Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Oct 2024
Closing Soon18 Nov 2024
Tender Amount₹ 8,00,000
Costs
EMD
₹ 16,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679201_1Tender No
AGE(I)/FAT/ET-36 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material of out side MD land complete all as specified and directed
120
-
-
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with Coarse Sand finished even and smooth without using extra cement complete all as specified and directed
150
-
-
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over alkali resistant primer complete all as specified and as directed.
150
-
-
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. But including concrete articles.
2
-
-
M & L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete
1.7
-
-
-ditto- all as per item above but except Bricks etc complete all as specified and directed.
0.3
-
-
M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment and making surface smooth and applying two coats of cement base paint over alkali resistant primer complete all as directed.
900
-
-
M & L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed
40
-
-
M & L for preparation of old plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
80
-
-
S&F 600mmx450mm bevelled edge looking Mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with aluminum beading on sides fixed to walls with screws complete all as specified and directed.
4
-
-
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed up, capacity in 2000 Ltrs, hoisted and fixed in position with all fittings and fixtures including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 25mm-455gms) including dismantling of existing water tank complete all as specified in SSR Part-I and directed.
1
-
-
S&F in repair Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity white, with inlet, ball float and handle, PVC connection 450 mm including brackets complete all as specified and directed.
3
-
-
S&F in repair 15mm bore Chromium plated Bib taps fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
6
-
-
S&F Angle/Stop valves chromium plated fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
8
-
-
S&F in repairs 15mm Pillar taps, fancy type cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed.
6
-
-
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
15
-
-
Supply & Fixing in repair 32 mm dia PVC Waste pipe suitable for Wash hand basin/kitchen sink complete all as specified and directed
6
-
-
Taking up or down Steel Tubing bore of pipe in 15 mm and connections, and removal to store etc complete all as specified and directed.
20
-
-
Taking up or down Steel Tubing bore of pipe in 20 mm and connections, and removal to store etc complete all as specified and directed.
25
-
-
Taking up or down Steel Tubing bore of pipe in 25 mm and connections, and removal to store etc complete all as specified and directed.
25
-
-
S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
20
-
-
S&F Steel Tubes Medium Grade Bore of tube in 20 mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
25
-
-
S&F Steel Tubes Medium Grade Bore of tube in 25 mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
25
-
-
S&F in repair gun metal gate valve 20mm dia, globe with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
3
-
-
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of grade Fe-410 W (Gde-E-250 Quality A) as in framing, glazing, cage and simmilar complete all as specified and directed
290
-
-
S&F Wire netting of galvanised steel wire 1.40mm dia fixed of mesh size 25 mm with tinned tacks of wire staples to steel/wooden frame complete all as specified and directed
27
-
-
M & L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed.
27
-
-
S&F in repair Aluminium (Extruded Section) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed
5
-
-
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
2
-
-
M&L for 100mm thick PCC 1:4:8 type D-2( using 40mm graded crushed stone aggregate) as in flooring and mass concrete to complete all as specified and directed
100
-
-
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
100
-
-
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
64
-
-
Taking down copper/aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
353
-
-
M&Lfor One light/fan/exhaust fan point controlled by one switch point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including suitable concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following-
Note- (i) The quoted rate is deemed to be included for cutting of chases for fixising of conduit. (ii) Rate for filling of Cutting chases for concealed shall be filled with using CM 1:4 making dood disturbed suface with existing paint to match colour of the existing surfaces & colour. (iii) Wire shall be used with proper clour code (Red, Black, Green, Yellow and blue).
10
-
-
All as per item above here in before but for One 5 pin 5 Amp socket point on independent board.
24
-
-
All as per item above here in before but for One 5 pin 5 Amp socket point controlled on same board.
5
-
-
All as per item above here in before but for power point 6/16 Amp 6 Pin switch socket combination on independent board with two run of 2.5 Sqmm FRLS unsheathed copper conductor with single core 2.5 Sqmm copper wire multistranded as earth continiuty wire connecgted to common earth dolly complete all as specified.
Note- (i) The quoted rete is deemed to be included for cutting of chases for fixising of conduit.. (ii) Rate for filling of Cutting chases for concealed shall be filled with using CM 1:4 making dood disturbed suface with existing paint to match colour of the existing surfaces & colour. (iii) Wire shall be used with proper clour code (Red, Black, Green, Yellow and blue)
25
-
-
S&F Switch Piano flush type 5 Amp single pole one way complete all as specified and as directed
10
-
-
S&F Switch socket combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and as directed .
29
-
-
S&F Switch socket combination 2 in 1 flush type 16 Amp 5 Pin complete all as specified and as directed
25
-
-
S&F in repair electronic fan regulator 5 stepped type complete all as specified and directed
5
-
-
S&F Ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
10
-
-
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade of suitable size concealed in wall for sub main connection including two runs and one run of 6 Sqmm FRLS insulated multistranded unsheathed copper conductor wire multistranded used as a earth wire to common earth dolly complete all as specified & directed.
353
-
-
Supply and fixing in repair of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
2
-
-
Supply and fixing in repair MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with alum thimbles as required complete all as specified and as directed.
4
-
-
S&F of MCCB 100 Amp, AC 50 Hz, 415 volts 16KA, 4 Pole (Tripple Pole and Neutral) including complete electrical connection by appropriate complete all as specified and directed
2
-
-
S&F of MCB SPN 63 Amp AC 50 Hz, 240 volt rapturing capactiy 10 KA 'C' curve complete all as specifed and directed.
4
-
-
S&F of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
36
-
-
S&F of Reserve Plus Rechargeable Emergency Inverter LED Batten, 20-watt Compact 3/4-feet LED Tubelight, Cool Day Light complete all as specified and directed.
35
-
-
S & F in repair building security LED Light 45 Watt with lumen 6000k made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-66 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 25 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 25x6 mm for fixing of builiding security light fittings complete all as specified and directed.
4
-
-
S&F in replacement of on load change over in sheet metel enclosure 200 Amp, 4 Way TPN 415 Volt including fitting of cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
1
-
-
Taking up and down of ceiling fan from any position and Rewinding of old burnt winding of motor of ceiling fan size 1200/1400 mm sweep complete with super enamelled copper wire of suitable size with painting of fan with proper insulation of stator of motor of fan with paiting of fan icluding fan blade, down rod and fan body with fixing of fan blade new screw of suitable size complete all as specified and directed. Note :- 1. Fan should have 900 RPM after winding the fan.
2. Rates quoute are exclusive of Fan taking up and down shall be included in quoted rate.
18
-
-
All as per item above but for exhasut fan of size 230/300 mm sweep… ditto as above….
6
-
-
S&F ball bearing of NBC/ SKF of suitable size complete all as specified and directed.
20
-
-
S&F Fan capacitor, 230 Volts of the 2.15/2.5/3.15/4 MFD capacity complete all as specified and directed.
18
-
-
Supply, layig, connecting, testing and commissioning of 25 Sqmm 4 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc incl dismantaling all as specified and directed.
175
-
-
Supply, layig, connecting, testing and commissioning of 70 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc incl dismantaling all as specified and directed.
40
-
-
S & F 40 mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clapms and nut and bolts/washer complete all as specified and directed.
20
-
-
M&L for sand cushioning to U/G cable in layers of 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed.
Note :- Only Puned down volume shall be measured.
10
-
-
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
1300
-
-
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
18
-
-
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed
8
-
-
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed
10
-
-
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but with earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) including dismantling of exsisting earthing complete all as specified and as directed.
(Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%