Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692357_1Tender No
8757/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply , fix in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps 4 pole 50KA all as specified and directed.
2
-
-
... More
Dismantling & taking down in replacement of old unservicable under votage trip device suitable for 630-4000A for LT ACB air circuit breakerscomplete all as specified and directed by EIC.
2
-
-
... More
Dismantling & taking down in replacement of old unservicable shunt trip & closing coil for 630-4000A for LT ACB complete etc all as specified and directed by EIC.
2
-
-
... More
Dismantling & taking down in replacement of old unservicable Earth fault relay suitable for 630-4000A for LT ACB air circuit breakerscomplete all as specified and directed by EIC.
2
-
-
... More
Dismantling & taking down in replacement of old unservicable Charging motor 9110 AC/DC,220V AC/DC,250V AC/DC) suitable for 630-4000A for LT ACB air circuit breakers complete all as specified and directed by EIC.
1
-
-
... More
Dismantling & taking down in replacement of old unservicable control relay for charging motor 9110 AC/DC,220V AC/DC,250V AC/DC) suitable for 630-4000A for LT ACB air circuit breaker scomplete all as specified and directed by EIC.
1
-
-
... More
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,950 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two nmber duly plasterd and PCC coping work om top surface height shall be .6. mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
2
-
-
... More
INCOMING :-(a) MCCB 4 Pole, 415 V, adjustable thermal setting ,630 Amps with breaking capacity 50 KA - 01 No OUTGOING :- (b) MCCB 4 Pole, 415 V, adjustable thermal setting 250 Amps with breaking capacity 35/36 KA - 03 No. (c) MCCB 4 Pole, 415 V, adjustable thermal setting 200 Amps with breaking capacity 25 KA - 02No. (d) MCCB 4 Pole, 415 V, adjustable thermal setting 100 Amps with breaking capacity 25 KA - 02No. (e) Voltmeter, electronic, digital type, with selector switch 0 - 500 volts, AC, 50 Hz - 1 No. (f) Ammeter electronic, digital type, 0 - 400 amps, AC, 50 Hz - 1 No. (g) Current transformer 200 / 5 amps rating, AC, 50 Hz - 3 Nos. (h) Phase indication LED lamps - 3 Nos (RYB).
-
-
-
... More
S&F in replacement of on load change over switch, 250 Amps, 4 pole,415 volts with steel sheet metal enclosure with fixing arrangement in existing wall/ panel with electrical connections complete including making good the distrubed surface to original postion complete etc all as specified and directed by EIC.
2
-
-
... More
S&F in replacement of on load change over switch, 400 Amps, 4 pole,415 volts with steel sheet metal enclosure with fixing arrangement in existing wall/ panel with electrical connections complete including making good the distrubed surface to original postion complete etc all as specified and directed by EIC.
2
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 25 to 50 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
5
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 70 to 150 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
8
-
-
... More
Supply jointing, commissioning and testing in-replacement of heat shrinkable straight through Joint suitable for cable of size 185 to 240 sqmm, 3.5 core, 1100 volts grade complete all as specified and directed by EIC.
6
-
-
... More
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,600 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two nmber duly plasterd and PCC coping work om top surface height shall be .6. mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
3
-
-
... More
INCOMING :-(a) MCCB 4 Pole, 415 V, adjustable thermal setting ,400 Amps with breaking capacity 35/36 KA - 01 No OUTGOING :- (b) MCCB 4 Pole, 415 V, adjustable thermal setting 250 Amps with breaking capacity 25 KA - 02 No. (c) MCCB 4 Pole, 415 V, adjustable thermal setting 160 Amps with breaking capacity 25 KA - 02No. (d) MCCB 4 Pole, 415 V, adjustable thermal setting 100 Amps with breaking capacity 25 KA - 02No. (e) Voltmeter, electronic, digital type, with selector switch 0 - 500 volts, AC, 50 Hz - 1 No. (f) Ammeter electronic, digital type, 0 - 400 amps, AC, 50 Hz - 1 No. (g) Current transformer 200 / 5 amps rating, AC, 50 Hz - 3 Nos. (h) Phase indication LED lamps - 3 Nos (RYB).
-
-
-
... More
Supply, fix in replacement of danger notice board 1.6mm thick M.S sheet, vitreous enamelled white with letters, figures and conventional skull and bone in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and directed.
80
-
-
... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed .
3
-
-
... More
Supplying ,fixing in repair of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat of size 6.0 sqmm for service connection complete all as specified.
90
-
-
... More
All as per item No. 19 above but cross sectional area 10 Sqmm 2 core complete all as specified and directed.
90
-
-
... More
All as per item No 19 above but cross sectional area 16 Sqmm 2 core complete all as specified and directed.
