Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date4 Jun 2024
Closing Date5 Sep 2024
Tender Amount₹ 8,08,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE A PART II-B (Internal Water Supply)

-

-

-

... More
S&F in Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15mm bore complete all as specified and directed .

1

-

-

... More
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder

1

-

32521.78

... More
SCHEDULE A PART III-B (Internal Electrification)

-

-

-

... More
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - Notes [i] Wiring from the DB (distribution box) to switch shall be deemed inclusive in the quoted rates. [ii] Sunken modular flush sheet metal enclosures shall be deemed inclusive in the quoted rates. [iii] Modular cover plates shall be deemed inclusive in the quoted rates. (iv) Refer drawing for location of switch board , light fitting and other accessories.

-

-

-

... More
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.

24

-

-

... More
(b) One three pin 5 Amp socket on same board with other switches.

1

-

-

... More
(c) One three pin 5 Amp socket on independent board

4

-

-

... More
All as per item No- 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm.

1

-

-

... More
Supply & fix LED lamp bulb 9 watt (cool day light) having colour temp 6500 K and lumen output 850 suitable for "B-22" type to fix on batten holder complete all as specified and directed.

9

-

-

... More
M&L for ceiling rose 3 terminal /PVC/ polycarbonate, isolated body all as specified and directed.

13

-

-

... More
Supply & fix LED tube light batten 20 watts 4 fts extruded polycarbonate housing, transculant diffuser with LED light source, 2000 lumen, natural white , surge protection range - 2KV, voltage protection range 120-280 VAC with intergrated driver and surge protection complete all as specified and directed.

7

-

-

... More
Supply & fix LED tube 25 watt building security light fitting mounting type made out of one piece in pressure die-cast aluminium housing with high efficient LED as lighting source and PC cover seperate compartment for driver including bracket clamp and fixing accessories complete with electronic driver and all accessories. The fitting shall be IP 66 protected, duly prewired complete all as specified and directed.

4

-

-

... More
Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with squirrel cage induction motor complete all as specified and directed.

2

-

-

... More
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder

1

-

6128694.14

... More
SCHEDULE A PART V (Road, Path and Hardatanding) for details refer pdf folder

1

-

3011943.79

... More
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder

1

-

52755.1

... More
SCHEDULE A PART VI B (Sewage Disposal)

-

-

-

... More
M & L for construction of septic tank 10 users with class 'B' brick masonry wall, PCC in foundation floor, RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7 as directed.

1

-

-

... More
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 3 M effective depth all as specified and shown in drawing TD-309, sheet No 1/4 to 4/4

1

-

-

... More
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder

1

-

2671312.84

... More
SCHEDULE A PART VIII A (Security Wall Boundary Wall Fencing Gate etc) for details refer pdf folder

1

-

54324610

... More
SCHEDULE A PART VIII B (Security Wall Boundary Wall Fencing Gate etc) for details refer pdf folder

-

-

-

... More
S& F concertina coil 1050 mm Dia/56 Loops/2.5 mm core wire. Coil Diameter 1050mm Type of strip heavy Galvanised (IS 1730) Type of core wire Heavy Galvanized (IS 280-2006) Core wire diameter 2.50mm Dia Zinc coating to Strip minimum 200 GSM/Sq mm. Zinc Coating on wore. minimum 275 GSM/Sq mm (IS 6745-1972 reffiremed 2006) Tensile Strength of wire 1400-1500 N/Sq mm Weight 14.63 Kg (+5%) Number of loops 56, Blade length 22 mm Barb Profile medium Blade (MBBT) distance between barb 35 mm Stretchable length 12 meters. type of clip hardened stealing galvanized steel (83 Nos coils per Km)

3901.33

-

-

... More
S&F Tubes,15mm bore 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors

47.2

-

-

... More
M&L for 3mm thick mild steel, plain, black sheet Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.

1928.85

-

-

... More
SCHEDULE A PART IX A (Security System ) for details refer pdf folder

1

-

947514.99

... More
SCHEDULE A PART IX B (Security System ) for details refer pdf folder

-

-

-

... More
Supply, install & commissioning of wired 2 MP, Full High Definition (FHD) IR network Bullet Camera with 2 MP PS CMOS image sensor having maximum 2 MP (1920 X 1080) @ 25/30 fps, day/Night IICR (Infrared Cutfilter Removal), 3.6 mm fixed lens, IR range of 30 meter, IP 67 protection, DORI distance (55 m Detect, 22 m Observed, 11m Recognize, 5.5 m identified), power source DC 12 V/PoE including suitable size Pole mounting bracket complete all as specified and directed.

