Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jun 2024
Closing Date17 Jul 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split type AC of 1.5 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 ,R-32, R-410 and testing the AC to the complete all as specified and directed by Engineer-in-Charge

55

-

-

... More
All as per item No. 04 but split type AC of 2.0 ton

10

-

-

... More
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22,R-32 ,R-410 and testing complete to the complete all as specified and directed by Engineer-in-Charge

9

-

-

... More
All as per item S.No 06 above but 2 TR

4

-

-

... More
M&L for Split type AC outdoor unit (suitable for existing AC) complete only of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
M&L for reinstall at any place ( with in the stn ) at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
M&L for Split AC Indoor unit (suitable for existing AC ) complete of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC complete all as specified and directed by Engineer-in-Charge

15

-

-

... More
M& L for PVC drain pipe complete all as specified and directed by Engineer-in-Charge

120

-

-

... More
M&L for providing nitril rubber thermal insulation to copper tubing’s from Indoor to outdoor units with foam pipe insulation ( 1/2" ID X 1/2" thk) followed with clamps complete all as specified and directed by Engineer-in-Charge

120

-

-

... More
M&L for repair to PCB card of window / Split type AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
M&L for repair to PCB Card of inverter type split AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
S&F in replacmemt remote control unit (cordless) as per existing model for AC unit complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F Air filter suitable for 1.5 ton split type AC as required on site incl testing for satisfactry working condition as directed by Engr-in-Charge

30

-

-

... More
All as per item No 18 but split type AC of 2.0 ton

7

-

-

... More
S & F Thermostat suitable of 1.5 ton split AC as required on site complete all as specified and directed by Engr-in-Charge

30

-

-

... More
All as per item No 20 but split type AC of 2.0 ton

8

-

-

... More
S & F Single pole contactor for Split type AC 50/60 Hz 240 V complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
S & F Axilary contactor single phase 220 Volts 10 Amps current capacity complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge

25

-

-

... More
M&L for replace copper condenser coil assembly complete suitable for 1.5 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
M&L for replace copper condenser coil assembly complete suitable for 2 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
M&L for replace copper condenser coil assembly complete suitable for window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
M&L for replace evaporator coil assembly complete suitable for 1.5 ton Split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
M&L for replace evaporator coil assembly complete suitable for 2 ton Split type AC suitable for existing incl testing for satisfactry working conditioncomplete all as specified and directed by Engineer-in-Charge

3

-

-

... More
M&L for replace evaporator coil assembly complete suitable for Window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
S&F in replacement of copper tubing 5/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
S&F in replacement of copper tubing 3/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
S&F in replacement of copper tubing 1/4” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
S&F in replacement of condensing fan motor of capacity suitable for Split AC 1.5/2 Ton testing on load for the complete all as specified and directed by Engineer-in-Charge

6

-

-

... More
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
All as per item No 35 above but capacity 36 MFD

10

-

-

... More
S&F in replacement blower suitable for existing Split AC complete all as specified and directed by Engineer-in-Charge

6

-

-

... More
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase (as per sample ) complete all as directed by Engineer-in-Charge

5

-

-

... More
S&F in repair condenser fan motor of capacity 1/20 HP, single phase (as per sample) complete all as directed by Engineer-in-Charge

5

-

-

... More
S&F in repair starting capacitor of capacity 60 MFD, 40 volt, 50 Hz complete all as directed by Engineer-in-Charge.

20

-

-

... More
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
S&F in replacement of DC fan motor of split AC unit with supper enameled copper wire of suitable gauge wire and testing on load for the enter satisfaction of Engineer-in-Charge

5

-

-

... More
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
M&L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FRLSH copper conductor cable including PVC concealed/ surface conduit of earth wire with 1 x 4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge Note:- Components reqd to be replaced will be measured and paid separately

10

-

-

... More
Supply only the following parts/components of refrigerator/Deep Freezer of 165/190/315/324/360/388/425 Ltr capacity complete all as specified and directed by Engineer-in-Charge. (a) Box type relay

3

-

-

... More
All as per item No 47 above but Thermostat with control knob

4

-

-

... More
All as per item No 47 above but Drier

2

-

-

... More
All as per item No 47 above but Condenser

3

-

-

... More
All as per item No 47 above but Copper capillary Tube

10

-

-

... More
All as per item No 47 above but Magnetic door gasket

4

-

-

... More
All as per item No 47 above but Chiller tray

2

-

-

... More
All as per item No 47 above but Vegetable tray PVC

2

-

-

... More
All as per item No 47 above but Aluminium grill rack PVC Coated)

2

-

-

... More
All as per item No 47 above but Pigmy lamp 15W with screwed/Bayonet Cap

3

-

-

... More
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of up to capacity 325 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
All as per item No 57 above but capacity of refrigerator 360 Ltr

1

-

-

... More
M&L for servicing of Deep freezer of size 320/425 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 425 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F in replacement of starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminum paint complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of brass float valves accessories 15mm size as required at site complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
M&L for Disconnecting and taking down water cooler of any make and size for repairs including detection of leakage in the system rectifying the same, dehydration & recharging of gas testing the water cooler for smooth & satisfactory working complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F in replacement of condenser fan motor single phase as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for Replacement of wiring kit for water cooler of any make and capacity complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification incl gas charging and testing complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
All as per item No 69 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
S & F in replacement Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
M & L in replacement of 01 Nos front grill and 3 side loovers suitable for disert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F in replacement of Desert cooler motor copper wound complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
S&F in replacement plug top 5 Amps complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F in replacement selector switch as required at site and complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F in replacement of rotary switch as requirement at site complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F in replacement of PVC water distributer flexible pipe with TEE and all accessories in desert cooler complete all as specified and directed as requirement at site complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
S&F in replacement of piano type 05 amp switch 230 volt , AC complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
S&F cable copper conductor PVC insulated FRLS 2 core 1.5 Sqmm complete all as specified and directed by Engineer-in-Charge.

180

-

-

... More
M&L for servicing, repair of Voltage stabilizer of capacity 4 / 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as directed by Engineer-in-Charge

15

-

-

... More
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as directed by Engineer-in-Charge

15

-

-

... More
S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as directed by Engineer-in-Charge

15

-

-

... More
S&F electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as directed by Engineer-in-Charge

15

-

-

... More
M&L in repair transformer suitable for voltage stablizer 4/5 KVA as required on site complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F in repairs and replacement of voltage stabilizer of capacity 5 KVA input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for Exhaust fan motor for 300 mm sweep ( as per suitable for exixting) complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F wall mounting fan motor for 400 mm sweep complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F in replacement of Exhaust fan 10"/12" sweep complete all as specified and directed by Engr - in- charge.

20

-

-

... More
S&F in replacement of PVC Exhaust fan 300MM sweep complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge.

75

-

-

... More
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge.

75

-

-

... More
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of any make /model complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
Supply and replacement of ball bearing of ceiling fan of any size complete all as sepecified and directed by Engr -in-Charge.

40

-

-

... More
Supply and fixing and connecting flexible copper twisted twin core of size 23/00076. complete all as specified and directed by Engineer-in-Charge.

90

-

-

... More
Supply and replacement of gun metal bush of any type/make/size complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
supply and replacement of rubber real complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply and replacement of U Clamp complete with nuts, bolts, pins Heavy duty complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply and fixing nuts,bolts, washers and spilt pins for ceiling fan complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S& F AC plug to of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S& F AC socket of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC completeall as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply, installation and testing & commissioning of LT Panel in door type made of 2 mm thick CRCA sheet, suitable angle iron frame & PCC, dust & vermin proof , front operated construction, enclosure class -IP 52, CPRI standard including copper Bus Bar of 1000 amps of suitable length, 3 Phase 50 Hz TPN 4 Nos mounted on suitable type of insulators. The metal surface shall be 2.0 mm thickness having powder coating with Seimen's grey colour complete with top /bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors in front & removable plate at the back to achieve dust and vermin proof panel with all inter connection wiring of suitable size of copper wires, ckt labels etc. Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer & outgoing ,MCCB and instrument chamber comprise of digital type ammeter & voltmeter flush mounted, selector switches, CT's, etc. The panel board shall be comprising of the following :- Incoming :- (a) MCCB 630 Amp FP 415 V with rupturing cap 50KA (adjustable type) -01 Nos Outgoing :- (a) MCCB 400 Amp FP 415 V with rupturing cap 36 KA (adjustable type) -02 Nos (b) MCCB 160 Amp FP 415 V with rupturing cap 25 KA (adjustable type) -02 Nos (c) Digital Ammeter with LED indication lamp with selector switch -1 Nos (d) Digital voltmeter with LED indication lamp with selector switch -1 Nos

1

-

-

... More
S&F in replacement of outdoor type LED flood light 200/210 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
Supply and fix as in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Supply and fix as in repair of 45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
Supply and fix as in repair of 70/75 W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply and fixing in replacement of LED post top 20 W in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
Supply and fixing in replacement of Mushroom shaped decorative LED bollard with IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement of Cylindrical shaped (FLUTE) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingPCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement of Tulip shaped LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Repair and replacement of synthetic insulating mat of thickness not less than 3.0 mm size 2.0 mtr X 1.0 mtr suitable for system voltage 33 kV and break down voltage 45 kV confirming IS 15652 : 2006 complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Repair and replacement of synthetic insulating mat of thickness not less than 3.0 mm size 2.0 mtr X 1.0 mtr suitable for system voltage 11 kV and break down voltage 45 kV confirming IS 15652 : 2006 complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Repair and replacement of synthetic insulating mat of thickness not less than 3.0 mm size 2.0 mtr X 1.0 mtr suitable for system voltage 3.3 kV and break down voltage 45 kV confirming IS 15652 : 2006 complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 320 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and directed by Engineer-in-Charge.

196

-

-

... More
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.

2

-

-

... More
Description all as per Item Ser No 127 above but using GI Strip 25x4 mm as earthing lead complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
S&F in replacement of Socket type aluminum lugs of 400 Sqmm by disconneting the cables removing the old unserviceble ones and replacing complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 240 Sqmm

20

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 120 Sqmm

30

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 95 Sqmm

40

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 70 Sqmm

40

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 50 Sqmm

40

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 35 Sqmm

50

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 25 Sqmm

60

-

-

... More
All as per item No 129 above but Socket type aluminum lugs 16 Sqmm

150

-

-

... More
Supply & fix battery compartment box made up of MS sheet 2mm thick size suitable for battery with MS cover, locking arrangements & fixing accessories with inside weather proof coated & out side Aluminium paint incl writing pole number in black colour paint etc complete all as specified & directed by Engineer-in-Charge

15

-

-

... More
S & F in replacement of Integrated all in one Solar Street light (Inbuit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 140 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service . Five star rated complete all as specified and directed by Engineer-in-Charge. Note:- OLD fan need to deposit in MES store no credit will be provided for the same.

30

-

-

... More
Supply, installation, testing and commissioning of LT panel out door type made out of 3.15 mm thick CRCA sheet, suitable angle iron frame for structure and base, copper busbar 1000 amps rated with SMC busbar supports - 04 Nos, dust/vermin proof, epoxy powder coated siemens grey painting over a coat of red oxide primer inside/outside of the panel, double shuttered with locking arrangements, cable alley, anodized aluminium with black background with white engraved letter of name plates, schematic diagram for distribution, rubber gaskets, cable glands and internal copper wirings with appropriate lugs complete including necessary civil works and making good disturbed surfaces with following accessories complete all as specified and directed by Engineer-in-Charge. (CPRI Approved) Incoming MCCB four pole, 50 KA, 400 Amps (adjustable type) - 01 No Onload change over switch 400 Amps, four pole - 01 No Outgoing MCCB four pole, 36 KA, 250 Amps (adjustable type) - 02 No MCCB four pole, 36 KA, 200 Amps (adjustable type) - 02 No MCCB four pole, 25 KA, 125 Amps (adjustable type) - 02 No MCCB four pole, 16 KA, 100 Amps (adjustable type) - 02 No Meter Digital Ammeter with LED indication lamp with selector switch -1 Nos Digital voltmeter with LED indication lamp with selector switch -1 Nos

1

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.

294

-

-

... More
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.

166

-

-

... More
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed by Engineer-In-Charge.

128

-

-

... More
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-In-Charge.

88

-

-

... More
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.

9

-

-

... More
Taking down UNSV LT Under Ground cable of any size complete all as specified and directed by Engineer-in-Charge.

1360

-

-

... More
Labour only for laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: Cable will be issued for store under Schedule "B"

150

-

-

... More
All as per Item No 148 above but for 2 core 25 Sqmm.

280

-

-

... More
All as per Item No 148 above but for 3.5 core 50 Sqmm.

250

-

-

... More
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.

200

-

-

... More
All as per item No 151 above but for 3.5 core 95 Sqmm.

300

-

-

... More
All as per item No 151 above but for 3.5 core 185 Sqmm.

180

-

-

... More
Supply & fixing or laying in replacement HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etc as reqd at site and complete all as specified and directed by Engineer-in-Charge. Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.

20

-

-

... More
Supply & fixing in replacement MCCB TPN 63 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg

4

-

-

... More
Supply & fixing in replacement MCCB TPN 100 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 125 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 160 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 200 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 250 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

1

-

-

... More
Supply & fixing in replacement MCCB TPN 400 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

1

-

-

... More
Supply & fixing in replacement MCCB TPN 630 Amps 415 Volts 50 kA complete all as specified and directed by Engineer-in-Charg

1

-

-

... More
M&L for in replacment of MCCB 800 A , breaking capacity 65 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings with extended terminals and separator links complete including doing connections with bus bar and outgoing cables , nuts bolts washers complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M / L for checking electrical /electronic circuit for finding out fauilty capacitors and replacement with Ultra heavy duty box type capacitor suitable for 440 volt 50 Hz operation of rated capacity 20 kVAr including taking down old unserviceable capacitor and and making all circuit connection and testing for smooth functioning complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
All as per item No 164 above but 10 kVAr

4

-

-

... More
All as per item No 164 above but 5 kVAr

5

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
All as item No 167 above but for cable of size 70 to 120 sq mm.

2

-

-

... More
All as item No 167 above but for cable of size 120 to 240 sq mm.

3

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 400 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for Chemical earthing , Design development supply commissioning and testing EHCC certified ground terminal earthing system hollow tube solid bar CCPRI tested for sensitive signal/Electrical equipments highly anti corrosive long life severe wear conditions in the earth pit and of standard size ISI marked copper tube out side secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal confirming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete incl PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.

2

-

-

... More
Supply and fixing in repair of Earth continuity GI wire of 4 mm dia or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
All as per item No 175 above but Copper Strip 20x3 mm

100

-

-

... More
Supply installation,testing commissioning in replacement of horizontal single mounted single phase 220 V/250 V 6000 RPM 50 Hz, AC siren audible range 2 Km 1/4 HP complete incl necessary grounting on wall/roof etc incl connections complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Surface dressing in soft/loose soil not exceeding 15 cm deep complete all as specified and directed by Engineer-in-Charge.

400

-

-

... More
M&L Broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick incl spreading lime stone powder under stones complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Repair and replacement of hydraulic crimping machine with crimping range from 10 sqmm to 400 sqmm with standard dies from 10 mm to 400 mm complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M&L for detecting of fault in LT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM complete all as specified and directed by Engineer-in-Charge. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.

4

-

-

... More
M&L for surface cleaning of LT electric panel (cubicle type ,size /capacity as per existing) installed at different location in the Stn including scrubbing /rubbing (old paint)all body surface to get all foregin particals removed off and applying two coat of spray painting with synthetic enamel paint (deco paint and existing colour )over a coat of metal primer(red oxide primer ) and disconnecting of all electrical connection like bas bar, CTs,MCCBs and all wirings,equipments and refix ( reconnection) with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
M&L for Replacement to unserviceable batteries of 12 volts 180 AH with new batteries of 12 volts 180 AH maintenance free complete all as specified and directed by Engineer-in-Charge. Make Exide/Amaron Note: Rate for initial charging are included in unit rate

2

-

-

... More
Labour only for taking out from trenches, wall, pole , Pipe, PCC, under ground, etc exsisting cable LT 1100 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable cable lenght ,unserviceable cable lenght and unuse cable lenght by meggering or any other suitable and recommended method including disconnection and re-connection of Cables. Removing unserviceable and unuse cable leght from site and keeping aside serviceable for reuse OR laying New cable supplied by dept at same location or any other location complete all as specified and directed by Engineer-in-Charge. (Earth work will be measured and paid separately under respective item).

200

-

-

... More
M&L for Dehydration including filteration and cleaning of transformer oil by centifugal dehydration machine till to achieve Di-electric strength 55 KV at 2.5 mm gap testing of sample before and after dehydration and filteration complete all as specified and directed by Engineer-in-Charge. . NOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job.

2000

-

-

... More
Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.

100

-

-

... More
Repair maintainance of oil cooled servo voltage stablizer of capacity 25 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component complete all as specified and directed by Engineer-in-Charge. Note:- The replacement spare parts shall be measured and paid separately.

1

-

-

... More
Supply Only spare part of the Voltage stablizer 20 to 25 KVA KVA as following:-

-

-

-

... More
Spring loaded finger

1

-

-

... More
Microproccessor Based eletronic control board

1

-

-

... More
Rewinding of Auto Transformer 25KVA

1

-

-

... More
Selector switch

1

-

-

... More
Voltmeter digital type

1

-

-

... More
Amperemeter digital type

1

-

-

... More
Supply, installation, testing and commissioning of LT panel out door type made out of 3.15 mm thick CRCA sheet, suitable angle iron frame for structure and base, copper busbar 1000 amps rated with SMC busbar supports - 04 Nos, dust/vermin proof, epoxy powder coated siemens grey painting over a coat of red oxide primer inside/outside of the panel, double shuttered with locking arrangements, cable alley, anodized aluminium with black background with white engraved letter of name plates, schematic diagram for distribution, rubber gaskets, cable glands and internal copper wirings with appropriate lugs complete including necessary civil works and making good disturbed surfaces with following accessories complete all as specified and directed by Engineer-in-Charge. (CPRI Approved) Incoming MCCB four pole, 50 KA, 400 Amps (adjustable type) - 01 No Onload change over switch 400 Amps, four pole - 01 No Outgoing MCCB four pole, 36 KA, 250 Amps (adjustable type) - 02 No MCCB four pole, 36 KA, 200 Amps (adjustable type) - 02 No MCCB four pole, 25 KA, 125 Amps (adjustable type) - 02 No MCCB four pole, 16 KA, 100 Amps (adjustable type) - 02 No Meter Digital Ammeter with LED indication lamp with selector switch -1 Nos Digital voltmeter with LED indication lamp with selector switch -1 Nos

1

-

-

... More
Supply, installation, commissioning and testing automatic intelligent power factor corrector (APFC) capacitor bank with MD-XL capacitor for LT 3 phase 440 volts system 50 C/S AC supply to improve PF 0.70 to 0.99 or unity automatically step wise switch capacitor panel floor mounted out door type, weather proof dust/vermin proof protection IP-54 type made out of MS sheet 14 SWG and angle iron 40mmx40mmx6mm frame factory made fabricated as modular in construction duly powder coated light grey colour painted, front openable panel shutter with locking arrangement to facilitate easy maintenance complete, natural air cooled cable entry with gland plate with provision of PCC 1:3:6 type C-I, 450mm below ground and 450mm above ground level all around legs complete of cap 200 KVAR, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
(a) Auto electric load select management system single phase integrated micro processor based electronic automatic electric load management system controller unit ECU processor for sensing reactive power demand with by pass arrangement to keep (AGLMS) in working condition including time delay functioning for spacing the switching time auto switching off facility in case of leading power factor auto/manual selector switches HRC fuse for back up protection built in natural air cooled complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
(b) APFC microprocessor base relay including isolation MCCB 100 Amps with 25 KA rupturing capacity.

-

-

-

... More
(c) Protection devices (MCB) against short circuiting over loading and isolation in the unlikely events of failure in step switching single phasing protection low/high voltage protection in balancing protection with indicating lamps current sensors (CVTs)-01 set.

-

-

-

... More
(d) Naturally air cooled MPP double dielectric heavy duty 440 volt LV 50 HZ shunt power capacitors conforming to IS-13340 and 13341 and IEC 831-I, ISI marked designed on ambient temperature 10 degree to 50 degree celcies delta connections complete with metal base enclosure copper wire connection for banking complete with watt loss not more than 0.5 watt/KVAR complete No of stepping combinations of 200 KVAR each or as directed by Engr-in-Charge.

-

-

-

... More
(e) Int. wiring with adequate size of PVC insulated copper multistranded cable with necessary lugs thimbles/glands-01 Job. Note : The APFC panel should be so designed to accommodate 10% extra space only for future expansion.

-

-

-

... More
(f) PVC insulated armoured multi-stranded 3.5 core 1100V grade cable 400 Sqmm for incoming power supply of length not less than 10 meter.

-

-

-

... More
(g) The rate quoted shall deemed to include for cable connection incl. cable glands and earth connection with GI strip 25X6mm (as per current capacity) including necessary jointing material to existing earth lead.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.