Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date6 Nov 2024
Closing Soon27 Nov 2024
Tender Amount₹ 38,00,000
Costs
EMD
₹ 76,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682688_1Tender No
GE(I)/KAN/T-85 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
292.32
-
-
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.
28.87
-
-
Supply and laying to wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sqmm nominal cross section 4 core in service connections complete all as specified and directed. (Note : Quoted rates shall be deemded to be including making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
814
-
-
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core complete all as specified and directed. (Note : Quoted rates shall be deemded to be including making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
780
-
-
All as per item No 7 above but 35 sqmm 3.5 core complete all as specified and directed.
782
-
-
All as per item No 7 above but cable of size 50 Sqmm 3.5 core complete all as specified and directed.
660
-
-
All as per item No 7 above but cable of size 70 Sqmm 3.5 core complete all as specified and directed.
660
-
-
All as per item No 7 above but cable of size 120 Sqmm 3.5 core complete all as specified and directed.
880
-
-
Material and labour for GI tubing light grade of size 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.
80
-
-
All as per item No 12 above but 80 mm bore complete all as specified and directed.
80
-
-
Supply & fix of cable PVC insulated flexible Copper conductor cable of size 1.5 Sqmm 3 core cut to pieces all as required for connetion with proper thimbles, drawn in existing/new GI pipe fixed to wall or pole complete all as specified and directed.
550
-
-
Supply installation, connection & commissioning of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over and including a coat of red oxide primer with 200 amps rated aluminium bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators including one MCCB 100 Amps 4 pole 415 Volt, 35 KA complete all as specified and directed.
6
-
-
Dismantling from insulators and taking down ACSR conductor of any size from HT/LT over head lines and depositing to MES store yard complete all as specified and directed.
5
-
-
Dismantling insulator of any type and any size from HT/LT over head lines and fixing other side or depositing to MES store yard complete all as specified and directed.
150
-
-
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside for reuse on the same or new location or depositing to MES store yard complete all as specified and directed.
2
-
-
Dismantling stay assembly including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site complete all as specified and directed.
1
-
-
Dismantling steel poles of any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside complete all as specified and directed.
1
-
-
Supply, installation, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including and mounted on PCC Plat form min 45 cm from ground level with PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board with the following items housed in complete all as specified and directed:-
BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with rotary handle - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.
(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set
(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 250 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 03 Nos
a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos
1
-
-
Supply, installation, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including and mounted on PCC Plat form min 45 cm from ground level with PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board with the following items housed in complete all as specified and directed:-
BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with rotary handle - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.
(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set
(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 125 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 03 Nos
a) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos
3
-
-
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable for protection cable & pipe upto 80 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
160
-
-
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanised iron strip 32x6mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil and surplus excavated material shall be disposed off from site where directed and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge including testing on completion.
8
-
-
S&F in replacement of weatherproof junction box of size 325x220x150 mm outdoor type made out of thermo polycarbonate to accmmodated 04 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts complete all as specified and directed.
50
-
-
Supply, fixing, testing and comissioning of automatic street light switch of capacity 8 KW in single phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with acessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp
(ii) MCB 63Amps (SP),10 KA, 240 volts
(iii) NATURESWITCH-01
2
-
-
Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified & directed.
50
-
-
Supply & laying DWC pipe of 38 mm internal and 50 mm outer dia for cable protection in lieu of sand and bricks complete all as specified and directed.
80
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%