Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Feb 2023
Closing Date21 Mar 2023
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable complete all as specified and directed. (Note: Only punned thickness of sand shall be measured)

80

-

-

... More
M&L for sub class old size of Brick in trenches for cable protection of LT Cables complete all as specified and directed. (Note : Bricks must be layed across the cable all as directed )

8500

-

-

... More
M&L for boring through existing road with trench less method for passing of UG cable all as specified and directed.

18

-

-

... More
Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 2 core complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
All as per item No. 7 here-in-before but 10 Sqmm 4 core

100

-

-

... More
All as per item No. 7 here-in-before but 16 Sqmm 4 core

200

-

-

... More
All as per item No. 7 here-in-before but 25 Sqmm 4 core

200

-

-

... More
All as per item No. 7 here-in-before but 35 Sqmm 3½ core

200

-

-

... More
All as per ser item No. 7 here-in-before but 50 Sqmm 3½ core

200

-

-

... More
All as per item No. 7 here-in-before but 70 Sqmm 3½ core

200

-

-

... More
All as per item No. 7 here-in-before but 95 Sqmm 3½ core

200

-

-

... More
All as per item No. 7 here-in-before but 120 Sqmm 3½ core.

200

-

-

... More
All as per item No. 7 here-in-before but 150 Sqmm 3½ core.

150

-

-

... More
All as per item No. 7 here-in-before but 185 Sqmm 3½ core.

150

-

-

... More
All as per item No. 7 here-in-before but 240 Sqmm 3½ core.

100

-

-

... More
All as per item No. 7 here-in-before but 300 Sqmm 3½ core.

100

-

-

... More
S & F in replacement GI pipe light grade 100mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.

18

-

-

... More
All as per item No.20 here-in-before but 80mm bore.

15

-

-

... More
All as per item No.20 here-in-before but 50mm bore.

12

-

-

... More
M& L for cutting of floor/wall/road/footpath for removal of HT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.

12

-

-

... More
Taking out old defective Under Ground Cable from trenches / floor / road / wall / pipe / pole of size upto 300 sqmm 3/3.5 core complete all as directed by Engineer in Charge.

200

-

-

... More
Re-laying of serviceable HT/LT cable obtained of any size and discription all as directed by Engineer in Charge. (Excavation , earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)

200

-

-

... More
S&F LT PVC tape roll 3/4 inch size ISI marked on Panels /Transformers LT side of length25/26 mtr of best quality all as specified.

100

-

-

... More
Supply and Fix HT 11 KV Post insulators fixed on HT Busbar chambers with nut bolt washers as existing size complete all as specified and directed.

20

-

-

... More
Supply,installation,commissioning and testing in replacement of APFC panel of capacity 125 KVAR powder coated factory made outdoor type of suitable size made of Robust steel sheet construction made from min 2.10 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.(PCC, Plaster and Cement base paint shall be measured and paid seperetely). Panel comprising with following:-

1

-

-

... More
(a) Incoming MCCB 4 pole 250 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos

-

-

-

... More
(b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No.

-

-

-

... More
(c)Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three

-

-

-

... More
(d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity. Size of capacitor:- (a) 1 KVAR = 01 No. (b) 2 KVAR = 02 No. (c) 5 KVAR = 01 No. (d)10 KVAR = 02 No. (e) 20 KVAR= 01 No. (f) 25 KVAR= 03 No including indication lamp of each capacitor.

-

-

-

... More
(e)Microprocessor based 3 phase current transformer sencing relay 12 stage = 01 No( for operating of capacitor bank)

-

-

-

... More
(f)Auto/Manually switch of capacitor bank

-

-

-

... More
Supply, installation, commissioning and testing in replacement powder coated factory made panel board outdoor type CPRI approved confirming to IP 64 protaction, of suitable size made of Robust steel sheet construction made from min 2.10 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate. The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:-

1

-

-

... More
(a) Aluminium bus bar of capacity 800 Amp for phase and 400 Amps for neutral.

-

-

-

... More
(b) Incoming MCCB 4 pole 630 Amp 50 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(c) Outgoing MCCB 4 pole 400 Amp 36KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(d) Outgoing MCCB 4 pole 350 Amp 35KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(e) Outgoing MCCB 4 pole 250 Amp 35KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(f) Outgoing MCCB 4 pole 200 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(g) Outgoing MCCB 4 pole 100 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(h) On load change over switch of capacity 630 Amp – 01 Nos

-

-

-

... More
(j) Digital volt meter 0 to 500 volt with selector switch – 01 No

-

-

-

... More
(k) Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 01 No

-

-

-

... More
(l) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three

-

-

-

... More
(m) Digital timer switch (Astronomical) along with contractor/MCB and suitable accessories.

-

-

-

... More
M&L for replacement of floor mounted LT panel board outdoor type factory made and tested (CPRI approved) 415 volts 3 phase 4 wire 50 HZ AC supply having busbar chamber 800 Amps Aluminium strip TPN, installed on porcelain insulators, and copper conductor wiring , the panel shall be dust and vermin proof and made up of 3.15 mm CRCA mild steel sheet and 40x40x6 mm thick angle iron frame work , powder coated finish over one coat of red oxide primer out side and in side, front and rear opening type, with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cables, IS -694 marked of adequate size but not less than 4 sq mm and suitable to accomodate and including the following acessories:-

1

-

-

... More
(a) INCOMING :-

-

-

-

... More
(i) MCCB 4 Pole 400 Amps 50 KA -02 Nos.

