Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Aug 2023
Closing Date25 Aug 2023
Tender Amount₹ 22,00,000
Costs
EMD
₹ 44,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_600747_3Bid Award Id
ViewTender No
8813/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(ii) Starting relay Make-Totaline/Epcos/CLASSIC/Whirlpool
30
-
-
(iii) Starting capacitor 120-150 mfd Make- Totaline / Epcos / DVM/Whirlpool
30
-
-
(iv) Starting capacitor 100-120 mfd. Make- Totaline / Epcos //DVM/Whirlpool
50
-
-
(v) Running capacitor 40-60 mfd. Make- Totaline/ Epcos/ DVM/Whirlpool
200
-
-
(vi) Running capacitor 30-36 mfd. Make- Totaline / Epcos /DVM/Whirlpool
100
-
-
(vii) Running capacitor 4-6 mfd. Make- Totaline/ Epcos/Whirlpool
80
-
-
(viii) Thermostate switch Make as per existing
5
-
-
(ix) Propeller fan suitable for window/split type AC Make- As per existing
20
-
-
(x) Cooling Coil Make- as per existing
1
-
-
(xi) Condensor coil Make- as per existing
1
-
-
(xiii) Outer cover duly painted for Window/split AC
1
-
-
(xii) MCB SP 20-32 Amps ‘C’ Series ,10KA, 240 volts SP Make : Havells/HPL/Legrand
50
-
-
(xiii) Three pin metalic socket outlet suitable for sheet metal enclosure Make : Havells/HPL/Legrand
100
-
-
(xiv) Three pin metallic plug top suitable for sheet metal enclsoure Make : Havells/HPL/Legrand
100
-
-
(xv) PVC flexible insulated cable multi-strand copper conductor 3/4 core of size 2.5 sq mm Make- Kalinga / Plaza / Gloster/Polycab
200
-
-
(xvi) Front grill for split/window AC Make as per existing
1
-
-
(xix) Wiring kit with thimbles
2
-
-
(xx) Power Contactors 240 volts AC 50HZ 16-25 Amps range.
50
-
-
(xxi) Power contactor 415V AC, 50 Hz 20-32 Amps range
5
-
-
(xxii) Isolator 4 pole 63 Amps 415 Volt
2
-
-
(xxiii) Overload protector suitable for compressor as per existing.
5
-
-
(xxiv) Blower for indoor unit/window AC as per existing.
10
-
-
S & F Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclsoure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of repturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete Make- Legrand / Havells / schnider
20
-
-
Removing the burnt/defective sealed compressor unit any type of any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as directed. Note:- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only.
5
-
-
All as per Sr item No. 4 above but for air conditioner split type 1.5 ton capacity.
10
-
-
All as per Sr item No. 4 above but for air conditioner split type 2.0 ton capacity.
15
-
-
All as per Sr item No. 4 above but for air conditioner split type 3.0 /4.0 ton capacity.
1
-
-
M&L for replacement of damaged copper tubing of dia 5/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
50
-
-
M&L for replacement of damaged copper tubing of dia 3/8 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
50
-
-
M&L for replacement of damaged copper tubing of dia 1/2 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
50
-
-
M&L for replacement of damaged copper tubing of dia 1/4 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
50
-
-
M&L for replacement of damaged insulation with heavy duty foam for copper tubing of split air conditioners complete all as directed
100
-
-
S&F in replacement of PVC drain pipes of size 15 mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge.
100
-
-
Supply and fixing of medium class insulated Hard PVC Drain Water pipe of 20 mm dia with all fittings ie elbow,tee,bend etc all as specified and directed.
50
-
-
Repair to Air conditioner Window/Split type upto 2.0 ton to capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R134a/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.(b) Contractor should be responsible if leakage of refrigerent gas after repair on completing job and done same job without extra payment.
230
-
-
Repair to Air conditioner Split type 3.0 ton to 4.0 ton capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas (M410a/R32/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.
