Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Oct 2024
Closing Date13 Nov 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680768_1Tender No
GE/W/LKO/84 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply & fix in replacement of sheet metal enclosure indoor type Meter Box of size 1.2 x 1.5 x 0.25 mtr suitable to fix on wall/floor made out of 2mm thick CRCA sheet having independent compartments suitable for single phase energy meters (compatible with smart meter) and MCB provided with front hinged shutters with lockable arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment pre wired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 06 Nos duly crimped with copper thimbles, duly powder coated complete incl taking down old meter panel all as specified and directed by Engr-in-charge and consisting with the following :-
INCOMING:-
(a) Incoming MCCB, 4 pole, 415 volts, 50 Hz, 100 Amps, 25 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - One No.
(b) Aluminium bus bar for 3 phase 4 wire system of 4 x 200 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front openable shutter - One set.
INSTRUMENTS AND OTHER ACCESSORIES:-
(a) Indicator Lamps LED in Red/ Yellow/ Blue colour - One Set of Three.
(b) 3 Phase Multifuction meter(0-500) Volts with inbuilt selector (V, A, F) Meter type class-1.0 - One set.
(c) 6 A MCB SP for LED lamp indicator - 03 Nos. OUTGOING:-
(a) Outgoing MCB SPN, 40 Amp,10 KA C-Curve - 07 Nos Complete with internal Control wiring. (b) Meter space for Electric type digital single phase Energy Meter (compatible with smart meter) 240 V, 50 Hz, 5-30 Amp - 06 Nos
Note:- (I) Before manufacuring of eletric meter panel drawing should be passed through Engineer-in- Charge
(ii) Charges for old meter taking down carefully from old panel refixing done in new panel is included in qouated rate.
36
-
-
S&F MCCB sheet metal enclosure Frame F1 for 4 Pole, 415V, 100A, 25KA breaking capacity and suitable for Optium 2.0 (Adjustable thermal setting MCCB, Ics = 100% Icu, Adjustable Overload Setting Ir = (0.8 to 1.0)xIn ), suitable for isolation with suitable size to fix on wall/floors in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCCB complete all as specified and directed.
30
-
-
S&F in repair MCB, single pole C, 240 Volts, 06 to 32 Amps,10Ka complete all as specified and directed.
800
-
-
S&F in repair MCB, single pole & neutral C, 240 Volts, 32 to 40 Amps,10Ka complete all as specified and directed.
550
-
-
S&F in repair MCB Three Pole & Neutral C, 415 Volts, 63-100 Amps,10Ka complete all as specified and directed.
250
-
-
S&F in repair MCCB 63-100 Amps 415 volts, 4 Pole 16 KA breaking capacity complete all as specified and directed.
43
-
-
Supply & fix in replacement of sheet metal enclosure indoor type Meter Box of size 1.0 x 1.0 x 0.25 mtr suitable to fix on wall/floor made out of 2mm thick CRCA sheet having independent compartments suitable for single phase energy meters (compatible with smart meter) and MCB provided with front hinged shutters with lockable arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment pre wired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 04 Nos duly crimped with copper thimbles, duly powder coated complete incl taking down old meter panel all as specified and directed by Engr-in-charge and consisting with the following :- INCOMING:-
(a) Incoming MCCB, 4 pole, 415 volts, 50 Hz, 63 Amps, 25 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - One No.
(b) Aluminium bus bar for 3 phase 4 wire system of 4 x 150 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front openable shutter - One set.
INSTRUMENTS AND OTHER ACCESSORIES:-
(a) Indicator Lamps LED in Red/ Yellow/ Blue colour - One Set of Three.
(b) 3 Phase Multifuction meter(0-500) Volts with inbuilt selector (V, A, F) Meter type class-1.0 - One set.
(c) 6 A MCB SP for LED lamp indicator - 03 Nos. OUTGOING:-
(a) Outgoing MCB SPN, 40 Amp,10 KA C-Curve - 05 Nos Complete with internal Control wiring. (b) Meter space for Electric type digital single phase Energy Meter (compatible with smart meter) 240 V, 50 Hz, 5-30 Amp - 04 Nos
Note:- (I) Before manufacuring of eletric meter panel drawing should be passed through Engineer-in- Charge
(ii) Charges for old meter taking down carefully from old panel refixing done in new panel is included in qouated rate.
20
-
-
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
10
-
-
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
30
-
-
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar IK09, True IP 43 (with PU Gasket) with test certificate etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and directed by Engr-in-charge. ( Note: MCCB & MCB to be measured and paid seprately). Makes shall be provided group-I cat as per latest approved make given by HQ CECC
10
-
-
S&F sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate ,factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
22
-
-
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed
900
-
-
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed
5000
-
-
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 10.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 10.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed.
100
-
-
M & L in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
30
-
-
M & L in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos, 8mm dia 25mm long hex. head screw complete all as specified and directed.
40
-
-
S&F in repair Galvanised iron strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground with rectangular blocks below the strip all as directed by Engr-in-Charge
400
-
-
M&L in repair of Earthing complete with galvanized mild steel earth plate electrode 600x600x6 mm thick, burried vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized steel earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and complete all as specified and directed.
145
-
-
M&L in repair of Chemical earthing for machinery/eqpts with copper earth plate 90cmx60cmx5mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to by using copper earth strip as earth lead of size 50 x 3 mm connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
4
-
-
S&F Modular AC BOX Power unit with Socket Plug top and MCBs with Single pole and neutral enclosure with a two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed by Engr-in-charge.
Makes shall be provided group-I cat as per latest approved make given by HQ CECC
50
-
-
Supply and laying light grade GI pipe of dia 50 mm laid in trenches, wall, and floors complete all as specified and directed.
100
-
-
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 6 sqmm aluminiuam conductor complete all as specified and as directed.
500
-
-
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed.
1000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%