Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Feb 2025
Closing Soon7 Mar 2025
Tender Amount₹ 46,00,000
Costs
EMD
₹ 92,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697818_1Tender No
8338/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
2
-
-
... More
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
2200
-
-
... More
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
20
-
-
... More
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
4
-
-
... More
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
2
-
-
... More
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 50 mm dia bore complete all as specified and as directed.
30
-
-
... More
M&L for cutting of road up to 0.75 m deep suitable for laying underground cables/MS tubes of any size/dia including GI pipe of 50 mm dia & making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50 mtr complete all as specified and directed.
40
-
-
... More
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with stranded aluminium conductor of size 25 sqmm 4core as per IS 7092 Pt-I complete all as specified and as directed.
430
-
-
... More
All as per item No 12 here in above but of size 16 sqmm 4 core and ditto-
300
-
-
... More
All as per item No 12 here in above but of size 10 sqmm 4 core and ditto-
200
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
120
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 70/72 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
159
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 90 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
105
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 120 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
40
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 100 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
30
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 150 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
24
-
-
... More
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 250 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
Note:-
(i) Warrantty for replacement of each street light fitting shall not be less than 5 years from date of pruchse.
(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.
(iii) CA no. shall also be marked on each fittings with permanent marker.
(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
8
-
-
... More
Supply, erection and connection in replacement of new Pre- streessed concrete poles 102 mm x 172 mm at top and 102 mm x 279 mm at bottom 9.0 mtrs long including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height letters complete all as specified and directed.
4
-
-
... More
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint incl taking down complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
2
-
-
... More
S & F of GI brackets for street light fitting fabricated with GI tubing 32 mm dia for LED Street lights medium grade 1.2 mtr length and bending to angle of 120 degree incl mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5 mm with nut, bolt & washers suitable for fixing of GI bracket complete all as specified and directed.
120
-
-
... More
S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper bus bar 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed
300
-
-
... More
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 3 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead 4.0 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick PCC slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbows etc shall be deemed to included in the quoted rate.
10
-
-
... More
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 3 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised strip 25x4 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick PCC slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbows etc shall be deemed to included in the quoted rate.
4
-
-
... More
Supply & fixing in repair of three phase 415 V automatic street light timer switch of capacity 12 KW using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps - 03 Nos (b).Contactor rating 40 Amps - 03 Nos (c).Out put MCB rating 40 Amps - 03 Nos (d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e) Model No :- SWADEEP -02EC 12 KW 3 P- VMS. Make :- Kakatiya Energy Systems Ltd Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of pruchse.
4
-
-
... More
Supply & fixing in repair of single phase automatic street light timer switch of capacity 8 kw using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, openable doors with lock including taking down of u/s existing feeder pillar box complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 63 Amps - 01 Nos (b).Contactor rating 63 Amps - 01 Nos (c).Out put MCB rating 63 Amps - 01 Nos (d).Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -02EC 8 KW1P- VMS. Make :- Kakatiya Energy Systems Ltd Note:-(i) 01 year Guarantee + 01 year Warranty on sensor & 01 year warranty on remaining other items from date of pruchse.
6
-
-
... More
Taking out under ground, LT cables, different sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches or re-routing after rectification of fault as required complete all as specified and directed
NOTE:- (i) Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separetely.
(ii) Retrieved serviceable bricks or PCC cable cover and sand shall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate.
250
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 40 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed.
5
-
-
... More
Description all as per item No 31 here in above but of capacity 63 Amps with ultimate breaking capacity 16 KA .
6
-
-
... More
Description all as per item No 31 here in above but of capacity 100 Amps with ultimate breaking capacity 25 KA .
3
-
-
... More
Description all as per item No 31 here in above but of capacity 160 Amps with ultimate breaking capacity 25 KA .
3
-
-
... More
S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 30 watts to 60 watts including replacement of burnt drivers carefully and as direcetd
90
-
-
... More
S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 70 watts to 90 watts including replacement of burnt drivers carefully and as direcetd
80
-
-
... More
S&F in replacement of LED drivers of LED streeet light /flood light/Glow sign board as per existing sample of any make , of capacity 100 watts to 150 watts including replacement of burnt drivers carefully and as direcetd
80
-
-
... More
S&F in replacement of heat shrinkable LT straight through joints suitable for 06- 16 Sqmm 4 core cable including jointing with copper lugs and ferrules complete all as specified and directed.
7
-
-
... More
S&F in replacement of heat shrinkable LT straight through joints suitable for 25- 50 Sqmm 3.5/4 core Sqmm cable complete all as specified and directed.
7
-
-
... More
S & F cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint incl taking down existing complete all as specified and directed.
1
-
-
... More
M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint and also including numbering of poles with white paint are located on different locations complete all as specified and directed by Engr-in-Charge.
198
-
-
... More
M & L for painting of steel cross arm, bracing supports of 11/9 mtr PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface and applying cemente based paint over cemented portion of PCC poles, marking with alternator white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint, numbering of poles complete all as specified and directed.
