Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date26 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 43,67,000
Costs
EMD
₹ 87,400Document Cost
₹ 500Tender Fee
Refer Documents
Summary
8124/sar-t-31/2024-25 Addn/altn To Bldg No. P-311 At Af Station Sarsawa Under Ge (af) Sarsawa
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662145_1Bid Award Id
ViewTender No
8124/SAR-T-31/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
25.79
-
-
... More
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified& directed by Engr-in-Charge.
34.21
-
-
... More
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
37.5
-
-
... More
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
0.15
-
-
... More
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
131.6
-
-
... More
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
63
-
-
... More
M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed.
71.28
-
-
... More
M&L for Reinforced cement concrete (Design mix M-25 ) (20 mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
Note :- Reinforcement shall be measured and paid for separately.
22.98
-
-
... More
M&L for Reinforced cement concrete (Design mix M-25 ) (20 mm graded stone aggregate) Beams, cantilevers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge.
Note :- Reinforcement shall be measured and paid for separately.
6.3
-
-
... More
M&L for Reinforced cement concrete (Design mix M-25 ) (20 mm graded stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge.
Note :- Reinforcement shall be measured and paid for separately.
5.35
-
-
... More
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
3693.9
-
-
... More
M&L for mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
1500
-
-
... More
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
24.15
-
-
... More
M&L for rendering 10mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick work of walls including finishing the surface fair and even complete all as specified.
176.28
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemper over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
176.28
-
-
... More
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified.
Note : - Supply only water proofing admixture shall be measured and paid for separately.
176.28
-
-
... More
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Make : Nerolac Excel top guard (10 years product warranty)/ Asian paint ultima protect (10 yrs product warranty)/ Berger weather coat long life (10 yrs product warranty).
176.28
-
-
... More
Supply only integral liquid water proofing compound (ISI marked).
8.18
-
-
... More
M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
400
-
-
... More
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate), as in sub base all as directed by Engineer-in-charge.
250
-
-
... More
M&L Vitrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.36 sqm, but not 0.42 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick cement screeding in CM 1:6 Complete all as specified and directed by Engr-in-Charge.
250
-
-
... More
M&L Vitrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.36 sqm, but not 0.42 sqm, in vertical surfaces as skirting and dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 10mm thick rendering in CM 1:4 Complete all as specified and directed by Engr-in-Charge.
105
-
-
... More
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed CM 1:6 complete all as specified& directed by Engr-in-Charge.
10
-
-
... More
S&F anodized aluminium frame with power coating (minimum thickness 50 micron) and other sections for doors, windows, ventilators, partitions, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
750
-
-
... More
S&F anodized aluminium door shutters, aluminium section weighing 0.55 kg/m, with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed.
2
-
-
... More
S&F door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width aand weight between 36 to 60 Kg and fixed complete all as specified & as directed.
1
-
-
... More
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m,with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.
5
-
-
... More
S&F 10mm thick toughned glass as in hinged doors, partitions ,automatic doors and similar work including cutting to shape, drilling, holes required.
90
-
-
... More
S&F 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling, holes required.
4
-
-
... More
S&F 25mm dia and 16 gauge thickness Stainless steel Chrome finish toughened glass door handles 305mm long complete all as specified and directed.
4
-
-
... More
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
2
-
-
... More
Supply and fixing brass mortice lock, vertical type/horizontal type , size 100mm, 4 Levers with escutcheon plates & two keys fixed in aluminium frame complete all as specified.
2
-
-
... More
S & F of venation blinds( super quality) to window openings of the following Makes-MAC,Siesta or equivalent.
50
-
-
... More
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
60
-
-
... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
2.9
-
-
... More
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified.
100
-
-
... More
M&L Steel work in tubular trusses including, plates , nut/bolts, fastners, special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 Complete all as specified
3825
-
-
... More
M & L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
198.9
-
-
... More
M&L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
324
-
-
... More
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge.
24.3
-
-
... More
M&L for false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 5mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c and applying two coats of Oil Bound distemper to the ceiling board complete all as specified and as directed by Engineer-in-Charge.
250
-
-
... More
M&L for Solid PVC Wall Lining/Wall penelling consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
75
-
-
... More
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
252
-
-
... More
Supply & fix wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge
4
-
-
... More
M & L for concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes modular type including earth dolly with cover plate with frame of modular type of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
One light / fan point controlled by one way switch
12
-
-
... More
All as per above item No-48 here in before but One 5 Amp socket outlet on independent board.
7
-
-
... More
All as per above item No-48 here in before but One 5 Amp socket outlet on same board.
2
-
-
... More
All as per above item No-48 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
10
-
-
... More
S & F of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.
Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
50
-
-
... More
S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
20
-
-
... More
S&F socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
10
-
-
... More
S&F switch 6 amps modular type one one way complete all as directed.
21
-
-
... More
S&F switch 16 amps modular type one one way complete all as directed.
10
-
-
... More
S&F socket outlet 6A-2/3 pin combined 2 module modular type complete all as specified and directed.
9
-
-
... More
S&F of modular type AC Box with 16 Amp plug ,16 Amp modular type socket 2 module and one MCB SP 20 Amps including 3 module plate frame and PVC sunken box complete all as specified and directed.
3
-
-
... More
S&F of Double door distribution board 6 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) cost of Blank if required shall be included in quoted rate).
1
-
-
... More
S&F MCB TPN 63 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
1
-
-
... More
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
20
-
-
... More
S & F in enviroment friendly recess/pendent mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF0.95 , lumen efficacy100 lm/W, THD10% operating range 220v to 240V,CRI80, Colour Temerature 3500 K (Warm White) including connection with existing wire and all accessaries all as specified and directed.
8
-
-
... More
Supply and fixing Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
2
-
-
... More
Supply and install hi wall split Type Airconditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR with precharged CFC free refrigerant with hot and cold function all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
3
-
-
... More
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
27
-
-
... More
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
15.45
-
-
... More
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
8.1
-
-
... More
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
0.87
-
-
... More
M&L for GI pipes 40 mm dia light grade for cable protection in trenches / poles complete all as specified and as directed.
20
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core all as specified and directed.
110
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements