Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Excavation
Eprocure
Opening Date6 Dec 2024
Closing Soon27 Dec 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687445_1Tender No
8300/1277/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L MS work in support over bridge base guarder by fabricated structural steel chequered plate 6mm thick conforming to IS - 3502 and mild steel Fe 410-W(Gde-E- 250) sections & fabrication for support for roller bearing made up of upto 10mm thick MS plate as per site requirement including welding, bending cold or hot drilling holes including nut, bolts any shape and size as directed or indicated including two coats of enameled paint after one coat of zinc chromate primer all as specified and directed.
2000
-
-
... More
Labour and T&P for desilting of Radial well manually and removing silt/sand from not more than 50 mtr depth from the bottom slab and removed/disposed off to a distance of exc 250mtr but n. exc 500mtr , turning ON/OFF water without damage of existing plant and machinery as per time requirement and as directed by Engineer-in-Charge. Note: (i) Contractor will arrange Desilting pump and all T&P as required on site to complete the work. at his own cost.
(i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account.
150
-
-
... More
M&L for cleaning the Radial pipe of 300 mm dia max length upto 50 metre diagonally by Running Diesel Engine driven Air compressor of not less than 20 PSI Pressure Jet for compressed air development and cleaning the existing radial pipe without damaging the same pipe, size of air line should be minimum 65mm complete all as specified and directed. Note: (i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account. .
(ii) Disilting meterial obtain under cleaning of radial pipes will be measured and paid under BOQ item No. 05.00 above. (iii) Proper register/logsheet shall be maintain for running of compresor duly signed by contractor and Eng-in-charge every day.
120
-
-
... More
M&L for bailing out muddy water from radial well by running sludge / disilting pump of 100 HP capacity required during of radial well complete all as specified.
Note : (i) Extra water during cleaning of radial well will be pumped by same disilting / sludge pump. (ii) Contractor will make arrangement to install pump and make connection for pipeline and electric cable for the running of pump electrically will be provided on chageable basis. (iii) Only 04 Hours will be provided to work in a day time.
(iv) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account. (v) Proper register/logsheet shall be maintain for running of sludge /disilting pump duly signed by contractor and Eng-in-charge every day.
30
-
-
... More
M&L for dismantling of MS channel, MS round / square bars, MS framed structure with or without plates completely alongwith nuts and bolts from radial well by cutting with the help of gas cutter without disturbing the pipes and concrete structure complete all as specified.
2200
-
-
... More
M&L framed work MS channels with or without plates, square bars/round bar 10mm, grills, gratings etc with ends of bars shouldered and / or riveted into spikes, framed guard bars, barred iron doors, ladders, framed balusters walk ways railing frame work of ceiling etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
2200
-
-
... More
M&L for MS saddle 40 mm wide and 5 mm thickness bend in suitable shape and size to cover a diameter of 40mm alongwith suitable size carbon steel nut and bolts fixed in bridge to hold LT cable duly painted with two coat rubber paint complete all as specified and directed.
140
-
-
... More
S&F in replacement GI pipe 40 mm dia in heavy class over a sluice valve spindle of size 300 mm to work like a spindle for opening and closing of a sluice valve from top portion of radial well including connecting items required for fixing GI pipe with sluice valve spindle complete all as specified and directed.
Note : (i) Depth of Radial well is approx 50 mtr. Contractor shall take all safety precausion as required during execution of work and cost of same shall be deemed included in his quoted rate. Nothing extra shall be payble on this account.
320
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%