20
-
-
Supply and replacement blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.;
5
-
-
Supply and replacement blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton/3.0 ton/4.0 ton as per existing model complete as directed and specified.
15
-
-
Repair and fixing blower Motor of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
20
-
-
Supply and replacement Condensor Motor (outdoor motor) for split type Air conditioner as per existing model and any capacity complete as directed and specified.
20
-
-
Repair and fixing Condensor Motor (outdoor motor) for split type Air conditioner as per existing model of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
25
-
-
Repair and fixing Printed Circuit Board of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
40
-
-
Supply and replacement Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed Make- Voltas/Carrier/toshiba.
30
-
-
Supply and replacement Inverter Type Printed Circuit Board(for indoor and outdoor unit complete) of any make and type of air conditioner split inverter type of any make and type (variable speed compressor) as per existing model and capacity up to 2.0 ton complete all as specified and directed.
Make:Carrier (X power gold)/Electrolux/LG/HITACHI
10
-
-
Repair and fixing Inverter Type Printed Circuit Board of split type Air Conditioners (with variable speed compressor) of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
10
-
-
Supply and replacement for wireless remote control unit for split/window type airconditioner as per existing model complete all as directed. Make Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS
20
-
-
M&L for opening of the automatic voltage stabilizer capacity up to 8 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified . Note : (a) Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only and minor spare are including in quoted rate.
75
-
-
Supply only the spare parts suitable for automatic voltage stabilizer of any make and capacity.
-
-
-
(a) Volt meter (0-300 volts)
30
-
-
(b) Control relay
45
-
-
(c) IC controlled circuit for 5KVA
30
-
-
(d) IC controlled circuit for 8 KVA
2
-
-
(e) Control transformer
30
-
-
(f) Low/high voltage cut off and TDR system
35
-
-
(g) Main transformer for 5 KVA
10
-
-
(h) Main transformer for 8 KVA
1
-
-
Supply Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA note:Old stablizer shall be deposited in the MES store yard for board.
6
-
-
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
20
-
-
M&L for Shifting and refixing of window AC of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of window AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas and LDPE pipe are inclusive in quoted rate.(c) Making hole on wall and good the disturbed surface with existing colour matching are inclusive in quoted rate.
6
-
-
M&L for attending day to day complaints and rectifying faults like decarbonizing connections in the AC Box, , any burning due to over loading in AC and restoring connection of AC with wire or thimbles,attending and rectifying faults related to AC like drain water leakage ,filter cleanig,remote setting etc and related to stabilizers (5 to 8 KVA) incl Sunday & Holidays complete all as directed by Engineer-in-Cgarge. Note : (i) All T&P required shall be provided by contractor including ladders of any size as per requirement at site. (iii) Minor items like machine screw, plastic clamps, insulation tape, nails, flexible pipe, thimbles, lugs for contactor, etc shall deemed to be included in the unit rate. (iv) The major items replaced during repairs shall be measured and paid under respective items of Sch 'A'.
350
-
-
M&L for removing defective window AC and replacing the same for window AC of capacity upto 2.0 ton .
1
-
-
M&L for removing defective outdoor unit and replacing the same for split air conditioner of capacity 1.5/2 Ton with remote complete all as specified and directed.
1
-
-
M&L for removing defective indoor unit and replacing the same for split air conditioner of capacity 1.5/2 Ton with remote complete all as specified and directed.
1
-
-
M&L for outdoor unit stand for wall mounting type or floor mounted complete factory made as recommended for make Airconditioner and approved by Engr-in-charge.
5
-
-
S&F in replacement of sheet metal encl single pole and neutral, earth flood and socket capacity 20 Amp incl one MCB SP 20 Amp 10 KA curve C series complete all as specified and directed.
6
-
-
Removing the burnt/defective sealed compressor unit any make from Air Conditioner split type up to 5.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding / brazing work and tightening foundation nuts & bolts including etc complete all as specified and directed. Note : (a) Capillary, drier, copper tubing etc are inclusive in unit rate.
(b) New compressors will be purchase from authorized dealer only
1
-
-
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements