Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Oct 2024
Closing Soon18 Nov 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681621_1Tender No
CWE/JHA/J/TOKEN/63 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Power transformer upto 5 MVA, 33 KV / 11 KV
2
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
5
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
6
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
7
-
-
Shifting of the transformer from plinth / pole structure inside the fence area with the help of suitable crane and transporting to workshop for carrying out necessary repairs and bringing back and re-installing in its original place complete all as specified and directed for the following capacity of transformers:-
Note : Repairs required shall be measured and paid separately under relevant items of BOQ.
-
-
-
Power transformer upto 5 MVA, 33 KV / 11 KV
2
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
5
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
6
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
7
-
-
Supply and fix in replacement of HV side porcelain transformer bushing with brass stud, nuts, bolts & washers including oil seal and gaskets suitable for following rating of step down transformers complete all as specified and directed.
-
-
-
Power transformer upto 5 MVA, 33 KV / 11 KV
4
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
6
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
8
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
15
-
-
Supply and fix in replacement of LV side porcelain transformer bushing with brass stud, nuts, bolts & washers including oil seal and gaskets suitable for following rating of step down transformers complete all as specified and directed.
-
-
-
Power transformer upto 5 MVA, 33 KV / 11 KV
4
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
7
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
9
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
14
-
-
Opening the LV side cable box and disconnecting the LT cables and Supply and fix in replacement of oil seal and gasket suitable for LV side bushing of 11KV/433V transformer of rating up to 500 KVA complete all as specified and directed.
13
-
-
M&L for preparation of old painted surfaces of outdoor/indoor type power / distribution transformers and painting with synthetic enamel paint of approved colour using spray painting machine / spay gun through out externally and writing machine number in white colour on black background complete all as specified and directed for following rating of transformers:-
-
-
-
Power transformer upto 5 MVA, 33 KV / 11 KV
1
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
7
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
10
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
15
-
-
Taking out complete core from transformer, cutting and removing burnt out winding [primary (HV) and secondary (LV)] and re-winding the same with super enameled copper conductor of gauge wire size 1.5mm together with insulation materials, applying varnish, pre-heating in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and directed for Transformer of capacity upto 500 KVA of any make.
510
-
-
Disconnecting the defective transformer of any rating from HV side, LV side and earthing connections and carefully shifting the trolley mounted mobile type transformer of capacity 400 KVA from one location to other location within the Jhansi Cantt Area including AAU & Caleb Vihar with the help of tractor or any suitable means of transportation and making all HV, LV and earthing connections and testing complete all as specified and directed.
15
-
-
Supply and fix in replacement of breather assembly complete with new silica gel and fixing accessories suitable for following rating of existing transformers of any make:-
-
-
-
Power transformer upto 5 MVA, 33 KV / 11 KV
3
-
-
Distribution transformer up to 100 KVA, 11/0.433 KV
12
-
-
Distribution transformer 160 KVA to 250 KVA, 11/0.433 KV
20
-
-
Distribution transformer 300 KVA to 500 KVA, 11/0.433 KV
18
-
-
Supply and replace silica gel into the breathers of power / distribution transformers of any capacity and make complete all as specified and directed.
110
-
-
Supply and fix in replacement of MCCB 400 A ,4 pole ,50 KA (ICs = 100% ICu) with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables complete all as specified and directed.
3
-
-
Supply and fix in replacement of MCCB 500 A ,4 pole ,50 KA (ICs = 100% ICu) with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables complete all as specified and directed.
3
-
-
Supply and fix in replacement of MCCB 630 A ,4 pole ,50 KA (ICs = 100% ICu) with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables complete all as specified and directed.
3
-
-
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
2
-
-
Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed.
350
-
-
M&L in replacement of Power Cables, Aluminum Stranded Conductor 400 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
20
-
-
All as per item No. 18.00 here-in-before but of size 300 sqmm, 3 1/2 core complete all as specified and directed.
400
-
-
All as per item No. 18.00 here-in-before but of size 240 3 1/2 core complete all as specified and directed.
320
-
-
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed.
270
-
-
Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed.
Note: Punned down thickness (18 cm) only shall be measured for the purpose of payment.
81
-
-
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
200
-
-
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
70
-
-
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.
1940
-
-
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) after laying of pipes lines/cable and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
10
-
-
Supply and fix in replacement of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles and ceiling or laid in trenches/ floors for cable protection complete all as specified and directed.
50
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
4
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
4
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
3
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
3
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed.
5
-
-
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm complete all as specified and directed.
5
-
-
Supplying, Installing, Connecting and testing in replacement of 11 KV 200 Amps triple pole gang operated air break switch having 12 Nos post insulator with earthing switch rotating type for horizontal/ vertical operation mechanically operated 3 rows type mounted on insulator (including insulators) and steel frame with operating mechanism consisting of operating rod of 25mm bore medium grade GI pipe of suitable length to operated from ground level including locking arrangement with pad lock of godrej make with three Nos of keys including 11 KV swing out explusion fuses (drop out type) of 10 Amps complete all as specified and directed.
1
-
-
M&L for lighting arrestors non linear type with all fitting distribution class, discharge capacity 65 kilo Amps, current rating 5 KA suitable for 11000 volts complete connecting with ACSR jumpers from LA to air brake switch with PVC sleeves complete all as specified and directed.
1
-
-
M&L in repair/replacement for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
6
-
-
Supply and fix in repair/ replacement of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, brown, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
4
-
-
Supply and fix in repair/replacement of ACSR conductor for HT/LT overhead line and proper stringing to required tension and sag including binding with new aluminium binding wire of suitable size complete all as specified and directed.
1
-
-
Supply and fix of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
1
-
-
M&L for pruning of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified and directed.
Note: The item will be measured in span length between poles. The approx span length is 50m.
150
-
-
Material and labour for Surface dressing not exc 15cm deep in any type of soil and site clearance including cutting and removing of plants/bushes, leveling of surface area, throw wastage material out of fencing area/ compound wall up to 50m distance at sub station areas / pump House areas complete all as specified and directed.
320
-
-
Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 400 sqmm, 3 core, 33000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed.
30
-
-
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300- 400 Sqmm complete all as specified and directed.
6
-
-
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed.
4400
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%