Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 May 2025
Closing Soon24 May 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707726_1Tender No
GE (FBD)/AF-25/2025-2026Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable in trenches, complete all as specified and directed.
55
-
-
... More
M&L for sub class `B` bricks for cable protection, complete all as specified and directed.
5.4
-
-
... More
Taking down UNSV LT Under Ground cable of any size, complete all as specified and directed.
950
-
-
... More
Supply and laying, connecting and testing XLPE underground cable, insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc, complete all as specified and directed. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are including in the quoted rates. (ii) All equipments, machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
400
-
-
... More
All as per Item No 07 above but for 4 core 25 Sqmm.
250
-
-
... More
All as per Item No 07 above but for 3.5 core 70 Sqmm.
150
-
-
... More
All as per Item No 07 above but for 3.5 core 95 Sqmm.
150
-
-
... More
Supply & fixing/laying in replacement of HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/cm2, fixing on poles, walls under floors, laying on surface etc, as reqd at site and as per direction of Engr-in-Charge.
Note: All items and accessories, bend, joints, nut bolts, clamps etc are included in quoted rates.
20
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 63 Amps, 415 Volts, 16 kA, complete all as specified and directed.
10
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 100 Amps, 415 Volts, 16 kA, complete all as specified and directed.
5
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 125 Amps, 415 Volts, 16 kA, complete all as specified and directed.
3
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 160 Amps, 415 Volts, 36 kA, complete all as specified and directed.
3
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 200 Amps, 415 Volts, 36 kA, complete all as specified and directed.
2
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 250 Amps, 415 Volts, 36 kA, complete all as specified and directed.
2
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 400 Amps, 415 Volts, 36 kA, complete all as specified and directed.
3
-
-
... More
Supply & fixing in replacement of MCCB, TPN, 630 Amps, 415 Volts, 50 kA, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of 'on load' changeover switches, 4 pole, 400 Amps, 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa, complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of 'on load' changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as per direction of Engr-in-charge.
2
-
-
... More
S&F 'on load' Change Over switch 415V in sheet metal enclosures 4 pole of capacity 320 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required, complete all as specified and directed.
2
-
-
... More
S&F 'on load' Change Over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engr-In-Charge.
2
-
-
... More
S&F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessary nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers including MCB SP 6 amps and making incoming and outgoing connections by taking out loops of cable of any size including necesary excavations and other civil works, complete all as specified and directed.
150
-
-
... More
S&F Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanized iron earth strip 25 x 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified all as specified and directed.
10
-
-
... More
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc, as required 25x4 mm GI strip, complete all as specified and directed.
50
-
-
... More
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2, complete all as specified and directed.
6
-
-
... More
S&F in repair and replacement of synthetic insulating mat of thickness not less than 3.0 mm, size 2.0 mtr X 1.0 mtr, suitable for system voltage 33 kV and break down voltage 45 kV conforming IS 15652 : 2006, complete all as specified and directed.
5
-
-
... More
S&F in repair and replacement of synthetic insulating mat of thickness not less than 2.5 mm, size 2.0 mtr X 1.0 mtr, suitable for system voltage 11 kV and break down voltage 45 kV conforming IS 15652 : 2006, complete all as specified and directed.
5
-
-
... More
S&F in repair and replacement of synthetic insulating mat of thickness not less than 2.0 mm, size 2.0 mtr X 1.0 mtr, suitable for system voltage 3.3 kV and break down voltage 45 kV confirming IS 15652 : 2006, complete all as specified and directed.
5
-
-
... More
S&F in replacement of outdoor type LED flood light 200/210 watt, fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light, Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with separate driver and operating voltage range 120 to 270 V including suitable fixing arrangment, complete all as specified and directed.
5
-
-
... More
S&F in replacement of LED Street Light Luminaries, 60 watt, fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light, pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver, complete all as specified and directed.
10
-
-
... More
Supply and fixing in replacement of LED, Post Top, 20 W, made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, including make proper connection complete including cutting, welding, drilling holes, nut bolts, washer, complete all as specified and directed.
12
-
-
... More
M&L for detecting of fault in HT/LT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no delay on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting, joint making .Joint will be paid under relevant item.
