Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Sep 2024
Closing Date11 Oct 2024
Tender Amount₹ 44,82,000
Costs
EMD
₹ 89,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676909_1Bid Award Id
ViewTender No
9699/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Re-laying of old serviceable bricks as in cable protection cover, laid flat and dry in trenches over the cable length of brick laid perpendicular to the direction of cable complete all as specified and as directed. Note:- Old serviceable bricks obtained from item here-in-before shall be used under this item.
3
-
-
M&L for local sand cushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the substation building complete all as specified and as directed.
40.5
-
-
S & F in repair of double wall corrugated pipes as per IS 16025 Part 24 of following sizes-
-
-
-
DWC pipe (6mtr length) of 63 mm of outer dia and 50 mm inner dia.
1362
-
-
DWC pipe (6mtr length) of 120 mm of outer dia and 102.5 mm inner dia.
1110
-
-
Taking out old serviceable/unserviceable LT UG cables of size 10 to 95 Sq mm 3.5/4 Core from trenches, poles/walls/ducts and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and as directed.
2276
-
-
Taking out old serviceable/unserviceable LT/HT UG cables of size 120 to 400 Sq mm 3/3.5/4 Core from trenches, poles/walls/ducts and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and as directed.
890
-
-
Laying only and connection of serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.
-
-
-
10 sqmm to 70 Sqmm 3.5/4 core.
460
-
-
95 sqmm to 400 Sqmm 3.5/4 core.
220
-
-
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :-
-
-
-
10 Sq mm 4 core.
505
-
-
25 Sq mm 4 core.
436
-
-
50 Sq mm 3.5 core.
425
-
-
95 Sq mm 3.5 core.
450
-
-
120 Sq mm 3.5 core.
240
-
-
185 Sq mm 3.5 core.
110
-
-
240 Sq mm 3.5 core.
210
-
-
400 Sqmm 3.5 core.
110
-
-
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 100 mm bore GI tubing of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
90
-
-
M & L for servicing and testing of HT Breaker ( Outdoor ) 11 KV . 630 Amp -1000Amp including opening, checking, cleaning with CTC, cleaning wiping of insulating components, primary & secondary circuit, spouts, busbars, supports, CT, PT, check oil leakge, cleaning contact tips, cover the exposed portion of busbar with HT tape & heat shrinkable sleeves, cleaning of bushes, spout insulators for visible crack, tightness old fasteners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects including deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, including calibration and testing of relay by primary injection method complete and resetting of relay and proper alignment of mechanical system of breaker including necessary minor parts for smooth functioning complete all as specified & directed by Engr in charge. Notes :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only '
4
-
-
Supply only following spare parts for 11 KV VCB, 400/630 Amps capacity of existing make conforming to the respective cat part given as under :- (Note :(i) Fixing & testing element of following item is deemed to be included under Sch `A’ item No 1 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of qtys or non execution of any of the item)
-
-
-
Support insulator.
2
-
-
Vaccum intruppter type VL-35409 C2 or as per sample.
4
-
-
Disconnecting and taking out old Unsrviceable HT joint and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 to 120 sqmm size complete all as specified and directed.
4
-
-
Disconnecting and taking out old Unserviceable HT joint and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95/120 sqmm size complete all as specified and directed.
2
-
-
Disconnecting and taking out old Unserviceable HT joint and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrinkable type complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95/120 sqmm size complete all as specified and directed.
3
-
-
Supply and fixing MCCB thermal magnetic adjustable type 80 to 100 % of the following sizes on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed - (Note- MCCB size and model shall be fixed as per existing size of panel)
-
-
-
MCCB 4 pole , 630 amp rating of 36 KA
2
-
-
MCCB 4 pole , 400 amp rating of 36 KA
3
-
-
MCCB 4 pole , 250 amp rating of 25 KA
3
-
-
MCCB 4 pole , 200 amp rating of 25 KA
2
-
-
MCCB 4 pole , 160 amp rating of 16 KA
3
-
-
MCCB 4 pole , 125 amp rating of 16 KA
3
-
-
MCCB 4 pole , 100 amp rating of 16 KA
4
-
-
M&L for straight through jointing kit suitable for LT 1100 volts cable (earthed) for out door , heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
-
-
-
25 to 50 Sqmm 3.5 core.
5
-
-
70 to 120 Sqmm 3.5 core.
6
-
-
150 to 240 Sqmm 3.5 core.
4
-
-
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for outdoor , heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
-
-
-
25 to 70 Sqmm 3.5 core.
35
-
-
95 to 185 Sqmm 3.5 core.
25
-
-
240 to 400 Sqmm 3.5 core.
