Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date5 Mar 2024
Closing Date4 Apr 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for well burnt brick sub class B old size laying in trenches for cable protection with width equal to length of brick complete all as specified and directed.

18.65

-

-

... More
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

247.95

-

-

... More
M&L for cutting of PCC/Hard standing/WBM road not exceeding 45 cm in width & not exceeding 60 cm in depth for passing of cable and making good of disturbed surface to match with the existing surface complete all as specified and directed .

40

-

-

... More
M&L for making horizontal boring not exe 60 cm deep below road crossing for passing of cable complete all as specified and directed.

20

-

-

... More
Taking out from trenches/duct/floor/wall/roof/under road/drain or hardstanding etc. old existing underground XLPE aluminium conductor LT cable of size 2 to 4 core x 10 sqmm to 16 sqmm for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed by Engineer in Charge.

600

-

-

... More
All as per item no.8 here in before but cable size 3.5/4 core x 25 Sqmm to 50 Sqmm

1100

-

-

... More
All as per item no.8 here in before but cable size 3.5 core x 70 Sqmm to 120 Sqmm

900

-

-

... More
All as per item no.8 here in before but cable size 3.5 core x 150 Sqmm to 240 Sqmm

500

-

-

... More
All as per item no.8 here in before but cable size 3.5 core x 400 Sqmm to 630 Sqmm

200

-

-

... More
Re-laying only or fixing or passing through pipe, in Pole/duct/trench/under road/hardstanding/wall/roof etc. 2 to 4 core x 10 sqmm to 16 sqmm ,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed old serviceable cable after checking of any type of faults (if any) by inspection / using equipment / meggering as required complete all as specified and directed by providing lugs/thimbles/glands by compression arrangement.

200

-

-

... More
All as per item no.13 here in before but cable size 3.5/4 core x 25 to 50 Sqmm

200

-

-

... More
All as per item no.13 here in before but cable size 3.5 core x 70 to 120 Sqmm

400

-

-

... More
All as per item no.13 here in before but cable size 3.5 core x 150 to 240 Sqmm

200

-

-

... More
All as per item no.13 here in before but cable size 3.5 core x 400 to 630 Sqmm

200

-

-

... More
Supply Laying, testing and commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm, 2 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as directed.

200

-

-

... More
All as per item no.18 here in before but cable size 16 Sqmm , 4 core

200

-

-

... More
All as per item no.18 here in before but cable size 25 Sqmm , 3.5 core

500

-

-

... More
All as per item no.18 here in before but cable size 35 Sqmm , 3.5 core

200

-

-

... More
All as per item no.18 here in before but cable size 50 Sqmm , 3.5 core

200

-

-

... More
All as per item no.18 here in before but cable size 70 Sqmm , 3.5 core

150

-

-

... More
All as per item no.18 here in before but cable size 95 Sqmm , 3.5 core

200

-

-

... More
All as per item no.18 here in before but cable size 120 Sqmm , 3.5 core

150

-

-

... More
All as per item no.18 here in before but cable size 150 Sqmm , 3.5 core

100

-

-

... More
All as per item no.18 here in before but cable size 185 Sqmm , 3.5 core

100

-

-

... More
All as per item no.18 here in before but cable size 240 Sqmm , 3.5 core

100

-

-

... More
All as per item no.18 here in before but cable size 400 Sqmm , 3.5 core

50

-

-

... More
All as per item no.18 here in before but cable size 630 Sqmm , 3.5 core

50

-

-

... More
Supply and laying in trenches/Floor or fixed to Pole/Wall in replacement 40 mm bore GI pipe light grade with fitting for protection of cable including taking out old existing pipe complete all as directed.

6

-

-

... More
All as per item No.31 here-in-before but 50mm bore.

6

-

-

... More
All as per item no.31 here in before but pipe of 80mm bore

6

-

-

... More
All as per item no.31 here in before but pipe of 100mm bore

6

-

-

... More
M & L for detection of fault through fault locating high voltage mobile machine to locate the fault in LT / HT cable by giving high voltage surge and to find out exact location of fault all as directed at site. (Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. It is solely bidder's responsibility to arrange fault locating machine & he should'nt expect facilitation from the deptt. for the same.)

20

-

-

... More
M & L for replacement of heat shrinkable type joints suitable for XLPE under ground cable of size 25-50 sqmm 3.5 core all as directed.

6

-

-

... More
All as per item No. 36 above but of size 70-150 sqmm 3.5 core.

10

-

-

... More
All as per item No. 44 above but of size 185-240 sqmm 3.5 core..

6

-

-

... More
All as per item No. 44 above but of size 400-630 sqmm 3.5 core.

4

-

-

... More
Earthing complete with Copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20 x 3 mm size drawn through 40mm GI light grade pipe and including providing 15mm bore GI pipe medium grade as water pipe with suitable size funnel ,as earthing lead filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to copper strip by means of copper nuts, bolts and washers strip connected to earth plate including chamber PCC(1:3:6) type C1 using 20mm graded stone aggregate and PCC cover made with PCC (1:2:4) type B1 using 20mm graed stone aggregate reinforced with 8mm TMT bar @ 100mm c/c alongwith lifting handle of 833 dia steel bar complete all as shown and specified in electrical plate no.3 of SSR Part-I (2009) all as directed. (Note:copper strip upto 7.5 m length in included in unit rate quoted by contractor).

10

-

-

... More
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area as directed.

2200

-

-

... More
Dismantling of Earth wire of any sizes & length and removing the same from the site all as specified and directed.

0.2

-

-

... More
Dismantling of ACSR conductor of any sizes & length and removing the same from the site all as specified and directed.

0.4

-

-

... More
Dismantling of insulators of any type, any sizes and at any location complete and removing the same from the site all as specified and directed.

10

-

-

... More
Restriging of exisiting ACSR conductor / GI wire of any size / any no. conductor including opening of winding wire of ACSR conductor with insulator and winding with new aluminium winding wire and repair of old jumper wires complete all as directed by Engineer in Charge.

30

-

-

... More
M & L for Aluminium conductor, steel rainforced (ACSR) of existing size & length as per site requirement and directed.

0.4

-

-

... More
M & L for Galvanised steel wire 4 mm dia earth wire of existing size & length as per site requirement and directed by Engineer in Charge.

0.2

-

-

... More
M & L for Pin type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel spindle, two galvanazed iron washer and one galvanazed nut, 100mm height, 65mm dia 1100 Volts grade complete all as specified and as directed.

6

-

-

... More
M & L for Shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps 31x3 mm , washers, insulator bolts 12 mm dia, 75 mm height, 90 mm dia & working pressure in 1100 volts all as specified and as directed.

6

-

-

... More
M & L for erection and replacement of stay assembly (wire size 7/4 mm) with stay rod 16 mm dia & insulator loop type with nuts, bolts and washers stay wires size 7/4 mm , Flat iron clamps, Nuts, bolts and washers, MS stay plate 6mm hick of size 230x230mm as shown in electrical plate no.1 of SSR Part-I (2009) including necessary excavation, removal of soil, refilling of soil, PCC 1:3:6 type C2 , plinth protection complete all as directed by Engineer in Charge. (Note:- PCC shall be measured and paid seperetely under respective tems here in after.).

2

-

-

... More
M & L for replacement of PVC Line separator suitable for 02 / 03 nos over conductor with nuts, bolts and washers all as directed.

10

-

-

... More
M & L for replacement of PVC Line separator suitable for 04 / 05 nos over conductor with nuts, bolts and washers all as directed.

10

-

-

... More
Material & labour for preparation of old painted exposed external surface of steel tubular sizes 9 mtr long pole structure and applying one coat of aluminium paint with 3 strips of blue paint after scratching of old paint, cleaning of all rusted portion & writing numbering on pole with black paint all as directed.

45

-

-

... More
Material & labour for preparation of old painted exposed external surface of steel tubular sizes 11 mtr long pole structure and applying one coat of aluminium paint with 3 strips of blue paint after scratching of old paint, cleaning of all rusted portion & writing numbering on pole with black paint all as directed.

30

-

-

... More
Material & labour for removing old paint from LT panels by paint remover, cleaning by scrapping and preparing the surface and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer and writing work as per existing pattern complete all as specified and as directed.

44

-

-

... More
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of ACSR conductor all as directed.

50

-

-

... More
Receiving and attending complaints from Complaint Section / JE / Engr-in-charge by any mode of communication & attending the same within 2 hours. This item is inclusive of all the preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues including removing carbon deposits (if any), cleaning of lugs/glands etc., meggering of cables, making temporary connections (as required), removing soil and restoring back the power supply all as directed at site. Note:- 1. The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 2 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment. 2.Record of Complaint slip shall be submitted along wth claim for payments.

300

-

-

... More
Supply, laying, testing and commissioning of unarmoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor twin core of size 10 sq mm laid on wall/pole etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. including taking down old cable complete all as directed.

400

-

-

... More
Shifting of Panel / Transformer / HT Switchgear / RMU to a distance not exceeding 5 Kms from power house/substation / any place to the required place, including disconnecting and necessary connection and testing after shifting complete all as directed by Engineer in Charge.

12

-

-

... More
S & F in replacement of new tubular poles 9 mtr long swaged type 410, SP 31 with cast iron base plate, final taper plug, bolts, nuts & screws etc. including necessary earth work , PCC foundation and applying two coat of aluminium paint with 3 strips of blue paint and writing pole number with black paint complete all as specified and directed by Engineer in Charge. Note:- PCC as in foundation and coping shall be measured and paid seperetely under respective items.

60

-

-

... More
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation of LT pole , Stay assembly complete all as specified and directed by Engineer in Charge.

8

-

-

... More
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping of LT pole finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.

1.23

-

-

... More
M & L for replacement of street light timer panel including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors, micro controller suitable for outdoor use IP 55 having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, high voltage trip and auto reset having specification 230 Volts, 50 Hz with all connected accessories 3 phase complete all as specified and directed

3

-

-

... More
S&F in replacement of energy saving & envirnment friendly LED street light fitting made out of pressure die cast anodized alumnium housing having rating 60 watt wih high efficiency poly carbonate UV stablized cover with integrated lens to ensure asymmetrical light and over all IP 65 protection complete all as specified by Engineer in Charge. Cat part No. BRTFG 60W LED V3 WW of Bajaj or equivalent model in Philips/Havels/Wipro as approved by GE

28

-

-

... More
All as per item no. 64 here in before but street light fitting of 90 watt complete , Cat Part- BRTFG 90W LED IWW of Bajaj or equivalent model in Philip/Havels/Wipro as approved byGE

28

-

-

... More
Supply ,fix and in replacement 100/110 watt LED Flood light fitting with high lumnius efficienc, protected to IP 65 with front toughend glass with all necessary accesoies required effective range including necessary mounting arrangement such as flate iron clamp, nut ,bolts & washer etc. complete all as specified and directed by Engineer in Charge. Cat Part- No. BJFL 100W LED I of Bajaj or equivalent model in Philips/Havels/Wipr as approved by GE.

28

-

-

... More
Supply ,fix and in replacement 120 watt LED Flood light fitting with high lumnius efficienc, protected to IP 65 with front toughend glass with all necessary accesoies required effective range including necessary mounting arrangement such as flate iron clamp, nut ,bolts & washer etc. complete all as specified and directed by Engineer in Charge. Cat Part- No. BJFL 120W LED I of Bajaj or equivalent model in Philips/Havels/Wipr as approved by GE.

28

-

-

... More
Supply fix in relacement of energy saving, envirnment friendly & robust IP 65 protected LED flare High Bay of rating up to 150 watt light suitable for ceiling suspended type for better illumination and working envirnment complete all as specified and directed by Engineer in Charge, Cat part No. BGHBM 150W LED XE of Bajaj or equivalent model in Philips/Havels/Wipro as approved by GE.

28

-

-

... More
M&L for repair and maintinance of 60-90 watt LED street light /Security light/Flood light driver of existing make and size with suitable electronic circuit complete all as directed by Engineer in Charge.

32

-

-

... More
All as per item no. 69 but for 100-120 watt complete all as directed by Engineer in Charge.

32

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.