Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 May 2023
Closing Date17 Jun 2023
Tender Amount₹ 49,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for REPAIR / MAINTENANCE OF SECURITY LIGHTS, ALLIED WORKS INCLUDING DAILY MAINTENANCE AT 06 MTN DIV AND REPAIR / MAINTENANCE OF SECURITY LIGHTS, EXTERNAL ELECTRIFICATION WORK AT 23 (I) RandO FLIGHT UNDER GE (WEST) BAREILLY.
BOQ for REPAIR / MAINTENANCE OF SECURITY LIGHTS, ALLIED WORKS INCLUDING DAILY MAINTENANCE AT 06 MTN DIV AND REPAIR / MAINTENANCE OF SECURITY LIGHTS, EXTERNAL ELECTRIFICATION WORK AT 23 (I) RandO FLIGHT UNDER GE (WEST) BAREILLY.
Tender documents for REPAIR / MAINTENANCE OF SECURITY LIGHTS, ALLIED WORKS INCLUDING DAILY MAINTENANCE AT 06 MTN DIV AND REPAIR / MAINTENANCE OF SECURITY LIGHTS, EXTERNAL ELECTRIFICATION WORK AT 23 (I) RandO FLIGHT UNDER GE (WEST) BAREILLY.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(b) 60 Watt capacity.

150

-

-

... More
(c) 70 / 72 Watt capacity.

160

-

-

... More
(d) 90 Watt capacity.

50

-

-

... More
S & F as in replacement light fitting Energy saving , exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 150 watt complete all as specified and directed. MAKE- Crompton, Havells, Signify Innovations India Ltd (Brand - Philips & Ecolink)

15

-

-

... More
S & F in replacement light fitting Energy saving, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 120 watt complete all as specified and directed. MAKE- Crompton, Havells, Signify Innovations India Ltd (Brand - Philips & Ecolink)

12

-

-

... More
Supply only following spare parts of LED street light fitting complete all as specified and directed: - NOTE- Fixing charges are included in the unit rate of item No. 1.00 of this schedule.

-

-

-

... More
(a) Integral LED street light driver, enclosed with glass cover frame suitable for 30 to 50 watt capacity LED light fitting.

50

-

-

... More
(b) Integral LED street light driver, enclosed with glass cover frame suitable for 60 to 72 watt capacity LED light fitting.

60

-

-

... More
(c) Integral LED street light module with complete PCB and LED suitable for 30 to 50 watt capacity LED street light fitting.

70

-

-

... More
(d) Integral LED street light module with complete PCB and LED suitable for 60 to 72 watt capacity LED street light fitting.

50

-

-

... More
S & F in replacement 2.50 Sqmm size two core PVC insulated and unsheathed multistranded aluminium conductor cable complete all as specified and directed.

1000

-

-

... More
S & F in replacement MCBs TPN 63 Ampere,415 volts, 16 KA complete all as specified and directed.

5

-

-

... More
S & F in replacement MCBs SPN 32 to 40 Ampere, 220 volts, 10 KA complete all as specified and directed.

5

-

-

... More
S & F in replacement MCBs SPN 6 to 32 Ampere, 220 volts, 10 KA complete all as specified and directed.

12

-

-

... More
S & F in replacement loop-in-loop out box of size 30 x 20 x 20 cm made out from 1.6 mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos. aluminium bus bar of size 25 mm x 2 mm duly fixed on insulator and one MCB of capacity 6 Ampere, fixed on pole with and including suitable size mild steel flat iron clamps, nut-bolts and washers etc. complete all as specified and directed.

60

-

-

... More
S & F as in replacement street light bracket made out of GI pipe light grade 32 mm dia of length upto 1.20 metre, bent to shape required with and including 2 Nos. 50 x 6 mm mild steel flat iron clamps with suitable nut-bolts, washers etc and applying one coat of aluminium paint to clamps complete all as specified and directed.

45

-

-

... More
Supply, fixing, commisioning and testing of Nature timer switch control Street Lights alongwith MCBs, Power and Panel duly pre-wired as per Model-SWADEEP-02EC 05KW1P, single phase, maximum load 5 KW complete all as specified and directed. MAKE- Swadeep, Indo Asian, Chime Electronics Delhi (Brand - Sinetrac)

3

-

-

... More
Supply, fixing, commisioning and testing of Nature timer switch control Street Lights alongwith MCBs, Power and Panel duly pre-wired as per Model-SWADEEP-02EC 12KW3P, three phase, maximum load 12 KW complete all as specified and directed. MAKE- Swadeep, Indo Asian, Chime Electronics Delhi (Brand - Sinetrac)

2

-

-

... More
S & F of 6 Sqmm twin core 1100 Volts grade heavy duty flat or circular PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connection from electric pole to Main Switch complete all as specified and directed.

600

-

-

... More
S & F of 10 Sqmm twin core 1100 Volts grade heavy duty flat or circular PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connection from electric pole to Main Switch complete all as specified and directed.

700

-

-

... More
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.

635

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.

407

-

-

... More
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.

228

-

-

... More
M & L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, punning complete all as specified and directed. NOTE- Punned thickness of 18 cm shall be considered for measurement and payment.

190.5

-

-

... More
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.

18800

-

-

... More
Supply and laying of 10 Sqmm 2 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches / ducts, fixed to wall / inside panel, drawn through pipe with and including taking out old unserviceable cable complete all as specified and directed. NOTE- Quoted unit rates shall deemed included the making connections with necessary cable glands, lugs etc. as required.

390

-

-

... More
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia with necessary nut-bolts, check nuts, washers etc., all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including ......

27

-

-

... More
...... all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 75 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.

-

-

-

... More
Dismantling of LT PCC, steel tubular pole including demolition of pole coping, foundation etc. and keeping serviceable insulators in safe custody for reuse if any complete all as specified and directed.

7

-

-

... More
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate, finial taper plug, bolt , nut and screwed type 410-SP -31 (9 meters long ) Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed. NOTE- PCC, Earth work and MS work as cross arms clamps etc. shall be measured and paid separately.

7

-

-

... More
M & L for PCC type B1 1:2:4 (using 20 mm graded aggregate) as in coping to the poles with and including necessary form work as required complete all as specified and directed.

3.5

-

-

... More
M & L for PCC 1:3:6 type C2 (using (40 mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.

10

-

-

... More
Periodical maintenance of complete runway lighting system and repair by dismantling of air field, taxi track light fitting, AFL Cable and connection of any description and segregating to servicable and unserviceable parts and make it in serviceable condition by deploying person who have knowledge about Air field light system, constant current regulator and Beacon light compelte all as specified and directed. NOTE- Replacement of spare parts will be measured and paid separately under respective items of schedule. T & P and HT insulation tape as required for repair will be arranged by the contractor at his own cost. Day of maintanence / repairs intimated by the deptt on requirement basis prior to flying twice in a month. If contractor fails to maintaining Runway light system for flying, a penalty of Rs. 2000.00 per job shall be levied on the contractor.

22

-

-

... More
S & F of bipin halogen lamp of 200 watt, 6.6 Ampere 50 Hz complete all as specified and directed.

50

-

-

... More
S & F of bipin halogen lamp of 45 watt, 6.6 Ampere 50 Hz complete all as specified and directed.

25

-

-

... More
S & F of bipin halogen holder suitable for 200 / 45 watt halogen lamp alongwith chord complete all as specified and directed.

45

-

-

... More
S & F of isolating transformer 200 Watt, 6.6 Ampere, 50 Hz complete all as specified and directed. MAKE- Bildal / AMA.

15

-

-

... More
S & F of isolating transformer 45 Watt, 6.6 Ampere, 50 Hz complete all as specified and directed. MAKE- Bildal / AMA.

15

-

-

... More
S & F of protection glass cover with washer suitable for 200 watt capacity runway light (Clear white) complete all as specified and directed.

20

-

-

... More
S & F of protection glass cover with washer suitable for 45 watt capacity taxi track light (Blue) complete all as specified and directed.

