Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Nov 2024
Closing Soon30 Nov 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660416_2Tender No
GE/W/LKO/55 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per Item No 2 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
40
-
-
All as per Item No 2 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
6
-
-
All as per Item No 2 above but for One light point controlled by two two way switch complete all as specified and as directed.
4
-
-
All as per Item No 2 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
70
-
-
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into and including suitable size surface conduit/casing caping, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
120
-
-
All as per Item No 8 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
60
-
-
All as per Item No 8 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
30
-
-
All as per Item No 8 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
6
-
-
All as per Item No 8 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
50
-
-
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into existing conduit, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and as directed.
160
-
-
All as per Item No 13 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
40
-
-
All as per Item No 13 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
20
-
-
All as per Item No 13 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
6
-
-
All as per Item No 13 above but for One light point controlled by two 2 way switch complete all as specified and as directed.
2
-
-
All as per Item No 13 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
50
-
-
M&L for point wiring with single core FRLS PVC insulated 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) drawn in and including non metallic rigid PVC concealed conduit, medium grade ISI marked not less than 20 mm dia, concealed in wall, ceiling with saddles, screw & Plugs with all fittings including tee, junction boxes and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm and terminated in and including sunken box for modular switches/sockets, regulators etc complete all as specified and as directed. (a) One light/fan point controlled by one switch
60
-
-
All as per item No 19 above but for one socket outlet point 5 Amp on an independent board complete all as specified and as directed.
20
-
-
All as per item No 19 above but on the same board complete all as specified and as directed.
6
-
-
All as per Item No 19 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
18
-
-
All as item No 19 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board complete all as specified and as directed.
16
-
-
S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
680
-
-
S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
170
-
-
S&F switch piano flush button single pole two way 5 Amp 240 volt complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
12
-
-
S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and16 Amp, 230 volts complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
170
-
-
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6Amp, 230 volts complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
250
-
-
S&F fan regulator electronic,step up socket type,230 volt,125 W and conection complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
80
-
-
S&F modular switches 1 way 6A,1 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
86
-
-
S&F modular switches 1 way 16A,1 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
16
-
-
S&F modular 6 A sockets-5 pin 2 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
26
-
-
S&F modular 6A/16A sockets-3/5 pin combine 2 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
16
-
-
S&F Modular white cover plate with frame 8 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
15
-
-
S&F Modular white cover plate with frame 6 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
10
-
-
S&F Modular white cover plate with frame 4 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
10
-
-
S&F Modular white cover plate with frame 3 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
36
-
-
S&F Modular white cover plate with frame 2 module complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
8
-
-
S&F modular bell push single pole one way 6/10 Amp, 240 volt,1 module, fuesh type complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
6
-
-
Supply and fix modular type blanking plates, one moudle complete all as specified and directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
110
-
-
Supply & fix modular fan regulator 120/100 W, 2 Module for ceiling fan fixed, in board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and as directed.
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
20
-
-
S&F ceiling rose surface bakelite three terminal complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
430
-
-
S&F bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
18
-
-
S&F call bell AC single pole 240 volt ding dong Type complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
18
-
-
S&F angle type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
80
-
-
Supply & fixing bulk head light fitting made from cast aluminium body with heat resistance pressure die cast housing, IP-65 and IK 08 protection cover suitable for bulk head fitting integrated type 10/7W LED, 6500K , 100 lumens/watt including inbuilt electronic driver complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
25
-
-
Supply and fixing wall/surface mounting luminaires (Mirror Light) integrated LED Batten( 2 feet) 8/10 W, 6500 K, 230V , minimum 120 lumens/watt,CRI 80 minimum Burning Hrs 25K with extruded aluminium housing & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements all as per specified and directed by Engr-in-charge. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
300
-
-
Supply and Fixing wall/surface mounting luminaires integrated LED Batten 18/20 W, 6500 K,120 lumens/watt , 230V CRI 80 with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver, 25k burning hours ,2.5 KV surge protection complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements all as per specified and directed by Engr-in-charge Makes shall be provided group-I cat as per latest approved make given by HQ CECC
820
-
-
S& F in repair Decorative wall light fixture made up of Metal base, synthetic white in colour and square/round metal base with bend pipe and glass globe with nickel finish, with 01 No. 7/9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connecting arrangements all as specified and as directed. ( Note: Rates incl 01X 7/9 W LED Bulb with each fitting) Makes shall be provided group-I cat as per latest approved make given by HQ CECC
32
-
-
S&F in repairs of surface type round/ square LED 10/12W downlighter 6500K 2.5 KV inbuit surge protection minimum 110 lumens/watt, CRI 80 and 50k burning hours aluminium PDC complete all as specified and as directed.
45
-
-
S&F in repairs of recess type square/Round LED 10/12W downlighter 6500K 2.5 KV inbuit surge protection minimum 110 lumens/watt, CRI 80 and 50k burning hours aluminium PDC complete all as specified and as directed.
45
-
-
Supply and fixing LED lamp 7/9 watt, complete all as specified and as directed.
1070
-
-
S&F in repair super bright LED (2X2), 36 W, 6500 K recess mounting minimum 120Lumens/watt IP20 ,IK02 PF.9 and 4kv inbuilt surg protection CRI -80 with high efficent LED source complete all as specified and as directed.
120
-
-
Supply and fixing in repair FTL fittings with decorative LED batten made up of aluminium casting 18/20 W of size complete standard fittings and fixtures including fixing on walls/roofs/ through MS downrod suspended type with fitting arrangement including neccessary elect connection from ceiling rose to luminaries with suitable size PVC cord complete all as specified and as directed.