15
-
-
Supply and fixing in repair of LED road way light fitting luminaires sensor based with auto on-off ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-65, 60 watt LED with 110LM/W complete all as specified and directed.
25
-
-
Supply and fixing in repair of LED road way light fitting luminaires sensor based with auto on-off ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-66, 90 watt LED with SPD 10 KV , efficiency 110LM/W complete all as specified and directed.
35
-
-
Supply, erecting and fixing in repair true vertical position, steel tubular swaged pole (410 SP-31), 09 meter long, complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with two coats of aluminium paint over a coat of red oxide primer including painting blue(sky blue) strips of 15 cm width in alternate layers up to 1.2 mtr above the ground level complete all as specified and directed.
Note : Excavation, Earth work and PCC etc shall be measured and paid separately.
15
-
-
S&F in repair on pole factory made, dust proof, vermin proof , out door type Polycarbonate boxs not less in size 200x300x105 incl MCB SP 6 Amps,, 4 nos aluminium bus bar, insulator,GI nut, bolts and washers and aluminum lugs etc with and including FI clamp made out of 30 mmx 3 mm , nut and bolts complete all as specified and directed.
35
-
-
S&F in repair Street light bracket made out of 32 mm dia GI light grade pipe 1.2 mtr long bend to shape 120 degree and duly fixed alongwith existing pole/bldg with the help of 2 Nos of MS clamp of sizes 32x3 mm including suitable size of bolt ,nuts, and washers complete all as directed by EIC.
35
-
-
M & L for twin core aluminium conductor 2.5 sqmm PVC insulated , shethed wire complete all as specified and directed.
250
-
-
S&F rigid GI conduit 20 mm dia and duly fixed alongwith existing pole/bldg with the help of 2 Nos of MS clamp of sizes 32x3 mm including suitable size of bolt ,nuts, and washers complete all as directed by EIC.
180
-
-
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.
9
-
-
M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board etc complete all as specified and as directed.
5
-
-
M&L for cement concrete (1:3:6) type C2 using 40 mm gradded stone aggregate for Cement concrete in foundations , filling and mass concrete etc complete all as specified and as directed.
3
-
-
Surface dressing in soft/loose soil not exceeding 15 cm deep and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr and spray of herbicide chemical to stop the growth of grass and bushings complete all as specified and directed.
500
-
-
M & L for trimming/cutting/chopping of tree branches all around LT/HT over conductor upto two meter and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed. Note-(i) The deemed rate shall includes all T & P required for tree branch cutting.
50
-
-
Supply, installation, testing and commissioning in replacement of feeder pillar box, kisok outdoor type floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick outer cell and 2mm thick ineer cell, MS sheet CRCA sheet on angle iron 50x50x6 mm frame of size suitable to incorporate following accessories with front and rear opening doors, fully compartment wise , having seven tank treatment process with thickness not less than 60microns with paint shade RAL 7035 provided with suitable gasket to make it dust/vermin proof, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on pcc foundation of size as required or approved by manufacurers in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by Engr-in-charge including earth work complete comprising of following:-
1
-
-
INCOMING :-
(a) MCCB capacity 400 amp, 4 pole, 415V, 36 KA , Ics=Icu=100% Thermal magnetic adjustable type , - 1 No.
(b) Busbar chamber comprising 4 Nos made of aluminium strip of capacity 600 Amps with PVC insulated & PVC sheathed with colour coding.
(c) Multifunction digital panel meter with LCD display flush mounting type of size 96x96 mm, accuracy class 1, suitable for CTs with secondary current 5A-01 Nos.
(d) Indicator lamp LED based (RYB) - 01 Nos.
OUTGOING :-
(a) MCCB capacity 250 amp, 4 pole, 415V, 36 KAThermal magnetic adjustable type complete with spreader links - 01No.
(b) MCCB capacity 160 amp, 4 pole, 415V, 25 KA Thermal magnetic adjustable type complete with spreader links - 01 No.
(c) MCCB capacity 100 amp, 4 pole, 415V, 16 KA Thermal magnetic adjustable type complete with spreader links - 02 No.
(d) Spare - 01 No.
All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for circuitss as per standard engineering practice and required at site.
-
-
-
Supply, installation, testing and commissioning in replacement of feeder pillar box, kisok outdoor type floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick outer cell and 2mm thick ineer cell, MS sheet CRCA sheet on angle iron 50x50x6 mm frame of size suitable to incorporate following accessories with front and rear opening doors, fully compartment wise , having seven tank treatment process with thickness not less than 60microns with paint shade RAL 7035 provided with suitable gasket to make it dust/vermin proof, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on pcc foundation of size as required or approved by manufacurers in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by Engr-in-charge including earth work complete comprising of following:-
1
-
-
INCOMING :-
(a) MCCB capacity 630 amp, 4 pole, 415V, 36 KA , Ics=Icu=100% Thermal magnetic adjustable type , - 1 No.
