Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Apr 2024
Closing Date29 Apr 2024
Tender Amount₹ 42,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw all as directed and specified.

250

-

-

... More
S&F in replacement aluminum strip 25 x 3 mm with saddle of porcelain insulator and fixing screws not less than 50 mm long with PVC plug & gutties etc. on roof/wall and connecting from earth pit the lightning rods point on Hanger at height upto 11 mtr etc all as specified and directed

1550

-

-

... More
Refixing of hanging Aluminium/GI strip on same location with saddles/insulators, screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors on Hanger at height upto 11 mtr all as specified and directed

4520

-

-

... More
Supply and fixing GI Pipe 40mm Light grade , for Earth strip protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,.

150

-

-

... More
M&L for earthing in replacement complete with chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 2 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS bolts & washers as required and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.

12

-

-

... More
M&L for earthing in replacement complete with galvansided steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.

58

-

-

... More
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing on around lighting protection GI/ aluminium strips to restrict monkey claiming/ demaging pitch not exceeding 3 inch complete all as specified and directed.Note:- 1. The above maint work is required to be carried out in hangers at the height 12 to 15 Mtrs. 2. The cost of required necessary TNP & Safty features to be included in the quoted units rates by the contractor.

120

-

-

... More
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etcexcluding tubelight fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed.

375

-

-

... More
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.

250

-

-

... More
All as per item No-12 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.

25

-

-

... More
All as per item No-12 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.

50

-

-

... More
All as per item No-12 here in before but point wiring for one six pin socket outlet 15 & 5 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed. NOTE-For item no 12 to 15-: (i) the new metal flush mounting sunken boxes and its covering plates etc shall be measured and paid for separately under respective item of this schedule. (ii)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (iii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iv)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)

50

-

-

... More
Supply and fixing in replacement modular metal GI flush box 3 module as per site requirement suitable for 20mm dia conduit with and fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.

75

-

-

... More
All as above item No -16 but modular metal flush box of 4/5 module

50

-

-

... More
All as above item No -16 but modular metal flush box of 6 module

20

-

-

... More
All as above item No -16 but modular metal flush box of 12 module

15

-

-

... More
All as above item No -16 but modular metal flush box of 18 module

20

-

-

... More
Supply and fix in replacement modular white cover plate with frame 3 module for mounting modular switches,sockets and regulators etc.

75

-

-

... More
All as per above item No- 21 But modular white cover plate with frame 4/5 module

50

-

-

... More
All as per above item No- 21 But modular white cover plate with frame 6 module

20

-

-

... More
All as per above item No- 21 But modular white cover plate with frame 2x 6 module

15

-

-

... More
All as per above item No- 21 But modular white cover plate with frame 3x 6 module

20

-

-

... More
Supply and fix in replacement switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.

325

-

-

... More
Supply and fix in replacement socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed.

75

-

-

... More
Supply and fix in replacement switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed.

50

-

-

... More
Supply and fix in replacement socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed.

50

-

-

... More
Supply & fix in replacement rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed.

20

-

-

... More
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.

4

-

-

... More
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.

80

-

-

... More
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.

140

-

-

... More
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.

4

-

-

... More
Supply & fix commiosnig and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed.

8

-

-

... More
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.

80

-

-

... More
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.

300

-

-

... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.

20

-

-

... More
Supply & fix in replacement, outdoor Security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.

10

-

-

... More
Supply & fix in replacement, surface mounting type bulkhead 10 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.

20

-

-

... More
Supply & fix in replacement, surface round mounting type 12/15 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.

70

-

-

... More
Supply & fix in replacement, surface square mounting type 12 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.

30

-

-

... More
Supply & fix in replacement, surface/ recased mounting type 34 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.

20

-

-

... More
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .

350

-

-

... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 10 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.

50

-

-

... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.

150

-

-

... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.

150

-

-

... More
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces.

8

-

-

... More
Supply and fix in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .

4

-

-

... More
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed.

4

-

-

... More
Supply and fix MCCB 4 pole 125 Amp, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB.

4

-

-

... More
Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.

4

-

-

... More
Supply & fix MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.

48

-

-

... More
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.

24

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.