90
-
-
... More
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,400 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connectionsincluding panel shall be mounted on brick work plate from of size 250x400x600mm in two nmber duly plasterd and PCC coping work om top surface height shall be .6. mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
6
-
-
... More
INCOMING :-(a) MCCB 4 Pole, 415 V, adjustable thermal setting ,400 Amps with breaking capacity 35/36 KA - 01 No OUTGOING :- (b) MCCB 4 Pole, 415 V, adjustable thermal setting 63 Amps with breaking capacity 25 KA - 07 No. (c) MCCB 4 Pole, 415 V, adjustable thermal setting 100 Amps with breaking capacity 25 KA - 02No. (d) Voltmeter, electronic, digital type, with selector switch 0 - 500 volts, AC, 50 Hz - 1 No. (e) Ammeter electronic, digital type, 0 - 400 amps, AC, 50 Hz - 1 No. (f) Current transformer 200 / 5 amps rating, AC, 50 Hz - 3 Nos. (g) Phase indication LED lamps - 3 Nos (RYB). MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/L&T
-
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as directed by Engr-in-Charge.
121.5
-
-
... More
Returning, filling in, and including spreading, levelling, watering and well ramming in layers not exceeking 25 cm in hard and dence soil complete all as directed by Engr-in-Charge.
70
-
-
... More
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as directed by Engr-in-Charge.
70
-
-
... More
Supply and filling fine ganga sand to the full width of trench for cushioning of cable for cable protection including spreading and punning down complete all as specified and directed
36.45
-
-
... More
M&L for well burnt old size bricks, sub class B brick laid dry flat with width equal to length of whole brick, as cable protection complete all as specified and directed.
3.91
-
-
... More
M&L for Plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
1
-
-
... More
M&L for Plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all specified and directed.
1
-
-
... More
S&F in replacement of GI tubing light grade 50mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
30
-
-
... More
S&F in replacement of GI tubing light grade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
30
-
-
... More
M&L for double walled corrugated (DWC) HDPE pipe of outer dia 50mm and inner dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50sqmm cable complete all as specified and directed.
1800
-
-
... More
M&L for double walled corrugated (DWC) HDPE pipe of outer dia 90mm and inner dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90mm suitable for cable protection of size 70sqmm to 95 cable complete all as specified and directed.
1200
-
-
... More
S&F in repair FRP looping box 350x270x200mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 6 Amp, 04 Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed.Make : National/Sintex/Hensel
170
-
-
... More
S&F in replacement of MCCB, thermal magnetic protection type of 63 Amps 25KA, 4 pole, 415 volts fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc testing and commissioning complete all as specifiedand directed.
3
-
-
... More
All as per item No. 35 above but MCCB of rating 125 Amps 25KA, 4 pole, 415V
4
-
-
... More
All as per item No. 35 above but MCCB of rating 160 Amps 35/36KA, 4 pole, 415V
4
-
-
... More
All as per item No 35 above but MCCB of rating 200 Amps 35/36KA, 4 pole, 415V
4
-
-
... More
All as per item No 35 above but MCCB of rating 250 Amps 35/36KA, 4 pole, 415V
5
-
-
... More
All as per item No 35 above but MCCB of rating 350 Amps 35/36KA, 4 pole, 415V
4
-
-
... More
All as per item No 35 above but MCCB of rating 400 Amps, 35/36KA, 4 pole, 415V
6
-
-
... More
All as per item No 35 above but MCCB of rating 630 Amps 50KA, 4 pole, 415V
2
-
-
... More
Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 35 sqmm 3.5 core. laid in trench/ duct / along pole/wall etc including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete incl taking out ot old unsericeable/damaged cable complete etc all as specified directed. Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
700
-
-
... More
All as per item No.43 above but cross sectional area 16 Sqmm 4 core complete all as specified and directed.
500
-
-
... More
All as per item No.43 above but cross sectional area 25 Sqmm 3.5 core complete all as specified and directed.
500
-
-
... More
All as per item No.43 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
646
-
-
... More
All as per item No.43 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
500
-
-
... More
All as per item No. 43 above but cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
150
-
-
... More
All as per item No.43 above but cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
150
-
-
... More
All as per item No. 43 above but cross sectional area 300 Sqmm 3.5 core complete all as specified and directed.
100
-
-
... More
Supply, installation, commissioning and testing in replacement of LT feeder piller box outdoor type, IP 54 protection made out of 3.15mm thick CRCA sheet metal, double door type and sitable MS angle iron base frame, cubical type floor mounted 3 phase 4 wire, 415V properly insulated aluminium bus bar-04 Nos having capacity 375 Amps on phase and neutral, dustand vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, RYB indication lamp with Digital multifunction meter, suitable size platf built with brick work in CM (1:4) 15mm thick plastering in CM (1:6), 0.6Mtrs height from GFL, incl lugs, gland , thimble and nut bolts etc electric connection complete etc all as specified and directed by EIC . Incoming and Outgoing : (i) MCCB 250 Amps, 25KA , 4P, 415V - 01 No, (ii) RYB inidication lamp (iii) Volt meter and Ammeter.
5
-
-
... More
Supply only of LT insulation tape (25/26mtr length)3/4 inch wide ISI marked for terminating low holtage cable for insulation sealing of connection of wire and cable for busbar/panels etc complete all as specified and directed by EIC.
200
-
-
... More
M&L for clearing of bushes/small platns in and around LT panel/feerder piller box /LT/HT pole including disposal of debris to a distance not exc 50m complete all as directed
200
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%