(b) Busbar chamber comprising 4 Nos made of aluminium strip of capacity 1000 Amps with PVC insulated & PVC sheathed with colour coding.
(c) Multifunction digital panel meter with LCD display flush mounting type of size 96x96 mm, accuracy class 1, suitable for CTs with secondary current 5A-01 Nos.
(d) Indicator lamp LED based (RYB) - 01 Nos.
OUTGOING :-
(a) MCCB capacity 400 amp, 4 pole, 415V, 36 KA Thermal magnetic adjustable type complete with spreader links - 01Nos.
(b) MCCB capacity 250 amp, 4 pole, 415V, 25 KA Thermal magnetic adjustable type complete with spreader links - 02 Nos. (c) MCCB capacity 100 amp, 4 pole, 415V, 16 KA Thermal magnetic adjustable type complete with spreader links - 01 Nos.
All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for circuitss as per standard engineering practice and required at site.
-
-
-
Supply & fixing in replacement of 400 Amp aluminium busbar outdoor type floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick outer cell and 2mm thick ineer cell, MS sheet CRCA sheet on angle iron 50x50x6 mm frame of size suitable to incorporate following accessories with front and rear opening doors, having seven tank treatment process with thickness not less than 60microns with paint shade RAL 7035 provided with suitable gasket to make it dust/vermin proof, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on pcc foundation of size as required or approved by manufacurers in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by Engr-in-charge including earth work complete .
2
-
-
Supply & fixing in replacement of 200 Amp aluminium busbar outdoor type floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick outer cell and 2mm thick ineer cell, MS sheet CRCA sheet on angle iron 50x50x6 mm frame of size suitable to incorporate following accessories with front and rear opening doors, having seven tank treatment process with thickness not less than 60microns with paint shade RAL 7035 provided with suitable gasket to make it dust/vermin proof, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on pcc foundation of size as required or approved by manufacurers in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by Engr-in-charge including earth work complete .
3
-
-
S&F in replacement of MCCB four pole ,415 volt magnetic adjustable type ,400 amps with breaking capacity 25KA with thermal magnetic release on full load and over current adjustable type including suitable CRCA enclosure fixed on wall /floor on angle iron leg of size 45 mm x 45mm x 5 mm of length 500 mm including grouting and cable connection by means of suitable lugs and thimbles complete all as specified and as directed.
2
-
-
S&F in replacement of MCCB four pole ,415 volt magnetic adjustable type ,250 amps with breaking capacity 25KA with thermal magnetic release on full load and over current adjustable type including suitable CRCA enclosure fixed on wall /floor on angle iron leg of size 45 mm x 45mm x 5 mm of length 500 mm including grouting and cable connection by means of suitable lugs and thimbles complete all as specified and as directed.
3
-
-
S&F in replacement of MCCB four pole ,415 volt magnetic adjustable type ,160 amps with breaking capacity 25KA with thermal magnetic release on full load and over current adjustable type including suitable CRCA enclosure fixed on wall /floor on angle iron leg of size 45 mm x 45mm x 5 mm of length 500 mm including grouting and cable connection by means of suitable lugs and thimbles complete all as specified and as directed.
4
-
-
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 3.25 metre below normal ground level with top edge of earth plate at a depth not less than 2.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthin lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
27
-
-
S&F in replacement of off load chageover switch 250 Amp, 4 pole complete and cable connection by means of suitable lugs and thimbles complete all as specified and as directed.
5
-
-
M & L for Servicing of LT panel board to check the main incoming LT MCCB , and replace the unserviceable parts and ensure the performance of panel, check the incoming and outgoing MCCBs terminals and removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter and fixing proper hanging front and rear openings replace burnt thimples with new, ensure that there is no loose connection on panel, providing cable glands including taking out cable from tenches/loop and reconnect in same after repair for as per required quantity and marking locations of out going feeder complete all as specified and as directed. Note- (i) The cost of busbar, CTs, PTs and wiring are deemed to be included in the above quoted rate. (ii) The door hinges and their locks also included in the above quoted rate.
15
-
-
Preparation of surface of LT steel poles 9 meter long, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles and street light bracket mounted on the poles, junction box etc and making black strip upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed
350
-
-
M&L for spray painting of feeder pillar boxes/busbar boxes complete with existing colour one coat of primer and two coat of synthetic enamel paint by spray painting to achiev smooth and uniform finish incl removal of existing paint, filling up cavities and writing of MES no with black paint complete all as specified and directed
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements