Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date22 Jun 2024
Closing Date20 Jul 2024
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_661388_1Bid Award Id
ViewTender No
GE(I)/KAN/T-39 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Dismantiling of CGI/PGI sheets any thickness as in roof coverings complete all as specified and directed.
3598.2
-
-
... More
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of required size and dia complete all as specified & directed.
2915
-
-
... More
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of required size and dia complete all as specified and directed.
233.2
-
-
... More
S & F 0.63 mm thick galvanised, corrugated mild steel sheeting with zinc coating 120 gram/sqm two corrugations side lap & 150 mm end lap ,fixed with 'L' type or 'J'type or crancked hook bolt and washers orwith self drilling zinkallum coated metal screws having cap with rubber washers complete all as specified and directed.
250
-
-
... More
All as per Item No 7.00 above but except sheet complete all as specified and directed.
100
-
-
... More
S & F 1.00 mm thick PGI sheeting of class -VIII as in valley gutters, wall cladding, iron gates and straight flashings etc ,fixed with 'L' type or 'J'type or crancked hook bolt and washers or with self drilling zink coated metal screws having cap with rubber washers and sealed the joint of valley gutter with comercial bitumen 80/85 grade complete all as specified and directed.
100
-
-
... More
Taking down wooden roof truss exc 10 m but n.exc 15 m compled rafters or trussed beams span complete all as specified and directed.
5
-
-
... More
Dismantling of unframed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
2.5
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
3.5
-
-
... More
M&L MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
4181
-
-
... More
S&F in repair 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc all as specified and directed.
30
-
-
... More
S & F in repair 2mm thick solid in any colour polycarbonate sheet of profile matching with existing roof sheeting with all fitings & fixtures cub and bend if required shape and size fixed to roof at proper position etc all as specified and directed at site. Note: work will be executed up to 15 m height from ground level on roof of Hanger. Make - Bayer/ Durotuff/ Danplon.
80
-
-
... More
S & F in repair 2mm thick solid in any colour polycarbonate sheet of profile matching with existing wall cladding sheeting with all fitings & fixtures cub and bend if required shape and size fixed to wall at proper position etc all as specified and directed at site Note: work will be executed up to 15 m height from ground level on wall cladding of Hanger. Make - Bayer/ Durotuff/ Danplon.
30
-
-
... More
S&F MS wind ties for roof including securing bolts as directed, including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
349.8
-
-
... More
Demolition of unreinforcement cement concrete of any description and in position not otherwise specifically provided for complete all as specified and directed.
2.5
-
-
... More
M&L for PCC type B0 (1:2:4 using 12.5mm graded stone aggregate) as in roof kerb, benching/ padding over roof surface including chamfered on eges etc complete all as specified and directed.
1.75
-
-
... More
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, filling for fixing of hold fast etc including necessary formwork etc complete all as specified and directed.
0.75
-
-
... More
Taking down cement plaster on bricks including raking out joints hacking for key scrubbing down with water etc.complete all as specified and directed.
550
-
-
... More
M & L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, finished fair and even (upto two storey of building) complete all as specified and directed.
325
-
-
... More
M & L for 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of wall finished fair and even complete all as specified and directed.
225
-
-
... More
M&L for preparation of new plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.
324
-
-
... More
M&L for preparation of new plastered surfaces and applying three coats of white wash as on wall surfaces complete all as specified and directed.
225
-
-
... More
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide & over 10cm width or girth complete all as specified and directed.
125.43
-
-
... More
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide n.exc 10cm width or girth complete all as specified and directed.
11.66
-
-
... More
M&L for preparation of old steel surfaces width or girth exc 10 cm and applying one coat of synthetic enamel paint complete all as specified and directed.
101
-
-
... More
Demolition of plain cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level complete all as specified and directed.
19.25
-
-
... More
M & L 75 mm thick PCC (1:2:4 ) type B-1 using 20mm graded aggregate) as in flooring finished even and smooth without using of extra cement laying in alternate bay complete all as specified and directed.
100
-
-
... More
M&L 75 mm thick PCC (1:3:6) type C1(using 20 mm graded stone aggregate) as in plinth protection finished even and smooth wihtout using extra cement complete all as specified and as directed.
110
-
-
... More
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
(Note : Debris obtained from dismantling will be dispossed off as directed)
114
-
-
... More
M&L 25mm thick PCC (1:2:4) type B0, (using 12.5mm graded stone aggregate) as in floor to receive tiles complete all as specified and directed.
140
-
-
... More
M&L for non skid joint free ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the suraface over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
80
-
-
... More
All as per Item No 34.00 above but as in skirting over and including 10 mm thick rendering in CM (1:4) all as specified and as directed.
8
-
-
... More
M & L for vitrified coloured tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, polished as in floors laid over and including 15mm thick screed or screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified and directed.
60
-
-
... More
All as per Item No 36.00 above but as in skirting over and including 10 mm thick rendering in CM (1:4) all as specified and as directed.
6
-
-
... More
M&L for glazed ceramic tiles coloured, joint free in vertical surface 300X 450X 7mm thick mm thick as on walls over and incl 10mm thick rendering in cement mortar (1:4) and jointing in neet slurry and pointing in coloured cement to match the inside of tiles all complete as specified and directed.
100
-
-
... More
Taking down 100/ 110 mm dia rain water pipes, any pattern with all fittings & bends etc complete all as specified and directed.
50
-
-
... More
S&F 110mm dia , PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
50
-
-
... More
S&F PVC (SWR) bends 110 mm bore complete all as specified and directed.
18
-
-
... More
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and directed.
38
-
-
... More
S & F MS rolled sections of angle and tee or other section as in framing for cladding, glazing , ventilator and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed .
950
-
-
... More
S & F steel wire fabric not exc. 4 kg/ sqm in wood or steel members etc fixing through welded etc complete all as specified and directed.
239.4
-
-
... More
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
1.71
-
-
... More
M &L Providing precast cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate and set in cement mortar (1:4) in window or door cills, lintels (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints complete all as specified and directed.
1.71
-
-
... More
S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
205.2
-
-
... More
All as per item No. 47.00 above but 6 to 8mm dia in stirrups, spacers and binders complete all as specified and directed.
50
-
-
... More
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
13
-
-
... More
M&L MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing, conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
1300
-
-
... More
S & F in repair 0.63 mm thick galvanised, corrugated mild steel sheeting with zinc coating 120 gram/sqm with two corrugations side lap fixed with coach screws and washers on frame of MS gate etc complete all as specified and directed.
85
-
-
... More
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones all as specified and directed.
75
-
-
... More
S&F rough cast wired figured glass 5 to 6.4 mm thick and glazing with oil putty /beads square exc 0.4 but n.exc 0.75 sqm all as specified and directed.
50
-
-
... More
S&F3 mm thick sheet glass ordinary quality and glazing with putty in square n.exc 0.5 sqm min each pan all as specified and directed.
25
-
-
... More
Dismantling wall or ceiling boards (fibre, pulp insulation etc) any thickness & at any height including fittings/grids etc complete all as specified and directed.
100
-
-
... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225 : 1987, Noncombustable as per BS 476 (part 4) - 1970 and light reflectance of 85% (minimum) including and to be laid in true horizontal level suspended on interlocking metal T-Grid of not dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and complete all as specified and directed.
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements