm sweep complete all as directed

10

-

-

... More
S&F Polycarbonate duly spray painted kit fan blade 300mm/380mm sweep complete all as directed

20

-

-

... More
M & L for repair or rewinding with super enameled copper winding wire of exhaust fan motor of desert cooler any type any make including all minor parts like bush,bearing etc all as specified and directed by EIC.

20

-

-

... More
S & F GI Tubing 'Medium grade' of 15 mm size as per existing with screwed socket joints, togather with all tube fitting to connect desert coolar with water pipe line complete all as specified and directed by Eng-in-Charge. NOTE: Cost of bands, Tees, reducing tees ,ends ,elbow, connectors,caps etc and other minor parts not specifically mentioned shall also be replaced where required for proper functioning shall be demanded to be included in the quoted rate. No extra payment shall be made to the contractor on this account.

45

-

-

... More
S & F angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed as specified and directed by EIC.

40

-

-

... More
S & F ball valves (Float Valve) high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe as specified and directed by EIC.

40

-

-

... More
S & F PVC connections 15mm size with PTMT nuts of length 300 mm ( PTMT fitting shall be of approved makes)

30

-

-

... More
Supply and fixing in repair plywood grade BWR type BB of thickness 4.0 mm fixed with screws to timber frame workall as specified and directed.

10

-

-

... More
WATER COOLER

-

-

-

... More
Dismantling of electric connection and water connection of water cooler opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of U/S parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. Note : New spares replaced against Worn out or unserviceable spare parts shall be measured and paid separately as supply only under respective item of this sch.

15

-

-

... More
Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and dischrage line with gas welding work including supply and filling of refrigerent gas R-22 or as per existing at site in suitable quantity as per manufacturers instruction complete all as specified and directed.

4

-

-

... More
All as per item No 55 above but water cooler of capacity 60 Ltrs/hr

1

-

-

... More
All as per item No 55 above but water cooler of capacity 150 Ltrs/hr

1

-

-

... More
Note (For item No 55 to 57) :- (i) Cost of transportation from store to factory and back shall be deemed to be included in the quoted rates. (ii) GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (iii) All new compressor shall be purchased from authorised dealer only. (iv) Capillary, drier, filter strainer are inclusive in unit rate.

-

-

-

... More
M&L for replacement of Rubber hose pipe of 20 mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long complete

1

-

-

... More
M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as directed

1

-

-

... More
M&L for making the system leak proof and charging of gas R-22 / R-134a or existing at site as required in water cooler of any capacity including replacement of drier and capillary tube and testing on load complete all as directed

5

-

-

... More
M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed.

1

-

-

... More
M&L for replacement of condenser fan motor of SP, 230V, cap 1/35 HP with fan blade all as directed

2

-

-

... More
M&L for replacement of condenser fan motor of SP, 230V, cap 1/8 HP with fan blade all as directed

2

-

-

... More
Supply and replacement of 15mm bore Push cock/lift cock brass chromium plated.

4

-

-

... More
Supply and replacement of flexible PVC pipe 40mm/50mm/60mm as per requirement for the drainage of waste water of water coolers all as directed by Engnr-in charge.

10

-

-

... More
Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or at work shop testing for leak proof complete all as directed. Note : (a) Nipple adaptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate.

1

-

-

... More
Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.

1

-

-

... More
Dismantling of electric connection and water connection of water purifier (RO) , electrical accessories and spare parts of system carefully servicing of serviceable parts and replacement of U/S parts reassembling all spare parts incl rewiring of internal connection, testing and commissioning complete all as specified. Note :Minor parts like conection pvc pipe,overflow ,waterflow switch etc are included in quoted rate

2

-

-

... More
Supply only the following items for water cooler :-

-

-

-

... More
(a) Starting capacitor 60/80 mfd

1

-

-

... More
(b) Running capacitor 10 mfd

2

-

-

... More
(c) Thermostat

2

-

-

... More
(d) Relay

2

-

-

... More
(e) Over load protector

1

-

-

... More
(f) Wiring kit

3

-

-

... More
(g) Strainer/filter drum type/pen type

1

-

-

... More
(h) Door gasket

1

-

-

... More
REFRIGERATORS

-

-

-

... More
Repair maint of refrigerator of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator all as directed. Note : Replaced worn out part shall be measured and paid separately as supply only.

10

-

-

... More
M&L for detection of leakage in refregeration of capacity 260L/310L and repairing thoroughly to ensure the complete system leak proof and charging of refrigerant gas as per existing on site with appropriate quality incl necessary brazing, welding, testing and commissioning complete all as directed by Engr-in-Charge. Note : Replacement of Capillary, drier and copper tubing/filter strainer are inclusive in unit rate.

4

-

-

... More
Dismantling of unserviceable sealed compressor unit from refrigerator and replacing with new compressor as existing capacity and charging of refrigerant gas of appropriate qty and testing for smooth functioning complete all as specified. Note : (a) New compressor will be purchased from authorised dealer only. (b) Capillary, drier and additional copper tubing are included in unit rate. (c) Old compressor either cut open or sealed to be replaced with new one.

3

-

-

... More
Supply only the following item for refrigerators as per sample :-

-

-

-

... More
(a) Thermostat switch as per sample

2

-

-

... More
(b) Relay box type as per sample

2

-

-

... More
(c) Door gasket as per sample

1

-

-

... More
(d) Cooling coil as per sample

1

-

-

... More
(e) Condensing coil as per sample

1

-

-

... More
(f) Freezer door any make

1

-

-

... More
(g) door switch

2

-

-

... More
(h) Bulb Holder

1

-

-

... More
(j) Door Handle

3

-

-

... More
(k) Lamp

2

-

-

... More
(l) Door Lock

3

-

-

... More
(n) bottle holder shelves any size

3

-

-

... More
(o) Vegetable tray with cover

2

-

-

... More
(p) Main shelves

2

-

-

... More
(q) water filter for samsung Refrigertor

1

-

-

... More
(h) Printed circuit board for invertor type Refrigertor of capacity upto 320 Ltrs for existing model

1

-

-

... More
DEEP FREEZER

-

-

-

... More
M&L for Repair maint of deep freezer of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of deep freezer all as directed. Note : Replaced worn out part shall be measured and paid separately as supply only.

6

-

-

... More
M&L for making the system leak proof and charging of gas as required in Deep Freezer of any make of capacity up to 400Ltr including replacement of drier and capillary tubing and testing on load complete all as directed.

3

-

-

... More
Supply and replacing Cable 3 core flexible heavy duty copper cable of size 2.5 sqmm for AC , Water Cooler ,Stabilizer etc. complete all as specified and directed.

15

-

-

... More
Removing burnt/defective sealed compressor unit of any make from DEEP FREEZER of any capacity by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and dischrage line with gas welding work including supply and filling of refrigerent gas R-22 in suitable quantity as per manufacturers instruction complete all as specified and directed.

2

-

-

... More
M&L for replacement of PVC sheet rubber bedding and lock of top cover of deep freezer of any type and by screwing/welding MS sheet of top cover complete all as directed

1

-

-

... More
M&L for replacement of condenser fan motor of SP, 230V, cap 1/50 HP with fan blade for refrigerator or deep freezer all asspecified and directed

2

-

-

... More
Supply only the following item for Deep Freezer as per sample :-

-

-

-

... More
(a) Thermostatic switch for any capacity

2

-

-

... More
(b) Relay /capictor any type for any capacity as per sample

3

-

-

... More
(c) Door gasket as per sample

2

-

-

... More
(d) Cooling coil as per sample

1

-

-

... More
(e) Condensing coil as per sample

1

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.

366

-

-

... More
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-

-

-

-

... More
(a) One light, fan, bell point controlled by one switch.

141

-

-

... More
(b) One 3 pin switch socket outlet point 5 Amps on independent board.

60

-

-

... More
(c) One 3 pin switch socket outlet point 5 Amps on same board with other switch.

12

-

-

... More
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 Sqmm size.

28

-

-

... More
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC casing caping mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-

-

-

-

... More
(a) One light, fan, bell point controlled by one switch.

60

-

-

... More
(b) One 3 pin switch socket outlet point 5 Amps on independent board.

25

-

-

... More
(c) One 3 pin switch socket outlet point 5 Amps on same board with other switch.

10

-

-

... More
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 Sqmm size.

30

-

-

... More
Supply and fix in repair Switch piano 6 amps, single pole, one way, 230 volts

320

-

-

... More
Supply and fix in repair Switch piano 16 amps, single pole, one way 230 volts

260

-

-

... More
Supply and fix in repair Socket outlet 6 Amp 2pin & 3 pin, flush type

210

-

-

... More
Supply and fix in repair Socket out let, 16 amp and 6 amp, flush type

180

-

-

... More
Supply and fix in repair Electronic fan regulator 5 step 230 volts,switch type

50

-

-

... More
Supply and fix in repair Electronic fan regulator 5 step 230 volts, socket size

60

-

-

... More
Supply and fix in replacement Switch socket combination 2 IN 1 3 PIN 6/16 Amp 220 Volt flush type.

60

-

-

... More
Supply and fix in repair Lamp holder, insulated body, with back plate 230 Volt suitable for batten fittings.

105

-

-

... More
Supply and fix in repair Capacitor 230 volt, 1 Mfd all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply and fix in repair Capacitor 230 volt, 2.5 Mfd for ceiling fans

250

-

-

... More
Supply and fix in repair Capacitor 230 volt, 3.15 Mfd for ceiling fans

210

-

-

... More
Supply and fix in repair Switch modular type, 230 volts, single pole, one way, 10 Amp, one module.

140

-

-

... More
Supply and fix in repair Switch modular type, 230 volts, single pole, one way, 16 Amp one module.

120

-

-

... More
Supply and fix in repair Socket out let 5 pin, 10 Amp, 230 volts modular type.

130

-

-

... More
Supply and fix in repair Socket out let 5 pin, 10 amp & 20 amp, 230 volts modular type.

150

-

-

... More
S&F in repair Modular Fan step regulator, 120W - 2 module complete all as specified and directed.

150

-

-

... More
S & F ceiling rose surface backlite 65x50mm 3 terminals complete.

120

-

-

... More
Supply & fix in replacement PVC box comprising of switch socket combination multi - purpose 5 pin, 6/16 Amp box type complete all as specified and as directed.

110

-

-

... More
Supply & fix in replacement PVC box comprising of switch socket combination multi - purpose 3 pin, 6 Amp box type complete all as specified and as directed.

110

-

-

... More
Supply and fix in replacement calling bell ding dong type 220 volt 50 Htz

10

-

-

... More
Supply and fix in repair LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, 2200 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.

380

-

-

... More
Supply and fix in repair LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, 1000 systems lumen outputwith lifetime of 50000 burning including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.

220

-

-

... More
Supply and fix in repair 2x2 LED fitting recess mounting flate panel 36 watt, down light 240 volt 50 Htz 150 luumen/watt comprising driver locking arrangement prewired completely.

8

-

-

... More
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/76 twin core and making connections from ceiling rose to fan complete all as directed.

270

-

-

... More
Supply and fix in replacement 1.5 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.

270

-

-

... More
Supply and fix in replacement 2.5 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.

270

-

-

... More
Supply and fix in replacement 4.0 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.

160

-

-

... More
Supply and fix in replacement 6.0 Sqmm FR PVC insulated stranded copper conductor cable 1100 volts grade all as specified and directed.

160

-

-

... More
Supply and fix in repair PVC gang box ISI marked three module for mounting one 5 amp socket & switch

60

-

-

... More
Supply and fix in repair PVC gang box ISI marked fourmodule for mounting one 15 amp socket & switch Make plaza/Anchor

40

-

-

... More
Supply and fix in repair PVC gang box ISI marked six module for mounting two 5 amp socket & two switch

40

-

-

... More
Supply and fix in repair PVC gang box ISI marked 9 module for mounting three 5 amp socket & three switch

35

-

-

... More
Supply and fix in replacement white cover plate with frame three module for modular switches and sockets complete all as specified and directed.

40

-

-

... More
Supply and fix in replacement white cover plate with frame six module for modular switches and sockets complete all as specified and directed.

20

-

-

... More
Supply and fix in replacement white cover plate with frame twelve module for modular switches and sockets complete all as specified and directed.

6

-

-

... More
Supply and fix metal flush box three module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.

20

-

-

... More
Supply and fix metal flush box six module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.

20

-

-

... More
Supply and fix metal flush box twelve module 1.6 mm for mounting modular switches and sockets complete all as specified and directed.

6

-

-

... More
Supply & fixing hylum sheets 3 mm thick (ISI marked) 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.

5

-

-

... More
S & F hylum sheets 3 mm thick (ISI marked) 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.

8

-

-

... More
S & f terminal box of 1.6 mm thick suitble size for fixing 3 mm thick hylam sheet complete all as specified

10

-

-

... More
Supply and fix bulkhead fitting enviornmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulkhead edgelit LED luminaire comprising of highbrightness LEDs of 10 watt

20

-

-

... More
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6.0 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.

104

-

-

... More
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.

110

-

-

... More
Supply and fix MCB, tripple pole and neutral, 415 volts, 32 to 63 Amps rating, 10KA, "C" series fixed in DBs catered herein before.

10

-

-

... More
Supply and fix in replacement MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.

120

-

-

... More
Supply and fix in replacement MCB, SP, 230 volts, 35 to 63 Amp rating, 10 KA, C series fixed in DBs catered herein before.

20

-

-

... More
Supply and fix MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, 'C' series fixed in DBs catered here-in-before.

15

-

-

... More
Supply and fix in replacement heating element modular type of capacity 2 KW, Modular type suitable for star rated modular type geysers of make Bajaj/ Racold/Jaquar with rubber gasket complete all as specified and directed.

95

-

-

... More
S&F in repair plug top 15 Amp 3 pin complete all as specified and directed.

20

-

-

... More
S&F in repair plug top 5 Amp 3 pin complete all as specified and directed.

120

-

-

... More
M&L in replacement plug top, 3 pin, 10/20 amp earth metal clad (ISI marked) complete all as directed.

105

-

-

... More
S&F in replacement socket 3 pin 10/20 amp earth metal clad (ISI marked) as directed.

100

-

-

... More
M & L tape roll big size complete all as specified.

110

-

-

... More
M & L in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser /Exhaust Fan all as directed.

120

-

-

... More
Supply and fix in replacement of inner tank vertical type suitable for 25 Ltr geyser duly enamel coated steel tank of Geyser of gauge 18 SWG of capacity and making welding 4 side of geyser for stop falling of tank complete all as specified and directed.

10

-

-

... More
Supply and fixing in repair ventilating Fan 150 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard

7

-

-

... More
Supply and fixing in repair ventilating Fan 200 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard

8

-

-

... More
Supply and fixing in repair Ventilating Fan 250 mm sweep, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.