-

-

-

... More
(ii)Volts meter digital type 0-500 Volts complete with salector switch -02 Nos.

-

-

-

... More
(iii) Amps meter digital type complete with CT and selector switch -02 Nos.

-

-

-

... More
(b) Change over switch 400 Amps - 01 No.

-

-

-

... More
(c) Out going ;-

-

-

-

... More
( i) MCCB 250 Amps 4 Pole 36 KA adjustable type -01 Nos.

-

-

-

... More
(ii) MCCB 200 Amps 4 Pole 36 KA adjustable type -02 Nos.

-

-

-

... More
(iii) MCCB 160 Amps 4 Pole 25 KA adjustable type -02 Nos.

-

-

-

... More
(iv) MCCB 100 Amps 4 Pole 25 KA adjustable type -01 Nos.

-

-

-

... More
(iv) Indicating lamps on each out going and incoming feeders

-

-

-

... More
Note : (i) Panel shall be mounted on brick work plate form duly plastered and PCC copping work on top surface , height shall be 0.60 m above the GL and 0.40 M all around the FPB all as per direction of Engr-in-Charge. (PCC , Plastering and finish shall be measured and paid seperetely)

-

-

-

... More
(ii) All incoming and out going cables shall be connected with suitable size of cable luggs and cable galands etc.

-

-

-

... More
M&L for PCC (1:2:4) type B2 using 40mm graded stone aggrgegate as in foundation of panels all as directed by Engineer in Charge.

1

-

-

... More
M&L for 15mm thick rendering in cement mortar (1:4) on brick work / concrete surface of plate form of panels or any description finished fair and even complete all as specified & directed by Engineer in Charge.

5

-

-

... More
M&L for preparation of plastered surface of any description and applying two coat of cement base paint complete all as specified & directed by Engineer in Charge.

5

-

-

... More
M&L for preparing old painted surface of panel board by cleaning removing of the old paint by scracthing with wire bursh/sand paper etc and including denting/patching of brocken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting over a coat of red oxide primer on inside/outside surface of panel,all as specified and directed by Engr-in- charge.

750

-

-

... More
M&L in replacement for fabrication of door/surfaces of LT panel indoor/outdoor as per existing size / thickness/shape and fitted in the panel with door handle, formed gasket around doors, lock insets, earthing strips, door stay, hinges,rivets etc. including two coat of synthetic enamel paint by spray painting over a coat of red oxide primer on inside/outside surface of panel,all as specified and directed by Engr-in- charge.

100

-

-

... More
Supply and fix in replacement copper bus bar in the panel of exsiting size and capacity for phase and neutral with heat shrinkable including PVCsleeves in different colour codes for phase indication all as per directed by Engr-in-charge.

1

-

-

... More
All as per item No 36 Above but aluminium bus bar

4

-

-

... More
S & F in replacement LED type phase indication lamp of Red /blue/Yellow colour for phase indication in existing panels complete all as specified and directed by Engr-in-charge .

30

-

-

... More
S & F in replacement selector 3 way for checking of Amps in 3 phase at different position in existing panels complete all as specified and directed by Engr-in-charge .

7

-

-

... More
All as per item No 39 Above but for checking of voltage.

7

-

-

... More
S & F in replacement MCCB , Thermal and magnetic protection type ,415 Volts, 4 pole, 630 Amps, 50 Hz, 50 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.

1

-

-

... More
S & F in replacement MCCB Thermal and magnetic protection type ,415 Volts, 4 pole, 500 Amps, 50 Hz, 36 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.

2

-

-

... More
S& F in replacement Digital volt meter 0 to 500 volt with selector switch, ISI marked of approved quality all as specified and directed by Engineer in Charge.

8

-

-

... More
S& F in replacement Digital Amp meter 0 to 800 Amp with CT of suitable ratio and selector switch ISI marked of approved quality all as specified and directed by Engineer in Charge.

10

-

-

... More
M&L Repairs & overhauling to LT ACBs of any capacity (400 A to 1000 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and rectifing them, lubrication of moving contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etc reassembling , re-installation ,testing & commissioning of ACB complete all as directed by Engineer-in- charge. Note :(i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates.

6

-

-

... More
Supply and fixing in replacement of Moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity complete all as directed by Engineer-in-charge

1

-

-

... More
Supply and fixing in replacement of fixed Arcing contact and adjust the contact pressure of LT ACB of any make any capacity complete all as directed by Engineer-in-charge

1

-

-

... More
M&L for replacement of main shaft assembly with crank & cam spacer of existing capacity LT ACB of existing make & model and testing for proper operation complete all as directed by Engineer-in-charge

1

-

-

... More
M&L for replacement of Trip coil of LT ACB of any make any capacity all as specified and directed by Engr-in-charge

1

-

-

... More
S& F in relacement of solar street light 18 W All in one type with 2 days back up of approved make complete all as specified and directed by Engr-in-charge.

3

-

-

... More
M&L for grouting of LT/APFC Panel by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate and including shifting of existing LT/APFC panel with disconeection of existing cables and reconnecting it after grouting of panel complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M & L for hardcore of broken stone or boulders gauge of 40mm to 63 mm , deposited, spread and levelled in layers n exc. 15cm thick complete all as specified and directed.

30

-

-

... More
Supply and fix in repair of LT sides brass stud with nuts, bolts and washers of exisiting transformer of 100 to 500 KVA complete all as specified and directed.

6

-

-

... More
Supply and fix in repair of HT sides brass stud with nuts, bolts and washer of exisiting transformer of 100 to 500 KVA complete all as specified and directed.

6

-

-

... More
Supply and fix ruber seal/gland on HT/LT studs of transformer complete all as specified and directed.

6

-

-

... More
Supply & fix in replacement of HT procelain transformer bushing insulator 11/.433 KV for 100 to 500 KVA transformer complete complete all as specified and directed.

3

-

-

... More
Supply & fix in replacement of LT procelain transformer bushing insulator 11/.433 KV for 100 to 500 KVA transformer complete complete all as specified and directed.

3

-

-

... More
Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out including sprinkling anti vegitation chemical for complete area with spray machine complete all as specified & directed.

1000

-

-

... More
S&F for 1100 Volts grade heavy duty cable one twin core, flat or circular 16 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed.

100

-

-

... More
S&F in replacement of 1100 Volts grade heavy duty cable one twin core, flat or circular 6 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed.

100

-

-

... More
S&F in replacement of 1100 Volts grade heavy duty cable one twin core, flat or circular 10 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed.

100

-

-

... More
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm dixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 200 Amp 25 KA complete all as sepcified and directed incl making connection /thimbles etc complete.

1

-

-

... More
All as per srl item No 62 here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB

1

-

-

... More
Preparation of old painted surface of HT Pole complete and providing one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making blue & white strips with synthetic enamelled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint complete all as specified.

50

-

-

... More
Preparation of old painted surface of LT/Street Light Pole complete and providing one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making blue & white strips with synthetic enamelled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint complete all as specified.

100

-

-

... More
S&F timer switch digital type (astronomical suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connection all as specified and directed by Engr in charge.

4

-

-

... More
M&L for earthing complete with galvanised or steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically ( to a depth not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size routed through 40mm dia light grade pipe, with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 3 of SSR -2009 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 3 of SSR(Part-I) 2009 complete all as specified and dirfected by Engineer-in-charge. Note: GI strip 32x6mm size up to 7.5 mtr shall be deemed to be included with quoted unit rate.

7

-

-

... More
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment (beyond 7.5mtr) including nuts, bolts and washers complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement of danger notice plate of 1.6mm thick, MS sheet, vitreous enamelled white, with letters, figuers and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3 mm, nuts-bolts, of approved size for LT 20 x 15 cm complete all as specified & directed by Engineer in Charge.

100

-

-

... More
M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 200 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed.

1

-

-

... More
M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 100 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed.

2

-

-

... More
M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 63 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutral complete all as specified and directed.

1

-

-

... More
Supply and fixing Isolator 4pole 63 Amps,415 Volts all as specified and directed.

2

-

-

... More
Supply and fixing Isolator 4pole 100 Amps,415 Volts all as specified and directed.

2

-

-

... More
Supply and fixing Isolator 2 pole 40 Amps,220 Volts all as specified and directed.

8

-

-

... More
Supply and fixing in replacement of HT 11 KV busbar out door type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint over a coat of red oxide primer ,pedestal type made out of mild steel sheet 3.15 mm thick,factory made using angle iron 40 mm x 40 mm x 6 mm and 500 mm high,front opening double door shutter weather proof,rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush,insulator & busbar (80x6 mm) with colour code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc including necessary earth work to fix 60 cm above ground level complete all as specified and directed by Engineer in charge.

2

-

-

... More
Supply and Fix HT insulation tapes ISI Marked for terminating high voltage cables for insulation sealing of connection of wire and cable for bus bar insulation, transformer terminal insulation etc complete all as specified and directed.

75

-

-

... More
M&L for detection of HT/LT fault by using fault locator machine highering from civil authority complete all s specified and directed by Engr-in -Charge. Note :- In one length of cable from Panel / DB / Transformer to Panel /Transformer all faults considered as single job. replacement heat shrinkable type end termination joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade complete all as specified and directed.

10

-

-

... More
M&L for replacement heat shrinkable type end termination joint suitable for cable of size 25 to 50 Sqmm, 3.5 Core, 1100 Volts grade complete all as specified and directed.

2

-

-

... More
All as per item No 79 but cable of size 70 to 150 Sqmm, 3.5 Core.

4

-

-

... More
All as per item No 79 but cable of size 185 to 240 Sqmm, 3.5 Core.

2

-

-

... More
All as per item No 79 but cable of size 300 to 400 Sqmm, 3.5 Core.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.