260
-
-
Supply and fixing in repair Material glass led tube ,voltage range 220-240v-50hz ,wattage 18/20 W surge 2.5kv ,CRI 80 POWER FACTOR _0.9 ,BURING HOURS 25K HOURS 110 L/W ,6500 K with high efficency, with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as specified and as directed.
820
-
-
S & F in repairs integrated LED type Post top lantern with high power 25/30 W LED and IP 65 and IK 05 with 4 KV Surge protection as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl neceesary electrical connection complete all as specified and as directed.
12
-
-
S&F in repair LED Building security light 20/25 Watt with high power LED source (100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed.
40
-
-
S & F in replacement of GI pipe light grade, 32 mm bore, 1.20 mtr long bend in required shape, MS clamp 40x3mm thick duly painted with two coats of synthetic enemal paint fixed on wall including bolts and nuts complete all as specified and directed.
20
-
-
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.
NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
300
-
-
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.
NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
300
-
-
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn into existing conduit complete all as specified and directed.
NOTE:- One unit length shall measured as two run of main wire and one run of earth wire.
300
-
-
Supply and fixing in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed
270
-
-
Supply and fixing in replacement for 2.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed
270
-
-
Supply and fixing in replacement for 4.0 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and directed
180
-
-
S & F three core PVC insulated FRLSH sheathed cable with 1.5 sqmm stranded copper conductor complete all as specified and as directed.
270
-
-
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed.
190
-
-
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 6.0 sqmm aluminiuam conductor complete all as specified and as directed.
170
-
-
S&F sheet metal enclosure for MCB DB double door type, TPN 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
6
-
-
S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
6
-
-
S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
6
-
-
S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
6
-
-
S&F in replacement MCB, single pole 10 to 32 Amp, 240 volts, 10 KA breaking capacity, 'B' curve complete all as specified and directed.
300
-
-
S&F MCB, in replacement single pole & neutral 63 Amp, 240 volts, 10 KA breaking capacity, 'B' curve complete all as specified and directed.
40
-
-
S&F in replacement MCB, triple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'B' curve complete all as specified and directed.
30
-
-
Supply and fixing modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
35
-
-
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and as directed. Note: MCCB & MCB to be measured and paid seprately
5
-
-
S&F MCCB 100 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and as directed.
5
-
-
S&F in replacement modular switches 1 way 6/10A,1 module, complete all as specified and as directed
40
-
-
S&F in replacement modular switches 1 way 16A,1 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
40
-
-
S&F in replacement modular switches 2 way 6A,1 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
40
-
-
S&F in replacement modular bell push ,1 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
S&F in replacement modular 6 A sockets-2/3 pin combine 2 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
40
-
-
S&F in replacement modular 6A/16A sockets-2/3 pin combine 2 module complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
S&F in replacement fan step regulator modular 100/120W, 2 module, complete all as specified and as directed Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
20
-
-
S&F in replacement modular white cover plate with frame 2 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
Same as item ser no 85 here in before but 3 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
Same as item ser no 85 here in before but 4 module, complete all as specified and as directed
Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
Same as item ser no 85 here in before but 6 module, complete all as specified and as directed Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
Supply and fixing PVC casing and caping, 15mm wide complete all as specified and as directed
150
-
-
Supply and fixing PVC casing and caping, 20mm wide complete all as specified and as directed
140
-
-
S & F in replacement of switch piano flush button single pole one way 5/6 Amp 240 volt complete all as specified and as directed
750
-
-
S & F in replacement of switch piano flush button single pole one way 15/16 Amp 240 volt complete all as specified and as directed
350
-
-
S&F in replacement of socket outlet flush type multipurpose 2 in 1, 3 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and as directed
350
-
-
S&F in replacement of unservicable socket outlet flush type multipurpose 2 in 1, 6pin 5 .Amp, 230 volts complete all as specified and as directed
320
-
-
S&F in replacement of switch socket outlet combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and as directed
120
-
-
S&F in replacement bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed
50
-
-
S&F in replacement call bell AC single pole 240 volt ding dong Type complete all as specified and as directed
60
-
-
S&F in replacement high range up to 40 mtr, cordless call bell with wireless remote including batteries complete all as specified and as directed
6
-
-
S&F in replacement angle/batten type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed
260
-
-
S&F in replacement PVC gang box fitted with and including piano type switch 5 A and socket 5 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed
25
-
-
S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed
25
-
-
S & F rectangular laminated hylum sheet top cover 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) for switch sockets of size' (125mmx125mmx3mm) complete all as specified and as directed
25
-
-
Same as item 102 here in before but (200mmx125mmx3mm) complete all as specified and as directed
25
-
-
Same as item 102 here in before but (225mmx275mmx3mm) complete all as specified and as directed
Note :- 1. For Item No 46 to 104 day to day complaint will have to be rectified by the contraxctor with in two day (Up To 40 Nos of complaint per day).
2. Penalty will be made Rs 100 /day for delay beyond two day.
3. Complaont will be collected by the Rep of contractor Supervisor from AGE EM Yard.
25
-
-
M & L in replacement for pressed steel concealed terminal switch boxes not less than 1.6mm thick of 125x125x3mm (5x5)size factory made duly painted inside and outside with one coat red oxide primer, and making good disturbed surfaces of walls, floors,etc complete all as sepcified and as directed.
25
-
-
M & L replacement for pressed steel concealed terminal switch boxes not less than 1.6mm thick of 200x 125x3mm (8x5)size factory made duly painted inside and outside with one coat red oxide primer, and making good disturbed surfaces of walls, floors,etc complete all as sepcified and as directed.
20
-
-
M & L replacement for pressed steel concealed terminal switch boxes not less than 1.6mm thick of 225x175x3mm (10x7)size factory made duly painted inside and outside with one coat red oxide primer, and making good disturbed surfaces of walls, floors,etc complete all as sepcified and as directed.
20
-
-
M & L of Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and directed .
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%