15

-

-

... More
S & F of 6 Sqmm AFL cable connector (male-female joint kit) complete all as specified and directed.

40

-

-

... More
S & F in repairs Runway light fitting 200 watt including lamp, 6.6 Ampere, outer lens, inner lens / filters, base plate rubber gasket, lamp holder, isolating transformer etc. complete all as specified and directed. MAKE- AMA ALN, Metro or equivalent as approved by GE.

12

-

-

... More
S & F in repairs Taxiway light fitting 45 watt including lamp, 6.6 Ampere, outer lens, inner lens / filters, base plate rubber gasket, lamp holder, isolating transformer etc. complete all as specified and directed. MAKE- AMA ALN, Metro or equivalent as approved by GE.

10

-

-

... More
M & L for servicing, Oiling, greasing and testing of Beacon lights including replacement of unserviceable spares as required complete all as specified and directed.

1

-

-

... More
S & F in repairs LED aviation obstruction light 12 Watt with fitting including making electric connections complete all as specified and directed. NOTE- Obstruction lights to be replaced / fixed at Hanger or ATC.

2

-

-

... More
S & F in repairs approach light fitting 200 watt including lamp, 6.6 Ampere, outer lens, inner lens / filters, base plate rubber gasket, lamp holder, isolating transformer etc. complete all as specified and directed. MAKE- AMA ALN, Metro or equivalent as approved by GE.

3

-

-

... More
Laying only old serviceable bricks obtained from taking out old cables complete all as specified and directed.

400

-

-

... More
`--- BLANK ---

-

-

-

... More
Supply and laying of 185 Sqmm 3.5 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches / ducts, fixed to wall / inside panel, drawn through pipe with and including taking out old unserviceable cable complete all as specified and directed. NOTE- Quoted unit rates shall deemed included the making connections with necessary cable glands, lugs etc. as required.

80

-

-

... More
All as per item No 43.00 here-in-before but cable size 120 Sqmm 3.5 core complete all as specified and directed.

250

-

-

... More
All as per item No 43.00 here-in-before but cable size 95 Sqmm 3.5 core complete all as specified and directed.

450

-

-

... More
All as per item No 43.00 here-in-before but cable size 25 Sqmm 4 core complete all as specified and directed.

80

-

-

... More
All as per item No 43.00 here-in-before but cable size 16 Sqmm 4 core complete all as specified and directed.

200

-

-

... More
All as per item No 43.00 here-in-before but cable size 10 Sqmm 4 core complete all as specified and directed.

150

-

-

... More
All as per item No 43.00 here-in-before but cable size 10 Sqmm 2 core complete all as specified and directed.

250

-

-

... More
S & F in repairs HT tropodome PVC insulated sheathed, AFL cable 6.6 Ampere, 5000 volts with copper conductor 6 sqmm single core multi-stranded complete all as specified and directed.

900

-

-

... More
M & L for Boring of holes under road, pavement, hardstanding or any other situation by manual means suitable for insertion of 50 to 80 mm bore pipe at a depth of not less than 1 metre below ground level for crossing the cable and making good both the ends complete all as specified and directed. NOTE- GI pipe shall be measured and paid separately under respective item of this schedule.

30

-

-

... More
S & F in repairs 50 mm bore GI pipe light grade for cable protection, fixed to pole, along wall, under floor, under road, across the drain or nallah and the like complete all as specified and directed.

20

-

-

... More
S & F in repairs 80 mm bore GI pipe light grade for cable protection, fixed to pole, along wall, under floor, under road, across the drain or nallah and the like complete all as specified and directed.

15

-

-

... More
S & F in repairs bulk head fittings for landing T with 100 Watt warm white lamp, holder with glass top cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 volt 50 Hz complete all as specified and directed.

20

-

-

... More
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 meters from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. NOTE- Tools & plants including safety measure equipments like belt, ladder, ropes etc. shall be arranged by the contractor at his own cost. Contractor or his representative will take proper shut down before starting the work and clear it before resuming power supply.

