Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Excavation
Eprocure
Opening Date18 Oct 2024
Closing Soon21 Nov 2024
Tender Amount₹ 8,78,14,000
Costs
EMD
₹ 7,64,070Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680185_1Tender No
CEBZ/MRT/T-06 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Notes : (i) Design of Communication System shall be done by the bidder. Cloud based server/ data storage/ communication shall not be used and only local server based system shall be designed.
(ii) The cost of each item shall also be attached to arrive at pricing in case of some addition/reduction at site.
(iii) Operating system, system software and programming shall not be interllectual property of any agency.
(iv) The memory in the hard disk shall be suitable for six months data. The backup storage device/devices shall be provided for archiving of data more than six months old.
(v) In case of addition of installations, the system shall be capable of integrating the same.
(vi) The responsibility of the agency is restricted to intimate mechanical and electrical failures such as failure of pumps, leakages etc. Such repairs shall be carried out by MES.
(vii) Operation and maintenance charges to be seperately.
(viii) The SCADA system should have provision of both manual and automatic operation of installations.
-
-
-
Note for Maintenance and operations for 10 Years :- (a) Operate SCADA system during Defect Liability Period for two years after completion of work without manning ( Contractor to provide month wise breakdown details of data / information) all as specified and as directed by Engineer-in- charge. (b) Operation and comprehensive mainenance of SCADA systems including cost of spares for 08 years post defect liability period,operation including payment of bills by telecom service provider (Contractor to provide month-wise breakdown details of data / information). all as specified and as directed by Engineer-in- charge.
-
-
-
NOTE :- COMPONENT OF PAYMENT FOR ITEM NO -1. (a) Sucessfully installation and operation of SCADA on completion of work :- 71.44 % of quoted rate of item No -1, Paymentto be regulated as per clause No 4 (a) of Particular Specification of (Water Supply SCADA) (b) 1st year under defect liability period after completion :- 1.44 % of quoted rate of item No -1.
-
-
-
(c) 2nd year under defect liability period after completion :- 1.44 % of quoted rate of item No -1. (d) 1st year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (e) 2nd year after defect liability period after completion :- 2.85 % of quoted rate of item No -1.
-
-
-
(f) 3rd year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (g) 4th year after defect liability period after completion :- 2.85 % of quoted rate of item No -1. (g) 5th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1.
-
-
-
(f) 6th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1. (g) 7th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1. (g) 8th year after defect liability period after completion :- 3.57 % of quoted rate of item No -1.
-
-
-
PART-II Supplying , installation , testing and commissioning submersible pump, electric driven 415V, TP of suitable capacity suitable for 250mm dia bore well (Casing pipe size 300mm) capacity 1200 LPM at 70 Mtr head .
6
-
-
Supplying , installation , testing and commissioning submersible pump, electric driven 415V, TP of suitable capacity suitable for 250mm dia bore well (Casing pipe size 350mm) capacity 2000 LPM at 70 Mtr head .
6
-
-
Supplying , installation , testing and commissioning submersible pump, electric driven 415V, TP of suitable capacity suitable for 250mm dia bore well (Casing pipe size 350mm) capacity 1500 LPM at 70 Mtr head.
7
-
-
Supplying , installation , testing and commissioning submersible pump, electric driven 415V, TP of suitable capacity suitable for 250mm dia bore well (Casing pipe size 350mm) capacity 2000 LPM at 70 Mtr head.
3
-
-
Supply and fixing fully automatic star delta starter of motor of capacity 30 HP, 3 phase, 415 volt complete with contractor, relay setting for protection against Undervoltage / Over Voltage, short circuit including testing.
6
-
-
Supply and fixing fully automatic star delta starter of motor of capacity 20 HP, 3 phase, 415 volt complete with contractor, relay setting for protection against Undervoltage / Over Voltage, short circuit including testing.
6
-
-
Supply and fixing fully automatic star delta starter of motor of capacity 40 HP, 3 phase, 415 volt complete with contractor, relay setting for protection against Undervoltage / Over Voltage, short circuit including testing.
7
-
-
Supply and fixing fully automatic star delta starter of motor of capacity 50 HP, 3 phase, 415 volt complete with contractor, relay setting for protection against Undervoltage / Over Voltage, short circuit including testing.
3
-
-
Taking out of old unsv sluice / NRV valve of any capacity
22
-
-
S&F Non Return Valve flanged end of class 1.6 PN 150mm (6") dia, complete as directed by Engr-in-Charge.
4
-
-
S&F Non return Valve flanged of class 1.6 PN 100mm (4") dia, complete as directed by Engr-in-Charge. Note : The rate quoted against item No- 7 & 8 shall be inclusive of jointing and jointing materials e.g rubber, mild steel nuts, bolts and washer etc complete.
7
-
-
Taking out of old Unsv column pipe of size 150 / 100mm dia bore
320
-
-
Supply and lowering in borewell, MS ERW IS-4270(2001) Column pipe 150 mm bore 4.8 mm thick in 3 mtr length both end MS flanged 10 mm thick with cut for passing the submersible cable including suitable size of nuts, bolts, washers and rubber gasket complete all as specified and directed by Engineer-in-Charge.
220
-
-
Supply and lowering in borewell, MS ERW IS-4270(2001) Column pipe 100 mm bore 4.8 mm thick in 3 mtr length both end MS flanged 10 mm thick with cut for passing the submersible cable including suitable size of nuts, bolts, washers and rubber gasket complete all as specified and directed by Engineer-in-Charge.
150
-
-
Material and labour for submersible flat copper cable 3 core 35 Sqmm multi stranded 1100 Volt grade with electric connectionincluding suitable size of copper thimble, nuts, bolts, washers complete all as specified and directed by Engineer-in-Charge.
280
-
-
Material and labour for submersible flat copper cable 3 core 16 Sqmm multi stranded 1100 Volt grade with electric connectionincluding suitable size of copper thimble, nuts, bolts, washers complete all as specified and directed by Engineer-in-Charge.
280
-
-
Supply and fixing Heavy duty chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 Kg/Cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated of FRP tank 150 Ltrs capacity.complete unit mounted on heavy duty MS fabricated frame complete with painting with anticorrosive paint connecting all item, chemical grade PVC NRV, any pipe, valve alongwith control panel of dosing pump of powder coated MS fabricated box consisting of led indicator, digital volt meter Amp meter, single phase preventor, High voltage low voltage protection. Note:-
(i) Complete unit shall be mounted heavy duty MS fabricated frame complete with painting with anticorrosive paint alongwith DOL motor starter for dosing pump, including inlet/ outlet check valve with installation.
(ii) Provide original test certificate from manufacturer with ISO 9001-2015 authorised certificates.
(iii) Foundation work and pipe line work, gate valve, starter, drilling and welding on main pipe line work etc are inclusive in the quoted rate.
22
-
-
S & F in repairs SPN DB, IP Pritection, double door, 240 Volt, 4 way with 200 amp rated bus bar complete all as specified and directed
22
-
-
S & F in repairs TPN Isolator, 415 Volt, complete all as specified and directed
22
-
-
M&L Sub main wiring with 4.0 sqmm (Nominal area) FRLS with four runs of single core PVC insulated stranded unsheathed copper conductor cable upto and including 1100 V grade drawn through in PVC conduit fixed to wall/ ceilling etc incl one runs 4.0 sqmm (nominal area) single core, FRLS PVC insulated stranded unsheathed copper conductor as earth wire and duly connected to common earth point etc. complete all as specifed and as directed.
Note: four runs of 4 sqmm single core cable, one run of 4.0 sqmm earth continuity wire and one run of PVC conduit shall be measured as one meter.
200
-
-
Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed.
924
-
-
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.
874
-
-
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed
50
-
-
Taking out old CI pipe of 100 mm dia including all fitting with spigot and socket ends and lead jointed complete all as specified and directed
1200
-
-
Taking out old CI pipe of 150 mm dia including all fitting with spigot and socket ends and lead jointed complete all as specified and directed
1000
-
-
Taking out old CI pipe of 200 mm dia including all fitting with spigot and socket ends and lead jointed complete all as specified and directed
750
-
-
Supply and laying DI pipes of size 100 mm dia with spigot and socket ends centifugally cast (spun) class K9 in any length, externally coated with metallic zink coating finished with bituminous paint complete all as specified and directed
1200
-
-
Supply and laying DI pipes of size 150 mm dia with spigot and socket ends centifugally cast (spun) class K9 in any length, externally coated with metallic zink coating finished with bituminous paint complete all as specified and directed
1000
-
-
Supply and laying DI pipes of size 200 mm dia with spigot and socket ends centifugally cast (spun) class K9 in any length, externally coated with metallic zink coating finished with bituminous paint complete all as specified and directed
750
-
-
S & F sluice valve PN-1, 150 mm dia with stainless steel spindle conforming to IS-14846-2000 doubles flange and including jointing material like suitable size of nuts, bolts, washer and rubber gasket complete all as specified and directed.
6
-
-
S & F sluice valve PN-1, 100 mm dia with stainless steel spindle conforming to IS-14846-2000 doubles flange and including jointing material like suitable size of nuts, bolts, washer and rubber gasket complete all as specified and directed.
4
-
-
S & F sluice valve PN-1, 200 mm dia with stainless steel spindle conforming to IS-14846-2000 doubles flange and including jointing material like suitable size of nuts, bolts, washer and rubber gasket complete all as specified and directed.
4
-
-
M & L DI/CI Specials class B as per IS such as bends, tappers,any type branches cross all sockets and spigot collar caps and plug up to 150mm bore all as specified and as directed
1000
-
-
M&L for construction of brick masonary valve pit of size 1.00x 1.00x 1.00mm incl necessary excavation and earth work and disposal of surplus soil upto 50m, BB work in CM 1:6, 10mm plastering internally in cement mortor 1:4, PCC 1:2:4 100mm thick at bottom and at top of wall as copling of valve pit, MS sheet 3mm thick cover double door fixed in angle iron frame 35mmX35mmX5mm and 40mmX40mmX5mm at bottom for accomadating cover duly embaded in PCC coping with 25X3mm FI lugs 300mm long, one on each side, 12mm dia MS handle made to shape, locking arrangement with 1 No.Lock with two keys NAVTAL/Godrej/Harrison 50mm incl two coats of Synthetic enamel paint over a coat of red oxide zinc chrome primer on steel surface complete all as specified and shown on drawing.
14
-
-
Note : Tenderers may note that amount of credit Rs 06,74,350.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%