Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Oct 2024
Closing Date23 Nov 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maint Of Package Type Air Conditioners At Various Locations In Tech Area At Afs Kanpur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680400_1Bid Award Id
ViewTender No
8727/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Credit Schedule and Summary of Sch A
BOQ Items
... More
S & F blower assembly for 5.5 TR Package type unit complete all as specified and directed.
10
-
-
... More
S & F in replacement of AC, single phase, 220V , 50 Hz Condensor fan motor 1/3 to 1/2 HP suitable for 5.5 TR package out door unit all as specified and directed by Engineer in Charge.
15
-
-
... More
S & F in replacement of filter dryer with flare nut suitable for Package AC as approved by Engineer in Charge.
15
-
-
... More
S & F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 22 of 11TR operated package AC unit complete all as specified and as directed.
10
-
-
... More
S & F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R-407C of 16.5TR operated package AC unit complete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of Liquid line valve, 5.5 TR of size 1/2 inch or of suitable size as per sample and testing the system leak proof before and after fixing of new valve all as directed by Engineer in Charge.
10
-
-
... More
Supply and fixing in replacement of Liquid line valve, 5.5 TR of size 5/8 inch or of suitable size as per sample and testing the system leak proof before and after fixing of new valve all as directed by Engineer in Charge.
10
-
-
... More
Supply and fixing in replacement of Liquid line valve, 5.5 TR of size 7/8 inch or of suitable size as per sample and testing the system leak proof before and after fixing of new valve all as directed by Engineer in Charge.
10
-
-
... More
S & F in replacement of power contractor MNX12 coil voltage 240 3 pole complete all as specified and directed.
10
-
-
... More
S & F in replacement of power contractor MNX32 coil voltage 240 3 pole complete all as specified and directed.
6
-
-
... More
S & F in replacement of power contractor MNX18/MNX25 coil voltage 240 3 pole complete all as specified and directed.
10
-
-
... More
Supply and fixing in replacement of PVC sheathed copper cable of size 10 Sqmm 5 core, superior quality, laying over GI slotted cable tray including necessary supports and frame work complete all as specified and directed.
80
-
-
... More
Supply and fixing in replacement of PVC insulated and PVC sheathed round heavy duty multi strained copper conductor 1100 Volt grade conforming to IS:69 and cross sectional area 4 Sqmm 3 core fixed on wall by saddles all as specified and directed by Engineer in Charge.
60
-
-
... More
Supply and fixing in replacement of PVC insulated and PVC sheathed round heavy duty multi strained copper conductor 1100 Volt grade conforming to IS:69 and cross sectional area 2.5 Sqmm 3 core fixed on wall by saddles all as directed by Engineer in Charge.
70
-
-
... More
Supply in repair control wiring with 1 sqmm single cable as per OEM of approved make all as directed by Engineer in Charge.
10
-
-
... More
S & F in replacement of pressure control HP cut out switch with air cooled Package AC upto 16.5 TR complete all as directed by Engineer in Charge.
10
-
-
... More
S & F in replacement of pressure control LP cut out switch with air cooled Package AC upto 16.5 TR complete all as directed by Engineer in Charge.
10
-
-
... More
S&F for Auxillary contractor 1NC +1NO, 2NC + 2NO all as directed by Engineer in Charge.
15
-
-
... More
Supply and fixing in replacement of MCB, 3 Pole 63 Amps , TPN and breaking capacity 10 KA complete as directed.
10
-
-
... More
Supply and fixing in replacement of MCB, 3 Pole 32 Amps , TPN and breaking capacity 10 KA complete as directed.
10
-
-
... More
Supply and fixing in replacement of MCB, 3 Pole 25 Amps , TPN and breaking capacity 10 KA complete as directed.
10
-
-
... More
S & F for new outdoor unit 5.5 TR with copper condenser coil of approved make as per OEM all as directed by Engineer in Charge.
16
-
-
... More
S & F water drain out pipe with L-bow, socket, reducer 20 mm, 25 mm, 40mm all as directed by Engineer in Charge.
60
-
-
... More
S&F in replacement of moulded case circuit breaker 63 Amps, TP , 16 KA, 415 volts 50 Hz including necessary connection for incoming /outgoing with lugs of suitable size complete all as specified and directed.
4
-
-
... More
All as per item No 27 above but of 100 Amps TP 16 KA, 415 V, 50 Hz all as directed by Engineer in Charge.
4
-
-
... More
All as per item No 27 above but of 200 Amps TP 36 KA, 415 V, 50 Hz all as directed by Engineer in Charge.
4
-
-
... More
S & F in replacement of copper pipe of size 5/8" complete all as specified and directed.
145
-
-
... More
S & F in replacement of copper pipe of size 7/8" complete all as specified and directed.
150
-
-
... More
S&F copper L-bow 5/8 all as directed by Engineer in Charge.
50
-
-
... More
S&F copper socket 5/8 all as directed by Engineer in Charge.
50
-
-
... More
S&F copper reducer 5/8x1/2 all as directed by Engineer in Charge.
25
-
-
... More
S&F copper L-bow 7/8 all as directed by Engineer in Charge.
50
-
-
... More
S&F copper socket 7/8 all as directed by Engineer in Charge.
50
-
-
... More
S&F copper reducer 7/8 x 5/8 all as directed by Engineer in Charge.
25
-
-
... More
M&L for dismantling old unserviceable compressor & supply , installation, testing & commissioning of hermetically sealed scroll type compressor 3 ph 415 V 50 Hz of capacity not less than 5.5 TR & connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connections & wiring with microprocessor control panel & sensor complete all as specified and directed. Note: (i) The cost of any other sensing/protective device Eqpt required to make the plant functional related to compressor shall be included in quotd rates. (ii) The cost of hiring of technician from the OEM of compressor for installation & commissioning shall be included in quoted rate.
15
-
-
... More
S & F in replacement of Belt b-49 suitable for package AC blower all as directed.
10
-
-
... More
S&F in replacement PLC (microprocessor controlling unit with display suitable for 11 TR (5.5 TR* 2 Compressor )) suitable for Package AC of make Blue star / Voltas having following features or any other control required to make system functional and safe. (i) Run time equalisation. (ii) Auto start after power failure. (iii) Memory back up. (iv) Built in time delay. (v) Single phasing and auto phase sequence corrector. (vi) Self fault diagnostics. (vii) Easy look up with fire alarm system.
6
-
-
... More
Supply and fixing in replacement PLC (microprocessor controlling unit with display suitable for 16 TR Compressor ) suitable for package AC of make Blue star/Voltas having following features or any other control required to make system functional and safe. (i) Run time equalisation. (ii) Auto start after power failure. (iii) Memory back up. (iv) Built in time delay. (v) Single phasing and auto phase sequence corrector. (vi) Self fault diagnostics. (vii) Easy look up with fire alarm system.
2
-
-
... More
Supply only Nitrogen gas complete all as specified and directed by engr-in-charge.
100
-
-
... More
M & L for detecting leakage from the close circuit of package type AC unit of capacity upto 16.5 TR, rectifying the leakage by breezing of copper rod & oxygen flame, vaccuming the system after rectification of leakage, charging nitrozen and holding the pressure not less than 24 hrs or as specified and directed by Engr-in-Charge.
25
-
-
... More
S & F insulation pipe of size 5/8, 7/8 complete all as specified and directed by Engr-in-charge.
100
-
-
... More
S & F insulation pipe of size 1/2, 3/8 complete all as specified and directed by Engr-in-charge.
100
-
-
... More
S & F insulation pipe 1 inch/1.5 inch complete all as specified and directed by Engr-in-charge.
50
-
-
... More
M & L for de-scaling of condenser of various Package AC plant of capecity upto 11 TR complete all as specified and as directed:- (i) Opening Block of condenser Inlet and Outlet water pipe. (ii) De-scaling of condenser tubes with de-scaling solution mixed with water by pump method for a duration of 08 hours continous circulation. (iii) Opening of bolts side condenser cover for following work. (iv) Cleaning of condenser copper tubes carefully with condenser cleaning brushes to the entire satisfaction of Engr-in-Charge. (v) Removing of rubber gasket of both side covers, preparing new rubber gasket 6 mm thick, fixing properly with existing bolts/nuts/washers. Note:- Cost of descaling solution solution is deemed to be included in quoted rates. Descaling of water cooled condenser capacity 16.5 TR by chemical solution with use of long brush in proper manner without leakage.
4
-
-
... More
M&L for Descaling of water cooled condenser capacity 16.5 TR by chemical solution with use of long brush in proper manner without leakage complete all as specified and as directed:- (i) Opening Block of condenser Inlet and Outlet water pipe.
(ii) De-scaling of condenser tubes with de-scaling solution mixed with water by pump method for a duration of 08 hours continuous circulation. (iii) Opening of bolts side condenser cover for following work. (iv) Cleaning of condenser copper tubes carefully with condenser cleaning brushes to the entire satisfaction of Engineer-in-Charge. (v) Removing of rubber gasket of both side covers, preparing new rubber gasket 6 mm thick, fixing properly with existing bolts /nuts/ washers. Note:- Cost of descaling solution is deemed to be included in quoted rates.
