Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date30 Nov 2024
Closing Date23 Dec 2024
Tender Amount₹ 32,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & laying of best quality of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and as directed.

5

-

-

... More
Re-laying of old serviceable bricks as in cable protection cover, laid flat and dry in trenches over the cable length of brick laid prependicular to the direction of cable complete all as specified and as directed. Note:- Old serviceable bricks obtained from taking out shall be used under this item.

4

-

-

... More
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as specified and as directed. Note : Punned thickness shall only be considered for payment.

78.25

-

-

... More
Taking out old serviceable/unserviceable LT UG cables of size 10 to 70 Sq mm 3.5/4 Core from trenches, poles/walls/ducts and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and as directed.

740

-

-

... More
Taking out old serviceable/unserviceable LT UG cables of size 95 to 400 Sq mm 3.5/4 Core from trenches, poles/walls/ducts and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and as directed.

640

-

-

... More
Laying only and connection of serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.

-

-

-

... More
10 sqmm to 70 Sqmm 3.5/4 core

210

-

-

... More
95 sqmm to 400 Sqmm 3.5/4 core

120

-

-

... More
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :-

-

-

-

... More
50 Sq mm 3.5 core

250

-

-

... More
70 Sq mm 3.5 core

280

-

-

... More
95 Sq mm 3.5 core

310

-

-

... More
120 Sq mm 3.5 core

210

-

-

... More
Supply and fixing in replacement of MS Chequered plate of 5 mm thick or over in thickness in available of Fe - 290 Gde E165 and fixed in substation building including making provision for lifting the plate from duct complete all as directed.

250

-

-

... More
M&L for disconnecting all incoming and outgoing electric connection of stabilizer,opening from top and taking out U/S parts and fixing of new spare parts to make it functional etc complete all as specified and directed. Note Quoted rate shall be deemed to be included the following (i) Taking out transformer oil for repair of voltage stabilizer and repouring after repair of stabilizer. (ii) New spare part shall be measured and paid as supply only under respective items here in after.

6

-

-

... More
Supply only following parts for replacement of stablizer parts-

-

-

-

... More
(a) Push button switch

2

-

-

... More
(b) Auto manual switch

2

-

-

... More
(c) DPDT switch

2

-

-

... More
(d) micro switch

2

-

-

... More
(e) Panel lamp

2

-

-

... More
(f) Potentiometer

2

-

-

... More
(g) Voltmeter (Digital/Analog)

2

-

-

... More
(h) Amp meter with C.T. (Digital/Analog)

2

-

-

... More
(i) Electronic circuit card (P.C.B)

2

-

-

... More
(j) Micro processor based control card for each phase

2

-

-

... More
(k) P.C.B. holder

1

-

-

... More
(l) Trigger Transformer

1

-

-

... More
(m) Rotary Switch 5 Amp for RYB Phases

2

-

-

... More
(n) Servo motor 3 K.G torque

1

-

-

... More
(o) Servo motor 10 K.G torque

1

-

-

... More
(p) R.C. network for 3KG motor

2

-

-

... More
(q) R.C. network for 10KG motor

2

-

-

... More
(r) Carbon Brush

1

-

-

... More
(s) Transformer Oil

2

-

-

... More
M&L for dismantling the cable connection of four pole ACB of capacity upto 1250 Amp, 415V 50Hz of as per existing make, strip opening the ACB, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance:- (a)   Cleaning the insulation parts including bushing with CTC solution. (b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer’s instructional manual. (c) Check the bolts,nuts,washers,cotter pins and all terminal connections are in place and tightening and replacement of the worn out parts. (d) Check arc chutes for damage. (e) Clean and lubricate the operating mechanism with a non-hardening grease for the wearing surfaces, Adjust breaker operating mechanism all as per manufacturer’s instructional manual. (f) Checking/inspecting shunt trip coil for serviceability and replacing the same if required. (g) checking control device free for operation. (j) Check after servicing the circuit breaker to verify the contacts move to fully opened and fully closed positions, that ther is an absence of friction and that the electrical operation is functional. Note: (i)The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. (ii) Major spares like shunt release & trip coil etc will be measured & paid separately under relevant schedule items. (iii) The servicing of ACB shall be carried out by OEM/authorised vendor of OEM for proper functionning of ACBs.

18

-

-

... More
Supply only auxiliary contact block suitable for ACB of 630 A to 1250 Amps as all per existing make.

4

-

-

... More
Supply only Jaw contacts (fixed/moving) suitable for ACB of 630 A to 1250 Amps as all per existing make.

4

-

-

... More
Supply only arc chutes (for 415 V) suitable for ACB of 630 A to 1250 Amps as all per existing make.

4

-

-

... More
Supply only shunt release (415V AC) or suitable for ACB of 630 A to 1250 Amps as all per existing make.

4

-

-

... More
Supply only cradle terminal suitable for ACB of 630 A to 1250 Amps as all per existing make.

3

-

-

... More
Supply only tripping coil/closing coil suitable for ACB of 630 A to 1250 Amps as all per existing make.

4

-

-

... More
Supply only Under voltage coil suitable for ACB of 630 A to 1250 Amps as all per existing make.

5

-

-

... More
Supply only Spring charging motor suitable for ACB of 630 A to 1250 Amps as all per existing make.

5

-

-

... More
Supply only protection Release PR121/P suitable for ACB of 630 A to 1250 Amps as all per existing make.

6

-

-

... More
Supply only CT suitable for ACB of 630 A to 1250 Amps as all per existing make.

6

-

-

... More
Supply only maintenance kit suitable for ACB of 630 A to 1250 Amps as all per existing make.

6

-

-

... More
M&L for Copper bus bar chamber with fixed on insulator welded with angle iron of size 50x50x6 mm thick grounting in floor, 300 mm depth grounting with PCC (size 450x450x300 mm)1:3:6 type C-1 using 20mm graded stone aggregates upto ground level and 600 mm high above GL complete all as specified and directed of the following sizes :-

-

-

-

... More
(a) 400 Amps copper bus bar 04 Nos

2

-

-

... More
(b) 200 Amps copper bus bar 04 Nos

3

-

-

... More
(c) 100 Amps copper bus bar 04 Nos

3

-

-

... More
Supply and fixing MCCB of the following sizes on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed

-

-

-

... More
(a) MCCB 4 pole , 400 amp rating of 36 KA

2

-

-

... More
(b) MCCB 4 pole , 250 amp rating of 25 KA

3

-

-

... More
(c) MCCB 4 pole , 200 amp rating of 25 KA

4

-

-

... More
(d) MCCB 4 pole , 160 amp rating of 25 KA

4

-

-

... More
(d) MCCB 4 pole , 125 amp rating of 16 KA

5

-

-

... More
(d) MCCB 4 pole , 100 amp rating of 16 KA

5

-

-

... More
(d) MCCB 4 pole , 63 amp rating of 16 KA

5

-

-

... More
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out door , heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-

-

-

-

... More
(a) 25 to 70 Sqmm 3.5 core

6

-

-

... More
(b) 95 to 185 Sqmm 3.5 core

4

-

-

... More
(c) 240 to 400 Sqmm 3.5 core

3

-

-

... More
Servicing of APFC panel, to check the main incoming LT MCCB , and replace the unserviceable parts and ensure the performance of panel, check the fuses, capacitor serviceability and replace burnt parts with new, ensure that there is no loose connection on panel, providing proper connection including taking out cable from tenches/loop and reconnect in same after repair for as per required quantity complete all as specified and as directed. Note :- Spare parts shall be renewed and paid separately under respective items as supply only..

8

-

-

... More
Supply only HRC fuse Link of capacity 2A to 32 A

4

-

-

... More
Supply only HRC fuse Link of capacity 32 A to 63 A

4

-

-

... More
Supply Only capacitor of size 5 to 7.5 KVAR, 440 V

2

-

-

... More
Supply Only capacitor of size 10 to 15 KVAR, 440 V

2

-

-

... More
Supply Only capacitor of size 20 KVAR, 440 V

2

-

-

... More
Supply only relay of capacity 40A

3

-

-

... More
Servicing of LT panel board to check the main incoming LT MCCB , and replace the unserviceable parts and ensure the performance of panel, check the incoming and outgoing MCCBs terminals and removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter and fixing proper hanging front and rear openings replace burnt thimples with new, ensure that there is no loose connection on panel, providing cable glands including taking out cable from tenches/loop and reconnect in same after repair for as per required quantity and marking locations of out going feeder complete all as specified and as directed. Note :- Spare parts shall be renewed and paid separately under respective items as supply only.

8

-

-

... More
Supply only of multifunction meter suitable for measuring volt, Ampere, Power factor,frequency fixed in existing LT Panel based including connection etc complete all as specified and directed.

6

-

-

... More
Supply only of RYB indicator lamp LED type( set of three lamp) for incoming and outgoing supply as per Existing size complete all as specified and directed.

9

-

-

... More
Supply only of CTs of size upto 200/5 complete all as specified and directed

6

-

-

... More
Supply only of CTs of size upto 400/5 complete all as specified and directed

5

-

-

... More
Supply only of CTs of size upto 1000/5 complete all as specified and directed

4

-

-

... More
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 2.25 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25x4 mm as earthin lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.

14

-

-

... More
M&L painting of feeder pillar box complete with existing colour one coat of primer and two coat of synthetic enamel paint after preparing surfaces and including testing complete all as directed

10

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Change over panel box of overall size not less than 600mm width x 600mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having on load Changeover( Make- C&S/L&T/Schenieder) of size 400 Amp . The panel boxr shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The panel box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

1

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Change over panel box of overall size not less than 500mm width x 500mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having on load Changeover( Make- C&S/L&T/Schenieder) of size 200 Amp . The panel boxr shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The panel box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

2

-

-

... More
Supply and fixing on load change over switch front handle operationin and fixed in existing LT panel 4 pole 415 volts of capacity including taking down old unserviceable change over switch complete all as specified and as directed of the following sizes :-

-

-

-

... More
(a) 63 amps

4

-

-

... More
(b) 100 amps

3

-

-

... More
(c) 200 amps

3

-

-

... More
M & L for detecting the fault of underground LT cable by using fault locator machine including excavation required for fault confirmation and opening of cable connection from panel and re connection after fault location complete all as specified and directed. Note : The Fault locator machine shall be provided by the contractoras and when directed by engineer-in-charge.

20

-

-

... More
Supply and fixing PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor complete all as specified and directed of the following sizes:-

-

-

-

... More
(a) 2 core, 4 Sqmm

300

-

-

... More
(b) 2 core, 6 Sqmm

300

-

-

... More
(c) 2 core, 10 Sqmm

200

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1400mm width x 900mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the angle iron frame of suitable size gouted with PCC(1:2:4)) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 300 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4). The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-

1

-

-

... More
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 200 Amps-01 Nos. Make : LEGRAND /SCHNEIDER / ABB

-

-

-

... More
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-63Amps - 04 Nos Make : LEGRAND /SCHNEIDER / ABB MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Digital Multifunction meter - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE / RISHABH Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos

-

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1100mm width x 900mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the angle iron frame of suitable size gouted with PCC(1:2:4)) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4). The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-

1

-

-

... More
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 600 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 36 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 400 Amps-01 Nos. Make : LEGRAND /SCHNEIDER / ABB

-

-

-

... More
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA and thermal setting from 80% to 100% and of ratings :-200Amps - 01 Nos (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-100Amps - 03 Nos Make : LEGRAND /SCHNEIDER / ABB MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Digital Multifunction meter - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE / RISHABH Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos

-

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 1000mm width x 1000mm Height (With Canopy & Base Channel) x 500mm Depth, M.S. Channel Base Frame mounted suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 400 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

4

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 750mm width x 750mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 300 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

4

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 600mm width x 600mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 200 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

3

-

-

... More
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (With Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 100 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.

3

-

-

... More
M&L for replacement of aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs and cables all as specified and directed of the following sizes :-

-

-

-

... More
(a)16 to 35 Sq mm

50

-

-

... More
(b) 50 to 120 Sq mm

50

-

-

... More
(c) 240 to 400 Sq mm

40

-

-

... More
M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.

12

-

-

... More
S&F in repair cable route indicator made out of MS sheet of size 30cmx20cm of 4mm thick with writing HT/LT cable with MS angle iron frame and two Nos legs of 1.2 m long of size 25x25x5mm fixed in ground in PCC (1:3:6) Type C-1 using 20mm graded aggregate, size15cmx15cm x15cm including painting with 02 coats of synthetic enamel paint of specified colour over one coat of red oxide primer complete all as specified and directed.

25

-

-

... More
S&F in repairs 1.50 Mtr long house service bracket, made out of 40mm dia light grade GI pipe, bent to shape including MS hook & stay or guy and fixed to wall/ poles including all necessary nut/ bolts complete all as specified and directed.

20

-

-

... More
Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed. 'Note : (a) Replacement of major items shall be measured and paid under relevant items of this schedule. (b) Repairing upto 03 points at different electrical system without any other material will be considered as one job.

35

-

-

... More
M & L for repair of LT panel board/feeder pillar boxes including replacement of hinges/locking arrangments nut/bolts,welding, brazing etc of following sizes-

-

-

-

... More
Supply only stainless steel hinges of size not less than 6" for fixing on existing panel board

20

-

-

... More
Supply only stainless steel hinges of size not less than 4" for fixing on existing panel board

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.