36

-

-

... More
Supply, fixing & connecting Network Video Receiver (NVR) 36 Ch (32 +4) IP Camera Input, with maximum incoming 1024 Mbps, recording 1024 Mbps and outgoing 800 Mbps bandwidth, supporting 8 SATA HDDs upto 16 TB each, 4 USB and 4 HDMI port simultaneous video output support to Multi brand network cameras, 100-240 Volt AC supply including wall mounted suitable size NVR rack with load bearing capcity of 15 Kg complete all as specified and directed.

1

-

-

... More
Supply and install HDD (Hard Disk Drive) 6 TB, SATA 6Gb/s suitable for Network video recordiing complete all as specified and directed.

8

-

-

... More
M&L for GI Pipe medium grade 80 mm dia as stand post to fix CCTV camera complete all as specified and directed. Note :- Necessary PCC work for foundation will be measured and paid seprately under respective item of BOQ.

180

-

-

... More
S& F smart LED display device, size 55 inches, 4K Ultra High Definition (4KUHD) ( 3840 x 2160) refresh rate 100 Hz , with HDMI and USB port complete all as specified and directed.

1

-

-

... More
M & L for inverter 1 KVA capacity, sine wave with 200 AH tall tubular 12V battery having minimum of 8 Hrs battery backup complete all as specified and directed.

1

-

-

... More
Supply and fix CAT-6, 24AWG UTP outdoor LAN cable double jacket, nominal conductor diameter 0.48mm+/- 0.020mm and outer diameter 5.8mm +/- 0.1 mm complete all as specified and directed by Engineer-in-Charge.

720

-

-

... More
S & F Power Extension Board with 5/6Amp, 6 Nos socket outlet complete with PVC insulated, PVC sheathed three core copper wire of size 1.5 sqmm complete all as specified and directed.

18

-

-

... More
M & L for ethernet media converter dual fiber with AC input adapter of input voltage 100-240 V and output voltage 5 V, 1.2 amp suitable for 10/100/1000 Mbps bandwidth complete all as specified and directed. Note: Quoted rates deemed to have included cost for fixing accessories such as mounting kit, screws, clips, connectors, mouse etc

38

-

-

... More
M&L for PoE (Power over Ethernet) 4 port, giga switch, network port 4 x 10/100/1000 Mbps, 2 x 1000 Mbps SFP port, 1x console port, switching capacity 12 Gbps, IP 40 protection, Power input Dc 48 -55 volt complete all as specified and directed. Note: Quoted rates deemed to have included cost for fixing accessories such as mounting kit, screws, clips, connectors, mouse etc

18

-

-

... More
Supply and fix Fibre optic cable 6 core, dia 6.2 mm, single mode unitube steel tape armoured (2FRP) with HDPE jacketing OFC cable complete all as specified and directed. Note: Quoted rates deemed to have included cost for fixing accessories such as mounting kit, screws, clips, connectors, mouse etc

8000

-

-

... More
Supply and fix junction box made from SMC/FRP sheet ready made of size (250 X 200 X 100) mm having 100 A aluminum busbar with connector fixed to pole / Wall with MS clamp (25 X 5) mm and nut bolts including MCB SP 6 Amp 10 KA 240 V with aluminium lugs complete all as specified and directed.

18

-

-

... More
Supply and lay 32mm High Density Polythylene Permanantly Lubricated (HDPE PLB) duct as per latest Techinal Specification Evaluation Centre (TSEC) specification all as specified and directed.

7500

-

-

... More
Supply and fix Fibre Optic Joint Termination enclosure Box with OFC Splicing Tray (JC box) of dimension (25.4 x 17.78 x 5.08) cm complete all as specified and directed.

18

-

-

... More
Supply and install PTZ outdoor weather proof box of inner dimension (30 X 9.6 X 8.9) cm including Clamps nut bolts etc complete all as specified and directed.

18

-

-

... More
M & L for fusion Splicing of optical fibre cable of any specification including insertion of heat shrink protective sleeve over fiber cable complete all as specified and directed.

36

-

-

... More
S & F fiber patch cord PVC insulated flame retarded single mode of size 3 mm confirming to IEC 61754 complete all as specified and directed

72

-

-

... More
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid.

396.25

-

-

... More
M&L for well brunt bricks sub class 'B' in old size as cable protection laid flat width wise complete all as specified and directed.

42539

-

-

... More
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder

1

-

782615.25

... More
SCHEDULE A PART X B (External Water Supply)

-

-

-

... More
M&L Construction of brick masonry valve chamber (as per standard drwaing) of internal size 500x500x500mm with sub class 'B' bricks in cement mortar 1:6 with 2mm thick MS sheet cover and angle iron frame made out of 40x40x6mm angle with locking arrangement duly painted with two coat of bitumen paint over a coat of red oxide primer incl necessary earth work and excavating in soft loose soil returning filling in removal of surplus soil complete incl 100 mm thick PCC 1:4:8 type B-2 (using 40 mm graded stone aggregate) in base concrete and 50 mm thick coping PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) over brick wall top incl. two coats of snowcem rendering plastering work complete all as specified and directed.

1

-

-

... More
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder

1

-

6987.2

... More
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)

-

-

-

... More
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ISI marked in trenches / ducts / through GI pipes under roads of size 70 sqmm 3.5 core confirming to IS: 7098 (part I)-1988 complete all as specifed and directed. Note:- (i) The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A (ii) Factory inspection carried out by the testing officer detailed by the accepting officer before dispatched from the factory

5650

-

-

... More
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid.

414.8

-

-

... More
M&L for well brunt bricks sub class 'B' in old size as cable protection laid flat width wise complete all as specified and directed.

44530

-

-

... More
Supply and laid GI medium grade pipe of size 50 mm dia for cable protection/ hanging ceiling fan complete all as specified and directed

18

-

-

... More
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT Feeder Pillar box, outdoor type, totally enclosed, dust and vermin proof, suitably ventilated, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, made out of 3.00 mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -

1

-

-

... More
(a) Busbar chamber : Electrically grade shrouded aluminium bus bar four Nos of capacity 200 Amps with current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension. INCOMER :- (i) MCCB 63 Amps, 415Volts, 4 pole 50 Hz, 16 KA fixed type in built instantaneous protection, Ics = 100 % Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 200 Amps digital type with built in selector switch, CTs of ratio 200/5A , 5va class 1.0 (set of three ) = 01 set.

-

-

-

... More
(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No (iv) Phase Indication lamps (RYB), LED type - 01 No (set of three). OUTGOING:- (i) MCB TPN 16-32 Amp (10 KA) - 04 Nos ( for PoE, Watch tower, Street light, Halogen Lights)

-

-

-

... More
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT Feeder Pillar box, outdoor type, totally enclosed, dust and vermin proof, suitably ventilated, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, made out of 3.00 mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -

6

-

-

... More
(a) Busbar chamber : Electrically grade shrouded aluminium bus bar four Nos of capacity 200 Amps with current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension. INCOMER :- (i) MCCB 63 Amps, 415Volts, 4 pole 50 Hz, 16 KA fixed type in built instantaneous protection, Ics = 100 % Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 200 Amps digital type with built in selector switch, CTs of ratio 200/5A , 5va class 1.0 (set of three ) = 01 set.

-

-

-

... More
(iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three). OUTGOING:- (i) MCB TPN 16-32 Amp (10 KA) - 03 Nos ( for PoE, Street light, Halogen Lights) Note:- (i) Factory inspection carried out by the testing officer detailed by the accepting officer before dispatched from the factory

-

-

-

... More
M& L for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by GI strip of size 25 x 4 mm earth strip by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earthing work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed by Engr-in-charge

14

-

-

... More
Note:-(1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 Kg/Sqm in lieu of CI cover (2) Cost of addtional GI wire strip than 7.5 mtr will be measured and paid seperately under relevant item

-

-

-

... More
SCHEDULE A PART XII (Demolition)

1

-

360264.56

... More
Note : Tenderers may note that amount of credit Rs 08,93,273.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.