3
-
-
... More
M & L for cleaning of cooling tower and FRP by chemical solution complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
S&F sprinkler assembly suitable for 16.5 TR complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Taking out burnt/ defective CT fan motor of capacity 2 to 3 HP and re-winding with super eanmelded copper wire, refixing in existing package unit complete testing and commissioning all as directed. Make of copper wire as approved by GE.
1
-
-
... More
Taking out burnt/ defective condenser mono block pump motor 10 to 15 HP suitable for package unit of capacity upto 16.5 TR and re-winding with super eanmelded copper wire, refixing in existing package unit complete testing and commissioning all as directed. Make of copper wire as approved by GE.
1
-
-
... More
M & L for charging of refrigerant gas R-22 in package type AC after detection and rectification of leakage all as directed by Engineer in Charge. Note:- (i) Details of Package AC Unit in which gas is charged, such as SM/MES Number, Capecity of unit shall be entered in MB. (ii) Ref gas shall be broaught by contractor in cylinder of capacity 61 KG and empty cylinders shall be returned to the contractor only after complete consumption of gas without any extra cost to the Department.
15
-
-
... More
All as Per item No. 53 above but of refrigerant gas R-410 in cylinder Capacity of each cylinder shall be 40 Kg.
5
-
-
... More
All as Per item No. 53 above but of refrigerant gas R-407C in cylinder Capacity of each cylinder shall be 61 Kg.
5
-
-
... More
Supply, laying, testing and commissioning in replacement of MS Pipes heavy grade of size 50 mm with complete fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, etc, as required all as directed by Engineer in Charge.
18
-
-
... More
S&F in replacement of galvanised steel tubes medium grade of size 25mm including all fittings and testing complete all as directed by Engineer in Charge.
40
-
-
... More
Supply and fix Butterfly Valve of 50 mm dia, Cast Iron body Water type integrally moulded close end body construction with Hand lever operated and rating of BH-10 with thermal insulation as per requirement of chilled water line all as directed by Engineer in Charge.
5
-
-
... More
All as per item No. 58 above, but of size 100mm dia.
1
-
-
... More
S & F in replacement of Over load thermal relay 12 to 23 Amp suitable for package AC of capacity upto 16.5 TR complete all as specified and directed.
4
-
-
... More
S & F in replacement of single phase preventer VSP 2 complete all as specified and directed.
4
-
-
... More
S&F blower motor 3 to 5 HP , copper winded of approved make complete all as specified and directed.
2
-
-
... More
S & F PVC filling complete all as specified and directed.
12
-
-
... More
S & F in replacement of Evaporative blower fan blade of indoor unit suitable for package AC of capacity 11 TR all as directed by Engineer in Charge.
4
-
-
... More
S & F in replacement of propeller type Condenser fan blade suitable for outdoor unit of capacity upto 16.5 TR as per sample all as directed by Engineer in Charge..
5
-
-
... More
S & F in replacement of stainless steel fan guard grill for condenser fan suitable for out door unit of capacity upto 16.5 TR as per sample all as directed by Engineer in Charge.
5
-
-
... More
S & F in replacement of running capacitor 6 MFD , 240 Volt complete all as directed by Engineer in Charge.
10
-
-
... More
S & F in replacement of running capacitor 10 MFD, 240 Volt. all as directed by Engineer in Charge.
10
-
-
... More
S & F in replacement of Non-woven polyester media enclosed by HDPE mesh type Air filter suitable for package AC upto 16.5 TR of Blue Star/Voltas all as directed by Engineer in Charge.
5
-
-
... More
S & F in replacement of cable connection connector suitable for current capacity upto 200 Amps Blue star/Voltas package AC unit complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
S & F in replacement of Timer 5-30 seconds of approved make all as directed by Engineer in Charge.
4
-
-
... More
S & F in replacement of On/Off Push switches, ISI marked of approved make as directed by Engineer in Charge.
20
-
-
... More
S & F in replacement of RYB LED type indicator lamp , ISI marked of approved make as directed by Engineer in Charge.
20
-
-
... More
S & F in replacement of pressure guage type 1-32 size 100mm thread 3/8" surface mounting of range upto 150 PSI ISI marked of approved make as directed by Engineer in Charge.
5
-
-
... More
S & F in replacement of siphon (as per sample) in existing line, including cutting and welding of new socket / adopter complete all as specified and as directed. Note:- cost of new socket and welding work and making good to existing pipe is deemed to be included in unit rate quoted.
5
-
-
Evaluation Notes How It Works ?