Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date3 Dec 2024
Closing Date28 Dec 2024
Tender Amount₹ 43,36,000
Costs
EMD
₹ 86,750Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686772_1Bid Award Id
ViewTender No
8240/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4. complete all as specified and directed.
12
-
-
... More
M&L for Brickwork with fly ash brick in CM 1: 6 straight or curved on plan exc 6 m mean radius complete all as specified and directed.
22
-
-
... More
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4. complete all as specified and directed.
5
-
-
... More
M&L providing RCC 1:2:4, type B1 using 20mm graded aggregate as in RCC Flue for Incinerator, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,kerb of interlocking tiles and the like including fomwork (straight or curved) complete all as specified and directed.
2
-
-
... More
S&F Mild steel bars (TMT bars) 6 to 8 mm dia cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips in reinforcement for concrete complete all as specified and directed.
80
-
-
... More
M&L for mild steel TMT bar 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
1029.75
-
-
... More
M&L for mild steel TMT bar 5 mm and over dia in stirrups, spacers , and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
240
-
-
... More
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering doors, etc. to prepared for hanging or sliding with and including either hooks and hinges or steel hangiong door fittings (exclusive of steel, sheeting rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
700
-
-
... More
M&L for rendering 15 mm th in CM 1:4 on fair faces of brickwork or concrete surfaces mixed with water proofing compound on top layer as per manufacturer instruction complete all as specified and directed.
Note:- Water Proofing compound Shall be measured and paid seperately.
100
-
-
... More
M&L 15 mm thick cement plaster on brick surfaces or concrete surfaces in cm (1:4) including finishing the surface even and fair complete all as spd and directed.
210
-
-
... More
Supply only Integral Water proofing Compound complete all as specified and directed.
3.5
-
-
... More
S&F 1.00 mm thick mild steel, plain, black sheet in wall in cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angels, etc. as required complete all as specified and directed.
3
-
-
... More
M & L for Preparation of new steel surfaces of any description, over 10cm in width of girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
722
-
-
... More
M&L for three coat of white wash on wall including preparation of new treated plastered wall surface complete all as specified and directed.
100
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
34.48
-
-
... More
Removing excavated surplus material (soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
27.52
-
-
... More
M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
10.88
-
-
... More
M&L 40 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in flooring and finished even and smooth without using extra cement complete all as specified and directed.
15
-
-
... More
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment of approved design and patterm laid over a layer of 25 mm thick sand cushion including filling the joint with sand complete all as specified and directed.
130
-
-
... More
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in hard / dense soil, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
103
-
-
... More
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
20.34
-
-
... More
S & F of steel work as in tubular trusses purlin (MS Square / rectangular / round of various sizes) including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
3344
-
-
... More
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
400
-
-
... More
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
24
-
-
... More
M&L 75 mm thick plain cement concrete (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub-base / sub floors complete all as specified and directed.
145
-
-
... More
M&L Formwork to sides of concretefoundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similarwork;vertical or to batte all as spd and directed.
12.2
-
-
... More
M&L for Form work to sides of pillars, struts, columns and stanchions and similar work square, rectangular rough finished surfaces of concrete all as spd and directed.
43
-
-
... More
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings,girders,bressummers,lintels,cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc all as spd and directed.
9
-
-
... More
M & L for providing reinforced cement concrete design mix M-20 (20 mm aggregate ) as in foundation, including rafts, footings, foundation beams; plinth beams; bases for columns, basement slab,underreamed files and mass concrete etc. all as spd and directed.
6.8
-
-
... More
M & L for RCC design mix M-20 (20 mm aggregate )as in columns,pillars, post and struts etc. complete all as specified and directed.
3.1
-
-
... More
M & L for providing reinforced cement concrete design mix M-20, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
0.5
-
-
... More
M & L for preparation of un-decorated plastered surface of walls and applying two coats of cement base paint over a one coat of white wash complete all as specified and directed.
192
-
-
... More
S & F mild steel work as in flat tie for post and struts in fencing including cutting tops to shape as directed ,drilling holes ,notching wire etc, flat iron including drilling holes , confirming to Fe 410-O or Fe -310-O complete all as specified and directed
346.92
-
-
... More
S & F, rolled mild steel as in angle, post without connecting plate etc, cut to length ordinary Gde Fe-410.0 or Fe -310.0 complete all as specified and directed
1475.7
-
-
... More
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other ends of screwed both ends each screwed end to be fixed with washer and one hexagonal or square nut length of the bolt exc 10 cm and n.exc 15 cm long dia of shank 10 mm complete all as specified and directed.
30.45
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed
533.54
-
-
... More
Supplying only chain link fencing complete all as specified and directed
1899.4
-
-
... More
S &F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
12
-
-
... More
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
550
-
-
... More
Supply and Laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole complete of size 35 Sqmm 3.5 Core complete all as specified and directed.
150
-
-
... More
M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed.
11
-
-
... More
M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and directed.
1120
-
-
... More
S&F of High galvanized mast light 16 meter height suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height complete all as specified and directed.
1
-
-
... More
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
9
-
-
... More
Supply & fixing PVC insulated & sheathed stranded copper cable 5 core of cross sectional area 2.5 sq mm for proving necessary electrical connection from feeder pillar box to light fittings including with suitable size copper lugs complete all as specified and directed.
100
-
-
... More
M&L of Earthing with Galvanised Earth Plate Electrode 600x600x6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected to galvanised earth Strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel, GI Pipe 20mm medium grade all as shown in Electrical Plate No. 3 of MES Schedule Part-I including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and and Testing on Completion, complete all as per specified and as directed.
3
-
-
... More
M&L for Galvanised Steel Tubing Pipe 40 mm bore (dia), light grade with Bend, laid in Trenches or under Roads crossing/Flooring/Culverts/Footpath complete all as specified and as directed.
12
-
-
... More
Supply, install, commissioning and testing cubical type outdoor type LT Panel box, made out of 3.15 mm thick mild steel sheet, of size not less than 600 mm x 500 mm x 300 mm with mild steel angle iron frame and legs (of length 400 mm) of section 40 mm x 40 mm x 6 mm thick, with front openable door (with locking arrangement) duly powder coat painted over a coat of red oxide primer, with provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x 10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) complete all as directed by the Engr-in-Charge comprising of the following accessories :-
1
-
-
... More
(a) MCB, TPN 40 Amps, 50 Hz, 415 Volts - 01 Nos (b) Aluminium bus bar 100 Amps capacity - 04 Nos
(c) LED type indication lamp R Y B - 01 set.
(d) Contactor 40 Amps, 3 pole, 415 volts. AC - 01 No
(e) Auto/Manual Selector Switch - 01No (f) ON/OFF Push Button - 01 No
(g) Change over Switch for Reverse-Forward for operation Lights for repair/maintenance etc. Note:-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
-
-
-
... More
M&L for concealed point wiring with 1.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with multistranded copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20 mm sunk pressed steel terminal box/ MS modular box suitably flushed to wall with 3mm thick Hylum sheet cover/ white colour modular plate with cover for housing switch, socket regulator etc fixed with screws & cup washers incl. making good for One light/fan point/exhaust fan ponint controlled by one switch 5/6 Amp one way complete all as specified and directed.
20
-
-
... More
All as per item no.53 here in before but for socket outlet 3/5 pin 5 amp. on the same board complete all as specified and directed.
2
-
-
... More
Supply and Fixing Modular switches 1 way, 6 A, 1 module complete all as specified and directed.
22
-
-
... More
Supply and Fixing Modular sockets 6 A,-2/3 pin combined 2 module complete all as specified and directed.
2
-
-
... More
Material and labour for point wiring with single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered with modular plate and cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed.
21
-
-
... More
Supply and Fixing Modular switches 1 way, 16 A, 1 module complete all as specified and directed.
21
-
-
... More
Supply and Fixing Modular sockets 6 A/ 16 A,-2/3 pin combined 2 module complete all as specified and directed.
21
-
-
... More
Supply and Fixing ceiling rose PVC Polycarbonate isolated body 2/3 terminals 230 Volts complete all as specified and directed.
22
-
-
... More
Supply and Fixing MCB SPN 16 Amps 240 volts complete all as specified and directed.
2
-
-
... More
Supply and Fixing MCB SP 6 to 32 Amps 240 volts, 'B' curve 10 kA. complete all as specified and directed.
4
-
-
... More
Supply and Fixing flush sheet metal enclosure SPN DB 4 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with BUS Bar earth bar and neutral links complete all as specified and directed.
2
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified including testing after completion.
2
-
-
... More
S & F Ceiling fans complete with blades, down rods and accessories, 230V, 1200mm sweep, Min air delivery CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
20
-
-
... More
Supply, installation, commissioning of Deep freezer glass top 400 Litre capacity having double door single phase 240 volt, 50 Hz complete all as specified and directed by the Engr-in-Charge.
19
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed.
19
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements