Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date27 May 2023
Closing Date28 Jun 2023
Tender Amount₹ 8,00,000
Costs
EMD
₹ 16,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_598616_1Bid Award Id
ViewTender No
9065/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
40
-
-
S&F in replacement Switch flame proof switch socket & plug combined in LM6 cable termination box in LM6 250 V, 16A, 2P+earth complete all as specified and directed.
20
-
-
S&F in replacement LED light fitting 2X16 Watt flame proof, CMRI certified recommended for gas / vapour
group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
25
-
-
S&F in replacement LED light fitting 1X16 Watt flame proof, CMRI certified recommended for gas/ vapor
group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessoriesprewired and including connecting up with threecore flexible copper conductor cable with suitable size complete all as specified and directed.
40
-
-
S&F in replacement sheet metal enclosure distribution board TPN, 4 poles, double door, 4 way with 200 Amps rated bus bar vertical type with MCCB 4 pole 100 Amps 415 volt thermal megnatic base operated as incomer including concealed in surface of wall and making all connection using gland, thembles in required size including taking down old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
Note: Quoted rate shall be included cost of MCCB, cutting plastering, colouring to surface of wall to be concealed, matching with existing surface etc all as per site requirement.
1
-
-
S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
2
-
-
S&F sheet metal enclosure for MCB distribution board SPN, double door, 4 way with 200 Amp rated bus bar 230 Volts including taking down old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
2
-
-
S&F in replacement MCCB, 415 volt TPN 4 poles 63 Amps,16 kA breaking capacity, thermal based adjustable type complete all as specified and directed.
5
-
-
S&F in replacement MCB, SPN, 2 pole 220 volts, 63 Amps, 'C' curve 10 kA complete all as specified and directed.
2
-
-
S&F in replacement MCB, SPN, 2 pole 220 volts, 32- 40 Amps, 'C' curve 10 kA complete all as specified and directed.
35
-
-
S&F in replacement MCB single pole 215 volts, 06- 32 Amps, 'C' Curve 10 kA complete all as specified and directed.
50
-
-
M&L for sub main wiring with three runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 6 sqmm and drawing through in concelead rigid metallic steel conduit pipe heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 6 sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed.
Note: (i) Three run of 6 sqmm with one run of steel conduit pipe shall be measured as one unit. (ii) Cost of cutting / cheasesing / plastering / colouring, matching to disturbed surface all as existed etc as per site requirement shall be included in quoted rate.
20
-
-
M&L sub main wiring with three runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 4 sqmm and drawing through in concelead rigid metallic steel conduit pipe heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 4 sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note: (i) Three run of 6 sqmm with one run of steel conduit pipe shall be measured as one unit. (ii) Cost of cutting / cheasesing / plastering / colouring, matching to disturbed surface all as existed etc as per site requirement shall be included in quoted rate.
30
-
-
S&F in replacement flameproof cum waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
5
-
-
S&F in replacement LED polycarbonate T8 tube with in built driver and metal heat sink, efficiancy of 100 Lumens/W 4 feet long white colour including making all electric connection using three core copper cable drawn through in steel flexible counduit pipe from ceiling rose to fittings including taking out unserviceable old fittings complete all as specified and directed.
100
-
-
S&F in replacement LED Bulb 15 Watt including taking out unserviceable old complete all as specified and directed.
50
-
-
S&F in replacement Flame proof Junction box of size 220x220x110 complete all as specified and directed.
30
-
-
S&F in replacement Flame proof exhaust fan 300 mm sweep steel body heavy duty with louver mounting bracket ISI marked, energy saving less noise capacitor type including making hole in brick wall plastering colour coading and all site required work for disturbed surface matching with existing and making electric connection using three core copper cable drawn through in steel conduit pipe complete all as specified and directed.
2
-
-
S&F in replacement Flame proof wall mounting fan 24 inch sweep steel body heavy duty with energy saving less noise capacitor type including making electric connection using three core copper cable drawn through in steel conduit pipe complete all as specified and directed.
2
-
-
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
-
-
-