4
-
-
... More
Supply, installation and testing & commissioning of LT Panel of size 1500 x 1200 x 1200 mm in door type made of 2 mm thick CRCA sheet, suitable angle iron frame & PCC, dust & vermin proof, front operated construction, enclosure class - IP 52, CPRI standard including copper Bus Bar of 1000 amps of suitable length, 3 Phase 50 Hz TPN 4 Nos mounted on suitable type of insulators. The metal surface shall be 2.0 mm thickness having powder coating with Seimen's grey colour complete with top /bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors in front & removable plate at the back to achieve dust and vermin proof panel with all inter connection wiring of suitable size of copper wires, circuit labels etc. Panel shall be comprising of separate chambers / modules / compartment to accomodate incomer & outgoing, MCCB and instrument chamber comprise of digital type ammeter & voltmeter flush mounted, selector switches, CT's, etc. The panel board shall be comprising of the following :- Incoming :-
(a) MCCB 800 Amp FP 415 V with rupturing cap 65KA (adjustable type) -01 No
Outgoing :-
(a) MCCB 400 Amp FP 415 V with rupturing cap 36 KA (adjustable type) -02 Nos
(b) MCCB 250 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -02 Nos
(c) MCCB 200 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -02 Nos
(d) Digital Ammeter with LED indication lamp with selector switch -1 No
(e) Digital voltmeter with LED indication lamp with selector switch -1 No
Note : MCCBs shall have adjustable thermal setting
All kA values indicated shall be Ics breaking capacity.
Note : General Arangement drawings shall be got approved by GE before fabrication
1
-
-
... More
Supply, installation, testing and commissioning of LT panel of size 1200 x 1200 x 1000 mm outdoor type made out of 3.15 mm thick CRCA sheet, suitable angle iron frame for structure and base, copper busbar 1000 amps rated with SMC busbar supports - 04 Nos, dust/vermin proof, epoxy powder coated siemens grey painting over a coat of red oxide primer inside/outside of the panel, double shuttered with locking arrangements, cable alley, anodized aluminium with black background with white engraved letter of name plates, schematic diagram for distribution, rubber gaskets, cable glands and internal copper wirings with appropriate lugs complete including necessary civil works and making good disturbed surfaces with following accessories complete all as specified and directed by Engineer-in-Charge. (CPRI Approved) Incoming
(a) MCCB four pole, 50 KA, 400 Amps (adjustable type) - 01 No
(b) Onload change over switch 400 Amps, four pole - 01 No
Outgoing
(a) MCCB four pole, 36 KA, 250 Amps (adjustable type) - 02 No
(b) MCCB four pole, 36 KA, 200 Amps (adjustable type) - 02 No
(c) MCCB four pole, 25 KA, 125 Amps (adjustable type) - 02 No
(d) MCCB four pole, 16 KA, 100 Amps (adjustable type) - 02 No Meter
(a) Digital Ammeter with LED indication lamp with selector switch -1 No (b) Digital voltmeter with LED indication lamp with selector switch -1 No
Note : MCCBs shall have adjustable thermal setting
All kA values indicated shall be Ics breaking capacity.
Note : General Arangement drawings shall be got approved by GE before fabrication
1
-
-
... More
Supply, installation and testing & commissioning of LT Panel of size 1200 x 1000 x 1000 mm out door type made of 3.15 mm thick CRCA sheet, suitable angle iron frame & PCC, dust & vermin proof , front operated construction, enclosure class -IP 52, CPRI standard including copper Bus Bar of 400 amps of suitable length, 3 Phase 50 Hz TPN 4 Nos mounted on suitable type of insulators. The metal surface shall be 3.15 mm thickness having powder coating with Seimen's grey colour complete with top /bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors in front & removable plate at the back to achieve dust and vermin proof panel with all inter connection wiring of suitable size of copper wires, ckt labels etc. Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer & outgoing ,MCCB and instrument chamber comprise of digital type ammeter & voltmeter flush mounted, selector switches, CT's, etc. The panel board shall be comprising of the following :-
Incoming :- (a) MCCB 250 Amp FP 415 V with rupturing cap 35 KA (adjustable type) -01 Nos
Outgoing :-
(a) MCCB 100 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -03 Nos
(b) MCCB 63 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -03 Nos
(c) Digital Ammeter with LED indication lamp with selector switch -1 Nos
(d) Digital voltmeter with LED indication lamp with selector switch -1 Nos
Note : MCCBs shall have adjustable thermal setting
All kA values indicated shall be Ics breaking capacity.
Note : General Arangement drawings shall be got approved by GE before fabrication
1
-
-
... More
Supply, installation and testing & commissioning of LT Panel of size 1200 x 1000 x 1000 mm out door type made of 3.15 mm thick CRCA sheet, suitable angle iron frame & PCC, dust & vermin proof , front operated construction, enclosure class -IP 52, CPRI standard including copper Bus Bar of 600 amps of suitable length, 3 Phase 50 Hz TPN 4 Nos mounted on suitable type of insulators. The metal surface shall be 3.15 mm thickness having powder coating with Seimen's grey colour complete with top /bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors in front & removable plate at the back to achieve dust and vermin proof panel with all inter connection wiring of suitable size of copper wires, ckt labels etc. Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer & outgoing ,MCCB and instrument chamber comprise of digital type ammeter & voltmeter flush mounted, selector switches, CT's, etc. The panel board shall be comprising of the following :-Incoming :-
(a) MCCB 250 Amp FP 415 V with rupturing cap 50 KA (adjustable type) -01 No
Outgoing :-
(a) MCCB 100 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -04 Nos
(b) MCCB 63 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -06 Nos
(c) Digital Ammeter with LED indication lamp with selector switch -1 No
(d) Digital voltmeter with LED indication lamp with selector switch -1 No Note : MCCBs shall have adjustable thermal setting
All kA values indicated shall be Ics breaking capacity.
Note : General Arangement drawings shall be got approved by GE before fabrication
1
-
-
... More
Supply, installation and testing & commissioning of LT Panel of size 1200 x 1200 x 1000 mm in door type made of 2 mm thick CRCA sheet, suitable angle iron frame & PCC, dust & vermin proof , front operated construction, enclosure class -IP 52, CPRI standard including copper Bus Bar of 1000 amps of suitable length, 3 Phase 50 Hz TPN 4 Nos mounted on suitable type of insulators. The metal surface shall be 2.0 mm thickness having powder coating with Seimen's grey colour complete with top /bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors in front & removable plate at the back to achieve dust and vermin proof panel with all inter connection wiring of suitable size of copper wires, ckt labels etc. Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer & outgoing ,MCCB and instrument chamber comprise of digital type ammeter & voltmeter flush mounted, selector switches, CT's, etc. The panel board shall be comprising of the following :- Incoming :-
(a) MCCB 630 Amp FP 415 V with rupturing cap 50KA (adjustable type) -01 No
Outgoing :-
(a) MCCB 400 Amp FP 415 V with rupturing cap 36 KA (adjustable type) -02 Nos
(b) MCCB 160 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -02 Nos
(c) Digital Ammeter with LED indication lamp with selector switch -1 No
(d) Digital voltmeter with LED indication lamp with selector switch -1 No
Note : MCCBs shall have adjustable thermal setting
All kA values indicated shall be Ics breaking capacity.
Note : General Arangement drawings shall be got approved by GE before fabrication
1
-
-
... More
Supply, installation,testing and commissioning in replacement of horizontal single mounted single phase 220V/250V 6000 RPM 50 Hz, AC siren audible range 2 KM 1/4 HP complete including necessary grounting on wall/roof etc including connections, complete all as specified and directed.
3
-
-
... More
S&F in replacement of 50mm dia. GI tubing with screwed socket joints, together with all tube fillings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc. and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required "medium Grade" galvanized laid in trenches or fixed to wall etc, complete all as specified and directed.
250
-
-
... More
All as per item No 41 above but 40 mm dia.
80
-
-
... More
All as per item No 41 above but 25 mm dia.
150
-
-
... More
All as per item No 41 above but 20 mm dia.
150
-
-
... More
All as per item No 41 above but 15 mm dia.
150
-
-
... More
Supply and fix in replacement of 50 mm dia, Gun metal gate valve, ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
All as per item No 46 above but 40 mm dia.
2
-
-
... More
All as per item No 46 above but 25 mm dia.
10
-
-
... More
All as per item No 46 above but 20 mm dia.
10
-
-
... More
All as per item No 46 above but 15 mm dia.
10
-
-
... More
S&F in replacement of fully automatic star delta submersible starter with short circuit protection in sheet metal enclousers, suitable for 50 HP , 415 Volt 50 Hz with over load protector and phase preventer and taking out old U/S starters of any type and any capacity, complete all as specified and directed.
1
-
-
... More
S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 410-0 or Fe 310-0, complete all as specified and directed.
2000
-
-
... More
M & L for preparation of new or previously untreated surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
120
-
-
... More
M&L in replacement of valve chamber of size 1200 x 900 x 900 mm with brick masonary valve chamber, PCC foundation, plastering and necessary excavation and earth work in hard/ dense soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing materials like hinges, nut/bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc all as specified and directed by Engineer-In-Charge.
10
-
-
... More
Supply, assembling and lowering into bore 3" dia MS casing pipe/column pipe with flange type and screwed, socketed and welded, ISI Marked, lengths upto 03 Mtrs long, heavy duty with wall thickness not less than 8 mm including necessary fittings (i.e MS sockets) and jointing from ground level duly painted with two coats of bituminous paint on external surfaces of pipes, complete all as specified and directed.