150
-
-
... More
Disconnecting power supply from defective /unserviceable street light/ security light/ high mast light/flood light fitted on 11 mtr/9 mtr/8.5 poles and testing / checking for defects, testing LED drivers, fuse, testing kisok box, over head line connection, tightening of loose nuts bolts of GI brackets on pole, checking connecting wire from pole etc and fixing the repaired / services light fittings on poles and testing & commisining of light.
Note :- (i) All spare like LED drivers, connecting cable, pole box, MCB in pole box etc and refixing in replacement will be measured & paid separately under relevant item. (ii) All necessary T&P (like ladder of suitable height and safety belt) for testing & repair of light fitting will be provided by contractor with out any extra cost.
(iii) Contractor will depute one technician and one helper daily repairs & maintenance of security lights as directed (iv) Contractor will carry out daily repair & maintenance of security light as directed. Contractor has to understand the nature of wks under this item & quote his rate accordingly.
(v) Complaints of unserviceable light fittings will be given by JE E&M to contractor/contractor’s rep to technician on mobile phone followed by writing. Contractor has to arrange required material, T&P & safety equipments to repair the security light within 72 hours from the time of intimation failing which a penality of Rs. 500/- per light per day (beyond 72 Hrs) will be charged and recovered from contractor dues.
270
-
-
... More
M&L for decorative LED post top gate light 40W with IP 65 protection resistant to impact and corrosion,glair free and better uniformity all as specified and directed.
Note:-(i) Warrantty for replacement of each LED post top light fitting shall not be less than 02 years from date of pruchse.(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.(iii) CA no. shall also be marked on each fittings with permanent marker.(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
40
-
-
... More
M&L for decorative LED bollard stailess steel 9 watt weather proof light (warm white)with acrylic diffuser complete with all accessaries all as specified and directed. Note:-(i) Warrantty for replacement of each LED bollard light fitting shall not be less than 02 years from date of pruchse.(ii) Date of purchase shall be marked on each fittings with permanent marker for redeeming warranty benefits.(iii) CA no. shall also be marked on each fittings with permanent marker.(iv) Purchase voucher/ Product to be verified through Auth. Dealer of Company.
40
-
-
... More
Restringing of LT/street light overhead line conductor comprising of any size ACSR conductor after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag including cutting, trimming and vending of branches along HT line and removing of creepers from poles/conductors complete all as directed.
1600
-
-
... More
Cutting and trimming of tree branches of any girth all around the HT/LTover head lines upto two mtr from all around the over head lines complete and removing the cut branches from site to a distance not exc 50 mtr all as directed. Note:- T&P required for cutting/trimming of tree branches shall be provided by contractor without any extra cost.
750
-
-
... More
S&F MCB 63 Amp TPN 'C' series for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand
8
-
-
... More
S&F MCB 6 - 32 Amp SPN for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand
10
-
-
... More
S&F MCB 63 Amp SPN 'C' series for street light complete all as specified and directed. Make:-Havells/L&T/ABB/Legrand
10
-
-
... More
Taking down carefully aluminium/copper point wiring (Building Security light) complete,including fixture and fitting such as switches,ceiling roses,pendents,regulators,sockets,light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of walls, Floors, ceilings etc complete all as specified and as directed.
120
-
-
... More
M & L for concealed point wiring for one light point controlled by one switch with PVC insulated and unsheathed electric cable 1100 volts grade FRLSH conforming to IS 694:2010 having multisranded copper conductor of 1.5Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade (ISI marked with valid CML No ) not less than 20mm dia with all fitting and fixing accessories and 1.5Sqmm FRLSH conforming to IS 14930(Part-I) 2001, PVC insulated unsheathed multistranded copper conductor as continuous earth conductor , concealed to continuous earth dolly by providing suitable lugs with and including pressed steel sunken terminal boxes/modular flux box factory made for mounting switch , regulators etc with and including 2.8mm thick plastic laminated sheet cover(white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminius paint outside and two coats of aluminium paint inside for mounting switches etc complete all as specified and as directed
120
-
-
... More
S&F ceiling rose,surface bakelite 65 x50mm three terminals complete all as specified and as directed.
120
-
-
... More
S&F switch piano type, single pole, one way, 6 amps, 240 volts, ISI marked with valid CML complete all as specified and directed.
120
-
-
... More
S&F in replacement of PVC insulated stranded Copper conductor 1100 Volts grade heavy duty ISI marked three core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
400
-
-
... More
S&F in replacement of PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked three core cable flat or circular of size 6 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
300
-
-
... More
S&F in replacement of PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked three core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
200
-
-
... More
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated copper conductor three core cable flat or circular of size 1.5 sqmm for street light connections etc complete all as specified and direcetd.
500
-
-
... More
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated copper conductor three core cable flat or circular of size 2.5 sqmm for street light connections etc complete all as specified and direcetd.
200
-
-
... More
S&F in replacement aluminium lugs/thimble suitable for LT XLPE cable of size 10 Sqmm to 16 Sqmm complete all as specified and directed
50
-
-
... More
S&F inreplacement aluminium lugs/thimble suitable for LT XLPE cable of size 25 Sqmm to 50 Sqmm complete all as specified and directed
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%