Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Jun 2024
Closing Date20 Jul 2024
Tender Amount₹ 25,90,000
Costs
EMD
₹ 52,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_647272_2Bid Award Id
ViewTender No
8749/BKT/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S & F 35mm thick, 2nd class HW, plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile shall be as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed
5.5
-
-
S & F 35mm thick 2nd Class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
5.5
-
-
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube, fixing in opening as per specification given as per SSR Part-II section-8 complete all as per specified and directed
18
-
-
M&L for 40 mm thick flush shutters, solid core construction, with block board 3 core and plywood face panels, commercial type and laminate matt finish on both sides complete all as specified and directed.
3.5
-
-
S&F factory made solid panel PVC door shutter of 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail, on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement complete all directed.
7.5
-
-
S&F butt hinges 100mm size stainless steel complete all specified
15
-
-
S&F butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and directed.
30
-
-
S & F 200mm long stainless steel ISI marked, barrel tower bolts of extruded section and fixed complete all as specified and as directed
30
-
-
S& F stainless steel ISI marked handles fabricated type anodised 150mm size complete all as specified and directed
30
-
-
S & F 300mm long stainless steel ISI marked, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast pr extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed
10
-
-
M&L preparation of new surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint,over one coat pink primer complete all as specified and directed
35
-
-
S&F stainless steel wire cloth of size 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed
7.1
-
-
Dismantling of floor hearth and wall tiling including mortar bedding removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
35
-
-
M&L for Non Skid ceramic coloured tiles of 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed
10
-
-
M&L for glazed ceramic coloured/printed tiles (colour & shade as approved by GE) of size 300mm x 450mm x 7-8mm thick in verticle surfaces as in skirting and dado set and jointing neat cement slurry, over & including 10mm thick rendering in cement mortar (1:4) and pointed, in white cement with pigment to match the colour of tiles complete all as specified and directed
25
-
-
Taking down cement plaster on brick walls etc including racking out joints, hacking for keys in scrubbing down and washing with water etc complete all as specified and directed
60
-
-
M&L for 15mm thcik rendering on fair faces of brick work in cement mortar (1:6) finished even and smooth without using extra cement and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed
40
-
-
Supply only Integral water proofing compound as specified and directed.
5
-
-
M&L for 15mm thcik rendering on other than fair faces of brick work in cement mortar (1:4) including water proofing compound @3% by weight of cement, finished even and smooth without using extra cement applying two coats of oil bound distemper over a coat of primer on walls including preparation of new plastered surface complete all as specified and directed.
(Note : WPC shall be measured & paid separetely under relevant item of Sch 'A' given as above)
20
-
-
M&L for preparation of old plastered surfaces of wall including cornices etc by brooming down or steel wire brushing scrapping down smoke soot moulds and efflorescent salt and trading and greasy spots and applying one coat of white wash any tint complete all as specified and directed
5100
-
-
Ditto all as per item No-25 here in before but one coat of white wash on ceiling surfaces complete all as specified and directed
1800
-
-
M&L for preparation of old distempered surfaces of wall by washing rubbing down and stopping of old distempered surface of wall including cornices etc and 1mm thick of wall care putty as required for levelling and applying one coat of oil bound distemper (Oil emulsion any tint) complete all as specified and directed
6500
-
-
M&L for preparation of old painted surface of wood or wood based material of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed.
650
-
-
M&L for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
350
-
-
M&L for Complete removal or existing treatment on wall/roof projections including facia cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean free from dust loose paint etc by skilled labour complete all as specified and directed.
440
-
-
Material & Labour for Old plastered surfaces of finishing walls with paint of required shade applying Two or more coats of 100% Premium acrylic emulsion paint of having VOC less than 50 gm/litre and UV resistace as per IS 15489:2004. Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/ 10 sqm over Old surfaces complete all as specified and directed. Note: Primer and Emulsion to be carried out through air less spray machine (Mechanical Means) complete all as specified and directed.
440
-
-
M&L for anti termite treatment alongwith the external wall below concrete/Tiles or masonry apron using chemical emulsion @ 2.25 litrs per linear meter including drilling and lpugging holess etc, complete all as specified and directed.
210
-
-
M&L for anti termite treatment of soil under existing floors using chemical emulsion @ one litrs per hole, 300 mm apart including drilling and plugging holess 12mm dia holes with cement mortar (1:2) (1 cement : 2 coarse sand) to match the existing floors etc, complete all as specified and directed.
820
-
-
M&L for anti termite treatment at point of contact of wood work by using chemical emulsion (in oil or kerosene based solution) @ 0.50 litrs per hole, by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing plugging the same etc, complete all as specified and directed.
120
-
-
Cleaning of manholes of any size depth not exceeding 1.50m by taking out sludge and burrying the night soil in pits including excavation and earth work for pits complete all as specified and directed.
180
-
-
Cleaning by dewatering sludge water from septic tank/soak well through sewage suction truck/tanker of suitable capacity including removing all rubbish slushy water and disposed off out side MOD land as his own descreation of contractor complete all as specified and directed.
(Note:- The size of tanker/truck and depth of sludge in the each load and truck No shall be entered in MB for arriving unit for payment purposes complete all as specified and directed.
742
-
-
Cleaning of sewage line 100mm dia including manholes by taking out all sludge/night soil burried in a pit to out side to distance not less than 100m and covering top of pit with earth layer 25mm thickness complete all as specified and directed.
115
-
-
Ditto all as per item No-37 above but for 150mm dia sewage pipe line complete all as specified and directed.
150
-
-
Removal of blockages from Indian type, European type WC, Nahani/floor/gully traps or between manholes complete by rodding and flushing with watering to obtain smooth flow of sewage complete all as specified and directed.
160
-
-
Removal of complete existing water proofing membrane of any description on roof ( including taking down plaster/Demolition of cement concrete if any) surfaces of any description and roughening surfaces of old concrete floor by picking sweeping cleaning and washing down with water to remove dust, foreign items etc complete all as specified and directed
160
-
-
M&L for high performance hybrid plyurea slastomeric waterproofing coating cold applied of spray/brush applied liquid membrance 1.5kg/sqm with an elongation of 600% and tensile strength of 12.6 n/sqmm as per ASTM D2370,crack bridging ability of 3.5mm as per ASTM C1305,shore a hardness of min 75 as per ASTM D2240. The system includes final base preparation as per site requirement,epoxy primer application and applying for water proofing treatment in two coats at a coverage of 1kg/sqm etc including repairing and cleaning the adjoining surface complete all as specified and directed.
160
-
-
M&L including T&P for petty repairs of Security/Perimeter/road lights in way that checking lights on the poles/bldgs and making functional the lights found unserviceable by checking proper electric supply, either by submain cable,LT Cable and connection cable fault, rectifying fault if any by excavating, taking out cable upto 5 metres either side of pole and returning & filling in includiing insertation for taking any exposed joints of connection cable and new fixing of light shifting of lights by deploying skilled electrician and helper with tools etc cycle or any other fast convence from 0900 hrs to 1800 hrs on working days or in any emercengy on holidays/Sunday complete all as specified and directed.
Notes :-
(i) All safety tools shall be provided to electrician.
(ii) Electrician should be well qualified.
(iii) Ladder/ convence minimum cycles shall be provided to employed person.
(iv) NO android phone shall be permitted inside Technical area. However contractor provide normal mobile without camera phone to electrician for communication.
(v) Defective street light should be deposited in store and if any lights handed over to electrician shall be installed at site.
(vi) It complaints/checkings are not attended two consecutive days, recovery will be made @ 1000 per days.
(vii) Daily scope of work shall include minimum one techinician & one helper. It may be more in emergengy , contractor adviced to quote rate accordingly.
140
-
-
Dismantling and taking down carefully defective/non fuctional street light fittings from its existing position and refixing the same after repairing/replacement with new of unserviceable spare parts including re-assembling and testing complete all as specified and directed.
(Note : Spare parts/component of street light fitting shall be measured and paid separately under respective items as "Supply only") given here-in-after.
115
-
-
Supply only LED light driver any make suitable for LED Street light fitting of capacity 35 Watt to 45 watt complete all as specified and directed.
45
-
-
Supply only LED light driver any make suitable for LED Street light fitting of capacity 60 Watt to 90 watt complete all as specified and directed.
40
-
-
Supply only LED light driver any make suitable for LED Flood light fitting of capacity 50 watt complete all as specified and directed.
10
-
-
Supply only LED light driver any make suitable for LED Flood light fitting of capacity 120 watt complete all as specified and directed.
20
-
-
Dismantling of security street light steel tubular poles/Rail pole of any size embedded in concrete upto bottom of foundation including street light fitting complete all as specified and directed .
21
-
-
Supply, installation and fixing of 7 mtr height truly vertical GFRP/ GI street light decorative octogonal / square pole having bottom 130mm and top 70mm and base plate of size not less than 220mm x 220mm upto 12mm thickness, of any colour (as approved by GE in writing) having capacity to bear with wind speed @150 Km/hr, environmentally friendly aesthetic look. Pole shall be lab tested and have provn of profile light one side for minimum 3 mtr including IP-66 protection in multi colour decorative fancy single arm bracket of suitable size to installed LED street light upto 120 watt, including foundation base plate, nuts and bolts of suitable size etc complete all as specified and directed.
Note. Excavation and PCC will be measured & Paid separately under relevant items of Sch 'A' given here-in-after.
48
-
-
Refixing of street light fitting of upto 120 watts complete all as specified and directed.
21
-
-
S & F Street light fitting with new generation energy saving environemental friendly long life LED street light made up of pressure die cast aluminium housing with lens, energy efficient high quality consistency, glare control with toughned glass and individual high power LEDs with secondary optics ,IP66 protection and impact of capacity 60 Watt complete all as specified and directed
27
-
-
M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole foundation complete all as specified and directed.
3.89
-
-
Excavation in trenches not.exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/ dense soil for erection of pole complete all as specified and directed.
240
-
-
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any strata complete all as specified and directed.
153
-
-
Removing excavated soil to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.
155
-
-
Supply and laying sand cushioning for cable protection in trenches 8cm before laying cable and 15 cm deep over the cable complete all as specified and directed
(Note : Only turned thickness shall be measured for payment purpose)
89
-
-
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
8000
-
-
M&L for twin core PVC insulated sheathed(heavy duty) unarmoured copper cable (for phase and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings with junction box complete all as specified and directed.
380
-
-
Taking out unserviceable LT cable of any size from trenches/duct etc carefully including bricks and keeping in safe custody either for relaying or disposal complete all as specified & directed
1550
-
-
Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 16 Sq mm 4 core complete all as specified and directed.
1390
-
-
Reuse and laying only old cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 Core complete all as specified and directed.
160
-
-
Suppy, installation, commisionig and testing cubical pannel board 3 phase 4 wire 415 volt AC 50 Hz, factory made outdoor type fabricated with 3.15mm thick CRCA sheet dust and vermin proof duly powder coating painted over a coat of red oxide primer having bus bar chamber with 4 Nos 400 Amps copper bus bar on appoxy insulator 1100 volt grade, mounted on angle iron frame made out of 40mm x 40mm x 5mm angle iron 300mm high above floor level and grouting 150mm in PCC (1:2:4) type B-1 using 20mm graded stone aggregate on all four corners with and including internal connections using copper cable/wire/bus bar including photonic cell solar based sense street switch automatically on/off from 5 lux to 15 lux level with conductor with NO, NC conduct-01 Nos, 3phase 60 Amps , MCB TPN 63 AMPs etc and including following items.
INCOMING:- (a) MCCB, 200 Amps, 4 pole, 415 Volts, AC having breaking capacity , 36 KA with adjustable thermal magnetic setting – 01 No.
(b) Digital Ammeter 96x96mm 3 Phase AC 0 – 600 Amps, with built in slector switch and 3 Nos of current transformer of suitable ratio, aux supply 230 volt AC-01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos,
(d) Digital Voltmeter 96x96mm to read phase and line voltage 500 volts with built in selector switch, aux supply 230 volt AC-01 No.
OUT GOING:- (a) MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 25 KA with adjustable thermal & fixed magnetic setting, – 02 No. (b) MCCB, 63 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 25 KA with adjustable thermal & fixed magnetic setting – 01 Nos.
1
-
-
Supply, fabrication, errection, installation, testing and commissioning of cubical, outdoor type CPRI approved LT feeder piller Box totally enclosed weather and vermin proof, factory made indoor type fully compartmentalised made out of 3.15 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing portions. Protection of enclosure IP-54 complete with two coat synthetic enamel paint over one coat of red oxide primer including suitable angle flat iron frame work for supports, excavation earth work, PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation ( mini 45 cm hight from GL) , making all incoming and out going connection with suitable size copper cable including cable lugs , cable gland etc with consisting the following items.(a) 4 Nos bus bar of equal size made by copper conductor with PVC insulated coloured heat shrinkabal type sleeves , rating bus bar 300 Amps, mounted on non cracking resin type insulator - 1 Set with suitable capacity of CT,s, Ammeter , volt meter , frequincy meter, selector switch and indication lamp , LED indication lamps for ON, OFF & RYB, etc (b) MCCB ,3 phase and neutral, 415 V microprocessor release type, 4 ploes, rating 100 Amps , with rupturing capacity 16 KA - 1 No (incoming).