90
-
-
... More
All as per item No 55 above but 50 mm( 2") bore.
50
-
-
... More
Taking out of bore well submersible pump motor, column pipe with man power/Chain Pulley arrangement and refixing after development and Repair of Submersible pump and motor complete in all respects, complete all as specified and directed.
2
-
-
... More
M&L of flanges rubber gasket, nut and bolts, complete all as specified and directed.
15
-
-
... More
S&F in replacement of HDPE Flexible borewell pipe of 50 mm (2" inch) dia and with 2 male connector nipples, clamp etc, complete all as specified and directed.
100
-
-
... More
Opening the pressure filter 1200mm dia Make-Pentair installed at swimming pool equipment room removing the old filter media, removing all the scaling deposited on the surface area of filter assembly by using wire brush and cleaning the filter with HCL, refilling new filter media ( as per existing type) of various silica grade as required at site, re-assembling the filter assembly and apply one coat of good quality paint on the outer surface area of the filter assembly and testing for leakage for proper functioning and testing with the following specifications is maintained (a) Flow rate 125 m³/ Hr (Each), (b) Vessel dia-2000mm, (c) Filteration velocity 40m³/hr/m², (d) Working pressure 2.5 Kg/Cm² complete all as directed by Engr-in-Charge.
2
-
-
... More
M&L in repair/replacement to existing LT panel board at Pump houses including painting with one coat of synthetic enameled paint to steel surfaces including preparation after scraping, filling, cavities etc, including replacement of damaged bus bar, lugs, copper wire etc, complete all as specified and directed. Note :- U/S items shall be mesaured and paid separately here in after in item No 62 to 66 in 'Supply only'
2
-
-
... More
Supply only MCCBs 415 volts, 4 pole, 25 KA, 100 Amps capacity complete all as specified and directed
2
-
-
... More
Supply only Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed
2
-
-
... More
Supply only Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed
2
-
-
... More
Supply only Selector switch for Volt meter /Ampmeter complete all as specified and directed
2
-
-
... More
Supply only Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed
2
-
-
... More
M&L for repair / replacement of Starter in existing LT panel board at Pump House pertaining to water supply and checking of electrical connection repairing to fault & replacement of U/S items complete including testing Commission complete to be intire satisfaction of Engineer- in-charge all as specified and directed by Engr-in-charge. Note :- U/S items shall be mesaured and paid separately here in after in item No 68 to 73 in 'Supply only'
2
-
-
... More
Supply only Contactor as per suitable in Existing Panel complete all as specified and directed
2
-
-
... More
Supply only Spare kit without coil for contactor type as per suitable in existing Panel complete all as specified and directed
2
-
-
... More
Supply only Electronic timers as per suitable in existing Panel complete all as specified and directed
2
-
-
... More
Supply only over load relay as per suitable in existing Panel complete all as specified and directed
2
-
-
... More
Supply only for Fuse holder & Fuse bases suitable for in existing Panel complete all as specified and directed
2
-
-
... More
M&L for Repair to CI line, any type of lines for stoppes leakages including excavation up to 10 RM (dia. 80 to 200 mm), complete all as specified and directed by Engr - in- Charge. Note :-1.Excavation more than 10RM shall be measured & paid separately
2. Run lead joints shall be measured & paid separately.
30
-
-
... More
Taking out/burning out of leaking and damaged lead joints of the existing CI mains from the position including removing the old lead carefully with out damaging to the pipe complete for the 80mm bore of pipes, complete all as specified and directed.
Note :- Excavation and earth work will be measured and paid separately
5
-
-
... More
All as item No 74 above but 100 mm bore.
10
-
-
... More
All as item No 74 above but 150 mm bore.
10
-
-
... More
Material and labour in replacement of150mm dia of pipe, run lead joints including jointing materials such as spun yarn etc, complete all as specified and directed.
8
-
-
... More
All as per Item No 77 above but 100 mm dia of pipe
8
-
-
... More
All as per Item No 77 above but 80 mm dia of pipe
4
-
-
... More
M&L for Repair to GI line any type lines for stoppes leackages including excavation up to 10 RM.(dia. 15 to 50 mm)
Note :-1.Excavation more than 10RM shall be measured & paid separately .