50

-

-

... More
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor, after re-stretching without kinks & bends, binding the pin / shackle insulator with appropriate size of aluminium binding wire complete all specified and directed. NOTE- Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.

1000

-

-

... More
S & F as in replacement stay assembly comprising GI stay bow 400 X 20 mm, GI steel stay rod 1800 mm long X 20 mm dia with nut-bolts, washers, GI steel plate 300 X 300 X 6 mm complete as shown in electric plate No. 1 of MES Schedule Part-I, 2009, (Specifications) with and including 7X3.15 mm size stay wire of suitable length and one No. 90 X 140 mm size loop insulator complete all as specified and directed. NOTE- Cost of stay clamp, earthwork and concrete work shall deemed included in quoted rate of this item.

5

-

-

... More
S & F as in replacement shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75 mm height and 90 mm dia for working pressure of 1100 volts LT, complete with galvanised mild steel strap 25 X 1.6 mm size, insulator bolts 12 mm dia, nuts, washers etc. complete all as specified and directed.

30

-

-

... More
S & F as in replacement pin type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm high and 65 mm dia suitable for 1100 volts grade complete all as specified and directed.

20

-

-

... More
M & L for as in replacement cross arms, bracings, supports, clamps and back plates, fabricated from structural steel sections including nut-bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed with and including applying two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed.

2

-

-

... More
M & L for cleaning and preparation of old painted surface of LT steel tubular pole and painting with one coat of aluminium paint including channels, brackets, street light brackets, cross arms and making Black, Red, Yellow and white strips as directed of 30 cm high with synthetic enamelled paint, each alternative strip upto 1.5 metre height of pole and writing pole number with yellow synthetic enamel paint after making circular base with black synthetic enamel paint and applying two coat of white wash on exposed PCC coping complete all as specified and directed.

95

-

-

... More
S & F as in replacement for providing aluminium conductor steel reinforced (ACSR) as in overhead conductor on electric poles with and including provision of aluminium binding wire 2 mm dia as required complete all as specified and directed.

2

-

-

... More
S & F in repairs MCCB 415 Volts, 4 pole, 400 Ampere, 50 Hz, 36 KA alongwith spreader terminal with adjustable thermal setting including lugs, thimbles of suitable size as required, fixed to existing panels complete all as specified and directed. MAKE-L&T, Legrand, Havells, C&S. NOTE- Necessary addition / altration as required to adjust the MCCB in the panel shall be done by the contractor and cost of the same deemed included in the unit rate of this item.

3

-

-

... More
All as per Item No 57.00 but MCCB of 250 Ampere, 25 KA, 4 pole, 415 Volts, 50 Hz complete all as specified and directed.

2

-

-

... More
All as per Item No 57.00 but MCCB of 200 Ampere, 25 KA, 4 pole, 415 Volts, 50 Hz complete all as specified and directed.

4

-

-

... More
All as per Item No 57.00 but MCCB of 125 Ampere, 16 KA, 4 pole, 415 Volts, 50 Hz complete all as specified and directed.

3

-

-

... More
All as per Item No 57.00 but MCCB of 100 Ampere, 16 KA, 4 pole, 415 Volts, 50 Hz complete all as specified and directed.

2

-

-

... More
S & F as in replacement Isolator 4 pole, 100 Ampere, 415 Volts complete all as specified and directed.

6

-

-

... More
M & L fabrication of mild steel busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6 mm fixed on porcelain insulators TPN type, out door, weather proof, vermin proof, with both way opening duly provided with neoprene rubber gasket along the doors openings, pedestal type, duly painted, powder coated CRCA steel sheet enclosere with one No. incommer MCCB 250 Ampere 36 KA and making all electric connections including thimbles as required complete all as sepcified and directed.

5

-

-

... More
NOTES- (i) Day to Day Complaints pertaining to Street Light, LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs. 500.00 per complaint per day shall be imposed from the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours daily on all working days to receive order, instructions of the work. A register shall be maintained to record all orders, instructions and their complaints and is to be signed by the contractor / his representative and the Engineer-in-charge / JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints, jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (iv) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.