2.using T&P with GI fittings such as Nipple , socket , union , tee ,Elbow, bend etc complete all as specified and directed. 3.GI fitting ISI shall be measured and paid separately in item No 81 to 110 as supply only
100
-
-
... More
Supply only GI nipple 15 mmx100mm
15
-
-
... More
Supply only GI nipple 20 mmx100mm
15
-
-
... More
Supply only GI nipple 25 mmx100mm
15
-
-
... More
Supply only GI nipple 40 mmx100mm
15
-
-
... More
Supply only GI nipple 50 mmx100mm
15
-
-
... More
Supply only GI Socket 15 mm
15
-
-
... More
Supply only GI Socket 20 mm
15
-
-
... More
Supply only GI Socket 25 mm
15
-
-
... More
Supply only GI Socket 40 mm
15
-
-
... More
Supply only GI Socket 50 mm
15
-
-
... More
Supply only GI Union 15 mm
15
-
-
... More
Supply only GI Union 20 mm
15
-
-
... More
Supply only GI Union 25 mm
15
-
-
... More
Supply only GI Union 40 mm
15
-
-
... More
Supply only GI Union 50 mm
15
-
-
... More
Supply only GI Tee 15 mm
15
-
-
... More
Supply only GI Tee 20 mm
15
-
-
... More
Supply only GI Tee 25 mm
15
-
-
... More
Supply only GI Tee 40 mm
15
-
-
... More
Supply only GI Tee 50 mm
15
-
-
... More
Supply only GI Elbow 15 mm
15
-
-
... More
Supply only GI Elbow 20 mm
15
-
-
... More
Supply only GI Elbow 25 mm
15
-
-
... More
Supply only GI Elbow 40 mm
15
-
-
... More
Supply only GI Elbow 50 mm
15
-
-
... More
Supply only GI Reduce Elbow 15 mm
15
-
-
... More
Supply only GI Reduce Elbow 20 mm
15
-
-
... More
Supply only GI Reduce Elbow 25 mm
15
-
-
... More
Supply only GI Reduce Elbow 40 mm
15
-
-
... More
Supply only GI Reduce Elbow 50 mm
15
-
-
... More
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and Supply & fixing CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes as in item No 112 to 115 complete all as specified and directed:-
-
-
-
... More
All as per item No 111 above but 200 mm dia bore of pipe
1
-
-
... More
All as per item No 111 above but 150 mm dia bore of pipe
3
-
-
... More
All as per item No 111 above but 100 mm dia bore of pipe
3
-
-
... More
All as per item No 111 above but 80 mm dia bore of pipe
2
-
-
... More
M&L in replacement of 100 mm dia, CI Non-return valve as per IS 5312 flanged ends, complete all as specified and directed.
2
-
-
... More
All as per item No 116 above but 150 mm dia.
2
-
-
... More
M&L in replacement of unservicable Butterfly valve type IS 5312 flanged ends 150 mm dia, complete all as specified and directed.
2
-
-
... More
M&L for repairing gland packing of sluice valve including nut, bolts of suitable size 80 mm to 200 mm bore etc, complete all as specified and directed.
2
-
-
... More
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house situated in AF stn chandinagar, complete all as specified and directed.
4
-
-
... More
M&L for chemical and bacteriological analysis of chlorinated water collected from distribution line PH NO 1 situated in AF stn chandinagar, complete all as specified and directed.
4
-
-
... More
Material and labour for "lifting and Lowering of any acpacity" Submersible Pump Set of capacity 30 HP for repair/ Overhauling /rewinding /devolpment incl increasing the length of delivery pipe/or any other requiremwnt at site at tube well installation at AF Station chandinagar with manpower/Chain Pulley arrangement including shifting to local workshop for repair and to bring back after repair at site including testing and commisioning complete all as specified and directed by Engineer-in-Charge.
Note :- Any minor part if required will be provided by contractor without any extra cost.
2
-
-
... More
All as per item No 122 above but Capacity of 10 /15 HP
2
-
-
... More
M&L for Dismantling and strip opening of burnt submersible pump of capacity 30 HP including cuttting removing burnt winding wire from stator assembly and preparing slots, rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnishing etc and re-assembling stator rotor assembly with pump testing, commmisioning such as (i) Impeller GM . (ii) Distance bush SS.(iii) Guide Bush (iv) Neck ring gun metal (v) Impeller key (vi)Guide van (vii) Sand Guard complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
All as per item No 124 above but 10 /15 HP
1
-
-
... More
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 15 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning, complete all as specified and directed.
3
-
-
... More
Material and labour for CI specials such as bends, tees, collars, tail pieces flanges etc complete suitable for CI mains of sizes upto 150mm, complete all as specified and directed.
100
-
-
... More
M&L in replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 10sqmm 3 Core 2run, complete all as specified and directed.
100
-
-
... More
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 16 sqmm 3 Core 2run, complete all as specified and directed.
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%